Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Arrhythm ; 40(3): 605-613, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38939791

RESUMO

Background: The Mt FUJI study was a multicenter, prospective, randomized, single-blind, controlled trial comparing delivery catheter-based and stylet-based right ventricular (RV) lead placement at the RV septum. This study extended the follow-up duration to 1 year after implantation. Methods: Seventy patients with pacemaker indications for atrioventricular block were randomly assigned to the delivery catheter and stylet groups. We compared the mid-term efficacy and safety between the two groups at 1 year after implantation. The primary outcome was the change in the left ventricular ejection fraction (LVEF), and the secondary outcomes were changes in brain natriuretic peptide (BNP) levels, lead parameters, paced QRS duration, and the incidence of adverse events. Results: At the 1-year follow-up, no significant differences were observed in the changes in the LVEF (+1.0% ± 8.6% vs. +3.1% ± 8.1%, p = .332), BNP levels (+8.0 [-11.1, 26.5] pg/mL vs. -8.7 [-15.3, 13.2] pg/mL, p = .193), or lead performance between the delivery catheter and stylet groups. The QRS duration was significantly shorter in the delivery catheter group than in the stylet group (128 ± 23 ms vs. 146 ± 17 ms, p < .001). All-cause death, hospitalization for heart failure, new development of atrial fibrillation, and pacing-induced cardiomyopathy occurred in seven patients in the delivery catheter group and five in the stylet group. Conclusion: The delivery catheter system was similarly useful and safe compared to the stylet system in the mid-term follow-up from the Mt FUJI trial. Further long-term evaluations are warranted.

2.
Front Cardiovasc Med ; 11: 1388686, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38867848

RESUMO

Background: The mortality rate of acute coronary syndrome (ACS) remains high. Therefore, patients with ACS should undergo early risk stratification, for which various risk calculation tools are available. However, it remains uncertain whether the predictive performance varies over time between risk calculation tools for different target periods. This study aimed to compare the predictive performance of risk calculation tools in estimating short- and long-term mortality risks in patients with ACS, while considering different observation periods using time-dependent receiver operating characteristic (ROC) analysis. Methods: This study included 404 consecutive patients with ACS who underwent coronary angiography at our hospital from March 2017 to January 2021. The ACTION and GRACE scores for short-term risk stratification purposes and CRUSADE scores for long-term risk stratification purposes were calculated for all participants. The participants were followed up for 36 months to assess mortality. Using time-dependent ROC analysis, we evaluated the area under the curve (AUC) of the ACTION, CRUSADE, and GRACE scores at 1, 6, 12, 24, and 36 months. Results: Sixty-six patients died during the observation periods. The AUCs at 1, 6, 12, 24, and 36 months of the ACTION score were 0.942, 0.925, 0.889, 0.856, and 0.832; those of the CRUSADE score were 0.881, 0.883, 0.862, 0.876, and 0.862; and those of the GRACE score 0.949, 0.928, 0.888, 0.875, and 0.860, respectively. Conclusions: The ACTION and GRACE scores were excellent risk stratification tools for mortality in the short term. The prognostic performance of each risk score was almost similar in the long term, but the CRUSADE score might be a superior risk stratification tool in the longer term than 3 years.

3.
Molecules ; 29(8)2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38675520

RESUMO

Trinuclear metallacyclic oxidovanadium(V) complexes, [{VO(L3+2R)}3] (1-3) with asymmetric multidentate linking ligands (H3L3+2R: R = H, Me, Br), were synthesized. The molecular structure of 1 is characterized as a tripod structure, with each V(V) ion coordinated by ONO-atoms from a tridentate Schiff base site and ON-atoms from a bidentate benzoxazole site of two respective H3L3+2H ligands. The intramolecular V⋯V distances range from 8.0683 to 8.1791 Å. Complex 4 is a mononuclear dioxidovanadium(V) complex, (Et3NH)[VO2(HL3+2H)]. Cyclic voltammograms of 1-3 in DMF revealed redox couples attributed to three single-electron transfer processes.

4.
J Cardiovasc Electrophysiol ; 35(4): 802-810, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38409896

RESUMO

INTRODUCTION: The Mt. FUJI multicenter trial demonstrated that a delivery catheter system had a higher rate of successful right ventricular (RV) lead deployment on the RV septum (RVS) than a conventional stylet system. In this subanalysis of the Mt. FUJI trial, we assessed the differences in electrocardiogram (ECG) parameters during RV pacing between a delivery catheter system and a stylet system and their associations with the lead tip positions. METHODS: Among 70 patients enrolled in the Mt FUJI trial, ECG parameters, RV lead tip positions, and lead depth inside the septum assessed by computed tomography were compared between the catheter group (n = 36) and stylet group (n = 34). RESULTS: The paced QRS duration (QRS-d), corrected paced QT (QTc), and JT interval (JTc) were significantly shorter in the catheter group than in the stylet group (QRS-d: 130 ± 19 vs. 142 ± 15 ms, p = .004; QTc: 476 ± 25 vs. 514 ± 20 ms, p < .001; JTc: 347 ± 24 vs. 372 ± 17 ms, p < .001). This superiority of the catheter group was maintained in a subgroup analysis of patients with an RV lead tip position at the septum. The lead depth inside the septum was greater in the catheter group than in the stylet group, and there was a significant negative correlation between the paced QRS-d and the lead depth. CONCLUSION: Using a delivery catheter system carries more physiological depolarization and repolarization during RVS pacing and deeper screw penetration in the septum in comparison to conventional stylet system. The lead depth could have a more impact on the ECG parameters rather than the type of pacing lead.


Assuntos
Estimulação Cardíaca Artificial , Septo Interventricular , Humanos , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/métodos , Catéteres , Eletrocardiografia/métodos , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Septo Interventricular/diagnóstico por imagem
5.
JACC Case Rep ; 28: 102123, 2023 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-38204538

RESUMO

An 89-year-old man with a history of percutaneous coronary intervention using a sirolimus-eluting stent presented with recurrent in-stent occlusion. Pathological assessment of the neointima resected via directional coronary atherectomy revealed a double-layered thrombus. Clopidogrel resistance and limited antithrombotic regimen owing to high bleeding risk likely resulted in the in-stent thrombotic occlusion.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA