Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anal Chem ; 94(29): 10443-10450, 2022 07 26.
Artigo em Inglês | MEDLINE | ID: mdl-35696545

RESUMO

Total and differential white blood cell (WBC) counts are vital metrics used routinely by clinicians to aid in the identification of diseases. However, the equipment necessary to perform WBC counts restricts their operation to centralized laboratories, greatly limiting their accessibility. Established solutions for the development of point-of-care assays, namely lateral flow tests and paper-based microfluidic devices, are inherently limited in their ability to support the detection of WBCs─the pore sizes of materials used to fabricate these devices (e.g., membranes or chromatography papers) do not permit passive WBC transport via wicking. Herein, we identify a material capable of the unimpeded transport of WBCs in both lateral and vertical directions: a coffee filter. Through in situ labeling with an enzyme-labeled affinity reagent, our paper-based cytometer detects WBCs according to their immunophenotype. Using two cultured leukocyte lines (Jurkat D1.1 T cells and MAVER-1 B cells), we demonstrate the specific, colorimetric enumeration of each target cell population across the expected physiological range for total lymphocytes, 1000-4000 cells µL-1. Additionally, we highlight a potential application of this type of device as a screening tool for detecting abnormal cell counts outside the normal physiological range and in subclasses of cell types, which could aid in the identification of certain diseases (e.g., CD4+ T lymphocytes, an important biomarker for HIV disease/AIDS). These results pave the way for a new class of paper-based devices─those capable of controlled white blood cell transport, labeling, capture, and detection─thus expanding the opportunities for low-cost, point-of-care cytometers.


Assuntos
Infecções por HIV , Leucócitos , Linfócitos T CD4-Positivos , Humanos , Imunofenotipagem , Contagem de Leucócitos
2.
Anal Bioanal Chem ; 413(14): 3695-3706, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33852053

RESUMO

During epidemics, such as the frequent and devastating Ebola virus outbreaks that have historically plagued regions of Africa, serological surveillance efforts are critical for viral containment and the development of effective antiviral therapeutics. Antibody serology can also be used retrospectively for population-level surveillance to provide a more complete estimate of total infections. Ebola surveillance efforts rely on enzyme-linked immunosorbent assays (ELISAs), which restrict testing to laboratories and are not adaptable for use in resource-limited settings. In this manuscript, we describe a paper-based immunoassay capable of detecting anti-Ebola IgG using Ebola virus envelope glycoprotein ectodomain (GP) as the affinity reagent. We evaluated seven monoclonal antibodies (mAbs) against GP-KZ52, 13C6, 4G7, 2G4, c6D8, 13F6, and 4F3-to elucidate the impact of binding affinity and binding epitope on assay performance and, ultimately, result interpretation. We used biolayer interferometry to characterize the binding of each antibody to GP before assessing their performance in our paper-based device. Binding affinity (KD) and on rate (kon) were major factors influencing the sensitivity of the paper-based immunoassay. mAbs with the best KD (3-25 nM) exhibited the lowest limits of detection (ca. µg mL-1), while mAbs with KD > 25 nM were undetectable in our device. Additionally, and most surprisingly, we determined that observed signals in paper devices were directly proportional to kon. These results highlight the importance of ensuring that the quality of recognition reagents is sufficient to support desired assay performance and suggest that the strength of an individual's immune response can impact the interpretation of assay results.


Assuntos
Ebolavirus/isolamento & purificação , Doença pelo Vírus Ebola/diagnóstico , Técnicas Analíticas Microfluídicas/instrumentação , Anticorpos Antivirais/imunologia , Ebolavirus/imunologia , Desenho de Equipamento , Doença pelo Vírus Ebola/imunologia , Humanos , Imunoensaio/instrumentação , Proteínas do Envelope Viral/imunologia
3.
Anal Chim Acta ; 1140: 236-249, 2020 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-33218486

RESUMO

Due to their portability, versatility for supporting multiple assay formats, and potential for resulting in low-cost assays, paper-based analytical devices (PADs) are an increasingly popular format as a platform for the development of point-of-care tests. However, very few PADs have been translated successfully to their intended environments outside of academic settings. Often overlooked as a factor that inhibits translation, usability is a vital characteristic of any successful point-of-care test. Recent advancements in PAD design have demonstrated improved usability by simplifying various aspects of user operation, including sample collection, sample processing, device operation, detection, and readout/interpretation. Field testing at various stages of device design can offer critical feedback about device usability, especially when it involves the proposed end-user or other stakeholders. By highlighting advances in usability, we aim to encourage thoughtful and rigorous design at the academic prototyping stage to address one outstanding hurdle that limits the number of PADs that make it from the benchtop to the point-of-care.


Assuntos
Técnicas Analíticas Microfluídicas , Sistemas Automatizados de Assistência Junto ao Leito , Bioensaio , Papel , Testes Imediatos
4.
Anal Chem ; 92(24): 16245-16252, 2020 12 15.
Artigo em Inglês | MEDLINE | ID: mdl-33227204

RESUMO

Lateral flow tests and hand-held analyzers facilitate diagnostic testing in resource limited settings and at the point-of-care. However, many of these devices require sample preparation such as plasma separation to remove cells and isolate the liquid portion of blood. Specifically, the separation of plasma from blood is necessary for routine health assessments such as comprehensive metabolic panels and chronic HIV viral load monitoring. Away from laboratories, this type of processing has been addressed by unconventional, hand-operated centrifuge devices (high volume) or plasma separation membranes (PSM) coupled with lateral flow tests (low volume). Herein, we describe a device that separates and stores plasma from undiluted blood using only passive filtration in less than 10 min. Integrating a PSM with a prefilter and absorbent material yields a 3-fold increase in separation efficiency compared to similar devices using passive filtration. We demonstrate the reproducibility of our device across the physiological range of hematocrits (20-50%) with an average recovered plasma volume of 61.7 ± 2.6 µL. Maximum separation efficiency (53.8%, 65.6 ± 3.9 µL plasma) was achieved for a sample of whole blood (30% hematocrit) in 10 min. We evaluate the purity of our plasma sample by quantitation of hemoglobin and report hemolysis as either minimal (≤5%) or undetectable (≤1%). Specific recovery of human IgG, IFN-γ, and HIV-1 RNA indicate the diagnostic utility of plasma obtained from our device is unchanged compared to plasma obtained via centrifugation. Finally, we demonstrate the use of recovered plasma, applied via "stamping", to successfully conduct a commercial lateral flow immunochromatographic assay for tetanus antibodies. This device platform is capable of producing pure plasma samples from blood to facilitate tests in resource limited settings to improve access to healthcare.


Assuntos
Sangue , Separação Celular/métodos , Filtração/métodos , Plasma/citologia , Hematócrito , Humanos
5.
Anal Biochem ; 543: 116-121, 2018 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-29224732

RESUMO

This paper demonstrates a new method for electrochemical detection of specific sequences of DNA present in trace amounts in serum or blood. This method is designed for use at the point-of-care (particularly in resource-limited settings). By combining recombinase polymerase amplification (RPA)- an isothermal alternative to the polymerase chain reaction - with an electroactive mediator, this electrochemical methodology enables accurate detection of DNA in the field using a low-cost, portable electrochemical analyzer (specifically designed for this type of analysis). This handheld device has four attributes: (1) It uses disposable, paper-based strips that incorporate screen-printed carbon electrodes; (2) It accomplishes thermoregulation with ±0.1 °C temperature accuracy; (3) It enables electrochemical detection using a variety of pulse sequences, including square-wave and cyclic voltammetry, and coulometry; (4) It is operationally simple to use. Detection of genomic DNA from Mycobacterium smegmatis (a surrogate for M. tuberculosis-the main cause of tuberculosis), and from M. tuberculosis itself down to ∼0.040 ng/µL provides a proof-of-concept for the applicability of this method of screening for disease using molecular diagnostics. With minor modifications to the reagents, this method will also enable field monitoring of food and water quality.


Assuntos
DNA Bacteriano/genética , Técnicas Eletroquímicas , Técnicas de Amplificação de Ácido Nucleico , Carbono/química , Mycobacterium smegmatis/genética , Mycobacterium tuberculosis/genética , Temperatura , Tuberculose/diagnóstico , Tuberculose/genética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...