Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Cancer Res Treat ; 53(1): 45-54, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32972044

RESUMO

PURPOSE: This study aimed to reduce radiation doses to the tongue, a patient-specific semi-customized tongue immobilization device (SCTID) was developed using a 3D printer for helical tomotherapy (HT) of nasopharyngeal cancer (NPCa). Dosimetric characteristics and setup stability of the SCTID were compared with those of a standard mouthpiece (SMP). MATERIALS AND METHODS: For displacement and robust immobilization of the tongue, the SCTID consists of four parts: upper and lower tooth stoppers, tongue guider, tongue-tip position guide bar, and connectors. With the SCTID and SMP, two sets of planning computed tomography and HT plans were obtained for 10 NPCa patients. Dosimetric and geometric characteristics were compared. Position reproducibility of the tongue with SCTID was evaluated by comparing with planned dose and adaptive accumulated dose of the tongue and base of the tongue based on daily setup mega-voltage computed tomography. RESULTS: Using the SCTID, the tongue was effectively displaced from the planning target volume compared to the SMP. The median mucosa of the tongue (M-tongue) dose was significantly reduced (20.7 Gy vs. 27.8 Gy). The volumes of the M-tongue receiving a dose of 15 Gy, 30 Gy, and 45 Gy and the volumes of the mucosa of oral cavity and oropharynx (M-OC/OP) receiving a dose of 45 Gy and 60 Gy were significantly lower than using the SMP. No significant differences was observed between the planned dose and the accumulated adaptive dose in any dosimetric characteristics of the tongue and base of tongue. CONCLUSION: SCTID can not only reduce the dose to the M-tongue and M-OC/OP dramatically, when compared to SMP, but also provide excellent reproducibility and easy visual verification.


Assuntos
Imageamento Tridimensional/métodos , Neoplasias Nasofaríngeas/radioterapia , Língua/patologia , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
2.
Radiat Oncol ; 14(1): 79, 2019 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-31088472

RESUMO

PURPOSE: To reduce radiation doses to the tongue, a patient-specific semi-customized tongue displacement device (SCTDD) was developed using a 3D printer (3DP) for head and neck (H&N) radiation therapy (RT). Dosimetric characteristics of the SCTDD were compared with those of a standard mouthpiece (SMP). MATERIALS AND METHODS: The SCTDD consists of three parts: a mouthpiece, connector with an immobilization mask, and tongue displacer, which can displace the tongue to the contralateral side of the planning target volume. Semi-customization was enabled by changing the thickness and length of the SCTDD. The instrument was printed using a 3DP with a biocompatible material. With the SCTDD and SMP, two sets of planning computed tomography (CT) and tomotherapy plans were obtained for seven H&N cancer patients. Dosimetric and geometric characteristics were compared. RESULTS: Using the SCTDD, the tongue was effectively displaced from the planning target volume without significant tongue volume change compared to the SMP. The median tongue dose was significantly reduced (29.6 Gy vs. 34.3 Gy). The volumes of the tongue receiving a dose of 15 Gy, 30 Gy, 35 Gy, 45 Gy, and 60 Gy were significantly lower than using the SMP. CONCLUSION: The SCTDD significantly decreased the radiation dose to the tongue compared to the SMP, which may potentially reduce RT-related tongue toxicity.


Assuntos
Neoplasias de Cabeça e Pescoço/radioterapia , Órgãos em Risco/efeitos da radiação , Impressão Tridimensional/instrumentação , Planejamento da Radioterapia Assistida por Computador/métodos , Língua/fisiopatologia , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos , Língua/efeitos da radiação
3.
Breast J ; 25(4): 682-686, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31077484

RESUMO

The purpose of this study was to analyze the effectiveness of electron beam therapy (EBT) with patient-tailored bolus (PTB) using three-dimensional printing technology to reduce heart and lung doses during post-mastectomy radiotherapy (PMRT). For 28 patients with left breast cancer, we designed customized virtual bolus for PMRT to compensate for surface irregularities on computed tomography images and developed optimized plans for EBT. As comparison between the PTB and tangential plans, the PTB plan reduced unnecessary exposure to heart and ipsilateral lung with better target coverage compared with the tangential technique.


Assuntos
Coração , Radioterapia/métodos , Neoplasias Unilaterais da Mama/radioterapia , Neoplasias Unilaterais da Mama/cirurgia , Adulto , Idoso , Feminino , Humanos , Pulmão , Mastectomia , Pessoa de Meia-Idade , Tratamentos com Preservação do Órgão , Impressão Tridimensional , Radiodermite , Radioterapia/efeitos adversos , Dosagem Radioterapêutica , Tomografia Computadorizada por Raios X , Neoplasias Unilaterais da Mama/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...