Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 192
Filtrar
1.
Med Eng Phys ; 125: 104119, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38508799

RESUMO

OBJECTIVES: The cementless Oxford Unicompartmental Knee Replacement (OUKR) tibial component relies on an interference fit to achieve initial fixation. The behaviour at the implant-bone interface is not fully understood and hence modelling of implants using Finite Element (FE) software is challenging. With a goal of exploring alternative implant designs with lower fracture risk and adequate fixation, this study aims to investigate whether optimisation of FE model parameters could accurately reproduce experimental results of a pull-out test which assesses fixation. MATERIALS AND METHODS: Finite element models of implants with three methods of fixation (standard keel, small keel, and peg) in a bone analogue foam block were created, in which implants were modelled using an analytical rigid definition and the foam block was modelled as a homogenous linear isotropic material. The total interference and elastic slip were varied in these models and optimised by comparing simulated and experimental results of pull-out tests for two (standard and peg) implant geometries. Then the optimised interference and elastic slip were validated by comparing simulated and experimental data of a third (small keel) implant geometry. RESULTS: The optimisation of parameters established an interference of 0.16 mm and an elastic slip of 0.20 mm as most suitable for modelling the experimental force-displacement plots during pull-out. This combination of parameters accurately reproduced the experimental results of the small keel geometry. The maximum pull-out forces from the FE models were consistent with experimental data for each implant design. CONCLUSIONS: This study shows that experimental pull-out tests can be accurately modelled using adjusted interference values and non-linear friction and outlines a method for determining these parameters. This study demonstrates that complex problems in modelling implant behaviour can be addressed with relatively simple models. This can potentially lead to the development of implants with reduced risk of failure.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Análise de Elementos Finitos , Desenho de Prótese , Tíbia/cirurgia
2.
Knee Surg Sports Traumatol Arthrosc ; 32(3): 704-712, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38415874

RESUMO

PURPOSE: Cementless Oxford unicompartmental knee replacement (OUKR) is associated with less pain than cemented OUKR 5 years postoperatively. This may be due to improved fixation at the tibial wall, which transmits tension and reduces stress in the bone below the tibial component. This study compares tibial wall fixation with three different types of fixation: cemented, cementless with hydroxyapatite (HA) and cementless with a microporous titanium coat and HA (HA + MPC). METHODS: Three consecutive cohorts were identified (n = 221 cemented in 2005-2007, n = 118 HA in 2014-2015, n = 125 HA + MPC in 2016-2017). Analysis was performed on anterior-posterior radiographs aligned on the tibial component taken 1-2 years postoperatively. Aligned radiographs are needed to see narrow radiolucencies adjacent to the wall. Alignment was assessed with rotation ratio (RR = wall width/internal wall height). Perfect RR is 0.3, and a maximum threshold of 0.5 was used. Quality of fixation to the wall was assessed with fixation ratio (FR = bone wall contact height/total wall height). Notable radiographic features at the tibial wall were also recorded. RESULTS: A total of 33 knees with cement, 37 knees with cementless with HA and 57 knees cementless with HA + MPC had adequately aligned radiographs. Fixation was significantly better with HA compared with cement (55% vs. 25%, p = 0.0016). The microporous coat further improved fixation (81% vs. 55%, p < 0.0001). FR > 80% was achieved in 3% of the cemented implants, 32% of HA and 68% of HA + MPC. In cementless cohorts, features suggestive of a layer of bone that had delaminated from the wall were seen in 8 (22%) HA and 3 (5%) HA + MPC knees. CONCLUSION: Radiographic tibial wall fixation in OUKR is poor with cement. It improves with an HA coating and improves further with an intermediary MPC. Improved tibial wall fixation may explain the lower levels of pain observed with cementless rather than cemented fixation described in the literature, but further clinical correlation is needed. LEVEL OF EVIDENCE: Level III, retrospective cohort study.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Humanos , Titânio , Durapatita , Estudos Retrospectivos , Osteoartrite do Joelho/cirurgia , Resultado do Tratamento , Desenho de Prótese , Cimentos Ósseos , Dor/cirurgia , Falha de Prótese
3.
Knee Surg Sports Traumatol Arthrosc ; 32(2): 405-417, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38298004

RESUMO

PURPOSE: There is concern that using cementless components may increase polyethylene wear of the Oxford unicompartmental knee replacement (OUKR). Therefore, this study aimed to measure bearing wear at 10 years in patients from a randomized trial comparing Phase 3 cemented and cementless OUKRs and to investigate factors that may affect wear. It was hypothesized that there would be no difference in wear rate between cemented and cementless OUKRs. METHODS: Bearing thickness was determined using radiostereometric analysis at postoperative, 3-month, 6-month, 1-year, 2-year, 5-year and 10-year timepoints. As creep occurs early, wear rate was calculated using linear regression between 6 months and 10 years for 39 knees (20 cemented, 19 cementless). Associations between wear and implant, surgical and patient factors were analysed. RESULTS: The linear wear rate of the Phase 3 OUKR was 0.06 mm/year with no significant difference (p = 0.18) between cemented (0.054 mm/year) and cementless (0.063 mm/year) implants. Age, Oxford Knee Score, component size and bearing thickness had no correlation with wear. A body mass index ≥ 30 was associated with a significantly lower wear rate (p = 0.007) as was having ≥80% femoral component contact area on the bearing (p = 0.003). Bearings positioned ≥1.5 mm from the tibial wall had a significantly higher wear rate (p = 0.002). CONCLUSIONS: At 10 years, the Phase 3 OUKR linear wear rate is low and not associated with the fixation method. To minimize the risk of wear-related bearing fracture in the very long-term surgeons should consider using 4 mm bearings in very young active patients and ensure that components are appropriately positioned, which is facilitated by the current instrumentation. LEVEL OF EVIDENCE: Level III, retrospective comparative study.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Humanos , Artroplastia do Joelho/métodos , Polietileno , Estudos Retrospectivos , Osteoartrite do Joelho/cirurgia , Desenho de Prótese , Falha de Prótese , Resultado do Tratamento
4.
J Arthroplasty ; 2024 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-38355062

RESUMO

BACKGROUND: Periprosthetic fractures are rare but serious complications of unicompartmental knee arthroplasty (UKA). Although cementless UKA has a lower risk of loosening than cemented, there are concerns that tibial fracture risk may be higher given the reliance on interference fit for primary stability. The risk of fracture and the effect of surgical fixation are currently unknown. We compared the periprosthetic fracture rate following cemented and cementless UKA surgery. METHODS: A total of 14,122 medial mobile-bearing UKAs (7,061 cemented and 7,061 cementless) from the National Joint Registry and Hospital Episodes Statistics database were propensity score-matched. Cumulative fracture rates were calculated and Cox regressions were used to compare fixation groups. RESULTS: The three-month periprosthetic fracture rates were similar (P = .80), being 0.10% in the cemented group and 0.11% in the cementless group. The fracture rates were highest during the first three months postoperatively, but then decreased and remained constant between one and 10 years after surgery. The one-year cumulative fracture rates were 0.2% (confidence interval [CI]: 0.1 to 0.3) for cemented and 0.2% (CI: 0.1 to 0.3) for cementless cases. The 10-year cumulative fracture rates were 0.8% (CI: 0.2 to 1.3) and 0.8% (CI: 0.3 to 1.3), respectively. The hazard ratio during the whole study period was 1.06 (CI: 0.64 to 1.77; P = .79). CONCLUSIONS: The periprosthetic fracture rate following mobile bearing UKA surgery is low, being about 1% at 10 years. There were no significant differences in fracture rates between cemented and cementless implants after matching. We surmise that surgeons are aware of the higher theoretical risk of early fracture with cementless components and take care with tibial preparation. LEVELS OF EVIDENCE: III.

5.
J Arthroplasty ; 2023 Dec 04.
Artigo em Inglês | MEDLINE | ID: mdl-38056722

RESUMO

BACKGROUND: Periprosthetic fractures are serious complications of knee arthroplasty often requiring complex surgery. There is concern of increased periprosthetic fracture risk with cementless components given the reliance on interference fit for primary stability. It is unknown how the periprosthetic fracture risk compares between cemented and cementless total knee arthroplasties (TKAs). METHODS: A total of 22,477 cemented and 22,477 cementless TKAs from the National Joint Registry and Hospital Episodes Statistics database were propensity score matched on patient and surgical factors. Cumulative periprosthetic fracture rates were calculated using Kaplan-Meier analyses and compared with Cox regressions. Subgroup analyses were performed in different age, body mass index, and sex groups. RESULTS: The 3-month fracture rate in the cemented and cementless TKA groups were 0.02% and 0.04%, respectively. At 10 years, the cumulative fracture rate after cemented TKA was 1.2%, and after cementless was 1.4%. During the study period, there were no significant differences in fracture rates between cemented and cementless TKAs with a hazards ratio 1.14 (confidence interval 0.94 to 1.37, P = .20) at 10 years postoperatively. There were no significant differences in fracture rates between fixation types on subgroup analyses of sex, body mass index, and age groups. Female sex was a risk factor for fracture in both cemented (odds ratio 2.35, P < .001) and cementless TKAs (odds ratio 2.97, P < .001). CONCLUSIONS: The periprosthetic fracture rates following cemented and cementless TKA surgery are low being approximately 1.2% and 1.4%, respectively at 10 years. There were no significant differences in periprosthetic fracture rates requiring readmission between cemented and cementless TKAs. LEVEL OF EVIDENCE: III.

6.
JBJS Rev ; 11(12)2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-38100622

RESUMO

¼ This review of bone perfusion work introduces a new field of subchondral physiology.¼ Intraosseous pressure (IOP) measured through an intraosseous needle reflects conditions only at the needle tip rather than being a constant for the whole bone.¼ Measurements of IOP in vitro and in vivo, with and without proximal vascular occlusion, show that at rest, bone is perfused at normal physiological pressures.¼ A subtraction perfusion range or bandwidth at the needle tip offers a better measure of bone health than a single IOP.¼ With ordinary loads, very great subchondral pressures are generated.¼ Subchondral tissues are relatively delicate but are microflexible with bone fat being essentially liquid at body temperature.¼ Collectively, the subchondral tissues transmit load mainly through hydraulic pressure to the trabeculae and cortical shaft.¼ White vascular marks on normal magnetic resonance imaging scans are present but are lost in early osteoarthritis.¼ Histological studies confirm the presence of those vascular marks and also choke valves capable of supporting hydraulic pressure load transmission.¼ Osteoarthritis seems to be at least partly a vasculomechanical disease.¼ Understanding subchondral physiology will be key to better classification, control, prognosis, and treatment of osteoarthritis.


Assuntos
Osteoartrite , Humanos , Imageamento por Ressonância Magnética/métodos , Osso e Ossos
7.
Knee Surg Sports Traumatol Arthrosc ; 31(12): 5407-5412, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37768357

RESUMO

PURPOSE: Lateral osteoarthritis following medial unicompartmental knee replacement (UKR) is usually treated with total knee replacement, however, lateral UKR is a less invasive option that preserves a well-functioning medial UKR. This study aimed to determine the 5-year outcome of the cemented Fixed Lateral Oxford UKR (FLO) when used for the treatment of severe lateral disease after medial Oxford unicompartmental knee replacement. METHODS: Forty-four knees with lateral bone-on-bone osteoarthritis (n = 43) and avascular necrosis (n = 1) treated with the FLO following medial Oxford UKR were followed up prospectively. The Oxford Knee Score (OKS) and Tegner Activity Score (TAS) were collected pre- and post-operatively. Life-table analysis was used to determine survival rates. RESULTS: The mean patient age at the time of FLO surgery was 74.4 years with a mean time of 12.1 years between the primary medial UKR and the conversion to a bi-UKR with a FLO. Mean follow-up of the FLO was 3.5 years. After FLO no intra-operative or medical complications, re-admissions, or mortality occurred. There was one reoperation in which a bearing was exchanged for a medial bearing dislocation. There were no revisions of the FLO, so the FLO survival rate at 5 years was 100% (24 at risk). The mean pre-operative OKS was 22, which significantly (p < 0.0001) improved to a mean of 42, 42, and 40 at 1, 2, and 5 years, respectively. The median TAS had a non-significant improvement from 2.5 (Range 0-8) pre-operatively to 2 (Range 1-6) at 5 years postoperatively. CONCLUSION: The FLO is a reliable treatment for lateral osteoarthritis following medial UKR. At 5 years there was a 100% survival of the FLO with a mean OKS of 40. LEVEL OF EVIDENCE: IV, Prospective Case Series.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Humanos , Idoso , Artroplastia do Joelho/efeitos adversos , Osteoartrite do Joelho/cirurgia , Escore de Lysholm para Joelho , Reoperação , Resultado do Tratamento
8.
J Bone Joint Surg Am ; 105(23): 1857-1866, 2023 12 06.
Artigo em Inglês | MEDLINE | ID: mdl-37733918

RESUMO

BACKGROUND: Periprosthetic fractures are rare but devastating complications of knee replacement, often requiring complex surgery with substantial morbidity and mortality. It is not known how the fracture rates after total knee replacement (TKR) and unicompartmental knee replacement (UKR) compare. We performed the first matched study comparing TKR and UKR periprosthetic fracture rates. METHODS: This study involved 54,215 UKRs and 54,215 TKRs, identified in the National Joint Registry and Hospital Episodes Statistics database, which were propensity score-matched on patient and surgical factors. The International Classification of Diseases, Tenth Revision, (ICD-10) code M96.6 was used to identify periprosthetic fractures at ≤3 and >3 months postoperatively, as well as estimate rates at up to 10 years. Subgroup analyses were performed in different age groups (<55, 55 to 64, 65 to 74, and ≥75 years), body mass index (BMI) categories (normal, 18.5 to <25 kg/m 2 ; overweight, 25 to <30 kg/m 2 ; obese, 30 to <40 kg/m 2 ; and morbidly obese, ≥40 kg/m 2 ), and sexes. RESULTS: The 3-month fracture rate was 0.09% (n = 50) in the UKR group and 0.05% (n = 25) in the TKR group, with this difference being significant (odds ratio [OR], 2.0; p = 0.004). The rate of fractures occurring at >3 months was 0.32% (n = 171) in the UKR group and 0.61% (n = 329) in the TKR group (OR, 0.51; p < 0.001). At 10 years, the cumulative incidence of fractures was 0.6% after UKR versus 1% after TKR (OR, 0.68; p < 0.001). Fracture rates increased with increasing age, decreasing BMI, and female sex for both UKRs and TKRs. CONCLUSIONS: The fracture risk was small after both UKR and TKR, with small absolute differences between implant types. During the first 3 postoperative months, the fracture rate after UKR was 0.1% and was about twice as high as that after TKR. However, over the first 10 years, the cumulative fracture rate after TKR was 1% and was almost twice as high as that after UKR. Fracture rates after both UKR and TKR were higher in women, patients ≥75 years of age, and patients with normal weight. LEVEL OF EVIDENCE: Therapeutic Level III . See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Obesidade Mórbida , Osteoartrite do Joelho , Fraturas Periprotéticas , Humanos , Feminino , Idoso , Artroplastia do Joelho/efeitos adversos , País de Gales/epidemiologia , Irlanda do Norte/epidemiologia , Fraturas Periprotéticas/epidemiologia , Fraturas Periprotéticas/etiologia , Fraturas Periprotéticas/cirurgia , Reoperação , Falha de Prótese , Inglaterra/epidemiologia , Sistema de Registros , Prótese do Joelho/efeitos adversos , Osteoartrite do Joelho/epidemiologia , Osteoartrite do Joelho/cirurgia
9.
Proc Inst Mech Eng H ; 237(10): 1167-1176, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37776125

RESUMO

Mobile bearing dislocation occurs in 1- 6% of Oxford Domed Lateral replacements. Dislocations are predominantly medial, but can occur anteriorly or posteriorly. They tend to occur when the knee is flexed. It is not clear how dislocations can be prevented. A previously described mechanical rig for assessing mobile bearing dislocation was updated so as to study dislocation with the knee in flexion. Sub-categories for the description of each type of dislocation were introduced. Dislocation was only possible when the knee was distracted. As the amount of distraction possible in the knee is variable, the risk of dislocation is related to the amount of distraction in the rig necessary for a dislocation. The type of dislocation requiring the least distraction was medial `edge' dislocation in which the edge of the bearing dislocates onto the tibial wall, which is the most common type of dislocation. The amount of distraction necessary decreased the further the bearing was from the wall and with 50% posterior overhang. Rotation of the knee did not influence the amount of distraction. In conclusion dislocation can only occur if the lateral compartment is distracted. To reduce the dislocation risk, surgeons should aim to position the femoral and tibial components so that the bearing is as close as possible to the wall without jamming against it and the tibial component should be positioned flush with the posterior tibial cortex. If, during the surgery, the mobile bearing can easily be dislocated onto the wall the surgeon should consider changing to a fixed bearing. The tibial component should also be positioned flush with the posterior tibial cortex, as if it is too far forward this may contribute to dislocation.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Humanos , Articulação do Joelho/cirurgia , Tíbia/cirurgia , Fêmur/cirurgia , Desenho de Prótese
10.
Knee Surg Sports Traumatol Arthrosc ; 31(11): 5180-5189, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37776359

RESUMO

PURPOSE: To compare patient-reported pain scores and assess the influence of neuropathy and co-morbidity, on knee pain following cemented and cementless medial unicompartmental knee replacement (UKR) 5 years after surgery. METHOD: In this longitudinal study, 262 cemented and 262 cementless Oxford UKR performed for the same indications and with the same techniques were recruited. Patients were reviewed at five years, evaluating patient-reported pain and association with clinical outcomes. Intermittent and Constant Osteoarthritis Pain (ICOAP), PainDETECT (PD), Charnley score, Oxford Knee Score (OKS) and American Knee Society Score (AKSS) were compared. RESULTS: In both cohorts, intermittent pain was more common than constant pain (47% vs 21%). Cementless knees reported significantly less pain than cemented (ICOAP-Total 5/100 vs 11/100, p < 0.0001). A greater proportion of cementless knees experienced no pain at all (ICOAP = 0/100, 61% vs 43%, p < 0.0001) and 75% fewer experienced severe or extreme pain. Pain sub-scores in PD, OKS and AKSS follow this trend. Pain was unlikely to be neuropathic (PD positive: 5.26%), but patients reporting high levels of 'strongest' pain were three times more likely to be neuropathic. Patients with co-morbidities (Charnley C) experienced greater pain than those without (Charnley A+B) across all knee-specific scores, despite scores being knee specific. CONCLUSION: Both cemented and cementless UKR in this study had substantially less pain than that reported in literature following TKR. Cementless UKR had significantly less pain than cemented UKR in all scores. Two-thirds of patients with a cementless UKR had no pain at all at 5 years, and pain experienced was most likely to be mild and intermittent with no patients in severe or extreme pain. Patients with cementless UKR that had higher levels of pain were more likely to have co-morbidity or evidence or neuropathic pain. It is unclear why cementless UKR have less pain than cemented; further study is necessary.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Humanos , Artroplastia do Joelho/efeitos adversos , Artroplastia do Joelho/métodos , Prótese do Joelho/efeitos adversos , Estudos Longitudinais , Osteoartrite do Joelho/cirurgia , Dor/cirurgia , Morbidade , Resultado do Tratamento , Reoperação
11.
EFORT Open Rev ; 8(6): 436-442, 2023 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-37289053

RESUMO

This review of bone perfusion introduces a new field of joint physiology, important in understanding osteoarthritis. Intraosseous pressure (IOP) reflects conditions at the needle tip rather than being a constant for the whole bone. Measurements of IOP in vitro and in vivo, with and without proximal vascular occlusion confirm that cancellous bone is perfused at normal physiological pressures. Alternate proximal vascular occlusion may be used to give a perfusion range or bandwidth at the needle tip more useful than a single IOP measure. Bone fat is essentially liquid at body temperature. Subchondral tissues are relatively delicate but are micro-flexible. They tolerate huge pressures with loading. Collectively, the subchondral tissues transmit load mainly by hydraulic pressure to the trabeculae and cortical shaft. Normal MRI scans demonstrate subchondral vascular marks which are lost in early osteoarthritis. Histological studies confirm the presence of those marks and possible subcortical choke valves which support hydraulic pressure load transmission. Osteoarthritis appears to be at least partly a vasculo-mechanical disease. Understanding subchondral vascular physiology will be key to better MRI classification and prevention, control, prognosis and treatment of osteoarthritis and other bone diseases.

12.
Bone Jt Open ; 4(3): 210-218, 2023 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-37051833

RESUMO

To assess the incidence of radiological lateral osteoarthritis (OA) at 15 years after medial unicompartmental knee arthroplasty (UKA) and assess the relationship of lateral OA with symptoms and patient characteristics. Cemented Phase 3 medial Oxford UKA implanted by two surgeons since 1998 for the recommended indications were prospectively followed. A 15-year cumulative revision rate for lateral OA of 5% for this series was previously reported. A total of 163 unrevised knees with 15-year (SD 1) anterior-posterior knee radiographs were studied. Lateral joint space width (JSWL) was measured and severity of lateral OA was classified as: nil/mild, moderate, and severe. Preoperative and 15-year Oxford Knee Scores (OKS) and American Knee Society Scores were determined. The effect of age, sex, BMI, and intraoperative findings was analyzed. Statistical analysis included one-way analysis of variance and Kruskal-Wallis H test, with significance set at 5%. The mean age was 80.6 years (SD 8.3), with 84 females and 79 males. The mean JSWL was 5.6 mm (SD 1.4), and was not significantly related to age, sex, or intraoperative findings. Those with BMI > 40 kg/m2 had a smaller JSWL than those with a 'normal' BMI (p = 0.039). The incidence of severe and moderate lateral OA were both 4.9%. Overall, 2/142 (1.4%) of those with nil/mild lateral OA, 1/8 (13%) with moderate, and 2/8 (25%) with severe subsequently had a revision. Those with severe (mean OKS 35.6 (SD 9.3)) and moderate OA (mean OKS 35.8 (SD 10.5)) tended to have worse outcome scores than those with nil/mild (mean OKS 39.5 (SD 9.2)) but the difference was only significant for OKS-Function (p = 0.044). This study showed that the rate of having severe or moderate radiological lateral OA at 15 years after medial UKA was low (both 4.9%). Although patients with severe or moderate lateral OA had a lower OKS than those with nil/mild OA, their mean scores (OKS 36) would be classified as good.

13.
J Bone Joint Surg Am ; 105(7): 527-536, 2023 04 05.
Artigo em Inglês | MEDLINE | ID: mdl-36881643

RESUMO

BACKGROUND: Unicompartmental knee replacements (UKRs) are being performed in an increasingly overweight population. There are concerns that cemented fixation will not last. Cementless fixation may offer a solution, but the relative performance in different body mass index (BMI) groups remains unknown. METHODS: Ten thousand, four hundred and forty cemented and cementless UKRs were propensity matched. Patients were stratified into 4 BMI groups: underweight (<18.5 kg/m 2 ), normal weight (18.5 to <25 kg/m 2 ), overweight (25 to <30 kg/m 2 ), and obese (≥30 kg/m 2 ). The effect of BMI on the relative performance of UKR fixation groups was studied. Cox regression was used to compare revision and reoperation rates. RESULTS: The revision rate per 100 component-years significantly increased (p < 0.001) with BMI for the cemented UKRs. Revision rates per 100 component-years for the normal, overweight, and obese groups were 0.92 (95% confidence interval [CI], 0.91 to 0.93), 1.15 (95% CI, 1.14 to 1.16), and 1.31 (95% CI, 1.30 to 1.33), respectively. This was not observed for the cementless UKR, with revision rates of 1.09 (95% CI, 1.08 to 1.11), 0.70 (95% CI, 0.68 to 0.71), and 0.96 (95% CI, 0.95 to 0.97), respectively. The 10-year implant survival rates for the matched cemented and cementless UKRs in the normal, overweight, and obese groups were 93.8% (95% CI, 89.1% to 96.5%) and 94.3% (95% CI, 90.9% to 96.5%) (hazard ratio [HR], 1.17; p = 0.63), 88.5% (95% CI, 84.2% to 91.7%) and 93.8% (95% CI, 90.2% to 96.2%) (HR, 0.61; p = 0.005), and 90.7% (95% CI, 88.2% to 92.6%) and 91.8% (95% CI, 88.9% to 94.0%) (HR, 0.74; p = 0.02), respectively. There were insufficient numbers in the underweight group for analysis (n = 13). Obese patients had less than half the rates of aseptic loosening (0.46% vs. 1.31%; p = 0.001) and pain (0.60% vs. 1.20%; p = 0.02) in the cementless group as compared with the cemented group. CONCLUSIONS: Higher-BMI groups had higher revision rates for the cemented UKRs but not for the cementless UKRs. Cementless fixation was associated with reduced long-term revision rates compared with cement fixation in the overweight and obese groups. In the obese group, the rates of aseptic loosening and pain were at least 50% lower in the cementless UKR group. LEVEL OF EVIDENCE: Prognostic Level III . See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Prótese do Joelho , Humanos , Índice de Massa Corporal , Sobrepeso , Magreza , Falha de Prótese , Desenho de Prótese , Reoperação , Obesidade , Cimentos Ósseos , Resultado do Tratamento
14.
J Arthroplasty ; 38(1): 30-36.e1, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35952853

RESUMO

BACKGROUND: Unicompartmental knee arthroplasty (UKA) is an effective treatment for medial compartment arthritis. A challenge is that patients requiring knee arthroplasty are becoming younger. It is currently unknown what the relative performances of cemented and cementless UKAs are, in different age groups. METHODS: A total of 12,882 cemented and cementless UKAs from the National Joint Registry and Hospital Episodes Statistics databases were matched on patient and surgical factors. Patients were stratified into 3 groups: (1) <60 years; (2) 60-69 years; and (3) ≥70 years. Revision and reoperation rates were compared using Cox regression analyses. RESULTS: The 10-year implant survival for the matched cemented and cementless UKAs for (1) <60 years were 81.4% (CI 73.6-87.0) and 86.7% (CI 80.7-90.9) (hazard ratio [HR] 0.73, CI 0.56-0.94, P = .02); (2) for 60-69 years were 91.8% (CI 88.9-94.0) and 94.5% (CI 92.9-95.7) (HR 0.90, CI 0.67-1.22, P = .51); and (3) ≥70 years were 93.5% (CI 91.1-95.3) and 94.2% (CI 92.0-95.8) (HR 1.0, CI 0.71-1.40, P = .99). The same trend was observed for reoperations. In the <60 years and 60-69 years groups there were significantly fewer revisions for aseptic loosening in the cementless group (0.5% versus 1.6% [P < .001] and 0.4% versus 1.3% [P = .002], respectively). CONCLUSION: Younger ages were associated with higher revision rates in both cemented and cementless UKA groups. Cementless fixation has reduced long-term revision rates compared to cemented fixation in the <60 years group with aseptic loosening rates 3 times lower. LEVEL OF EVIDENCE: III.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Humanos , Desenho de Prótese , Falha de Prótese , Reoperação , Sistema de Registros , Resultado do Tratamento , Osteoartrite do Joelho/cirurgia
15.
Knee Surg Sports Traumatol Arthrosc ; 31(3): 986-997, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36063186

RESUMO

PURPOSE: Unicompartmental knee arthroplasty (UKA) is an effective treatment for late knee osteoarthritis (OA). Young age (< 60 years) has been associated with worse outcomes. The goal of this systematic review and meta-analysis is to study the effect of age on UKA outcomes. METHODS: The primary objective was to compare the UKA revision rate in young patients with that of old patients, using the age thresholds of 60 and 55 years. Secondary objectives were patient-reported outcome measures (PROMs) and implant design. Five databases were searched in December 2021 for original comparative studies with a minimum of 1-year follow-up. No restrictions were placed on the type of UKA prosthesis. RESULTS: A total of 11 observational studies with 6130 knees were included. A mean MINORS score of 19 was assigned to the review. The mean age of patients was 64 years, with average follow-up of 7.5 ± 2.98 years. There was no significant difference in revision rate, incident or PROMs between young and old patients in the analysis for each age threshold. Further sub-analysis adjusting for implant type in mobile- and fixed-bearing prostheses also showed similar results between those above and under 60 and 55 years. CONCLUSION: Young age was not associated with a higher revision rate or lower functional scores. Thus, this review provides evidence that age alone is not a contraindication to UKA, but the surgical choice must be based on several elements, and this finding should be applied in context, given the binary division and heterogeneity of patients. LEVEL OF EVIDENCE: III.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Humanos , Pessoa de Meia-Idade , Artroplastia do Joelho/métodos , Reoperação , Osteoartrite do Joelho/cirurgia , Resultado do Tratamento , Articulação do Joelho/cirurgia
16.
J Arthroplasty ; 38(2): 245-251, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-35964854

RESUMO

BACKGROUND: Unicompartmental knee arthroplasty (UKA) revision rates are variable and known to be influenced by a surgeon's caseload (number of UKAs performed annually) and usage (UKA as a proportion of overall knee arthroplasty practice). It is not known which is more important. We explored the influence of caseload and usage on cemented and cementless UKA. METHODS: A total of 34,277 medial Oxford UKAs (23,707 cemented and 10,570 cementless) from the National Joint Registry were analyzed. UKAs were subdivided by the following: (1) surgeon caseload, into low (<10 UKAs/y) and high (≥10 UKAs/y) categories; and (2) usage, into low (<20%) and high (≥20%) categories. The 10-year revision rates were compared. RESULTS: The 10-year survival of the low-caseload/low-usage cemented and cementless UKA was 82.8% (CI 81.6-83.9) and 86.2% (CI 72.1-93.4), respectively. The 10-year survival of the high-caseload/high-usage cemented and cementless UKA was 90.0% (CI 89.2-90.6) and 93.3% (CI 91.3-94.8), respectively. For cemented UKA, the high-caseload/high-usage group had lower revision rates (hazard ratio [HR] 0.57, CI 0.52-0.63, P < .001) compared to the low-caseload/low-usage group. The high-caseload/low-usage (HR 0.74, CI 0.66-0.83, P < .001) and the low-caseload/high-usage (HR 0.86, CI 0.74-0.99, P = .04) groups also had lower revision rates than the low-caseload/low-usage group. CONCLUSION: Mobile-bearing UKA revision rates improve with both increasing surgeon UKA caseload and usage. Surgeons using cemented UKA who have usage ≥20% and caseload ≥10/year had a 10-year survival of 90%. Higher survivorship was associated with higher caseload, higher usage, and cementless fixation. LEVELS OF EVIDENCE: III.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Cirurgiões , Humanos , País de Gales , Irlanda do Norte/epidemiologia , Falha de Prótese , Reoperação , Inglaterra , Sistema de Registros , Osteoartrite do Joelho/cirurgia , Resultado do Tratamento
17.
Acta Orthop ; 93: 478-487, 2022 05 24.
Artigo em Inglês | MEDLINE | ID: mdl-35611477

RESUMO

BACKGROUND AND PURPOSE: The main treatments for severe medial compartment knee arthritis are unicompartmental (UKR) and total knee replacement (TKR). UKRs have higher revision rates, particularly for aseptic loosening, therefore the cementless version was introduced. We compared the outcomes of matched cementless UKRs and TKRs. PATIENTS AND METHODS: The National Joint Registry was linked to the English Hospital Episode Statistics and Patient Reported Outcome Measures (PROMs) databases. 10,552 cementless UKRs and 10,552 TKRs were propensity matched and regression analysis used to compare revision/reoperation risks. 6-month PROMs were compared. UKR results were stratified by surgeon caseload into low- (< 10 UKRs/year), medium- (10 to < 30 UKRs/year), and high-volume (≥ 30 UKRs/year). RESULTS: 8-year cementless UKR revision survival for the 3 respective caseloads were 90% (95% CI 87-93), 93% (CI 91-95), and 96% (CI 94-97). 8-year reoperation survivals were 76% (CI 71-80), 81% (CI 78-85), and 84% (CI 82-86) respectively. For TKR the 8-year implant survivals for revision and reoperation were 96% (CI 95-97) and 81% (CI 80-83). The HRs for the 3 caseload groups compared with TKR for revision were 2.0 (CI 1.3-2.9), 2.0 (CI 1.6-2.7), and 1.0 (CI 0.8-1.3) and for reoperation were 1.2 (CI 1.0-1.4), 0.9 (CI 0.8-1.0), and 0.6 (CI 0.5-0.7). 6-month Oxford Knee Score (OKS) (39 vs. 37) and EQ-5D (0.80 vs. 0.77) were higher (p < 0.001) for the cementless UKR. INTERPRETATION: Cementless UKRs have higher revision and reoperation rates than TKR for low-volume UKR surgeons, similar reoperation but higher revision rates for mid-volume surgeons, and lower reoperation and similar revision rates for high-volume surgeons. Cementless UKR also had better PROMs.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Artroplastia do Joelho/efeitos adversos , Inglaterra/epidemiologia , Humanos , Prótese do Joelho/efeitos adversos , Irlanda do Norte/epidemiologia , Osteoartrite do Joelho/cirurgia , Falha de Prótese , Sistema de Registros , Reoperação , País de Gales/epidemiologia
18.
JAMA Surg ; 157(6): 481-489, 2022 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-35385072

RESUMO

Importance: More than half of patients who undergo knee replacement surgery report substantial acute postoperative pain. Objective: To evaluate the efficacy and cost-effectiveness of periarticular liposomal bupivacaine for recovery and pain management after knee replacement. Design, Setting, and Participants: This multicenter, patient-blinded, pragmatic, randomized clinical superiority trial involved 533 participants at 11 institutions within the National Health Service in England. Adults undergoing primary unilateral knee replacement for symptomatic end-stage osteoarthritis were enrolled between March 29, 2018, and February 29, 2020, and followed up for 1 year after surgery. Follow-up was completed March 1, 2021. A per-protocol analysis for each coprimary outcome was performed in addition to the main intention-to-treat analysis. Interventions: Two hundred sixty-six milligrams of liposomal bupivacaine admixed with 100 mg of bupivacaine hydrochloride compared with 100 mg of bupivacaine hydrochloride alone (control) administered by periarticular injection at the time of surgery. Main Outcome and Measures: The coprimary outcomes were Quality of Recovery 40 (QoR-40) score at 72 hours and pain visual analog scale (VAS) score area under the curve (AUC) from 6 to 72 hours. Secondary outcomes included QoR-40 and mean pain VAS at days 0 (evening of surgery), 1, 2, and 3; cumulative opioid consumption for 72 hours; functional outcomes and quality of life at 6 weeks, 6 months, and 1 year; and cost-effectiveness for 1 year. Adverse events and serious adverse events up to 12 months after randomization were also assessed. Results: Among the 533 participants included in the analysis, the mean (SD) age was 69.0 (9.7) years; 287 patients were women (53.8%) and 246 were men (46.2%). Baseline characteristics were balanced between study groups. There was no difference between the liposomal bupivacaine and control groups in QoR-40 score at 72 hours (adjusted mean difference, 0.54 [97.5% CI, -2.05 to 3.13]; P = .64) or the pain VAS score AUC at 6 to 72 hours (-21.5 [97.5% CI, -46.8 to 3.8]; P = .06). Analyses of pain VAS and QoR-40 scores demonstrated only 1 statistically significant difference, with the liposomal bupivacaine arm having lower pain scores the evening of surgery (adjusted difference -0.54 [97.5% CI, -1.07 to -0.02]; P = .02). No difference in cumulative opioid consumption and functional outcomes was detected. Liposomal bupivacaine was not cost-effective compared with the control treatment. No difference in adverse or serious adverse events was found between the liposomal bupivacaine and control groups. Conclusions and Relevance: This study found no difference in postoperative recovery or pain associated with the use of periarticular liposomal bupivacaine compared with bupivacaine hydrochloride alone in patients who underwent knee replacement surgery. Trial Registration: isrctn.com Identifier: ISRCTN54191675.


Assuntos
Analgésicos Opioides , Bupivacaína , Adulto , Idoso , Analgésicos Opioides/uso terapêutico , Anestésicos Locais , Feminino , Humanos , Lipossomos/uso terapêutico , Masculino , Dor Pós-Operatória/tratamento farmacológico , Qualidade de Vida , Medicina Estatal
19.
J Orthop Surg Res ; 17(1): 146, 2022 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-35248092

RESUMO

BACKGROUND: Isolated lateral compartment knee arthritis is less prevalent than medial. While the reported results of medial unicompartmental knee replacement (UKR) have been good and comparable to total knee replacement, the results of lateral UKR have been mixed. We present the short-term results and survivorship of a fixed-bearing UKR designed specifically for the lateral compartment. METHODS: We report the result of 130 primary fixed-bearing lateral Oxford (FLO) UKRs (123 patients) performed between 2015 and 2019 with a minimum follow-up of 1 year. The indications for lateral UKR were: isolated lateral osteoarthritis (n = 122), post-trauma (n = 5) and osteonecrosis (n = 3). The mean age was 69.1 (± 11.6), mean BMI 28.4 (± 4.9), 66.9% female, 60% right-sided, and mean follow-up 3 (range 1-4.8 years, standard deviation ± 1) years. The primary outcome measure was the Oxford knee score (OKS). Survival analysis was performed with "revision for any reason", "reoperation", and "implant failure" as the endpoints. RESULTS: Six patients died from unrelated reasons. None of the implants failed. One required the addition of a medial UKR for medial arthritis. There were no other reoperations. At 4 years, the survival for implant failure was 100% and for both revision and all reoperations was 99.5% (95% CI 96.7-99.9%). At the last review, at a mean of 3 years, the mean Oxford knee score was 41. CONCLUSION: The good survivorship and outcome scores suggest that UKR designed for the lateral compartment is an excellent alternative to total knee replacement in selected patients with isolated lateral tibiofemoral arthritis at short-term follow-up.


Assuntos
Artroplastia do Joelho/métodos , Articulação do Joelho/cirurgia , Prótese do Joelho , Osteoartrite do Joelho/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Falha de Prótese , Reoperação , Resultado do Tratamento
20.
Sci Rep ; 12(1): 2068, 2022 02 08.
Artigo em Inglês | MEDLINE | ID: mdl-35136092

RESUMO

Due to ligament laxity, bearing dislocation occurs in 1-6% of Oxford Domed Lateral (ODL) replacements with most dislocations occurring medially. Dislocations were studied using a previously built mechanical rig, however testing using the rig was inefficient. The aim of this study was to develop a better tool that was more reliable and efficient. An established robotics software package, the Open Motion Planning Library, was modified to accept the ODL components. Using a robotics path planning algorithm, the mobile bearing was allowed to find a way out from between the femoral and tibial components i.e. to dislocate. Testing assessed a range of clinically relevant positions of the femoral component relative to the tibial component. Dislocations were labelled as medial, lateral, anterior or posterior depending on the dislocation direction. The Distraction to Dislocation (DD) measured the minimum vertical distraction of the femoral component from the tibial component for a dislocation to occur. Results were validated against the mechanical rig. Statistical analysis of medial dislocation showed excellent agreement with an intraclass correlation value of 0.993 (95% CI 0.982-0.998). All DDs from the dislocation analysis tool were within 1 mm of the mechanical rig DDs with results sharing a remarkably similar trend. The robotics dislocation analysis tool output DDs which were marginally higher than the manual mechanical rig: 0.50 mm anteriorly, 0.25 mm posteriorly and 0.50 mm laterally. Medially, the computational DD differed on average by 0.09 mm (stand deviation: 0.2026 mm). Our study describes the development and validation of a novel robotics dislocation analysis tool, which allows mobile bearing dislocation risk quantification. The tool may also be used to improve surgical implantation parameters and to assess new implant designs that aim to reduce the medial dislocation risk to an acceptable level.


Assuntos
Artroplastia do Joelho/efeitos adversos , Artroplastia do Joelho/métodos , Luxação do Joelho/prevenção & controle , Prótese do Joelho , Procedimentos Cirúrgicos Robóticos/métodos , Algoritmos , Engenharia Biomédica/métodos , Humanos , Luxação do Joelho/diagnóstico , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/cirurgia , Desenho de Prótese , Pesquisa Translacional Biomédica/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...