Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Clin Med ; 12(16)2023 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-37629360

RESUMO

Transcatheter aortic valve replacement (TAVR) is a minimally invasive therapeutic procedure with a consistent, linear increase in the number of implantations worldwide. Recently, TAVR has been rapidly expanding into lower-risk populations. Sporadic cases of late prosthesis-related Stanford type A dissection have been documented in self-expanding, as well as balloon-expandable TAVR valves, manifested primarily as acute aortic syndrome. We present the case of a 76-year-old male, who experienced refractory in-hospital cardiac arrest with non-shockable rhythm due to the obstruction of coronary flow caused by aortic dissection type A, with entry directly adjacent to the aortic prosthesis according to autopsy. The patient died despite the engagement of extracorporeal cardiopulmonary resuscitation. Aortic dissection developed one year after a transfemoral TAVR procedure using an Edwards SAPIEN 3 29 mm self-expanding valve. TAVR-associated late aortic dissection type A represents a rare, life-threatening condition with various clinical manifestations. The risk factors have not been well described and the differential diagnosis may be challenging. As the number of TAVR recipients and their life expectancy is increasing, we may face this complication more often in future.

2.
Circulation ; 147(6): 454-464, 2023 02 07.
Artigo em Inglês | MEDLINE | ID: mdl-36335478

RESUMO

BACKGROUND: Veno-arterial extracorporeal membrane oxygenation (VA-ECMO) is increasingly being used for circulatory support in patients with cardiogenic shock, although the evidence supporting its use in this context remains insufficient. The ECMO-CS trial (Extracorporeal Membrane Oxygenation in the Therapy of Cardiogenic Shock) aimed to compare immediate implementation of VA-ECMO versus an initially conservative therapy (allowing downstream use of VA-ECMO) in patients with rapidly deteriorating or severe cardiogenic shock. METHODS: This multicenter, randomized, investigator-initiated, academic clinical trial included patients with either rapidly deteriorating or severe cardiogenic shock. Patients were randomly assigned to immediate VA-ECMO or no immediate VA-ECMO. Other diagnostic and therapeutic procedures were performed as per current standards of care. In the early conservative group, VA-ECMO could be used downstream in case of worsening hemodynamic status. The primary end point was the composite of death from any cause, resuscitated circulatory arrest, and implementation of another mechanical circulatory support device at 30 days. RESULTS: A total of 122 patients were randomized; after excluding 5 patients because of the absence of informed consent, 117 subjects were included in the analysis, of whom 58 were randomized to immediate VA-ECMO and 59 to no immediate VA-ECMO. The composite primary end point occurred in 37 (63.8%) and 42 (71.2%) patients in the immediate VA-ECMO and the no early VA-ECMO groups, respectively (hazard ratio, 0.72 [95% CI, 0.46-1.12]; P=0.21). VA-ECMO was used in 23 (39%) of no early VA-ECMO patients. The 30-day incidence of resuscitated cardiac arrest (10.3.% versus 13.6%; risk difference, -3.2 [95% CI, -15.0 to 8.5]), all-cause mortality (50.0% versus 47.5%; risk difference, 2.5 [95% CI, -15.6 to 20.7]), serious adverse events (60.3% versus 61.0%; risk difference, -0.7 [95% CI, -18.4 to 17.0]), sepsis, pneumonia, stroke, leg ischemia, and bleeding was not statistically different between the immediate VA-ECMO and the no immediate VA-ECMO groups. CONCLUSIONS: Immediate implementation of VA-ECMO in patients with rapidly deteriorating or severe cardiogenic shock did not improve clinical outcomes compared with an early conservative strategy that permitted downstream use of VA-ECMO in case of worsening hemodynamic status. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT02301819.


Assuntos
Oxigenação por Membrana Extracorpórea , Parada Cardíaca , Humanos , Choque Cardiogênico/diagnóstico , Choque Cardiogênico/terapia , Oxigenação por Membrana Extracorpórea/métodos , Hemodinâmica , Mortalidade Hospitalar , Estudos Retrospectivos
3.
J Pers Med ; 12(12)2022 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-36556249

RESUMO

Veno-venous extracorporeal membrane oxygenation (VV-ECMO) is a life-saving treatment for respiratory failure that may serve as a bridge to patient recovery or lung transplantation. In COVID-19, recovery is somewhat unpredictable and occasionally occurs after >100 days on VV-ECMO support. Thus, determining therapy cessation may be difficult. We report the case of a 59-year-old male without specific risk factors admitted to a tertiary center for rapidly progressive respiratory failure due to severe COVID-19, despite aggressive mechanical ventilatory support. Immediate insertion of VV-ECMO was associated with prompt resolution of hypoxemia and hypercapnia; however, all therapeutic efforts to wean the patient from VV-ECMO failed. During the prolonged hospitalization on VV-ECMO, sepsis was the most life-threatening complication. The patient overcame roughly 40 superinfections, predominantly affecting the respiratory tract, and spent 183 days on antimicrobial treatment. Although the function of other organ systems was generally stable, gradually progressive right ventricular dysfunction due to precapillary pulmonary hypertension required increasing doses of inotropes. A successful lung transplantation was performed after 207 days of VV-ECMO support. The present case provides evidence for prolonged VV-ECMO therapy as a bridge to lung transplantation in severe COVID-19 despite numerous, predominantly infectious complications.

4.
Sci Rep ; 12(1): 17076, 2022 10 12.
Artigo em Inglês | MEDLINE | ID: mdl-36224296

RESUMO

Venoarterial extracorporeal membrane oxygenation (VA-ECMO) is widely used in the treatment of patients experiencing cardiogenic shock (CS). However, increased VA-ECMO blood flow (EBF) may significantly impair left ventricular (LV) performance. The objective of the present study was to assess the effect of VA-ECMO on LV function in acute CS with concomitant severe aortic stenosis (AS) or mitral regurgitation (MR) in a porcine model. Eight female swine (45 kg) underwent VA-ECMO implantation under general anaesthesia and mechanical ventilation. Acute CS was induced by global myocardial hypoxia. Subsequently, severe AS was simulated by obstruction of the aortic valve, while severe MR was induced by mechanical destruction of the mitral valve. Haemodynamic and LV performance variables were measured at different rates of EBF rates (ranging from 1 to 4 L/min), using arterial and venous catheters, a pulmonary artery catheter, and LV pressure-volume catheter. Data are expressed as median (interquartile range). Myocardial hypoxia resulted in declines in cardiac output to 2.7 (1.9-3.1) L/min and LV ejection fraction to 15.2% (10.5-19.3%). In severe AS, increasing EBF from 1 to 4 L/min was associated with a significant elevation in mean arterial pressure (MAP), from 33.5 (24.2-34.9) to 56.0 (51.9-73.3) mmHg (P ˂ 0.01). However, LV volumes (end-diastolic, end-systolic, stroke) remained unchanged, and LV end-diastolic pressure (LVEDP) significantly decreased from 24.9 (21.2-40.0) to 19.1 (15.2-29.0) mmHg (P ˂ 0.01). In severe MR, increasing EBF resulted in a significant elevation in MAP from 49.0 (28.0-53.4) to 72.5 (51.4-77.1) mmHg (P ˂ 0.01); LV volumes remained stable and LVEDP increased from 17.1 (13.7-19.1) to 20.8 (16.3-25.6) mmHg (P ˂ 0.01). Results of this study indicate that the presence of valvular heart disease may alleviate negative effect of VA-ECMO on LV performance in CS. Severe AS fully protected against LV overload, and partial protection was also detected with severe MR, although at the cost of increased LVEDP and, thus, higher risk for pulmonary oedema.


Assuntos
Estenose da Valva Aórtica , Oxigenação por Membrana Extracorpórea , Insuficiência da Valva Mitral , Animais , Oxigenação por Membrana Extracorpórea/métodos , Feminino , Hipóxia , Insuficiência da Valva Mitral/terapia , Choque Cardiogênico/terapia , Suínos , Função Ventricular Esquerda/fisiologia
5.
Int J Mol Sci ; 24(1)2022 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-36613937

RESUMO

There are substantial differences in autonomic nervous system activation among heart (cardiac) failure (CF) patients. The effect of acute CF on autonomic function has not been well explored. The aim of our study was to assess the effect of experimental acute CF on heart rate variability (HRV). Twenty-four female pigs with a mean body weight of 45 kg were used. Acute severe CF was induced by global myocardial hypoxia. In each subject, two 5-min electrocardiogram segments were analyzed and compared: before the induction of myocardial hypoxia and >60 min after the development of severe CF. HRV was assessed by time-domain, frequency-domain and nonlinear analytic methods. The induction of acute CF led to a significant decrease in cardiac output, left ventricular ejection fraction and an increase in heart rate. The development of acute CF was associated with a significant reduction in the standard deviation of intervals between normal beats (50.8 [20.5−88.1] ms versus 5.9 [2.4−11.7] ms, p < 0.001). Uniform HRV reduction was also observed in other time-domain and major nonlinear analytic methods. Similarly, frequency-domain HRV parameters were significantly changed. Acute severe CF induced by global myocardial hypoxia is associated with a significant reduction in HRV.


Assuntos
Insuficiência Cardíaca , Isquemia Miocárdica , Feminino , Suínos , Animais , Frequência Cardíaca/fisiologia , Volume Sistólico , Função Ventricular Esquerda/fisiologia , Hipóxia
6.
J Appl Biomed ; 19(3): 133-141, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34907756

RESUMO

AIMS: To test the hypothesis that spinal cord stimulation (SCS) acutely improves heart rate variability (HRV) and baroreceptor sensitivity (BRS) in patients with heart failure (HF). METHODS: SCS (15 minutes) was delivered in four different settings: 90% of maximal tolerated stimulation amplitude (MTA) targeting the T1-T4 spinal cord segments (SCS90T1-4), 60% of MTA (SCS60T1-4), 90% of MTA with cranial (SCS90CR) and caudal (SCS90CA) electrode configuration. HRV and BRS were recorded continuously and stimulation was compared to device off. RESULTS: Fifteen HF patients were included. SCS90T1-4 did not change the standard deviation of intervals between normal beats (SDNN, p = 0.90), BRS (p = 0.55) or other HRV parameters. In patients with baseline SDNN <50 ms, SCS90T1-4 significantly increased SDNN (p = 0.004). CONCLUSIONS: Acute SCS at 60-90% of MTA targeting upper thoracic spinal cord segments does not improve autonomic balance or baroreceptor sensitivity in unselected patients with heart failure but may improve HRV in patients with low SDNN.


Assuntos
Insuficiência Cardíaca , Estimulação da Medula Espinal , Humanos , Sistema Nervoso Autônomo , Insuficiência Cardíaca/terapia , Frequência Cardíaca/fisiologia
7.
J Cardiovasc Transl Res ; 14(6): 1043-1050, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-33974231

RESUMO

The evidence supporting surgical aneurysmectomy in ischemic heart failure is inconsistent. The aim of the study was to describe long-term effect of minimally invasive hybrid transcatheter and minithoracotomy left ventricular (LV) reconstruction in patients with ischemic cardiomyopathy. Twenty-three subjects with transmural anterior wall scarring, LV ejection fraction 15-45%, and New York Heart Association class ≥ II were intervened using Revivent TC anchoring system. LV end-systolic volume index was reduced from 73.2 ± 27 ml at baseline to 51.5 ± 22 ml after 6 months (p < 0.001), 49.9 ± 20 ml after 2 years (p < 0.001), and 56.1 ± 16 ml after 5 years (p = 0.047). NYHA class improved significantly at 5 years compared to baseline. Six-min walk test distance increased at 2 years compared to the 6-month visit. Hybrid LV reconstruction using the anchoring system provides significant and durable LV volume reduction during 5-year follow-up in preselected patients with ischemic heart failure. Legend: Hybrid left ventricular reconstruction using the anchoring system provides significant and durable LV volume reduction throughout 5-year follow-up in preselected patients with ischemic heart failure.


Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Cardiomiopatias/cirurgia , Isquemia Miocárdica/cirurgia , Procedimentos de Cirurgia Plástica/métodos , Disfunção Ventricular Esquerda/cirurgia , Cardiomiopatias/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/diagnóstico por imagem , Estudos Prospectivos , Volume Sistólico , Disfunção Ventricular Esquerda/diagnóstico por imagem , Teste de Caminhada
8.
Crit Care ; 23(1): 364, 2019 11 21.
Artigo em Inglês | MEDLINE | ID: mdl-31752966

RESUMO

BACKGROUND: Continuous, reliable evaluation of left ventricular (LV) contractile function in patients with advanced heart failure requiring intensive care remains challenging. Continual monitoring of dP/dtmax from the arterial line has recently become available in hemodynamic monitoring. However, the relationship between arterial dP/dtmax and LV dP/dtmax remains unclear. This study aimed to determine the relationship between arterial dP/dtmax and LV dP/dtmax assessed using echocardiography in patients with acute heart failure. METHODS: Forty-eight patients (mean age 70.4 years [65% male]) with acute heart failure requiring intensive care and hemodynamic monitoring were recruited. Hemodynamic variables, including arterial dP/dtmax, were continually monitored using arterial line pressure waveform analysis. LV dP/dtmax was assessed using continuous-wave Doppler analysis of mitral regurgitation flow. RESULTS: Values from continual arterial dP/dtmax monitoring were significantly correlated with LV dP/dtmax assessed using echocardiography (r = 0.70 [95% confidence interval (CI) 0.51-0.82]; P < 0.0001). Linear regression analysis revealed that LV dP/dtmax = 1.25 × (arterial dP/dtmax) (P < 0.0001). Arterial dP/dtmax was also significantly correlated with stroke volume (SV) (r = 0.63; P < 0.0001) and cardiac output (CO) (r = 0.42; P = 0.0289). In contrast, arterial dP/dtmax was not correlated with SV variation, dynamic arterial elastance, heart rate, systemic vascular resistance (SVR), or mean arterial pressure. Markedly stronger agreement between arterial and LV dP/dtmax was observed in subgroups with higher SVR (N = 28; r = 0.91; P <  0.0001), lower CO (N = 26; r = 0.81; P <  0.0001), and lower SV (N = 25; r = 0.60; P = 0.0014). A weak correlation was observed in the subjects with lower SVR (N = 20; r = 0.61; P = 0.0004); in the subgroups with higher CO (N = 22) and higher SV (N = 23), no significant correlation was found. CONCLUSION: Our results suggest that in patients with acute heart failure requiring intensive care with an arterial line, continuous calculation of arterial dP/dtmax may be used for monitoring LV contractility, especially in those with higher SVR, lower CO, and lower SV, such as in patients experiencing cardiogenic shock. On the other hand, there was only a weak or no significant correlation in the subgroups with higher CO, higher SV, and lower SVR.


Assuntos
Ecocardiografia Doppler/métodos , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/fisiopatologia , Frequência Cardíaca/fisiologia , Contração Miocárdica/fisiologia , Função Ventricular Esquerda/fisiologia , Idoso , Idoso de 80 Anos ou mais , Débito Cardíaco/fisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto
9.
Scand Cardiovasc J ; 51(3): 143-152, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28335644

RESUMO

OBJECTIVES: The objective of this pilot study was to describe the impact of paced heart rate on left ventricular (LV) mechanical dyssynchrony in synchronous compared to dyssynchronous pacing modes in patients with heart failure. METHODS: Echocardiography was performed in 14 cardiac resynchronization therapy (CRT) patients at paced heart rates of 70 and 90 bpm in synchronous- (CRT), and dyssynchronous (atrial pacing + wide QRS activation) pacing modes. LV dyssynchrony was quantified using the 12-segment standard deviation model (Ts-SD) derived from Tissue Doppler Imaging. In addition, cardiac cycle intervals were assessed using cardiac state diagrams and stroke volume (SV) and filling pressure were estimated. RESULTS: Ts-SD decreased significantly with CRT at 90 bpm (25 ± 12 ms) compared to 70 bpm (35 ± 15 ms, p = .01), but remained unchanged with atrial pacing at different paced heart rates (p = .96). The paced heart rate dependent reduction in Ts-SD was consistent when Ts-SD was indexed to average Ts and systolic time interval. Cardiac state diagram derived analysis of cardiac cycle intervals demonstrated a significant reduction of the pre-ejection interval and an increase in diastole with CRT compared to atrial pacing. SV was maintained at the higher paced heart rate with CRT pacing but decreased with atrial pacing. DISCUSSION: Due to the small sample size in this pilot study general and firm conclusions are difficult to render. However, the data suggest that pacing at higher heart rates acutely reduces remaining LV dyssynchrony during CRT, but not during atrial pacing with dyssynchronous ventricular activation. These results need confirmation in a larger patient cohort.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Insuficiência Cardíaca/terapia , Frequência Cardíaca , Disfunção Ventricular Esquerda/terapia , Função Ventricular Esquerda , Idoso , Terapia de Ressincronização Cardíaca/efeitos adversos , Ecocardiografia Doppler em Cores , Ecocardiografia Doppler de Pulso , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/fisiopatologia , Pressão Ventricular
11.
Pacing Clin Electrophysiol ; 40(5): 504-513, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28206674

RESUMO

BACKGROUND: Spinal cord stimulation (SCS) reduces sympathetic activity in animal models of heart failure with reduced ejection fraction (HF) but limited data exist of SCS in patients with HF. The aim of the present study was to test the primary hypothesis that SCS reduces cardiac sympathetic nerve activity in HF patients. Secondary hypotheses were that SCS improves left ventricular function and dimension, exercise capacity, and clinical variables relevant to HF. METHODS: HF patients with a SCS device previously participating in the DEFEAT-HF trial were included in this crossover study with 6-week intervention periods (SCS-ON and SCS-OFF). SCS (50 Hz, 210-µs pulse duration, aiming at T2-T4 segments) was delivered for 12 hours daily. Indices of myocardial sympathetic neuronal function (heart-to-mediastinum ratio, HMR) and activity (washout rate, WR) were assessed using 123 I-metaiodobenzylguanidine (MIBG) scintigraphy. Echocardiography, exercise testing, and clinical data collection were also performed. RESULTS: We included 13 patients (65.3 ± 8.0 years, nine males) and MIBG scintigraphy data were available in 10. HMR was not different comparing SCS-ON (1.37 ± 0.16) and SCS-OFF (1.41 ± 0.21, P = 0.46). WR was also unchanged comparing SCS-ON (41.5 ± 5.3) and SCS-OFF (39.1 ± 5.8, P = 0.30). Similarly, average New York Heart Association class (2.4 ± 0.5 vs 2.3 ± 0.6, P = 0.34), quality of life score (24 ± 16 vs 24 ± 16, P = 0.94), and left ventricular dimension and function as well as exercise capacity were all unchanged comparing SCS-ON and SCS-OFF. CONCLUSION: In patients with HF, SCS (12 hours daily, targeting the T2-T4 segments of the spinal cord) does not appear to influence cardiac sympathetic neuronal activity or function as assessed by MIBG scintigraphy.


Assuntos
Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Coração/inervação , Coração/fisiopatologia , Estimulação da Medula Espinal/métodos , Medula Espinal/fisiopatologia , Sistema Nervoso Simpático/fisiopatologia , Idoso , Feminino , Coração/diagnóstico por imagem , Humanos , Masculino , Medula Espinal/diagnóstico por imagem , Resultado do Tratamento
12.
Vnitr Lek ; 60(2): 110-3, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24754414

RESUMO

STUDY OBJECTIVE: To compare parameters of diastolic function as assessed by radionuclide ventriculography (RNVG) and Doppler echocardiography (ECHO) in the patients with chronic heart failure and reduced ejection fraction (HF REF). PATIENTS AND METHODS: RNVG and ECHO were performed on the same day in 40 patients with systolic chronic HF, NYHA II and III, with LV EF < 50 % and sinus rhythm, followed at tertiary HF clinic. Diastolic function was assessed by RNVG using parameters: PFR (peak filling rate [% SV/sec]), TFR - time to peak filling rate (ms), and by ECHO using pulse Doppler parameters: the peak Doppler velocities of early (E) and late diastolic flow (A), the E/A ratio, the calculated mean of the early (E´) diastolic velocity of septal and lateral mitral annulus measured by tissue Doppler imaging, and the E/E´ ratio. RESULTS: The mean PFR was 421.7 (median 371.0) % SV/sec and TPF was 198.7 ms (median 169.5), the mean E/A ratio was 1.21 (median 0.85) and the E/E´ ratio was 9.0 (median 8.40). TPF correlated significantly (inverse correlation) with the E/A ratio (r = -0.34, p = 0.030), and not significantly with E´ (r = -0.27, p = 0.082), the PFR/age ratio correlated with the E/E´ ratio (r = -0.31, p = 0.05). CONCLUSION: Significant correlations of parame-ters of diastolic function as assessed by radionuclide and Doppler studies were identified in the HF REF patients.


Assuntos
Disfunção Ventricular Esquerda/diagnóstico por imagem , Diástole/fisiologia , Ecocardiografia Doppler , Feminino , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Ventriculografia com Radionuclídeos , Volume Sistólico/fisiologia , Disfunção Ventricular Esquerda/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...