Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Fetal Diagn Ther ; 49(9-10): 419-424, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36116430

RESUMO

INTRODUCTION: This report presents a rare case of spontaneous twin anemia-polycythemia sequence (TAPS) between two dichorionic fetuses in a spontaneous, homozygotic, dichorionic, triamniotic, triplet pregnancy treated with multiple intrauterine blood transfusions (IUTs) and partial exchange transfusions (PETs). CASE PRESENTATION: The pregnancy was diagnosed with stage IV TAPS at gestational week 25+1. The patient was treated with laser surgery combined with multiple IUTs and PETs. The triplets were delivered at a planned caesarean section at gestational week 28+1 with postnatal hemoglobin values of 18.21, 26.43, and 11.92 g/dL in triplet 1, 2, and 3, respectively. At 4 years of age, triplet 1 is considered healthy, triplet 2 is diagnosed with mild mental retardation, and triplet 3 with profound mental retardation and dystonic cerebral palsy. DISCUSSION: This is an extremely rare case of TAPS between dichorionic fetuses in a triplet pregnancy, and routine surveillance with measurement of middle cerebral artery peak systolic velocity in dichorionic pregnancies may contribute to the detection of similar cases in the future. Furthermore, this case contributes with rare long-term follow-up data of children treated for high-stage TAPS with multiple IUTs and PETs.


Assuntos
Transfusão Feto-Fetal , Deficiência Intelectual , Policitemia , Gravidez de Trigêmeos , Criança , Gravidez , Humanos , Feminino , Transfusão Feto-Fetal/complicações , Transfusão Feto-Fetal/diagnóstico por imagem , Transfusão Feto-Fetal/cirurgia , Cesárea , Policitemia/complicações , Policitemia/diagnóstico por imagem , Feto , Gravidez de Gêmeos
2.
Med Educ ; 56(6): 680-689, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35262226

RESUMO

BACKGROUND: Collaborative skills learning in the form of dyad learning compared with individual learning has been shown to lead to non-inferior skills retention and transfer. However, we have limited knowledge on which learning activities improve collaborative skills training and how the number of collaborators may impact skills transfer. We explored the effects of skills training individually, in dyads, triads or tetrads on learning activities during training and on subsequent skills transfer. METHODS: In a randomised, controlled study, participants completed a pre-post-transfer-test set-up in groups of one to four. Participants completed 2 hours of obstetric ultrasound training. In the dyad, triad and tetrad group participants took turns actively handling the ultrasound probe. All performances were rated by two blinded experts using the Objective Structured Assessment of Ultrasound Skills (OSAUS) scale and a Global Rating Scale (GRS). All training was video recorded, and learning activities were analysed using the Interactive-Constructive-Active-Passive (ICAP) framework. RESULTS: One hundred one participants completed the simulation-based training, and ninety-seven completed the transfer test. Performance scores improved significantly from pre- to post-test for all groups (p < 0.001, ηp2 = 0.55). However, group size did not affect transfer test performance on OSAUS scores (p = 0.13, ηp2 = 0.06) or GRS scores (p = 0.23, ηp2 = 0.05). ICAP analyses of training activities showed that time spent on non-learning and passive learning activities increased with group size (p < 0.001, ηp2 = 0.31), whereas time spent on constructive and interactive learning activities was constant between groups compared with singles (p < 0.001, ηp2 = 0.72). CONCLUSION: Collaborative skills learning in groups of up to four did not impair skills transfer despite less hands-on time. This may be explained by a compensatory shift towards constructive and interactive learning activities that outweigh the effect of shorter hands-on time.


Assuntos
Competência Clínica , Treinamento por Simulação , Avaliação Educacional , Humanos , Aprendizagem , Ultrassonografia
3.
Diabet Med ; 39(4): e14722, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34653280

RESUMO

OBJECTIVES: To explore the impact of anti-hypertensive treatment of pregnancy-induced hypertension on foetal growth and hemodynamics in women with pre-existing diabetes. METHODS: A prospective cohort study of 247 consecutive pregnant women with pre-existing diabetes (152 type 1 diabetes; 95 type 2 diabetes), where tight anti-hypertensive treatment was initiated and intensified (mainly with methyldopa) when office blood pressure (BP) ≥135/85 mmHg and home BP ≥130/80 mmHg. Foetal growth was assessed by ultrasound at 27, 33 and 36 weeks and foetal hemodynamics were assessed by ultrasound Doppler before and 1-2 weeks after initiation of anti-hypertensive treatment. RESULTS: In 215 initially normotensive women, anti-hypertensive treatment for pregnancy-induced hypertensive disorders was initiated in 42 (20%), whilst 173 were left untreated. Chronic hypertension was present in 32 (13%). Anti-hypertensive treatment for pregnancy-induced hypertensive disorders was not associated with foetal growth deviation (linear mixed model, p = 0.681). At 27 weeks, mainly before initiation of anti-hypertensive treatment, the prevalence of small foetuses with an estimated foetal weight <10th percentile was 12% in women initiating anti-hypertensive treatment compared with 4% in untreated women (p = 0.054). These numbers were close to the prevalence of birth weight ≤10th percentile (small for gestational age (SGA)) (17% vs. 4%, p = 0.003). Pulsatility index in the umbilical and middle cerebral artery remained stable after the onset of anti-hypertensive treatment in a representative subgroup (n = 12, p = 0.941 and p = 0.799, respectively). CONCLUSION: There is no clear indication that antihypertensive treatment causes harm in this particular at-high-risk group of pregnant women with diabetes, such that a larger well-designed study to determine the value of tight antihypertensive control would be worthwhile.


Assuntos
Diabetes Mellitus Tipo 2 , Hipertensão Induzida pela Gravidez , Complicações na Gravidez , Anti-Hipertensivos/uso terapêutico , Diabetes Mellitus Tipo 2/complicações , Diabetes Mellitus Tipo 2/tratamento farmacológico , Feminino , Desenvolvimento Fetal , Hemodinâmica , Humanos , Hipertensão Induzida pela Gravidez/tratamento farmacológico , Hipertensão Induzida pela Gravidez/epidemiologia , Gravidez , Gestantes , Estudos Prospectivos
4.
Fetal Diagn Ther ; 48(10): 720-737, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34818226

RESUMO

INTRODUCTION: The aim of this study was to obtain expert consensus on the content of a curriculum for learning chorionic villus sampling (CVS) and amniocentesis (AC) and the items of an assessment tool to evaluate CVS and AC competence. METHODS: We used a 3-round iterative Delphi process. A steering committee supervised all processes. Seven international collaborators were identified to expand the breadth of the study internationally. The collaborators invited fetal medicine experts to participate as panelists. In the first round, the panelists suggested content for a CVS/AC curriculum and an assessment tool. The steering committee organized and condensed the suggested items and presented them to the panelists in round 2. In the second round, the panelists rated and commented on the suggested items. The results were processed by the steering committee and presented to the panelists in the third round, where final consensus was obtained. Consensus was defined as support by more than 80% of the panelists for an item. RESULTS: Eighty-six experts agreed to participate in the study. The panelists represented 16 countries across 4 continents. The final list of curricular content included 12 theoretical and practical items. The final assessment tool included 11 items, systematically divided into 5 categories: pre-procedure, procedure, post-procedure, nontechnical skills, and overall performance. These items were provided with behavioral scale anchors to rate performance, and an entrustment scale was used for the final overall assessment. CONCLUSION: We established consensus among international fetal medicine experts on content to be included in a CVS/AC curriculum and on an assessment tool to evaluate CVS/AC skills. These results are important to help transition current training and assessment methods from a time- and volume-based approach to a competency-based approach which is a key step in improving patient safety and outcomes for the 2 most common invasive procedures in fetal medicine.


Assuntos
Amniocentese , Amostra da Vilosidade Coriônica , Amostra da Vilosidade Coriônica/efeitos adversos , Consenso , Feminino , Humanos , Gravidez
6.
J Ultrasound Med ; 36(1): 201-208, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27925649

RESUMO

OBJECTIVES: The aim of the study was to explore whether learning curves on a virtual-reality (VR) sonographic simulator can be used to predict subsequent learning curves on a physical mannequin and learning curves during clinical training. METHODS: Twenty midwives completed a simulation-based training program in transvaginal sonography. The training was conducted on a VR simulator as well as on a physical mannequin. A subgroup of 6 participants underwent subsequent clinical training. During each of the 3 steps, the participants' performance was assessed using instruments with established validity evidence, and they advanced to the next level only after attaining predefined levels of performance. The number of repetitions and time needed to achieve predefined performance levels were recorded along with the performance scores in each setting. Finally, the outcomes were correlated across settings. RESULTS: A good correlation was found between time needed to achieve predefined performance levels on the VR simulator and the physical mannequin (Pearson correlation coefficient .78; P < .001). Performance scores on the VR simulator correlated well to the clinical performance scores (Pearson correlation coefficient .81; P = .049). No significant correlations were found between numbers of attempts needed to reach proficiency across the 3 different settings. A post hoc analysis found that the 50% fastest trainees at reaching proficiency during simulation-based training received higher clinical performance scores compared to trainees with scores placing them among the 50% slowest (P = .025). CONCLUSIONS: Performances during simulation-based sonography training may predict performance in related tasks and subsequent clinical learning curves.


Assuntos
Competência Clínica/estatística & dados numéricos , Simulação por Computador , Curva de Aprendizado , Ultrassom/educação , Ultrassonografia , Adulto , Dinamarca , Feminino , Humanos , Manequins , Pessoa de Meia-Idade , Tocologia/educação , Tocologia/estatística & dados numéricos
7.
Med Educ ; 49(12): 1263-71, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26611191

RESUMO

OBJECTIVE: To provide a model for conducting cost-effectiveness analyses in medical education. The model was based on a randomised trial examining the effects of training midwives to perform cervical length measurement (CLM) as compared with obstetricians on patients' waiting times. (CLM), as compared with obstetricians. METHODS: The model included four steps: (i) gathering data on training outcomes, (ii) assessing total costs and effects, (iii) calculating the incremental cost-effectiveness ratio (ICER) and (iv) estimating cost-effectiveness probability for different willingness to pay (WTP) values. To provide a model example, we conducted a randomised cost-effectiveness trial. Midwives were randomised to CLM training (midwife-performed CLMs) or no training (initial management by midwife, and CLM performed by obstetrician). Intervention-group participants underwent simulation-based and clinical training until they were proficient. During the following 6 months, waiting times from arrival to admission or discharge were recorded for women who presented with symptoms of pre-term labour. Outcomes for women managed by intervention and control-group participants were compared. These data were then used for the remaining steps of the cost-effectiveness model. RESULTS: Intervention-group participants needed a mean 268.2 (95% confidence interval [CI], 140.2-392.2) minutes of simulator training and a mean 7.3 (95% CI, 4.4-10.3) supervised scans to attain proficiency. Women who were scanned by intervention-group participants had significantly reduced waiting time compared with those managed by the control group (n = 65; mean difference, 36.6 [95% CI 7.3-65.8] minutes; p = 0.008), which corresponded to an ICER of 0.45 EUR minute(-1) . For WTP values less than EUR 0.26 minute(-1) , obstetrician-performed CLM was the most cost-effective strategy, whereas midwife-performed CLM was cost-effective for WTP values above EUR 0.73 minute(-1) . CONCLUSION: Cost-effectiveness models can be used to link quality of care to training costs. The example used in the present study demonstrated that different training strategies could be recommended as the most cost-effective depending on administrators' willingness to pay per unit of the outcome variable.


Assuntos
Análise Custo-Benefício/métodos , Educação de Graduação em Medicina/economia , Ocupações em Saúde/educação , Qualidade da Assistência à Saúde , Medida do Comprimento Cervical , Feminino , Humanos , Tocologia/economia , Tocologia/educação , Unidade Hospitalar de Ginecologia e Obstetrícia/economia , Gravidez
8.
Acta Obstet Gynecol Scand ; 91(5): 546-51, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22348742

RESUMO

OBJECTIVE: To describe the incidence of placenta previa and to assess neonatal morbidity and mortality in pregnancies with placenta previa after adjustment for previous cesarean section, smoking, multiparity, maternal age and in vitro fertilization. DESIGN: National cohort study. SETTING: Danish national IVF-, birth- and patient registers. POPULATION: All pregnancies in Denmark from 1978-2006 and a subpopulation of all singleton pregnancies during the years 2001-2006 with placenta previa (n=1721) compared to pregnancies without this diagnosis. METHODS: Incidence rates and multivariate analysis. MAIN OUTCOME MEASURES: Gestational age, birthweight, Apgar score after five minutes, stillbirth, neonatal mortality and admittance to neonatal intensive care unit. RESULTS: The incidence of placenta previa in Denmark was 0.54% in 2006. Neonates born after pregnancies with placenta previa had a higher risk of being born at a gestational age below 37 weeks (OR 8.6; 95%CI 7.5-9.9), having an Apgar score of ≤7 at five minutes (OR 2.7; 95%CI 2.0-3.7), being transferred to a neonatal intensive care unit (OR 4.3; 95%CI 3.8-4.9) and for stillbirth and neonatal mortality combined (OR 1.8; 95%CI 1.1-3.0), compared with neonates born in pregnancies without placenta previa. No increased risk of being small-for-gestational age was found (OR 1.0; 95%CI 1.0-1.2). CONCLUSION: When adjusting for confounders, neonates born after pregnancies with placenta previa had a significantly higher risk of being born preterm, having a low Apgar score, being transferred to neonatal intensive care, and death.


Assuntos
Placenta Prévia/epidemiologia , Resultado da Gravidez/epidemiologia , Adulto , Índice de Apgar , Peso ao Nascer , Estudos de Casos e Controles , Cesárea/estatística & dados numéricos , Estudos de Coortes , Dinamarca/epidemiologia , Feminino , Idade Gestacional , Humanos , Incidência , Mortalidade Infantil , Recém-Nascido , Gravidez , Sistema de Registros , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...