Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
1.
Med Phys ; 47(8): 3344-3355, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32406534

RESUMO

PURPOSE: Although several metal artifact reduction (MAR) algorithms for computed tomography (CT) scanning are commercially available, no quantitative, rigorous, and reproducible method exists for assessing their performance. The lack of assessment methods poses a challenge to regulators, consumers, and industry. We explored a phantom-based framework for assessing an important aspect of MAR performance: how applying MAR in the presence of metal affects model observer performance at a low-contrast detectability (LCD) task This work is, to our knowledge, the first model observer-based framework for the evaluation of MAR algorithms in the published literature. METHODS: We designed a numerical head phantom with metal implants. In order to incorporate an element of randomness, the phantom included a rotatable inset with an inhomogeneous background. We generated simulated projection data for the phantom. We applied two variants of a simple MAR algorithm, sinogram inpainting, to the projection data, that we reconstructed using filtered backprojection. To assess how MAR affected observer performance, we examined the detectability of a signal at the center of a region of interest (ROI) by a channelized Hotelling observer (CHO). As a figure of merit, we used the area under the ROC curve (AUC). RESULTS: We used simulation to test our framework on two variants of the MAR technique of sinogram inpainting. We found that our method was able to resolve the difference in two different MAR algorithms' effect on LCD task performance, as well as the difference in task performances when MAR was applied, vs not. CONCLUSION: We laid out a phantom-based framework for objective assessment of how MAR impacts low-contrast detectability, that we tested on two MAR algorithms. Our results demonstrate the importance of testing MAR performance over a range of object and imaging parameters, since applying MAR does not always improve the quality of an image for a given diagnostic task. Our framework is an initial step toward developing a more comprehensive objective assessment method for MAR, which would require developing additional phantoms and methods specific to various clinical applications of MAR, and increasing study efficiency.


Assuntos
Artefatos , Tomografia Computadorizada por Raios X , Algoritmos , Metais , Imagens de Fantasmas
2.
Eur J Neurol ; 25(7): 907-e66, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29577526

RESUMO

BACKGROUND AND PURPOSE: Impaired bulbar functions of speech and swallowing are among the most serious consequences of amyotrophic lateral sclerosis (ALS). Despite this, clinical trials in ALS have rarely emphasized bulbar function as an endpoint. The rater-administered Amyotrophic Lateral Sclerosis Functional Rating Scale-Revised (ALSFRS-R) or various quality-of-life measures are commonly used to measure symptomatic benefit. Accordingly, we sought to evaluate the utility of measures specific to bulbar function in ALS. METHODS: We assessed bulbar functions in 120 patients with ALS, with clinicians first making direct observations of the degree of speech, swallowing and salivation impairment in these subjects. Clinical diagnosis of bulbar impairment was then compared with ALSFRS-R scores, speech rate, time to swallow liquids and solids, and scores obtained when patients completed visual analog scales (VASs) and the newly-developed 21-question self-administered Center for Neurologic Study Bulbar Function Scale (CNS-BFS). RESULTS: The CNS-BFS, ALSFRS-R, VAS and timed speech and swallowing were all concordant with clinician diagnosis. The self-report CNS-BFS and ALSFRS-R bulbar subscale best predicted clinician diagnosis with misclassification rates of 8% and 14% at the optimal cut-offs, respectively. In addition, the CNS-BFS speech and swallowing subscales outperformed both the bulbar component of the ALSFRS-R and speech and swallowing VASs when correlations were made between these scales and objective measures of timed reading and swallowing. CONCLUSIONS: Based on these findings and its relative ease of administration, we conclude that the CNS-BFS is a useful metric for assessing bulbar function in patients with ALS.


Assuntos
Esclerose Lateral Amiotrófica/diagnóstico , Deglutição/fisiologia , Fala/fisiologia , Idoso , Esclerose Lateral Amiotrófica/fisiopatologia , Autoavaliação Diagnóstica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Qualidade de Vida
3.
Diabetes Obes Metab ; 17(7): 649-58, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25772666

RESUMO

AIMS: To summarize evidence from and assess the quality of published systematic reviews evaluating the safety, efficacy and effectiveness of incretin-based medications used in the treatment of type 2 diabetes. METHODS: We identified systematic reviews of randomized controlled trials or observational studies published in any language that evaluated the safety and/or effectiveness of glucagon-like peptide-1 (GLP-1) receptor agonists or dipeptidyl-peptidase-4 (DPP-4) inhibitors. Data sources used include the Cochrane Library, PubMed, EMBASE, Web of Science, International Pharmaceutical Abstracts, table of contents of diabetes journals, and hand-searching of reference lists and clinical practice guidelines. The methodological quality of systematic reviews was independently assessed by two reviewers using the Assessment of Multiple Systematic Reviews (AMSTAR) checklist. Our study protocol was registered with PROSPERO (2013:CRD42013005149). The primary outcomes were pooled treatment effect estimates for glycaemic control, macrovascular and microvascular complications, and hypoglycaemic events. RESULTS: We identified 467 unique citations of which 84 systematic reviews met our inclusion criteria. There were 51 reviews that evaluated GLP-1 receptor agonists and 64 reviews that evaluated DPP-4 inhibitors. The median (interquartile range) AMSTAR score was 6 (3) out of 11 for quantitative and 1 (1) for non-quantitative reviews. Among the 66 quantitative systematic reviews, there were a total of 718 pooled treatment effect estimates reported for our primary outcomes and 1012 reported pooled treatment effect estimates for secondary outcomes. CONCLUSIONS: Clinicians and policy makers, when using the results of systematic reviews to inform decision-making with regard to round clinical care or healthcare policies for incretin-based medications, should consider the variability in quality of reviews.


Assuntos
Diabetes Mellitus Tipo 2/tratamento farmacológico , Inibidores da Dipeptidil Peptidase IV/uso terapêutico , Receptor do Peptídeo Semelhante ao Glucagon 1/agonistas , Incretinas/uso terapêutico , Literatura de Revisão como Assunto , Humanos , Estudos Observacionais como Assunto , Ensaios Clínicos Controlados Aleatórios como Assunto
4.
Med Phys ; 41(7): 071904, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24989382

RESUMO

PURPOSE: Iterative reconstruction (IR) algorithms have the potential to reduce radiation dose in CT diagnostic imaging. As these algorithms become available on the market, a standardizable method of quantifying the dose reduction that a particular IR method can achieve would be valuable. Such a method would assist manufacturers in making promotional claims about dose reduction, buyers in comparing different devices, physicists in independently validating the claims, and the United States Food and Drug Administration in regulating the labeling of CT devices. However, the nonlinear nature of commercially available IR algorithms poses challenges to objectively assessing image quality, a necessary step in establishing the amount of dose reduction that a given IR algorithm can achieve without compromising that image quality. This review paper seeks to consolidate information relevant to objectively assessing the quality of CT IR images, and thereby measuring the level of dose reduction that a given IR algorithm can achieve. METHODS: The authors discuss task-based methods for assessing the quality of CT IR images and evaluating dose reduction. RESULTS: The authors explain and review recent literature on signal detection and localization tasks in CT IR image quality assessment, the design of an appropriate phantom for these tasks, possible choices of observers (including human and model observers), and methods of evaluating observer performance. CONCLUSIONS: Standardizing the measurement of dose reduction is a problem of broad interest to the CT community and to public health. A necessary step in the process is the objective assessment of CT image quality, for which various task-based methods may be suitable. This paper attempts to consolidate recent literature that is relevant to the development and implementation of task-based methods for the assessment of CT IR image quality.


Assuntos
Algoritmos , Tomografia Computadorizada por Raios X/métodos , Humanos , Modelos Teóricos , Imagens de Fantasmas , Doses de Radiação , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/normas
5.
Clin Pharmacol Ther ; 84(4): 523-5, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18716616

RESUMO

The US Food and Drug Administration (FDA) is committed to working with the oncology community to expedite the drug evaluation process in view of the many promising new oncology drugs under laboratory development and the time and expense required for such new drugs to reach the patient population. One significant advance would be to enable quantitative imaging as a tumor biomarker. The FDA is working with the pharmaceutical industry, academia, and sister stakeholders in the government, primarily through collaborative educational and research efforts, to identify how imaging can serve this function.


Assuntos
Diagnóstico por Imagem , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , United States Food and Drug Administration , Antineoplásicos/uso terapêutico , Ensaios Clínicos como Assunto , Aprovação de Drogas , Humanos , Neoplasias Pulmonares/tratamento farmacológico , National Institutes of Health (U.S.) , Imagens de Fantasmas , Prognóstico , Projetos de Pesquisa , Software/normas , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/normas , Estados Unidos
7.
Trends Pharmacol Sci ; 21(1): 19-23, 2000 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-10637651

RESUMO

In the past decade, there has been a vast increase in the amount of gene sequence information that has the potential to revolutionize the way diseases are both categorized and treated. Old diagnoses, largely anatomical or descriptive in nature, are likely to be superceded by the molecular characterization of the disease. The recognition that certain genes drive key disease processes will also enable the rational design of gene-specific therapeutics. Antisense oligonucleotides represent a technology that should play multiple roles in this process.


Assuntos
Oligonucleotídeos Antissenso , Animais , Humanos , Oligonucleotídeos Antissenso/síntese química , RNA Mensageiro/biossíntese , RNA Mensageiro/genética
8.
IEEE Trans Med Imaging ; 19(12): 1160-7, 2000 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-11212364

RESUMO

A minimum-norm least-squares image-reconstruction method for the reconstruction of magnetic resonance images from non-Cartesian sampled data is proposed. The method is based on a general formalism for continuous-to-discrete mapping and pseudoinverse calculation. It does not involve any regridding or interpolation of the data and therefore the methodology differs fundamentally from existing regridding-based methods. Moreover, the method uses a continuous representation of objects in the image domain instead of a discretized representation. Simulations and experiments show the possibilities of the method in both radial and spiral imaging. Simulations revealed that minimum-norm least-squares image reconstruction can result in a drastic decrease of artifacts compared with regridding-based reconstruction. Besides, both in vivo and phantom experiments showed that minimum-norm least-squares image reconstruction leads to contrast improvement and increased signal-to-noise ratio compared with image reconstruction based on regridding. As an appendix, an analytical calculation of the raw data corresponding to the well-known Shepp and Logan software head phantom is presented.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética , Humanos
13.
Am J Pathol ; 152(2): 457-68, 1998 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-9466572

RESUMO

Systemically administered interleukin (IL)-12 causes liver inflammation in mice characterized by Kupffer cell proliferation and hypertrophy, hepatocyte necrosis, and multifocal accumulations of leukocytes in the hepatic parenchyma and around portal tracts and central veins. We have used both immunohistochemical staining and radiolabeled antibody quantitation to examine adhesion molecule expression in the livers of mice dosed daily with murine IL-12. Cells infiltrating livers of IL-12-treated mice were primarily mononuclear leukocytes expressing LFA-1, VLA-4, MAC-1, and CD18 adhesion molecules but little L-selectin. Kupffer cells constitutively expressed LFA-1 and smaller amounts of MAC-1, and high levels of ICAM-1 were constitutively expressed by liver sinusoidal lining cells, portal tract, and central vein endothelia. With IL-12 treatment, existing ICAM-1 expression was up-regulated and de novo expression occurred along bile duct epithelia. VCAM-1 levels were dramatically increased, with induced expression occurring along portal tract and central vein endothelia and scattered bile duct epithelial cells and in aggregations of cells in perivascular areas and the liver parenchyma. Although constitutive expression of E- and P-selectin was negligible, Il-12 induced a moderate rise in E-selectin levels. These increases in adhesion molecule expression may have implications for the therapeutic use of IL-12, especially in patients with liver disease or autoimmune conditions where augmented adhesion molecule expression may be critical to disease pathogenesis.


Assuntos
Moléculas de Adesão Celular/metabolismo , Interleucina-12/farmacologia , Fígado/efeitos dos fármacos , Fígado/metabolismo , Animais , Endotélio Vascular/metabolismo , Feminino , Imuno-Histoquímica , Molécula 1 de Adesão Intercelular/metabolismo , Leucócitos/classificação , Leucócitos/metabolismo , Leucócitos/patologia , Fígado/patologia , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Endogâmicos , Selectinas/metabolismo , Molécula 1 de Adesão de Célula Vascular/metabolismo
14.
IEEE Trans Med Imaging ; 16(5): 591-7, 1997 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-9368114

RESUMO

The method of constrained reconstruction, previously applied to magnetic resonance imaging (MRI), is extended to magnetic resonance spectroscopy. This method assumes a model for the MR signal. The model parameters are estimated directly from the phase encoded data. This process obviates the need for the fast Fourier transform (FFT) (which often exhibits limited resolution and ringing artifact). The technique is tested on simulated data, phantom data, and data acquired from human liver in vivo. In each case, constrained reconstruction offers spatial resolution superior to that obtained with the FFT.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Espectroscopia de Ressonância Magnética , Artefatos , Simulação por Computador , Análise de Fourier , Humanos , Fígado/metabolismo , Imageamento por Ressonância Magnética , Modelos Químicos , Músculo Esquelético/metabolismo , Imagens de Fantasmas , Fosfatos/química , Fosfocreatina/metabolismo , Isótopos de Fósforo
15.
J Neuroimmunol ; 62(2): 153-60, 1995 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-7499503

RESUMO

Experimental autoimmune encephalomyelitis (EAE) is a demyelinating disease of the central nervous system (CNS) induced in rodents by activated CD4+ T cells specific for various myelin proteins such as myelin basic protein and proteolipid protein. The disease is characterized by breach of the blood-brain barrier, perivascular infiltration of leukocytes into the CNS, local inflammation and demyelination in the form of plaques. In this study, we evaluated the effect of administration of antibodies to two members of the beta 2 integrin sub-family of adhesion molecules, CD11a and CD11b, on the onset and progression of EAE. CD11a and CD11b are involved in cell-cell interactions leading to T cell and macrophage extravasation to inflammatory sites and T cell activation. Our results show that anti-CD11a antibodies could completely block the induction of EAE and anti-CD11b antibodies significantly delayed the onset and diminished the severity of clinical signs of EAE even when injections were initiated at the first appearance of clinical signs.


Assuntos
Anticorpos Monoclonais/uso terapêutico , Encefalomielite Autoimune Experimental/terapia , Antígeno-1 Associado à Função Linfocitária/fisiologia , Antígeno de Macrófago 1/fisiologia , Sequência de Aminoácidos , Animais , Feminino , Molécula 1 de Adesão Intercelular/fisiologia , Camundongos , Dados de Sequência Molecular
16.
J Emerg Med ; 13(4): 553-61, 1995.
Artigo em Inglês | MEDLINE | ID: mdl-7594381

RESUMO

The Division of Emergency Medicine at the University of Florida coordinates a unique program with the NASA John F. Kennedy Space Center (KSC) to provide emergency medical support (EMS) for the United States Space Transportation System. This report outlines the organization of the KSC EMS system, training received by physicians providing medical support, logistic and operational aspects of the mission, and experiences of team members. The participation of emergency physicians in support of manned space flight represents another way that emergency physicians provide leadership in prehospital care and disaster management.


Assuntos
Medicina Aeroespacial/educação , Medicina Aeroespacial/organização & administração , Educação Médica Continuada/organização & administração , Medicina de Emergência/educação , Medicina de Emergência/organização & administração , Currículo , Planejamento em Desastres/organização & administração , Florida , Humanos , Medicina do Trabalho/educação , Medicina do Trabalho/organização & administração , Estados Unidos , United States National Aeronautics and Space Administration
17.
Med Phys ; 22(7): 1057-61, 1995 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-7565380

RESUMO

Consensus has been developing over the past few decades on a number of measurements required for the laboratory assessment of medical imaging modalities. Nevertheless, understanding of the connection between these measurements and human observer performance in a broad range of tasks remains far from complete. Focusing primarily on projection radiography to provide concrete examples, this overview indicates areas in which consensus on methodology for physical image-quality measurement has been established. Concepts such as "noise equivalent quanta" (NEQ) and "detective quantum efficiency" (DQE) have been found useful for normalizing physical measurements on an absolute scale and for relating those measurements to the decision performance of a hypothetical "ideal observer" that effectively performs decision tasks from the image data. The connection between ideal observer performance and human performance, as determined by receiver operating characteristic (ROC) analysis, remains to be understood for many clinically relevant tasks.


Assuntos
Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Fenômenos Biofísicos , Biofísica , Estudos de Avaliação como Assunto , Humanos , Curva ROC , Intensificação de Imagem Radiográfica/métodos
18.
J Opt Soc Am A Opt Image Sci Vis ; 12(5): 834-52, 1995 May.
Artigo em Inglês | MEDLINE | ID: mdl-7730951

RESUMO

Figures of merit for image quality are derived on the basis of the performance of mathematical observers on specific detection and estimation tasks. The tasks include detection of a known signal superimposed on a known background, detection of a known signal on a random background, estimation of Fourier coefficients of the object, and estimation of the integral of the object over a specified region of interest. The chosen observer for the detection tasks is the ideal linear discriminant, which we call the Hotelling observer. The figures of merit are based on the Fisher information matrix relevant to estimation of the Fourier coefficients and the closely related Fourier crosstalk matrix introduced earlier by Barrett and Gifford [Phys. Med. Biol. 39, 451 (1994)]. A finite submatrix of the infinite Fisher information matrix is used to set Cramer-Rao lower bounds on the variances of the estimates of the first N Fourier coefficients. The figures of merit for detection tasks are shown to be closely related to the concepts of noise-equivalent quanta (NEQ) and generalized NEQ, originally derived for linear, shift-invariant imaging systems and stationary noise. Application of these results to the design of imaging systems is discussed.


Assuntos
Simulação por Computador , Processamento de Imagem Assistida por Computador/métodos , Modelos Biológicos , Análise de Fourier , Humanos
19.
Air Med J ; 14(1): 21-5, 1995.
Artigo em Inglês | MEDLINE | ID: mdl-10140974

RESUMO

INTRODUCTION: Flight crew perceptions of the effect of the rotary-wing environment on patient-care capabilities have not been subject to statistical analysis. We hypothesized that flight crew members perceived significant difficulties in performing patient-care tasks during air medical transport. METHODS: A survey was distributed to a convenience sample of flight crew members from 20 flight programs. Respondents were asked to compare the difficulty of performing patient-care tasks in rotary-wing and standard (emergency department or intensive care unit) settings. Demographic data collected on respondents included years of flight experience, flights per month, crew duty position and primary aircraft in which the respondent worked. Statistical analysis was performed as appropriate using Student's t-test, type III sum of squares, and analysis of variance. Alpha was defined as p < 0.05. RESULTS: Fifty-five percent of programs (90 individuals) responded. All tasks were significantly rated more difficult in the rotary-wing environment. Ratings were not significantly correlated with flight experience, duty position, flights per month or aircraft used. CONCLUSIONS: We conclude that the performance of patient-care tasks are perceived by air medical flight crew to be significantly more difficult during rotary-wing air medical transport than in hospital settings.


Assuntos
Resgate Aéreo/normas , Medicina de Emergência/normas , Ruído dos Transportes/efeitos adversos , Análise de Variância , Comunicação , Florida , Controle de Formulários e Registros , Humanos , Equipe de Assistência ao Paciente , Percepção
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...