Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Spine J ; 2024 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-38290621

RESUMO

BACKGROUND CONTEXT: The functional goals of cervical disc arthroplasty (CDA) are to restore enough range of motion (ROM) to reduce the risk of accelerated adjacent segment degeneration but limit excessive motion to maintain a biomechanically stable index segment. This motion-range is termed the "Physiological mobility range." Clinical studies report postoperative ROM averaged over all study subjects but they do not report what proportion of reconstructed segments yield ROM in the Physiological mobility range following CDA surgery. PURPOSE: To calculate the proportion of reconstructed segments that yield flexion-extension ROM (FE-ROM) in the Physiological mobility range (defined as 5-16 degrees) by analyzing the 24-month postoperative data reported by clinical trials of various cervical disc prostheses. STUDY DESIGN/SETTING: Analysis of 24-month postoperative FE-ROM data from clinical trials. PATIENT SAMPLE: Data from 1,173 patients from single-level disc replacement clinical trials of 7 cervical disc prostheses. OUTCOME MEASURES: 24-month postoperative index-level FE-ROM. METHODS: The FE-ROM histograms reported in Food and Drug Administration-Investigational Device Exemption (FDA-IDE) submissions and available for this analysis were used to calculate the frequencies of implanted levels with postoperative FE-ROM in the following motion-ranges: Hypomobile [0-4 degrees], Physiological [5-16 degrees], and Hypermobile [≥17 degrees]. The ROM histograms also allowed calculation of the average ROM of implanted segments in each of the 3 motion-ranges. RESULTS: Only 762 of 1,173 patients (implanted levels) yielded 24-month post-CDA FE-ROM in the physiological mobility range [5-16 degrees]. The proportions ranged from 60% to 79% across the 7 disc-prostheses, with an average of 65.0%±6.2%. Three-hundred and two (302) of 1,173 implanted levels yielded ROM in the 0-4-degree range. The proportions ranged from 15% to 38% with an average of 25.7%±8.9%. One-hundred and nine (109) of 1,173 implanted levels yielded ROM of ≥17 degrees with a range of 2%-21% and an average proportion of 9.3%±7.9%. The prosthesis with built-in stiffness due to its nucleus-annulus design yielded the highest proportion (103/131, 79%) of implanted segments in the physiological mobility range, compared to the cohort average of 65% (p<.01). Sixty-five of the 350 (18.6%) discs implanted with the 2 mobile-core designs in this cohort yielded ROM≥17 degrees as compared to the cohort average of 9.3% (109/1,173) (p<.05). At 2-year post-CDA, the "hypomobile" segments moved on average 2.4±1.2 degrees, those in the "physiological-mobility" group moved 9.4±3.2 degrees, and the hypermobile segments moved 19.6±2.6 degrees. CONCLUSIONS: Prosthesis design significantly influenced the likelihood of achieving FE-ROM in the physiological mobility range, while avoiding hypomobility or hypermobility (p<.01). Postoperative ROM averaged over all study subjects provides incomplete information about the prosthesis performance - it does not tell us how many implanted segments achieve physiological mobility and how many end up with hypomobility or hypermobility. We conclude that the proportion of index levels achieving post-CDA motions in the physiological mobility range (5-16 degrees) is a more useful outcome measure for future clinical trials.

2.
J Biomech ; 163: 111924, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38237496

RESUMO

The biomechanical literature describes axial rotation occurring coupled with lateral bending and flexion in the cervical spine. Since the head is kept level during some activities of daily living, we set out to investigate the changes in total and segmental motion that occur when a level gaze constraint is applied to cadaveric cervical spine specimens during axial rotation. 1.5Nm of left and right axial rotation moment was applied to sixteen C2-T1 cadaveric specimens with C2 unconstrained and C2 constrained to simulate level gaze. Overall and segmental motions were determined using optoelectronic motion measurement and specimen-specific kinematic modeling. Without a kinematic constraint on C2, motions were as described in the literature; namely, flexion and lateral bending to the same side as axial rotation. Keeping C2 level reduced that total axial rotation range of motion of the specimens. Changes were also produced in segmental coupled rotation in all specimens. The observed changes included completely opposite coupled motion than in the uncoupled specimens, and traditional coupled behavior at one load extreme and the opposite at the other extreme. Constraining C2 during axial rotation to simulate level gaze can produce coupled motion that differs from the classically described flexion and lateral bending to the same side as axial rotation. Statement of Clinical Significance: Activities of daily living that require the head to be kept level during axial rotation of the cervical spine may produce segmental motions that are quite different from the classically described motions with implications for biomechanical experiments and implant designers.


Assuntos
Atividades Cotidianas , Vértebras Cervicais , Humanos , Rotação , Fenômenos Biomecânicos , Amplitude de Movimento Articular , Cadáver
3.
Foot Ankle Orthop ; 8(3): 24730114231188112, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37506092

RESUMO

Background: Soft tissue complications after Achilles tendon repair has led to increased interest in less invasive techniques. Various limited open techniques have gained popularity as an alternative to open operative repair. The purpose of this study was to biomechanically compare an open Krackow and limited open repair for Achilles tendon rupture. We hypothesized that there would be no statistical difference in load to failure, work to failure, and initial linear stiffness. Methods: A simulated Achilles tendon rupture was created 4 cm proximal to its insertion in 18 fresh-frozen cadaveric below-knee lower limbs. Specimens were randomized to open or limited open PARS Achilles Jig System repair. Repairs were loaded to failure at a rate of 25.4 mm/s to reflect loading during normal ankle range of motion. Load to failure, work to failure, and initial linear stiffness were compared between the 2 repair types. Results: The average load to failure (353.8 ± 88.8 N vs 313.3 ± 99.9 N; P = .38) and work to failure (6.4 ± 2.3 J vs 6.3 ± 3.5 J; P = .904) were not statistically different for Krackow and PARS repair, respectively. Mean initial linear stiffness of the Krackow repair (17.8 ± 5.4 N/mm) was significantly greater than PARS repair (11.8 ± 2.5 N/mm) (P = .011). Conclusion: No significant difference in repair strength was seen, but higher initial linear stiffness for Krackow repair suggests superior resistance to gap formation, which may occur during postoperative rehabilitation. With equal repair strength, but less soft tissue devitalization, the PARS may be a favorable option for patients with risk factors for soft tissue complications.

4.
Foot Ankle Int ; 44(10): 1044-1050, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37497892

RESUMO

BACKGROUND: Transarticular screw fixation is a common surgical treatment for tarsometatarsal ligamentous (Lisfranc) injuries. Iatrogenic damage to articular cartilage from screw placement, however, has been thought to potentially lead to increased risk of tarsometatarsal (TMT) joint arthritis after initial injury. To date, no study has evaluated the effect of weightbearing on articular cartilage after screw fixation. The aim of this study was to create a Lisfranc injury and quantify and compare articular damage due to screw fixation before and after simulated weightbearing. METHODS: A ligamentous Lisfranc injury was created in 10 cadaveric specimens and treated with transarticular screws. Specimens were cycled for 1000 cycles at 250 N to simulate 2 weeks of physiologic weightbearing. Rotation and diastasis across the Lisfranc complex were measured. Articular injury as a percentage of total articular surface was measured using digital imaging of the first and second TMT joint before and after simulated weightbearing. Comparisons between articular damage were made and statistical analysis was performed. RESULTS: Simulated partial weightbearing increased articular injury 1.44-fold (P < .001). The second metatarsal (M2) showed the greatest increase (1.54-fold, P = .0047), whereas the first (M1) showed the least (1.35-fold, P = .0083). Increases seen at the medial (1.43-fold, P = .0387) and middle cuneiform (1.44-fold, P = .0292) were intermediate between the values seen at M2 and M1. CONCLUSION: Articular damage from transarticular screw fixation significantly increased after simulated partial weightbearing. This may increase the risk of arthritis and future morbidity when using transarticular screws for the treatment of ligamentous Lisfranc injuries. CLINICAL RELEVANCE: Iatrogenic damage to articular cartilage due to screw fixation of ligamentous Lisfranc injuries may be increased with weightbearing.


Assuntos
Artrite , Ossos do Metatarso , Humanos , Pé/cirurgia , Ossos do Metatarso/cirurgia , Ossos do Metatarso/lesões , Ligamentos Articulares/cirurgia , Ligamentos Articulares/lesões , Artrite/cirurgia , Suporte de Carga , Doença Iatrogênica
5.
Clin Biomech (Bristol, Avon) ; 102: 105898, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36764102

RESUMO

BACKGROUND: Powered instrumentation is often used for bone preparation and/or removal in many orthopaedic procedures but does risk thermogenesis. This study compares biomechanical properties of a fluted burr and a novel fluteless resurfacing tool. METHODS: Twenty cadaveric metatarsals were tested with four predetermined cutting forces to evaluate heat generation and cutting rate for the fluted burr and fluteless resurfacing tool over 40 s or until a depth of 4 mm was reached. Cutting rate was calculated from displacement transducer data. Heat generation was measured by thermocouples placed in the bone adjacent to the burring site. Assuming a body temperature of 37 °C, a 10 °C increase in heat was used as the threshold of inducing osteonecrosis. FINDINGS: At 1.0 N and 1.7 N, the thermal osteonecrosis threshold was reached at comparable times between burrs, while the bone removed by the resurfacing tool was on average five times greater than fluted burr at 1.0 N and over twice as great at 1.7 N. Statistical analysis of these common cutting forces showed the resurfacing tool had significantly higher cutting rates (P < 0.01). As a result, the fluted burr produced higher temperatures for the same amount of bone removal (P < 0.01). INTERPRETATION: In a cadaveric study, the fluteless resurfacing tool demonstrated higher bone cutting rates and lower heat generation for the same amount of bone removed than a traditional fluted burr.


Assuntos
Temperatura Alta , Osteonecrose , Humanos , Osso e Ossos , Instrumentos Cirúrgicos , Cadáver
6.
J Orthop Trauma ; 37(3): e104-e110, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36219777

RESUMO

OBJECTIVES: To biomechanically investigate a novel modified all-suture construct compared with commercially available suspensory button fixation for stabilization of the syndesmosis. METHODS: Eight matched pairs of cadaver lower limbs were obtained. We used a material testing machine and Optotrak optoelectronic 3D motion measurement system for testing. Syndesmotic injuries were simulated, and specimens were fixed with either a suspensory suture button or modified all-suture construct. Repaired specimens were then cyclically loaded for 500 cycles. Spatial relationship of the tibia and fibula were continuously monitored for the intact, destabilized, and repaired states. The results were analyzed using independent samples t test. RESULTS: There was no significant difference in sagittal or coronal plane translation between intact and either repair. Compared with the intact state, both repair techniques demonstrated significantly more external rotation of the fibula relative to the tibia and decreased construct stiffness. Cycling of the specimens did not significantly increase coronal or sagittal plane translation; however, external rotation of the fibula relative to the tibia increased and stiffness decreased with cycling for both repair techniques. CONCLUSIONS: Our data suggest that sagittal and coronal plane translation is no different from the intact state for both fixation techniques. However, rotation of the fibula relative to the tibia was increased, and construct stiffness was decreased compared with the intact state for both fixation techniques. These findings suggest that an all-suture construct could offer syndesmotic fixation comparable with proprietary suspensory button fixation in a cadaver model.


Assuntos
Traumatismos do Tornozelo , Parafusos Ósseos , Humanos , Fíbula/cirurgia , Articulação do Tornozelo/cirurgia , Suturas , Traumatismos do Tornozelo/cirurgia , Técnicas de Sutura , Cadáver
7.
Hand (N Y) ; 18(2): 314-319, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-33985362

RESUMO

BACKGROUND: We examined the effect of Kirschner wire (K-wire) reuse and use of oscillating mode on heat generation within cortical bone. METHODS: Two trocar-tipped K-wires were drilled through the diaphysis of each of 30 human metacarpals and phalanges: one K-wire was inserted in rotary mode and another in oscillating mode. Each wire was reused once. Thermocouples placed within the dorsal and volar bone adjacent to the K-wire drill path measured temperatures throughout each test. RESULTS: Peak cortex temperatures were 25°C to 164°C. Rotary drilling achieves peak temperatures quicker (31 ± 78 seconds vs 44 ± 78 seconds, P = .19) than oscillating drilling, but insertion time is also less, resulting in lower overall heat exposure. This effect is also seen when the K-wire is reused (34 ± 70 seconds vs 41 ± 85 seconds, P = .4). The length of time that cortical bone was exposed to critical temperatures (47°C or more) was significantly higher when a wire was reused (36 ± 72 seconds vs 43 ± 82 seconds, P = .008). Peak temperatures greater than 70°C (a temperature associated with instantaneous cell death) were observed on many occasions. CONCLUSIONS: Overall heat exposure may be higher if a K-wire is reused or inserted in oscillating mode. In the absence of external cooling, K-wire insertion into cortical bone can easily expose bone to temperatures that exceed 70°C and may increase the risk of osteonecrosis.


Assuntos
Ossos Metacarpais , Procedimentos Ortopédicos , Humanos , Temperatura Alta , Fios Ortopédicos , Temperatura , Procedimentos Ortopédicos/métodos , Ossos Metacarpais/cirurgia
8.
Clin Biomech (Bristol, Avon) ; 100: 105795, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36252452

RESUMO

BACKGROUND: The goal was to determine the effect of addition of oblique trajectory distal interlock screws to a retrograde intramedullary femoral nail on implant stability (stiffness), cycles to failure and mode of failure. The hypothesis was that addition of oblique screws would increase implant stability and number of loading cycles to failure. METHODS: Eight matched pairs were tested; one femur implanted with a femoral nail with only transverse distal interlock screws and the other with transverse and oblique interlock screws. Axial compressive load was applied to the femoral head and the gluteal tendon was tensioned vertically to simulate standing or at 45° to the sagittal plane to simulate stair climbing. Loads were cycled to increasing amplitude until failure of fixation (10 mm displacement or 10° rotation). FINDINGS: In simulated standing, oblique screw specimen had greater sagittal bending (bowing) than transverse only specimen. Transverse (axial) plane motion was higher in simulated stair climbing in oblique screw specimen. Oblique screw specimen had higher sagittal plane translation at 600 N of load. At 300 N, oblique screw specimen had lower internal-external rotation than transverse only specimen. A larger number of cycles to failure were observed in four oblique screw of seven paired specimen. Failure (10 mm or 10 degrees of motion) was only achieved during simulated stair climbing. INTERPRETATION: Our hypothesis that adding oblique screws improves fixation was rejected. Activities of daily living other than standing may constitute a challenge to fracture fixation; fixation failure occurred at lower loads in simulated stair climbing than standing.


Assuntos
Atividades Cotidianas , Humanos
9.
N Am Spine Soc J ; 12: 100170, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36185340

RESUMO

Background: The theoretical advantages of hybrid constructs over multi-level fusion have been illustrated in clinical and biomechanical studies. However, there is no biomechanical data on hybrid constructs using load control analyses. There is also no clear data on whether there is a biomechanical difference if the arthroplasty is below or above a 1- or 2-level fusion. This work investigated the effect on segmental motion of having a cervical total disc arthroplasty implanted above or below a 1- or 2-level fusion. Methods: Segmental motions of 16 C2-T1 cervical spine specimens were measured as the specimens were tested to 1.5Nm in axial rotation and in flexion-extension under compressive preload. Tests were conducted on intact specimens, and then after arthroplasty with a 1-level and 2-level fusion. 8 specimens were in test Group 1, where the hybrid configuration had a total disc arthroplasty above a 1- or 2-level fusion. The arthroplasty was below the 1- and 2-level fusion in Group 2. Load control and displacement control analyses were conducted to determine the effect of the hybrid configurations on segmental motion. Results: In load control, compensatory motion increases were found at all non-instrumented cervical spine segments in flexion-extension and axial rotation. Flexion-extension and axial rotation ranges of motion at the total disc arthroplasty level were less than 1° different than intact.In displacement control, there was no consistent pattern of compensatory motion. Range of motion at the arthroplasty level was within 3.5° of intact. Conclusions: The total disc arthroplasty segmental level in a hybrid construct has similar amounts of motion as intact. This may shield the arthroplasty level and adjacent levels from supra-physiological motion and loading. These results suggest that a hybrid construct may be protective of adjacent segments, whether the total disc arthroplasty is above or below the fusion.

10.
Am J Sports Med ; 50(6): 1541-1549, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35323067

RESUMO

BACKGROUND: Individual contributions of the rotator cuff (RC) and superior capsule (SC) to prevent superior translation of the humerus are not well understood. PURPOSE: To evaluate the relative contributions of the SC and RC to normal and pathologic shoulder biomechanics by determining their independent effects on superior humeral translation. STUDY DESIGN: Controlled laboratory study. METHODS: Twelve cadaveric shoulders were tested at 0º, 45º, and 90º of abduction under 5 conditions: intact RC/SC, RC sectioned first, SC sectioned first, both structures sectioned, and RC repair. Matched pairs were randomly assigned to the second or third testing condition (RC or SC sectioned first). Specimens were tested under 2 static conditions (40-N deltoid load [balanced load], 80-N deltoid load [superiorly directed load]) and 1 dynamic condition during active abduction. A mixed-design 2-way repeated-measures analysis of variance with Bonferroni adjustments was performed to compare testing conditions. Paired t tests were used to compare specimens in the intact state versus the repaired state. Significance was set at P < .05. RESULTS: During balanced deltoid loading at 0° and 45º, there was significantly greater humeral translation when both structures were sectioned as compared with the intact state and with both isolated sectioned states (P < .05 for all). No significant differences were observed between or within groups at 90º of abduction. These effects remained consistent with superiorly directed loading. Dynamic testing of both groups showed a significant increase in superior translation for specimens in which the RC was deficient versus the intact state (P = .027), with no difference when the SC was sectioned. The RC repair state returned translation to values similar to the intact state at all abduction angles and loading conditions (P > .05). CONCLUSION: In this cadaveric study, the SC and RC played an important role in preventing superior humeral translation; however, dynamic testing suggested preferential contribution of the RC. RC repair was effective in preventing superior humeral translation, even with a sectioned SC at the level of the glenohumeral joint. CLINICAL RELEVANCE: RC repair was effective in preventing superior humeral translation, even in the presence of a sectioned SC at the level of the glenohumeral joint in this cadaveric model. Our data lay the groundwork for future studies investigating the clinical effect of RC repair in an SC sectioned state.


Assuntos
Lesões do Manguito Rotador , Articulação do Ombro , Fenômenos Biomecânicos , Cadáver , Humanos , Amplitude de Movimento Articular , Manguito Rotador/cirurgia , Lesões do Manguito Rotador/cirurgia , Articulação do Ombro/cirurgia
11.
Spine J ; 21(4): 708-719, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33160033

RESUMO

BACKGROUND CONTEXT: Transition from standing to sitting significantly decreases lumbar lordosis with the greatest lordosis-loss occurring at L4-S1. Fusing L4-S1 eliminates motion and thus the proximal mobile segments maybe recruited during transition from standing to sitting to compensate for the loss of L4-S1 mobility. This may subject proximal segments to supra-physiologic flexion loading. PURPOSE: Assess effects of instrumented fusion versus motion preservation at L4-L5 and L5-S1 on lumbar spine loads and proximal segment motions during transition from standing to sitting. STUDY DESIGN: Biomechanical study using human thoracolumbar spine specimens. METHODS: A novel laboratory model was used to simulate lumbosacral alignment changes caused by a person's transition from standing to sitting in eight T10-sacrum spine specimens. The sacrum was tilted in the sagittal plane while constraining anterior-posterior translation of T10. Continuous loading-data and segmental motion-data were collected over a range of sacral slope values, which represented transition from standing to different sitting postures. We compared different constructs involving fusions and motion preserving prostheses across L4-S1. RESULTS: After L4-S1 fusion, the sacrum could not be tilted as far posteriorly compared to the intact spine for the same applied moment (p<.001). For the same reduction in sacral slope, L4-S1 fusion induced 2.9 times the flexion moment in the lumbar spine and required 2.4 times the flexion motion of the proximal segments as the intact condition (p<.001). Conversely, motion preservation at L4-S1 restored lumbar spine loads and proximal segment motions to intact specimen levels during transition from standing to sitting. CONCLUSIONS: In general, sitting requires lower lumbar segments to undergo flexion, thereby increasing load on the lumbar disks. L4-S1 fusion induced greater moments and increased flexion of proximal segments to attain a comparable seated posture. Motion preservation using a total joint replacement prosthesis at L4-S1 restored the lumbar spine loads and proximal segment motion to intact specimen levels during transition from standing to sitting. CLINICAL SIGNIFICANCE: After L4-S1 fusion, increased proximal segment loading during sitting may cause discomfort in some patients and may lead to junctional breakdown over time. Preserving motion at L4-S1 may improve patient comfort and function during activities of daily living, and potentially decrease the need for adjacent level surgery.


Assuntos
Vértebras Lombares , Fusão Vertebral , Atividades Cotidianas , Fenômenos Biomecânicos , Humanos , Amplitude de Movimento Articular , Postura Sentada
12.
Clin Biomech (Bristol, Avon) ; 78: 105078, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32585556

RESUMO

BACKGROUND: Conditions requiring cervical decompression and stabilization are commonly treated using anterior cervical discectomy and fusion using an anterior cage-plate construct. Anterior zero profile integrated cages are an alternative to a cage-plate construct, but literature suggests they may result in less motion reduction. Interfacet cages may improve integrated cage stability. This study evaluated the motion reduction of integrated cages with and without supplemental interfacet fixation. Motion reduction of integrated cages were also compared to published cage-plate results. METHODS: Seven cadaveric (C2-T1) spines were tested in flexion-extension, lateral bending, and rotation. Specimens were tested: 1) intact, 2) C6-C7 integrated cage, 3) C6-C7 integrated cage + interfacet cages, 4) additional integrated cages at C3-C4 and C4-C5, 5) C3-C4, C4-C5 and C6-C7 integrated cages + interfacet cages. Motion, lordosis, disc and neuroforaminal height were assessed. FINDINGS: Integrated cage at C6-C7 decreased flexion-extension by 37% (P = .06) and C3-C5 by 54% (P < .01). Integrated + interfacet cages decreased motion by 89% and 86% compared to intact (P < .05). Integrated cages increased lordosis at C4-C5 and C6-C7 (P < .01). Integrated + interfacet cages returned C3-C5 lordosis to intact values, while C6-C7 remained more lordotic (P = .02). Compared to intact, neuroforaminal height increased after integrated cages at C3-C5 (P ≤ .01) and at all levels after interfacet cages (P < .01). INTERPRETATION: Anterior integrated cages provides less stability than traditional cage-plate constructs while supplemental interfacet cages improve stabilization. Integrated cages provide more lordosis at caudal levels and increase neuroforaminal height more at cranial levels. After interfacet cages, posterior disc height and neuroforaminal height increased more at the caudal segments.


Assuntos
Vértebras Cervicais/fisiologia , Vértebras Cervicais/cirurgia , Discotomia/instrumentação , Fusão Vertebral/instrumentação , Fenômenos Biomecânicos , Placas Ósseas , Cadáver , Feminino , Humanos , Pessoa de Meia-Idade , Amplitude de Movimento Articular , Rotação
13.
J Neurosurg Spine ; : 1-7, 2020 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-32330888

RESUMO

OBJECTIVE: The authors conducted a study to determine whether a change in T1 tilt results in a compensatory change in the cervical sagittal vertical axis (SVA) in a cadaveric spine model. METHODS: Six fresh-frozen cadavers (occiput [C0]-T1) were cleaned of soft tissue and mounted on a customized test apparatus. A 5-kg mass was applied to simulate head weight. Infrared fiducials were used to track segmental motion. The occiput was constrained to maintain horizontal gaze, and the mounting platform was angled to change T1 tilt. The SVA was altered by translating the upper (occipital) platform in the anterior-posterior plane. Neutral SVA was defined by the lowest flexion-extension moment at T1 and recorded for each T1 tilt. Lordosis was measured at C0-C2, C2-7, and C0-C7. RESULTS: Neutral SVA was positively correlated with T1 tilt in all specimens. After increasing T1 tilt by a mean of 8.3° ± 2.2°, neutral SVA increased by 27.3 ± 18.6 mm. When T1 tilt was reduced by 6.7° ± 1.4°, neutral SVA decreased by a mean of 26.1 ± 17.6 mm.When T1 tilt was increased, overall (C0-C7) lordosis at the neutral SVA increased from 23.1° ± 2.6° to 32.2° ± 4.4° (p < 0.01). When the T1 tilt decreased, C0-C7 lordosis at the neutral SVA decreased to 15.6° ± 3.1° (p < 0.01). C0-C2 lordosis increased from 12.9° ± 9.3° to 29.1° ± 5.0° with increased T1 tilt and decreased to -4.3° ± 6.8° with decreased T1 tilt (p = 0.047 and p = 0.041, respectively). CONCLUSIONS: Neutral SVA is not a fixed property but, rather, is positively correlated with T1 tilt in all specimens. Overall lordosis and C0-C2 lordosis increased when T1 tilt was increased from baseline, and vice versa.

14.
J Hand Surg Am ; 44(3): 208-215, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30660397

RESUMO

PURPOSE: Conventional suture repairs, when stressed, fail by suture rupture, knot slippage, or suture pull-through, when the suture cuts through the intervening tissue. The purpose of this study was to compare the biomechanical properties of flexor tendon repairs using a novel mesh suture with traditional suture repairs. METHODS: Sixty human cadaveric flexor digitorum profundus tendons were harvested and assigned to 1 of 3 suture repair groups: 3-0 and 4-0 braided poly-blend suture or 1-mm diameter mesh suture. All tendons were repaired using a 4-strand core cruciate suture configuration. Each tendon repair underwent linear loading or cyclic loading until failure. Outcome measures included yield strength, ultimate strength, the number of cycles and load required to achieve 1-mm and 2-mm gap formation, and failure. RESULTS: Mesh suture repairs had significantly higher yield and ultimate force values when compared with 3-0 and 4-0 braided poly-blend suture repairs under linear testing. The average force required to produce repair gaps was significantly higher in mesh suture repairs than in conventional suture. Mesh suture repairs endured a significantly greater number of cycles and force applied before failure compared with both 3-0 and 4-0 conventional suture. CONCLUSIONS: This ex vivo biomechanical study of flexor tendon repairs using a novel mesh suture reveals significant increases in average yield strength, ultimate strength, and average force required for gap formation and repair failure with mesh suture repairs compared with conventional sutures. CLINICAL RELEVANCE: Mesh suture-based flexor tendon repairs could lead to improved healing at earlier time points. The findings could allow for earlier mobilization, decreased adhesion formation, and lower rupture rates after flexor tendon repairs.


Assuntos
Teste de Materiais , Telas Cirúrgicas , Suturas , Traumatismos dos Tendões/cirurgia , Cadáver , Humanos , Resistência à Tração
15.
J Wrist Surg ; 7(2): 101-108, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29576914

RESUMO

Background An injury to the scapholunate interosseous ligament (SLIL) leads to instability in the scapholunate joint. Temporary fixation is used to protect the ligament during reconstruction or healing of the repair. Rigid screw fixation-by blocking relative physiological motion between the scaphoid and lunate-can lead to screw loosening, pullout, and fracture. Purpose This study aims to evaluate changes in scaphoid and lunate kinematics following SLIL injury and the effectiveness of an articulating screw at restoring preinjury motion. Materials and Methods The kinematics of the scaphoid and lunate were measured in 10 cadaver wrists through three motions driven by a motion simulator. The specimens were tested intact, immediately following SLIL injury, after subsequent cycling, and after fixation with a screw. Results Significant changes in scaphoid and lunate motion occurred following SLIL injury. Postinjury cycling increased motion changes in flexion-extension and radial-ulnar deviation. The motion was not significantly different from the intact scapholunate joint after placement of the articulating screw. Conclusion In agreement with other studies, sectioning of the SLIL led to significant kinematic changes of the scaphoid and lunate in all motions tested. Compared with intact scapholunate joint, no significant difference in kinematics was found after placement of the screw indicating a correction of some of the changes produced by SLIL transection. These findings suggest that the articulating screw may be effective for protecting a SLIL repair while allowing the physiological rotation to occur between the scaphoid and lunate. Clinical Relevance A less rigid construct, such as the articulating screw, may allow earlier wrist rehabilitation with less screw pullout or failure.

16.
J Orthop Res ; 34(8): 1389-98, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-26990567

RESUMO

MRI allows non-invasive assessment of intervertebral disc degeneration with the added clinical benefit of using non-ionizing radiation. What has remained unclear is the relationship between assessed disc degeneration and lumbar spine kinematics. Kinematic outcomes of 54 multi-segment (L1-Sacrum) lumbar spine specimens were calculated to discover if such an underlying relationship exists with degeneration assessed using the Pfirrmann grading system. Further analyses were also conducted to determine if kinematic outcomes were affected by motion segment level, gender or applied compressive preload. Range of motion, hysteresis, high flexibility zone size and rotational stiffness in flexion-extension, lateral bending and axial rotation were the kinematic outcomes. Caudal intervertebral discs in our study sample were more degenerative than cranial discs. L5-S1 discs had the largest flexion-extension range of motion (p < 0.005) and L1-L2 discs the lowest flexion high flexibility zone size (p < 0.013). No other strict cranial-caudal differences in kinematic outcomes were found. Low flexibility zone rotational stiffness increased with disc degeneration grade in extension, lateral bending and axial rotation (p < 0.001). Trends towards higher hysteresis and lower range of motion with increased degeneration were observed in flexion-extension and lateral bending. Applied compressive preload increased flexion-extension hysteresis and augmented the effect of degeneration on hysteresis (p < 0.0005). Female specimens had about one degree larger range of motion in all rotational modes, and higher flexion extension hysteresis (p = 0.016). These results suggest that gender differences exist in lumbar spine kinematics. Additionally high disc loads, applied compressive preload or applied moment, are needed to kinematically distinguish discs with different levels of degeneration. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:1389-1398, 2016.


Assuntos
Degeneração do Disco Intervertebral/fisiopatologia , Vértebras Lombares/fisiopatologia , Adulto , Idoso , Fenômenos Biomecânicos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Amplitude de Movimento Articular , Índice de Gravidade de Doença , Adulto Jovem
17.
Eur Spine J ; 25(7): 2155-65, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-26831539

RESUMO

PURPOSE: Patients with cervical spondylosis commonly present with neck pain, radiculopathy or myelopathy. As degenerative changes progress, multiple factors including disc height loss, thoracic kyphosis, and facetogenic changes can increase the risk of neural structure compression. This study investigated the impact of cervical deformity including forward head posture (FHP) and upper thoracic kyphosis, on the anatomy of the cervical neural foramen. METHODS: Postural changes of 13 human cervical spine specimens (Occiput-T1, age 50.6 years; range 21-67) were assessed in response to prescribed cervical sagittal malalignments using a previously reported experimental model. Two characteristics of cervical sagittal deformities, C2-C7 sagittal vertical alignment (SVA) and sagittal angle of the T1 vertebra (T1 tilt), were varied to create various cervical malalignments. The postural changes were documented by measuring vertebral positions and orientations. The vertebral motion data were combined with specimen-specific CT-based anatomical models, which allowed assessments of foraminal areas of subaxial cervical segments as a function of increasing C2-C7 SVA and changing T1 tilt. RESULTS: Increasing C2-C7 SVA from neutral posture resulted in increased neural foraminal area in the lower cervical spine (largest increase at C4-C5: 13.8 ± 15.7 %, P < 0.01). Increasing SVA from a hyperkyphotic posture (greater T1 tilt) also increased the neural foraminal area in the lower cervical segments (C5-C6 demonstrated the largest increase: 13.4 ± 9.6 %, P < 0.01). The area of the cervical neural foramen decreased with increasing T1 tilt, with greater reduction occurring in the lower cervical spine, specifically at C5-C6 (-8.6 ± 7.0 %, P < 0.01) and C6-C7 (-9.6 ± 5.6 %, P < 0.01). CONCLUSION: An increase in thoracic kyphosis (T1 tilt) decreased cervical neural foraminal areas. In contrast, an increase in cervical SVA increased the lower cervical neural foraminal areas. Patients with increased upper thoracic kyphosis may respond with increased cervical SVA as a compensatory mechanism to increase their lower cervical neural foraminal area.


Assuntos
Vértebras Cervicais/fisiopatologia , Cifose/fisiopatologia , Espondilose/fisiopatologia , Vértebras Torácicas/fisiopatologia , Adulto , Idoso , Fenômenos Biomecânicos , Vértebras Cervicais/diagnóstico por imagem , Feminino , Cabeça , Humanos , Cifose/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Modelos Anatômicos , Pescoço , Postura , Risco , Espondilose/diagnóstico por imagem , Vértebras Torácicas/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Adulto Jovem
18.
Spine (Phila Pa 1976) ; 41(10): E580-8, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26630432

RESUMO

STUDY DESIGN: A biomechanical study using human spine specimens. OBJECTIVE: The aim of this study was to assess whether the presence of cervical sagittal imbalance is an independent risk factor for increasing the mechanical burden on discs adjacent to cervical multilevel fusions. SUMMARY OF BACKGROUND DATA: The horizontal offset distance between the C2 plumbline and C7 vertebral body (C2-C7 Sagittal Vertical Axis (SVA)) or the angle made with vertical by a line connecting the C2 and C7 vertebral bodies (C2-C7 tilt angle) are used as radiographic measures to assess cervical sagittal balance. There is level III clinical evidence that sagittal imbalance caused by kyphotic fusions or global spinal sagittal malalignment may increase the risk of adjacent segment pathology. METHODS: Thirteen human cadaveric cervical spines (Occiput-T1; age: 50.6 years; range: 21-67) were tested first in the native intact state and then after instrumentation across C4-C6 to simulate in situ two-level fusion. Specimens were tested using a previously validated experimental model that allowed measurement of spinal response to prescribed imbalance. The effects of fusion on segmental angular alignments and intradiscal pressures in the C3-C4 and C6-C7 discs, above and below the fusion, were evaluated at different magnitudes of C2-C7 tilt angle (or C2-C7 SVA). RESULTS: When compared with the pre-fusion state, in situ fusion across C4-C6 segments required increased flexion angulation and resulted in increased intradiscal pressure at the C6-C7 disc below the fusion in order to accommodate the same increase in C2-C7 tilt angle or C2-C7 SVA (P < 0.05). The adjacent segment mechanical burden due to fusion became greater with increasing C2-C7 tilt angle or SVA. CONCLUSION: Cervical sagittal imbalance arising from regional and/or global spinal sagittal malalignment may play a role in exacerbating adjacent segment pathomechanics after multilevel fusion and should be considered during surgical planning. LEVEL OF EVIDENCE: N/A.


Assuntos
Fenômenos Biomecânicos , Vértebras Cervicais/diagnóstico por imagem , Vértebras Cervicais/cirurgia , Equilíbrio Postural , Amplitude de Movimento Articular , Fusão Vertebral/efeitos adversos , Adulto , Idoso , Fenômenos Biomecânicos/fisiologia , Vértebras Cervicais/fisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Equilíbrio Postural/fisiologia , Amplitude de Movimento Articular/fisiologia , Fatores de Risco , Adulto Jovem
19.
Spine (Phila Pa 1976) ; 40(11): 783-92, 2015 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-25768685

RESUMO

STUDY DESIGN: A biomechanical study using human spine specimens. OBJECTIVE: To study postural compensations in lordosis angles that are necessary to maintain horizontal gaze in the presence of forward head posture and increasing T1 sagittal tilt. SUMMARY OF BACKGROUND DATA: Forward head posture relative to the shoulders, assessed radiographically using the horizontal offset distance between the C2 and C7 vertebral bodies (C2-C7 [sagittal vertical alignment] SVA), is a measure of global cervical imbalance. This may result from kyphotic alignment of cervical segments, muscle imbalance, as well as malalignment of thoracolumbar spine. METHODS: Ten cadaveric cervical spines (occiput-T1) were tested. The T1 vertebra was anchored to a tilting and translating base. The occiput was free to move vertically but its angular orientation was constrained to ensure horizontal gaze regardless of sagittal imbalance. A 5-kg mass was attached to the occiput to mimic head weight. Forward head posture magnitude and T1 tilt were varied and motions of individual vertebrae were measured to calculate C2-C7 SVA and lordosis across C0-C2 and C2-C7. RESULTS: Increasing C2-C7 SVA caused flexion of lower cervical (C2-C7) segments and hyperextension of suboccipital (C0-C1-C2) segments to maintain horizontal gaze. Increasing kyphotic T1 tilt primarily increased lordosis across the C2-C7 segments. Regression models were developed to predict the compensatory C0-C2 and C2-C7 angulation needed to maintain horizontal gaze given values of C2-C7 SVA and T1 tilt. CONCLUSION: This study established predictive relationships between radiographical measures of forward head posture, T1 tilt, and postural compensations in the cervical lordosis angles needed to maintain horizontal gaze. The laboratory model predicted that normalization of C2-C7 SVA will reduce suboccipital (C0-C2) hyperextension, whereas T1 tilt reduction will reduce the hyperextension in the C2-C7 segments. The predictive relationships may help in planning corrective strategy in patients experiencing neck pain, which may be attributed to sagittal malalignment. LEVEL OF EVIDENCE: N/A.


Assuntos
Vértebras Cervicais/fisiopatologia , Lordose/fisiopatologia , Postura , Adulto , Fenômenos Biomecânicos , Cadáver , Vértebras Cervicais/diagnóstico por imagem , Cabeça , Humanos , Lordose/diagnóstico por imagem , Pessoa de Meia-Idade , Radiografia , Amplitude de Movimento Articular , Vértebras Torácicas/diagnóstico por imagem , Adulto Jovem
20.
J Biomech ; 45(13): 2289-92, 2012 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-22784652

RESUMO

Physiologic and kinetic joint simulators have been widely used for investigations of joint mechanics. The two types of simulator differ in the way joint motion is achieved; through prescribed motions and/or forces in kinetic joint simulators and by tendon loads in physiologic joint simulators. These two testing modalities have produced important insights, as in elucidating the importance of soft tissue structures to joint stability. However, the equivalence of the modalities has not been tested. This study sequentially tested five cadaveric elbows using both a physiologic simulator and a robot/6DOF system. Using position data from markers on the humerus and ulna, we calculated and compared the helical axes of motion of the specimens as the elbows were flexed from full extension. Six step size increments were used in the helical axis calculation. Marker position data at each test's full extension and full flexion point were also used to calculate a datum (overall) helical axis. The angles between the datum axis and step-wise movements were computed and stored. Increasing step size monotonically decreased the variability and the average conical angle encompassing the helical axes; a repeated measures ANOVA using test type (robot or physiologic simulator) and step size found that both type and step caused statistically significant differences (p<0.001). The large changes in helical axis angle observed for small changes in elbow flexion angle, especially in the robot tests, are a caveat for investigators using similar control algorithms. Controllers may need to include increased joint compliance and/or C(1) continuity to reduce variability.


Assuntos
Articulação do Cotovelo/fisiologia , Modelos Biológicos , Movimento/fisiologia , Amplitude de Movimento Articular/fisiologia , Tendões/fisiologia , Adulto , Idoso , Fenômenos Biomecânicos , Humanos , Cinética , Masculino , Pessoa de Meia-Idade , Robótica , Suporte de Carga
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...