1.
Ann Thorac Surg ; 102(3): e191-e192, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27549538

RESUMO

A 46-year-old man experienced a remote unexpected lung injury with a sharp object. The object migrated over the years, penetrating the mediastinal structure, injuring the pericardium and the right-sided chambers of the heart. The injury was complicated by hemodynamic instability and pericardial tamponade. An emergent pericardiocentesis followed by thoracotomy, foreign body extraction, and puncture site closure. This is a very rare case of remote penetrating lung injury with a dormant course.


Assuntos
Tamponamento Cardíaco/diagnóstico por imagem , Tamponamento Cardíaco/cirurgia , Migração de Corpo Estranho/diagnóstico por imagem , Migração de Corpo Estranho/cirurgia , Imageamento Tridimensional , Tamponamento Cardíaco/etiologia , Doença Crônica , Ecocardiografia/métodos , Corpos Estranhos/complicações , Corpos Estranhos/cirurgia , Vidro , Traumatismos Cardíacos/etiologia , Traumatismos Cardíacos/fisiopatologia , Traumatismos Cardíacos/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Pericardiocentese/métodos , Doenças Raras , Medição de Risco , Toracotomia/métodos , Fatores de Tempo , Resultado do Tratamento , Ferimentos Penetrantes/diagnóstico por imagem , Ferimentos Penetrantes/cirurgia