1.
Cardiovasc Intervent Radiol ; 46(1): 100-111, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36450994

RESUMO

PURPOSE: To assess occlusion success and adverse events associated with the use of a self-expanding device for peripheral artery embolization. METHODS: This prospective, single-arm, feasibility study was conducted using the Caterpillar™ Arterial Embolization Device composed of opposing nitinol fibers and a flow-occluding membrane. Twenty patients (24 embolization sites) were treated at four investigational centers in New Zealand and Australia and followed for 30 days. Embolization sites included mesenteric, accessory renal, and iliac arteries and their branches. Primary outcome measures were peri-procedural occlusion confirmed by angiography and freedom from device-related serious adverse events (SAEs) at 30 days. Secondary observations included time to occlusion and assessment of adverse events. RESULTS: Peri-procedural occlusion was 100%, and freedom from a device-related SAE was 94.7% at 30 days. One patient had abdominal bloating that required hospitalization deemed possibly related to the device or procedure. Twenty-two of 24 embolization sites were occluded with one device (91.7%). Mean procedure duration was 11.7 ± 8.6 min (device deployment time: 1.8 ± 1.0 min), and mean fluoroscopy time was 241 ± 290.7 s. All embolization sites occluded during the procedure with 62.5% occluded within three minutes and 91.6% occluded within ten minutes. No devices migrated or required re-embolization. Freedom from device- and procedure-related adverse events was 84.2%. One patient died from aortic rupture during a subsequent adjunctive abdominal aortic endovascular procedure deemed unrelated to the embolization device or procedure. CONCLUSIONS: This first-in-human study of the Caterpillar embolization device achieved peri-procedural occlusion in all patients with a 94.7% freedom from device-related SAE at 30 days. LEVEL OF EVIDENCE: Level 2b-prospective, multicenter, single-arm, first-in-human clinical study. Pre-specified endpoints were analyzed using descriptive statistics.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Embolização Terapêutica , Procedimentos Endovasculares , Humanos , Prótese Vascular , Stents , Estudos Prospectivos , Resultado do Tratamento , Implante de Prótese Vascular/efeitos adversos , Aneurisma da Aorta Abdominal/cirurgia
3.
Cardiovasc Intervent Radiol ; 44(12): 1918-1929, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34545448

RESUMO

PURPOSE: To assess safety and patency of the Venovo venous stent for the treatment of iliofemoral vein obstruction. MATERIALS AND METHODS: Twenty-two international centers enrolled 170 patients in the VERNACULAR study (93 post-thrombotic syndrome; 77 non-thrombotic iliac vein lesions). Primary outcome measures were major adverse events at 30 days and 12-month primary patency (freedom from target vessel revascularization, thrombotic occlusion, or stenosis > 50%). Secondary outcomes included the Venous Clinical Severity Score Pain Assessment and Chronic Venous Quality-of-Life Questionnaire assessments (hypothesis tested). Secondary observations included primary patency, target vessel and lesion revascularization (TVR/TLR), and assessment of stent integrity through 36 months. RESULTS: Freedom from major adverse events through 30 days was 93.5%, statistically higher than a pre-specified performance goal of 89% (p = 0.032) while primary patency at 12 months was 88.6%, also statistically higher than a performance goal of 74% (p < 0.0001). Mean quality-of-life measures were statistically improved compared to baseline values at 12 months (p < 0.0001). Primary patency at 36 months was 84% (Kaplan-Meier analysis) while freedom from TVR/TLR was 88.1%. There was no stent embolization/migration, and no core laboratory assessed stent fractures reported through 36 months. Six deaths were reported; none adjudicated as device or procedure related. CONCLUSION: The Venovo venous stent was successfully deployed in obstructive iliofemoral vein lesions and met the pre-specified primary outcome measures through 12 months. At 3 years, primary patency was 84%, reintervention rates were low, standardized quality-of-life and pain measures improved from baseline, and there was no stent migration or fractures. LEVEL OF EVIDENCE: Level 2-prospective, multicenter, controlled clinical study without a concurrent control or randomization. Pre-specified endpoints were hypothesis-tested to performance goals derived from peer-reviewed clinical literature. REGISTRATION CLINICALTRIALS.GOV: Unique Identifier NCT02655887.


Assuntos
Veia Femoral , Veia Ilíaca , Veia Femoral/diagnóstico por imagem , Veia Femoral/cirurgia , Humanos , Veia Ilíaca/diagnóstico por imagem , Veia Ilíaca/cirurgia , Estudos Prospectivos , Estudos Retrospectivos , Stents , Resultado do Tratamento , Grau de Desobstrução Vascular
4.
J Clin Hypertens (Greenwich) ; 23(7): 1380-1389, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-34137162

RESUMO

Homocysteine is an independent risk factor for cardiovascular and cerebrovascular disease and has been proposed to contribute to vascular dysfunction. We sought to determine in a real-world clinical setting whether homocysteine levels were associated with hypertension mediated organ damage (HMOD) and could guide treatment choices in hypertension. We performed a cross-sectional analysis of prospectively collected data in 145 hypertensive patients referred to our tertiary hypertension clinic at Royal Perth Hospital and analyzed the association of homocysteine with HMOD, renin-angiotensin-aldosterone system (RAAS), and RAAS blockade. The average age of participants was 56 ± 17 years, and there was a greater proportion of males than females (89 vs. 56). Regression analysis showed that homocysteine was significantly associated with PWV (ß = 1.99; 95% CI 0.99-3.0; p < .001), albumin-creatinine ratio (lnACR: ß = 1.14; 95% CI 0.47, 1.8; p < .001), 24 h urinary protein excretion (ß = 0.7; 95% CI 0.48, 0.92; p < .001), and estimated glomerular filtration rate (ß = -29.4; 95% CI -36.35, -22.4; p < .001), which persisted after adjusting for potential confounders such as age, sex, 24 h BP, inflammation, smoking, diabetes mellitus (DM), and dyslipidemia. A positive predictive relationship was observed between plasma homocysteine levels and PWV, with every 1.0 µmol/L increase in homocysteine associated with a 0.1 m/s increase in PWV. Homocysteine was significantly associated with elevated aldosterone concentration (ß = 0.26; p < .001), and with attenuation of ACEi mediated systolic BP lowering and regression of HMOD compared to angiotensin receptor blockers in higher physiological ranges of homocysteine. Our results indicate that homocysteine is associated with hypertension mediated vascular damage and could potentially serve to guide first-line antihypertensive therapy.


Assuntos
Anti-Hipertensivos , Hipertensão , Adulto , Idoso , Anti-Hipertensivos/uso terapêutico , Pressão Sanguínea , Estudos Transversais , Feminino , Homocisteína , Humanos , Masculino , Pessoa de Meia-Idade
5.
Ann Vasc Surg ; 76: 222-231, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34182115

RESUMO

BACKGROUND: The utilisation rate of endovascular aortic aneurysm repair has increased continuously over the past 2 decades. Endovascular aortic aneurysm repair is still performed frequently in patients with an unfavourable proximal seal zone, despite the associated late complications. PURPOSE: We aimed to evaluate the mid-term durability of the GORE® EXCLUDER® AAA Endoprosthesis, featuring the C3 delivery system, in patients with a proximal neck anatomy outside the instructions for use (IFU). METHODS: A retrospective sub-analysis of the Global Registry for Endovascular Aortic Treatment including patients treated for abdominal aortic aneurysms with the GORE EXCLUDER AAA Endoprosthesis (W.L. Gore & Associates, Inc, Flagstaff, Arizona) was performed. A "challenging neck" was defined as those treated outside the IFU with an aortic neck length <15 mm and/or aortic neck angle >60°. Cox proportional analyses were used to test for time-to-event differences between those treated within and outside the IFU while accounting for covariates, specifically proximal neck length and neck angle. The main outcomes assessed were 5-year all-cause mortality, 5-year endoleak development (type I or III), and 5-year device-related reinterventions. FINDINGS: Of the 3,324 patients included in the analysis, 411 (12.4%) had a challenging neck and 2,913 (87.6%) did not. The patients in the challenging neck group were significantly older (74.9 years vs. 73.2 years, p≤0.0001) and had a significantly larger aortic aneurysm diameter at the time of the intervention than those treated within the IFU (61.2 mm vs. 56.4 mm, P< 0.0001), shorter proximal neck length (18 mm vs. 30 mm, P< 0.0001) and larger infrarenal neck angle (60.8° vs. 25.8°, P< 0.0001). In the multivariate analysis, brachial access site and challenging neck were not independent risk factors; increased age was associated with a shorter time to mortality (hazard ratio 1.051, 95% confidence interval 1.039-1.062, P< 0.0001), as was the use of tobacco (hazard ratio 1.329, 95% confidence interval 1.124-1.571, P= 0.0009). The 5-year all-cause mortality (36.2% vs. 27.5%, P= 0.002) and aorta-related mortality (3.8% vs. 1.1%, P= 0.002) were significantly higher in the challenging neck group. The risk of death within 5 years also increased significantly at 1.1% per millimetre increase in the abdominal aortic aneurysm diameter (P= 0.0005). Furthermore, the rates of type Ia endoleak development (7% vs. 1.2%, P< 0.001) and requirement for reintervention (13.3% vs. 9.7%, P< 0.001) were higher in those treated outside the IFU (challenging neck group). CONCLUSIONS: Treatment with the Excluder AAA Endograft outside the IFU was associated with higher 5-year mortality values, increased type Ia endoleak development rates, and a greater need for reintervention compared with treatment within the IFU. This reiterates that fenestrated and open treatments should be strongly considered in cases with aortic neck anatomies outside the IFU. Infrarenal endovascular intervention outside the IFU should only be used when there is no alternative, with meticulous procedural planning and intervention to promote satisfactory outcomes.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Stents , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Masculino , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/terapia , Sistema de Registros , Retratamento , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
6.
Cureus ; 13(5): e14841, 2021 May 04.
Artigo em Inglês | MEDLINE | ID: mdl-33959465

RESUMO

Background Endovascular aneurysm repair (EVAR) has become the treatment modality of choice in patients with abdominal aortic aneurysms. This has resulted in endograft utilization within instructions for use (IFU) and in cases with proximal neck anatomy outside of IFU. Purpose To identify whether graft selection influences outcomes following EVAR outside of IFU. Methodology A retrospective analysis was conducted from previously published data for 636 patients, collated from the Endurant Stent Graft Natural Selection Global Post-Market Registry (ENGAGE) and the Global Registry for Endovascular Aortic Treatment (GREAT). Patients were recruited into the ENGAGE registry between 2009 and 2011 and into the GREAT registry between August 2010 and October 2016. In ENGAGE, they received the Medtronic Endurant stent graft (Medtronic Vascular Inc, Dublin, Ireland) for infrarenal AAA repair while patients analyzed in GREAT received the Gore Excluder stent-graft (W. L. Gore & Associates, Flagstaff, Arizona). Analyses were performed to evaluate all-cause mortality, aneurysm-related mortality, endoleak occurrence, and surgical reintervention rates between the two cohorts. Results Of the 636 patients, 225 were from ENGAGE (mean age 73 years) and 411 were from GREAT (mean age 75 years). 17.8% were treated outside of IFU in the ENGAGE registry, while 12.4% were treated outside IFU in the GREAT cohort. Five-year freedom from all-cause mortality was similar in both cohorts (65.6% vs. 63.8%). The rate of type IA endoleak development was lower in the Excluder cohort, although this may have been impacted by the fact that only endoleaks that underwent reintervention were recorded within GREAT analysis (Endurant 10.6% vs. Excluder 7.0%). The reintervention rate was 16% at five years following the Endurant aortic graft while it was 13.3% at five years with the Excluder. Conclusion Treatment outside of IFU, be it with a suprarenal or an infrarenal fixation device, is associated with worse outcomes. This analysis reinforces the importance of the consideration of either fenestrated or open repair in those aneurysms that fail to satisfy IFU while endovascular repair in such a setting should be reserved as a last resort strategy.

7.
Cureus ; 13(4): e14584, 2021 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-33889469

RESUMO

Background Abdominal aortic aneurysms (AAA) are far more common in male than female gender, although they appear to have a more aggressive pathophysiology in females. Given the lower incidence of AAA in females, it has been difficult to assess the impact of graft selection for endovascular aortic aneurysm repair (EVAR) in this cohort. Purpose To identify whether graft selection influences outcomes following AAA endoluminal repair in female patients. Methodology A retrospective analysis of published data for 711 female patients was conducted, collating data from three cohorts - Endurant Stent Graft Natural Selection Global post-market registry (ENGAGE), Global Registry for Endovascular Aortic Treatment (GREAT) and U.S. Zenith multicenter trial in combination with the Zenith female registry. Patients were recruited into the ENGAGE registry between 2009 and 2011, the GREAT registry between August 2010 and October 2016, and into the Zenith registry between 2000 and 2003. Patients from ENGAGE received the Medtronic Endurant stent graft for infrarenal AAA repair, patients analysed in GREAT received the Gore Excluder stent graft and the Zenith group received the Cook Zenith stent graft. Analyses were performed to evaluate all-cause mortality, aorta-related mortality, endoleak occurrence and surgical reintervention rates between the three cohorts. Results Of the 711 females, 133 were from ENGAGE (mean age 76 years), 538 were from GREAT (mean age 75 years) and 40 were from Zenith (mean age 74 years). The rates of co-morbidities between the three groups were broadly similar except for atherosclerotic disease which was more commonly observed in those treated with the GORE Excluder. The rate of endoleaks was lower when the Excluder stent was utilised as compared to the other two stents (Excluder 6.7% vs. Zenith 12.5% vs. Endurant 35.3%) even considering the limited follow-up of the Zenith group to two years as compared to five years for both ENGAGE and GREAT. All-cause mortality was similar in all three groups across the period examined while aorta-related mortality was uncommon. Reintervention rate was 15% at two years following the utilisation of the Zenith aortic graft while the rate of intervention at five years was broadly similar between ENGAGE and GREAT. Conclusion The newer generation, lower profile aortic endografts appear to have provided a safe and successful tool in the management of AAA in female patients, despite more complex aortic anatomy with shorter infrarenal neck length and larger aortic neck angulation.

9.
J Vasc Surg ; 73(1): 69-80, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32442605

RESUMO

OBJECTIVE: We aimed to assess the 5-year safety and effectiveness outcomes of patients enrolled in the Endurant Stent Graft Natural Selection Global Post Market Registry (ENGAGE) who were treated outside the approved indications for use (IFU) of the Endurant stent graft. METHODS: Our primary outcome measure was 12-month treatment success, defined as successful endograft delivery and deployment and the absence of type I or III endoleak, stent migration or limb occlusion, late conversion, and abdominal aortic aneurysm diameter increase or rupture. Secondary outcome measures included 30-day all-cause mortality, major adverse events, secondary procedures, technical observations, aneurysm-related mortality, and all-cause mortality within 12 months. RESULTS: Demographic characteristics of ENGAGE patients treated outside (225 [17.8%]) and within (1038 [82.2%]) the IFUs were similar, except that female patients comprised a much higher percentage of the outside IFU group (19.1% vs 8.7%; P < .001). The outside IFU group presented with lower rates of coronary artery disease and cardiac revascularization and a greater number of symptomatic patients compared with the within IFU group (21.3% vs 15.0%; P = .020). Technical success was achieved in more than 99% of all patients. The outside and within IFU groups showed a comparable and low occurrence of uncorrected type I (0.9% vs 1.2%; P = 1.00) and type III endoleak (0.4% vs 0.3%; P = .54) immediately after device implantation. The 5-year freedom from type IA endoleaks was 89.4% vs 96.7% (P < .0001) for those patients outside and within the IFUs, respectively, although both groups had similar type III endoleaks through 5 years (P = .61). Stent graft limb occlusion estimated overall survival, and freedom from aneurysm-related mortality and endovascular interventions were comparable in both patient groups through the 5-year follow-up. The Kaplan-Meier estimates at 5 years showed a trend for low but increased need for type I or III endoleak correction procedures in the outside IFU group compared with the within IFU group (7.2% vs 5.2%; P = .099). CONCLUSIONS: Differences were not observed in all-cause mortality, aneurysm-related mortality, and secondary procedures between within and outside IFU patients through a 5-year follow-up in the ENGAGE registry. Proximal necks with angulation or diameters outside the IFUs were the most common reasons for patients identified as being outside IFU, and the cohort had increased incidence of type IA endoleaks. Despite the challenges presented from the broad range of aortic and abdominal aortic aneurysm morphologies, the Endurant stent graft showed promising 5-year outcomes.


Assuntos
Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Prótese Vascular , Procedimentos Endovasculares/métodos , Stents , Idoso , Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/diagnóstico , Aneurisma da Aorta Abdominal/mortalidade , Aortografia/métodos , Causas de Morte/tendências , Europa (Continente)/epidemiologia , Feminino , Seguimentos , Humanos , Masculino , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Taxa de Sobrevida/tendências , Fatores de Tempo , Resultado do Tratamento
10.
Cardiovasc Intervent Radiol ; 44(5): 689-697, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33367944

RESUMO

PURPOSE: Ambulatory peripheral vascular interventions have been steadily increasing. In ambulatory procedures, 4F devices might be particularly useful having the potential to reduce access-site complications; however, further evidence on their safety and efficacy is needed. MATERIALS AND METHODS: BIO4AMB is a prospective, non-randomized mulitcentre, non-inferiority trial conducted in 35 centres in Europe and Australia comparing the use of 4F- and 6F-compatible devices. The main exclusion criteria included an American Society of Anaesthesiologists class ≥ 4, coagulation disorders, or social isolation. The primary endpoint was access-site complications within 30 days. RESULTS: The 4F group enrolled 390 patients and the 6F group 404 patients. Baseline characteristics were similar between the groups. Vascular closure devices were used in 7.7% (4F group) and 87.6% (6F group) of patients. Patients with vascular closure device use in the 4F group were subsequently excluded from the primary analysis, resulting in 361 patients in the 4F group. Time to haemostasis was longer for the 4F group, but the total procedure time was shorter (13.2 ± 18.8 vs. 6.4 ± 8.9 min, p < 0.0001, and 39.1 ± 25.2 vs. 46.4 ± 27.6 min, p < 0.0001). Discharge on the day of the procedure was possible in 95.0% (4F group) and 94.6% (6F group) of patients. Access-site complications were similar between the groups (2.8% and 3.2%) and included predominantly groin haematomas and pseudoaneurysms. Major adverse events through 30 days occurred in 1.7% and 2.0%, respectively. CONCLUSIONS: Ambulatory peripheral vascular interventions are feasible and safe. The use of 4F devices resulted in similar outcomes compared to that of 6F devices.


Assuntos
Procedimentos Endovasculares/instrumentação , Artéria Femoral/cirurgia , Técnicas Hemostáticas/instrumentação , Dispositivos de Oclusão Vascular , Idoso , Desenho de Equipamento , Feminino , Humanos , Masculino , Estudos Prospectivos , Resultado do Tratamento
11.
Eur J Vasc Endovasc Surg ; 60(4): 519-530, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32624387

RESUMO

OBJECTIVE: Hospital and surgeon operative caseload is thought to be associated with peri-operative mortality following the non-elective repair of aortic aneurysms; however, whether such an association exists within the Australian healthcare setting is unknown. METHODS: The Australasian Vascular Audit was interrogated to identify patients undergoing non-elective (emergency [EMG] or semi-urgent [URG]) aortic aneurysm repair between 2010 and 2016, as well as their treating surgeon and hospital. Hierarchal logistic regression modelling was used to assess the impact of caseload on outcomes after both endovascular (EVAR) and open surgical repair (OSR). RESULTS: Volume counts were determined from 14 262 patients (4 121 OSR and 10 141 EVAR). After exclusion of elective procedures and duplicates, 1 153 EVAR (570 EMG and 583 URG) and 1 245 OSR (946 EMG and 299 URG) non-elective cases remained for the analysis. Crude mortality was 24.0% following OSR (EMG 29.2%; URG 7.7%) and 7.5% following EVAR (EMG 12.6%; URG 2.4%). Univariable analysis demonstrated an association between OSR mortality and hospital volume (quintile [Q] 1: 25.3%, Q2: 27.8%, Q3: 23.9%, Q4: 27.0%, Q5: 16.2%; p = .030), but not surgeon (Q1: 25.2%, Q2: 27.4%, Q3: 26.0%, Q4: 21.4%, Q5: 19.5%, p = .32). Multivariable analysis confirmed this association (odds ratio (OR) [95% CI]; Q1 vs 5: 1.91 [1.13-3.21], Q2 vs. 5: 2.01[1.24-3.25], Q3 vs. 5: 1.41 [0.86-2.29], Q4 vs. 5: 1.92 [1.17-3.15]; p = .020). The difference was most pronounced in the EMG OSR group [Q1 - 3 vs. 4-5] (OR 1.63 [1.07-2.48]; p = .020). Mortality after EVAR was not associated with either hospital (Q1: 6.3%, Q2: 10%, Q3: 6.8%, Q4: 4.5%, Q5: 10%; p = .14) or surgeon volume (Q1: 9.3%, Q2: 5.7%, Q3: 8.1%, Q4: 7.0%, Q5: 7.3%; p = .67). CONCLUSION: There is an inverse correlation between hospital volume and peri-operative mortality following EMG open repair of aortic aneurysm. These data support restructuring Australian pathways of care to direct suspected ruptured aneurysm to institutions that reach a minimum volume threshold.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Ruptura Aórtica/cirurgia , Procedimentos Endovasculares , Hospitais com Alto Volume de Atendimentos , Hospitais com Baixo Volume de Atendimentos , Avaliação de Processos e Resultados em Cuidados de Saúde , Cirurgiões , Procedimentos Cirúrgicos Vasculares , Carga de Trabalho , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Ruptura Aórtica/diagnóstico por imagem , Ruptura Aórtica/mortalidade , Austrália/epidemiologia , Competência Clínica , Bases de Dados Factuais , Emergências , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Mortalidade Hospitalar , Humanos , Masculino , Auditoria Médica , Pessoa de Meia-Idade , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/terapia , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Procedimentos Cirúrgicos Vasculares/efeitos adversos , Procedimentos Cirúrgicos Vasculares/mortalidade
12.
J Endovasc Ther ; 27(5): 836-844, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32436808

RESUMO

PURPOSE: To assess periprocedural results and secondary endovascular procedure outcomes over 5 years in patients aged ≥80 vs <80 years undergoing endovascular aneurysm repair (EVAR). MATERIALS AND METHODS: Data from the Endurant Stent Graft Natural Selection Global post-market registry (ENGAGE) were used for the analyses. A total of 1263 consecutive patients were enrolled in the prospective, observational, single-arm registry and divided into 2 groups according to age: ≥80 years (290, 22.9%) and <80 years (973, 77.1%). Baseline patient characteristics, risk scores according to the Society for Vascular Surgery (SVS) reporting standards, American Society of Anesthesiologists (ASA) classification, quality of life assessments [EuroQol 5 (EQ5D) index], and treatment outcomes, including all-cause mortality, aneurysm-related mortality, major adverse events, secondary endovascular procedures, and endoleaks were compared between groups. RESULTS: Octogenarians were classified into the highest category of the SVS risk stratification system; however, this did not result in a significant difference in the 30-day mortality [1.4% (4/290) vs 1.2% (12/973) for controls; p=0.85] or major adverse event rates [5.2% (15/290) vs 3.6% (35/973), p=0.23]. Multivariable analysis confirmed that age ≥80 years, pulmonary disease, large aneurysm diameter, and renal insufficiency were significantly associated with all-cause mortality, whereas diameter was the only parameter associated with increased aneurysm-related mortality. The differences in freedom from secondary endovascular procedures over 5 years between octogenarians and controls did not reach statistical significance (88.5% vs 83.2%, p=0.07). CONCLUSION: EVAR can be performed in individuals aged ≥80 years with no statistically significant difference in midterm aneurysm-related deaths compared with younger patients. The findings in this elderly patient cohort show that EVAR can be safely performed with acceptable morbidity rates in octogenarians.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Aneurisma da Aorta Abdominal/fisiopatologia , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Vigilância de Produtos Comercializados , Estudos Prospectivos , Sistema de Registros , Fatores de Risco , Stents , Fatores de Tempo , Resultado do Tratamento
13.
Surg Res Pract ; 2020: 8970759, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32232118

RESUMO

BACKGROUND: Several studies have reported worse outcomes in women compared to men after endovascular aneurysm repair (EVAR). This study aimed to evaluate sex-specific short-term and 5-year outcomes after EVAR. METHODS: A total of 409 consecutive patients underwent elective EVAR from 2004 to 2017 at two tertiary hospitals in Western Australia. Baseline, intraoperative, and postoperative variables were examined retrospectively according to sex. The primary outcome was 30-day mortality (death within 30 days after EVAR). Secondary outcomes were 30-day composite endpoint, length of stay after EVAR, 5-year survival, freedom from reintervention, residual aneurysm size after EVAR, and major adverse event rate at 5-year follow-up. RESULTS: A cohort of 409 patients, comprising 57 women (14%) and 352 men (86%), was analysed. Female patients were older (median age, 76.8 versus 73.5 years, p=0.017). Male patients were more likely to be past smokers (40.9% versus 22.8%, p=0.017). Male patients were more likely to be past smokers (40.9% versus 22.8%, p=0.017). Male patients were more likely to be past smokers (40.9% versus 22.8%, p=0.017). Male patients were more likely to be past smokers (40.9% versus 22.8%, p=0.017). Male patients were more likely to be past smokers (40.9% versus 22.8%, p=0.017). Male patients were more likely to be past smokers (40.9% versus 22.8%, p=0.017). Male patients were more likely to be past smokers (40.9% versus 22.8%. CONCLUSION: This study found no significant differences in 30-day and 5-year outcomes between female and male patients treated with EVAR, implying that EVAR remains a safe treatment choice for female patients.

14.
Ann Vasc Surg ; 67: 242-253.e4, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32194136

RESUMO

BACKGROUND: Abdominal aortic aneurysms (AAAs) are more common in men. However, women have been shown to have more short- and long-term adverse outcomes after endovascular aneurysm repair. This disparity is thought to be multifactorial, including anatomical differences, hormonal differences, older age of presentation, and a greater degree of preoperative comorbidities. METHODS: A retrospective analysis that included data for 3,758 patients from the Global Registry for Endovascular Aortic Treatment (GREAT) was conducted. Patients were recruited into GREAT between August 2010 and October 2016 and received the Gore Excluder stent graft for infrarenal AAAs repair. Cox multivariate regression analyses were performed to analyze any reintervention and device-related intervention rates. RESULTS: Of the 3,758 patients, 3,220 were male (mean age 73 years) and 538 were female (mean age 75 years). Women had higher prevalence rates of chronic obstructive pulmonary disease (P < 0.0001) and renal insufficiency (P = 0.03), whereas men had higher rates of cardiovascular comorbidities. The AAAs in women were smaller in diameter with shorter and more angulated necks. Women did not experience a significantly higher rate of endoleaks but did exhibit higher reintervention rates, including reintervention for device-related issues. In terms of mortality, aorta-related mortality was most prevalent within the first 30 days after procedure in both sexes. CONCLUSIONS: Women were treated at an older age and had a more hostile aneurysmal anatomy. Although the mortality rates were lower in women, they had significantly higher rates of reintervention, and thus higher morbidity rates after endovascular aneurysm repair.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Disparidades nos Níveis de Saúde , Disparidades em Assistência à Saúde , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Comorbidade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Masculino , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/terapia , Prevalência , Desenho de Prótese , Sistema de Registros , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores Sexuais , Stents , Fatores de Tempo , Resultado do Tratamento
15.
EJVES Short Rep ; 45: 34-37, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31872087

RESUMO

INTRODUCTION: The management of peri-aortitis, a rare complication after endovascular aneurysm repair (EVAR) of abdominal aortic aneurysms (AAA), is described in a patient with a solitary kidney. REPORT: A 64 year old man who developed peri-aortitis after elective EVAR for a 6.6 cm infrarenal AAA is reported. Peri-aortitis was diagnosed two months after the procedure and was successfully treated with corticosteroids. CONCLUSION: There is no clear consensus on the best medical therapy for peri-aortitis secondary to EVAR. Peri-aortitis must be considered in patients with ongoing systemic symptoms of inflammation after EVAR, and early management is crucial to the early resolution of symptoms.

16.
J Endovasc Ther ; 26(6): 759-767, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31431153

RESUMO

Purpose: To assess the incidence and predictors of severe, persistent postprocedural hypotension (PPH) after carotid artery stenting (CAS). Materials and Methods: A total of 146 patients (mean age 72.8 years; 104 men) who underwent 160 CAS procedures using a standardized protocol at 3 vascular centers were retrospectively analyzed. The primary endpoint was postprocedural hypotension, defined as a reduction in systolic blood pressure (SBP) >40 mm Hg from baseline or an SBP of <90 mm Hg sustained for >1 hour after CAS. Potential prognostic factors for postprocedural hypotension were identified and subjected to logistic regression analyses; outcomes are presented as the odds ratios (ORs) with 95% confidence intervals (CIs). Results: PPH developed in 36 (24.7%) patients after 37 (23.1%) CAS procedures. These patients had significantly longer intensive care unit and hospital stays than those who did not develop hypotension (p<0.001). PPH was associated with severe lesion calcification (OR 6.28, 95% CI 1.81 to 21.98, p=0.004) and contrast volume (OR 1.02, 95% CI 1.01 to 1.02, p<0.001). A 4-fold increase in the risk of PPH (OR 4.22, 95% CI 1.38 to 13.33, p=0.012) was found between the embolic protection device most associated with PPH (Angioguard) and the device least associated with PPH (Emboshield NAV6). A similar trend was also observed for the Precise vs Xact stents (OR 6, 95% CI 2.08 to 17.6, p=0.001). Bootstrapped multivariable modeling identified the Precise stent and contrast volume as significant predictors of persistent postprocedural hypotension. Further investigation of the contrast volume revealed associations with sex, severe calcification, arch type, previous coronary artery bypass surgery, and primary stenting, suggesting that the contrast volume reflects the complexity of the procedure. Conclusion: The complexity of the procedure and type of stent may play a role in the development of postprocedural hypotension after CAS.


Assuntos
Pressão Sanguínea , Doenças das Artérias Carótidas/terapia , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Hipotensão/epidemiologia , Stents , Idoso , Idoso de 80 Anos ou mais , Doenças das Artérias Carótidas/diagnóstico , Doenças das Artérias Carótidas/epidemiologia , Doenças das Artérias Carótidas/fisiopatologia , Feminino , Humanos , Hipotensão/diagnóstico , Hipotensão/fisiopatologia , Incidência , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento
17.
Case Rep Vasc Med ; 2019: 6853135, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31093417

RESUMO

Infrarenal abdominal aortic dissections (IAAD) are exceedingly rare, accounting for 1-4% of all aortic dissections. The evidence is scarce on how to best manage IAAD when they become symptomatic. Two main interventional approaches exist, open surgery and the endovascular approach. Conventional stent-graft systems make it difficult to treat nonaneurysmal aortic disease due to limb competition in a narrow distal aorta. Thus, we present a novel use of the Endologix Anatomical Fixation 2 (AFX2) Abdominal Aortic Aneurysm (AAA) endograft system for the treatment of four patients with IAAD. We also highlight an individual case study that was treated with an alternative endovascular approach and the complications that followed. This was to highlight and compare our successful experience with Endologix AFX2 AAA endograft system. There were multiple benefits for choosing this stent-graft; however the main advantage is its suitability in the narrow distal aorta. Our aim was to highlight an alternative endovascular approach for the successful treatment of a rare, challenging, and potentially fatal pathology.

19.
Eur J Vasc Endovasc Surg ; 57(4): 510-519, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30528451

RESUMO

OBJECTIVES: Operative caseload is thought to be associated with peri-operative mortality following intact aortic aneurysm repair. The aim was to study that association in the Australian setting, which has a unique healthcare provision system and geographical population distribution. METHODS: The Australasian Vascular Audit database was used to capture volume measurements for both individual surgeon and hospital and to separate it into quintiles (1, lowest, to 5, highest) for endovascular (EVAR), open surgical repair (OSR), and subgroups of repair types between 2010 and 2016. Multivariable logistic regression modelling was used to assess the impact of caseload volumes on in hospital mortality after adjustment for confounders. RESULTS: Volume counts were determined from 14,262 aneurysm repair procedures (4121 OSR, 10,106 EVAR). After exclusions, 2181 OSR (161 complex, 2020 standard) and 7547 EVAR (6198 standard, 1135 complex, 214 thoracic (TEVAR)) elective cases were available for volume analysis. Unadjusted mortality after EVAR was unaffected by either surgeon (Quintile 1, 1.0%; Quintile 5, 0.9%; p = .28) or hospital volume (Quintile 1, 0.8%; Quintile 5, 1.3%; p = .47). However, univariable analysis of the TEVAR subgroup revealed a significant correlation with hospital volume (Quintiles 1-2 vs. Quintiles 3-5; p = .02). Univariable analysis for OSR demonstrated a marginal, non-significant value for surgeon (Quintile 1, 4.0%; Quintile 5, 3.6%; p = .06), but not hospital volume (Quintile 1, 4.7%; Quintile 5, 4.0%; p = .67). After adjustment for confounders hospital volume remained a significant predictor of peri-operative TEVAR mortality (Quintile 1-2 vs. 3-5; OR 5.62, 95% CI 1.27-24.83; p = .02) and surgeon volume a predictor following standard OSR (Quintile 1-2 vs. Quintile 3-5; OR 2.15, 95% CI 1.21-3.83; p = .01). CONCLUSIONS: There is an inverse correlation between both surgeon volume of open aortic aneurysm repair, hospital volume of thoracic endovascular aneurysm repair and in hospital mortality. These findings suggest that in Australia TEVAR should be performed by high volume hospitals and OSR by high volume surgeons.


Assuntos
Aneurisma Aórtico/cirurgia , Implante de Prótese Vascular/efeitos adversos , Mortalidade Hospitalar , Auditoria Médica/estatística & dados numéricos , Avaliação de Processos e Resultados em Cuidados de Saúde/estatística & dados numéricos , Adulto , Idoso , Idoso de 80 Anos ou mais , Aneurisma Aórtico/mortalidade , Austrália/epidemiologia , Implante de Prótese Vascular/estatística & dados numéricos , Bases de Dados Factuais/estatística & dados numéricos , Feminino , Hospitais com Alto Volume de Atendimentos/estatística & dados numéricos , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Período Perioperatório/estatística & dados numéricos , Medição de Risco , Cirurgiões/estatística & dados numéricos , Resultado do Tratamento , Carga de Trabalho/estatística & dados numéricos
20.
EJVES Short Rep ; 37: 1-4, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29234730

RESUMO

BACKGROUND: Visceral arterial pseudoaneurysms (VAPAs) are rare vascular entities with serious consequences. Traditionally, they are associated with trauma, infection, and inflammatory disease, or they can arise as a post-operative complication. REPORT: An 87 year old man presented with abdominal pain and was found to have a spontaneous VAPA on a computed tomography angiogram. Serial imaging 4 months previously had demonstrated no aneurysm. Between scans, warfarin was changed to apixaban for aortic valve replacement, but he had no other changes to any other medications. He required urgent endovascular coiling of the pseudoaneurysm, with satisfactory recovery and outcome. DISCUSSION: VAPAs are extremely rare, with splenic artery VAPAs the most commonly reported. Regardless, fewer than 250 cases of splenic artery pseudoaneurysm have been reported. Superior mesenteric artery (SMA) pseudoaneurysms are the rarest type of VAPAs. Early identification and urgent treatment are warranted because of the associated high mortality risk, with a 50% risk of rupture in any given VAPA. Treatment options range from open operation to endoscopic and endovascular procedures. Apixaban has been proposed to contribute to pseudoaneurysm formation by slow and continuous bleeding that results in the formation of the pseudoaneurysm. CONCLUSIONS: Spontaneous VAPAs are extremely rare and this is the first time a VAPA has been associated with the novel oral anticoagulant "apixaban". Urgent management of any VAPAs is important because of the high risk of rupture and potential life threatening haemorrhage.