Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Gerodontology ; 32(3): 188-94, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24004379

RESUMO

OBJECTIVE AND BACKGROUND: The purpose of this study was to investigate the association of dry mouth with denture plaque microflora in patients with palatal obturator prostheses from the viewpoint of infection control. METHODS: Thirty palatal obturator prosthesis wearers were compared with 30 healthy maxillary complete denture wearers. Dry mouth was examined using a moisture-checking device and was diagnosed by the measured moisture levels. Denture plaque was collected by rubbing the mucosal surface of the denture with a swab; collected microorganisms were cultured and identified using culture-dependent methods. The number of colonising microorganisms and prevalence of microorganisms were examined according to the type of prostheses and presence of dry mouth using nonparametric tests and frequency analysis (α = 0.05). RESULTS: The prevalence of Candida spp. and Staphylococcus spp. in palatal obturator prostheses was significantly higher than that in complete dentures. In palatal obturator prostheses, the total number of colonising microorganisms showed no significant differences between the groups with and without dry mouth on each side of the prostheses. However, the prevalence of Candida spp. and Staphylococcus spp. in the group with dry mouth was significantly higher than that in the group without dry mouth. The number of microorganisms and moisture levels of palatal obturator prosthesis wearers showed a significantly negative correlation with Candida spp. and Staphylococcus spp., but a positive correlation with Neisseria spp. CONCLUSION: It was concluded that palatal obturator prosthesis wearers with a dry mouth have greater colonisation by Candida spp. and Staphylococcus spp. than do complete denture wearers.


Assuntos
Bactérias/isolamento & purificação , Candida/isolamento & purificação , Placa Dentária/microbiologia , Prótese Total/microbiologia , Boca/microbiologia , Obturadores Palatinos/microbiologia , Xerostomia , Idoso , Idoso de 80 Anos ou mais , Bactérias/classificação , Candida/classificação , Contagem de Colônia Microbiana , Estudos Transversais , Feminino , Humanos , Masculino , Técnicas Microbiológicas
2.
Implant Dent ; 23(3): 264-9, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24844386

RESUMO

OBJECTIVES: Type 2 diabetes mellitus (DM) has a deleterious effect on dental implant integration into alveolar bone, thought to arise from impaired osteoblast function and consequent reduced bone turnover. However, whether controlling blood glucose with antidiabetic drugs is sufficient to improve implant integration is unclear. This study was designed to evaluate implant integration using diabetic rats with/without an antidiabetic drug. MATERIALS AND METHODS: Titanium screws were surgically implanted in each tibia of 20 Goto-Kakizaki (GK) rats and 5 nondiabetic control rats. After 3 or 9 weeks, osseointegration was determined by testing the removal torque required to displace the screw and by histological analysis of various parameters of bone formation. RESULTS: Removal torque was significantly higher in the nondiabetic control group than in GK rats, irrespective of whether the GK rats had received voglibose. Histology revealed that single-labeled surface area was still high in the GK rats at 9 weeks but had peaked and diminished in control rats. Bone-implant contact area was reduced in GK rats. CONCLUSIONS: Despite controlling blood glucose, voglibose was unable to reverse the bone metabolic effects of DM.


Assuntos
Implantes Dentários/efeitos adversos , Diabetes Mellitus Tipo 2/complicações , Hipoglicemiantes/farmacologia , Inositol/análogos & derivados , Osteogênese/efeitos dos fármacos , Processo Alveolar/efeitos dos fármacos , Processo Alveolar/patologia , Processo Alveolar/fisiologia , Animais , Fenômenos Biomecânicos , Análise do Estresse Dentário , Modelos Animais de Doenças , Inositol/farmacologia , Masculino , Camundongos Endogâmicos , Osteogênese/fisiologia , Ratos , Ratos Wistar
3.
Gerodontology ; 31(2): 83-8, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23421873

RESUMO

OBJECTIVE: Examination of dry mouth in postoperative oral tumour patients should ideally be performed simply and quickly at the chair side. Moisture-checking devices and saliva wetness testers are available for such moisture measurement. Previous studies have reported that moisture-checking devices are useful to examine dry mouth in patients with maxillary obturator prostheses. However, because the measurement principles of saliva wetness testers differ from those of moisture-checking devices, diagnosis by the two devices may result in diagnostic disagreement. The purpose of the present study was to compare the usefulness of a saliva wetness tester with a moisture-checking device for patients with maxillary obturator prostheses. METHODS: Oral moisture was measured with a moisture-checking device and a saliva wetness tester in 30 subjects with maxillary obturator prostheses. These measurements were performed five times at the lingual mucosa, and mean values of each measurement were calculated. The reference value for moisture measurements with the moisture-checking device was 29%, and that with the saliva wetness tester was 3 mm. Subjects were classified as having dry mouth when their moisture measurements were less than the reference values. RESULTS: The diagnostic results of the saliva wetness tester were in agreement with those of the moisture-checking device. The respective moisture measurements showed a significant positive correlation (r=0.88, p<0.01). CONCLUSION: The results of the present study demonstrate that saliva wetness testers are as useful as moisture-checking devices to examine dry mouth in patients with maxillary obturator prostheses.


Assuntos
Obturadores Palatinos , Saliva/metabolismo , Xerostomia/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Capacitância Elétrica/uso terapêutico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Saliva/química , Língua/anatomia & histologia , Água/análise , Xerostomia/fisiopatologia
4.
Gerodontology ; 31(3): 202-9, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23215771

RESUMO

OBJECTIVES: To compare ultrasonic cleaning combined with immersion in a commercially available peroxide-based cleanser solution (Polident(®) ) with other denture cleaning methods, we examined the quantity of micro-organisms that survived on dentures before and after various cleaning methods. SUBJECTS AND METHODS: One hundred complete dentures belonging to 50 nursing home residents (mean age, 84.6 years) were randomly assigned to five groups according to the cleaning method employed: (A) immersion in Polident(®) solution alone, (B) brushing with water, (C) ultrasonic cleaning with water, (D) method (A) followed by method (B) and (E) ultrasonic cleaning combined with immersion in Polident(®) solution. Before and after the dentures had been cleaned, denture biofilm was collected from the mucosal surface of each lateral half of the examined dentures. The collected micro-organisms were cultured, presumptively identified by standard methods and quantified. Comparisons between the five cleaning methods were carried out using the Kruskal-Wallis test and Dunn's multiple comparisons test. RESULTS: The denture cleaning methods involving the use of Polident(®) solution (methods A, D and E) were significantly more effective at denture disinfection than the other methods (p < 0.05); in particular, the quantity of Candida spp. was lowest after method E (median, 0.00; significantly lower than those observed after methods A, B and C; p < 0.05). CONCLUSION: It was concluded that ultrasonic cleaning combined with immersion in a peroxide-based cleanser solution effectively reduces the quantity of micro-organisms surviving on dentures and is a suitable method for elderly individuals who find brushing their dentures difficult.


Assuntos
Desinfetantes de Equipamento Odontológico/uso terapêutico , Higienizadores de Dentadura/uso terapêutico , Prótese Total/microbiologia , Viabilidade Microbiana , Peróxidos/uso terapêutico , Ondas Ultrassônicas , Idoso , Idoso de 80 Anos ou mais , Biofilmes/efeitos dos fármacos , Biofilmes/efeitos da radiação , Boratos/uso terapêutico , Candida/efeitos dos fármacos , Candida/efeitos da radiação , Dispositivos para o Cuidado Bucal Domiciliar , Placa Dentária/microbiologia , Placa Dentária/terapia , Feminino , Humanos , Masculino , Viabilidade Microbiana/efeitos dos fármacos , Viabilidade Microbiana/efeitos da radiação , Pessoa de Meia-Idade , Neisseria/efeitos dos fármacos , Neisseria/efeitos da radiação , Distribuição Aleatória , Sonicação , Streptococcus/efeitos dos fármacos , Streptococcus/efeitos da radiação , Sulfatos/uso terapêutico , Água/química
5.
J Prosthodont Res ; 57(2): 113-21, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23265952

RESUMO

PURPOSE: This study aimed to examine changes in the lip form, oral fissure form and vermilion height of complete denture wearers resulting from altered occlusal vertical dimension (OVD) and/or lip support. METHODS: Three-dimensional facial images of 10 edentulous patients (four males and six females) when wearing six experimental record blocks (ExpRBs) with varying OVD and/or lip support were analyzed. Analysis was performed using three landmarks on the mid-line (labrale superius (ls), stomion (sto), and labrale inferius (li)) and two landmarks on the oral fissure (at points 20mm right and left of the midline (r-OFP and l-OFP, respectively)). Curvature of the oral fissure (COF) in the frontal view was evaluated by calculating the difference between sto and the average of r-OFP and l-OFP (avrl-OFP). The vermilion height in the frontal view was calculated as the distance from sto to ls and li. In 10 subjects, comparison between standard ExpRB and test ExpRBs with altered OVD and/or lip support was performed by calculating differences between these data. RESULTS: The ls, sto, and li landmarks changed with alteration of OVD and/or lip support, whereas avrl-OFP changed vertically with alteration of lip support and anteroposteriorly with alteration of OVD and/or lip support. COF and vermilion height were affected by alterations in OVD and/or lip support. CONCLUSION: Deficient OVD with extensive lip support can curve the oral fissure form upward, and deficient OVD with deficient lip support can reduce the vermilion height.


Assuntos
Prótese Total , Lábio/anatomia & histologia , Idoso , Idoso de 80 Anos ou mais , Humanos , Arcada Edêntula , Pessoa de Meia-Idade , Dimensão Vertical
6.
Gerodontology ; 29(2): e259-66, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21284712

RESUMO

OBJECTIVES: To investigate effective denture-cleaning methods, we examined the relationships between the quantity of microorganisms adhering to dentures and the use of a denture brush and the frequency of use of a denture cleanser. SUBJECTS AND METHODS: Denture plaque was collected from the mucosal surface of the examined dentures, which were 142 and 80 upper and lower complete dentures, respectively, worn by 96 outpatients (mean age: 71.9 years) of a university hospital and 41 nursing home residents (mean age: 84.8 years). The collected microorganisms were counted in terms of isolated representative colonies that were cultured and identified using standard methods. The use of a denture brush, the frequency of use, and the type and soaking time of denture cleansers as denture-cleaning methods were surveyed. RESULTS: The quantity of microorganisms was significantly lower in dentures of denture brush users than in those of non-users in the outpatients (p < 0.01, Mann-Whitney U test). The quantity of microorganisms was significantly lower in the dentures of outpatients who used a denture cleanser daily or 3-4 times a week than in those who used one once or less per month and in the dentures of nursing home residents who used one daily than in those who used one at other frequencies (p < 0.05, Kruskal-Wallis test, followed by Dunn's Multiple Comparison test). CONCLUSION: Within the limitations of this study, it was concluded that the use of a denture brush and daily use of denture cleanser should be recommended to complete dentures wearers as denture-cleaning methods that effectively reduce the quantity of microorganisms adhering to dentures.


Assuntos
Aderência Bacteriana , Placa Dentária/microbiologia , Higienizadores de Dentadura/uso terapêutico , Prótese Total/microbiologia , Escovação Dentária/instrumentação , Idoso , Idoso de 80 Anos ou mais , Bactérias/classificação , Carga Bacteriana , Técnicas Bacteriológicas , Boratos/uso terapêutico , Candida/isolamento & purificação , Placa Dentária/terapia , Bases de Dentadura/microbiologia , Prótese Total Inferior/microbiologia , Prótese Total Superior/microbiologia , Feminino , Humanos , Masculino , Neisseria/isolamento & purificação , Casas de Saúde , Higiene Bucal/instrumentação , Higiene Bucal/métodos , Pacientes Ambulatoriais , Fatores Sexuais , Streptococcus/isolamento & purificação , Sulfatos/uso terapêutico , Fatores de Tempo
7.
Dent Mater J ; 30(5): 626-34, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21946482

RESUMO

The purpose of this study was to design an optimum glass fiber-reinforced composite (FRC) clasp. Three-dimensional finite element models were constructed of FRC circumferential clasp arms and an abutment tooth. The basic clasp arm was half-oval, without a taper, 2.60 mm wide and 1.30 mm thick. Four modified clasp arms were prepared by changing the width or thickness of the basic clasp (width/thickness: 2.60 mm/0.65 mm, 2.60 mm/1.95 mm, 1.30 mm/1.30 mm, and 3.90 mm/1.30 mm). Forced displacements of 5 mm in the removal direction were applied to the nodes at the base of the clasp arm. The retentive forces and maximum tensile stresses of the five FRC clasp arms ranged from 1.00-16.30 N and from 58.9-151 MPa, respectively. Results showed that an optimum FRC clasp was a circumferential clasp with 2.60 mm width and 1.30 mm thickness, which had sufficient retentive force and low risk of tensile failure.


Assuntos
Resinas Compostas/química , Grampos Dentários , Materiais Dentários/química , Planejamento de Prótese Dentária , Análise de Elementos Finitos , Vidro/química , Dinâmica não Linear , Simulação por Computador , Dente Suporte , Retenção em Prótese Dentária , Falha de Restauração Dentária , Módulo de Elasticidade , Previsões , Humanos , Imageamento Tridimensional/métodos , Modelos Biológicos , Maleabilidade , Estresse Mecânico , Propriedades de Superfície
8.
J Prosthodont Res ; 54(2): 65-9, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20083449

RESUMO

PURPOSE: This study aimed to examine the relationship between symptoms of dry mouth and the moisture levels in patients with maxillofacial prostheses. METHODS: Dry mouth of 30 patients with maxillofacial prostheses was examined by direct measurement of oral moisture and subjective symptoms of dry mouth were surveyed using Kakinoki's questionnaire. Oral moisture was measured five times at each of the lingual mucosa and the right and left buccal mucosa using Moisture Checker Mucus and the mean value was calculated. Using a value of 29% as a reference, patients were classified as normal when the moisture value was 29%, or more, or with dry mouth if the value was when less than 29%. RESULTS: The moisture levels of the patients with subjective symptoms of dry mouth were significantly lower than those of the patients without symptoms of dry mouth at each of the lingual and buccal mucosa. The moisture level of the lingual mucosa was significantly lower than that of buccal mucosa in the group reporting subjective symptoms of dry mouth, but not in those without symptoms. CONCLUSION: These results suggest that the symptom of dry mouth is corresponding to the moisture level and the moisture level of the lingual mucosa is associated with symptoms of dryness in patients with maxillofacial prosthesis.


Assuntos
Prótese Maxilofacial , Água/análise , Xerostomia/diagnóstico , Idoso , Feminino , Humanos , Masculino
9.
J Prosthodont Res ; 54(1): 14-23, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19818701

RESUMO

PURPOSE: This study aimed to clarify the role of the artificial tooth arch (ATA) during swallowing in edentates. METHODS: The tongue pressures, activities of the masseter and suprahyoid muscles, and laryngeal and mandibular movements when swallowing saliva, water, pudding, and corned beef were measured simultaneously using experimental dentures with and without an ATA. We analysed the maximum magnitudes of muscle activities and tongue pressures (MAmax and TPmax, respectively), the times from reaching MAmax and TPmax to laryngeal movement (TLM-MAmax and TLM-TPmax, respectively), and the vertical mandibular position. RESULTS: The MAmax of the masseter muscle and TPmax were significantly greater with the ATA than without the ATA (p<0.05). However, MAmax of the suprahyoid muscles was not significantly different in the conditions with and without the ATA. TLM-TPmax was significantly longer without the ATA than with the ATA (p<0.05) but the TLM-MAmax of the suprahyoid and masseter muscles were not significantly different with and without the ATA. The MAmax of both suprahyoid and masseter muscles and the TPmax were significantly greater, and TLM-TPmax was significantly longer when swallowing corned beef than other materials (p<0.05). The intermaxillar distance and the range of measured mandibular position at the time of swallowing were shorter and wider in the absence of the ATA than with it. CONCLUSION: The present study shows that during swallowing the ATA supports the function of the tongue to perform skillful movements for the smooth passage of food to the oropharynx and the elevation of the larynx by maintaining the mandible position constant near the intercuspal position.


Assuntos
Deglutição/fisiologia , Prótese Total , Boca Edêntula/fisiopatologia , Dente Artificial , Idoso , Feminino , Humanos , Laringe/fisiologia , Masculino , Mandíbula/fisiologia , Músculo Masseter/fisiologia , Mastigação/fisiologia , Pessoa de Meia-Idade , Movimento/fisiologia , Orofaringe/fisiologia , Língua/fisiologia
10.
J Cell Physiol ; 221(3): 740-9, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19725053

RESUMO

Osteoblasts, originating from mesenchymal stem cells, play a pivotal role in bone formation and mineralization. Several transcription factors including runt-related transcription factor 2 (Runx2) have been reported to be essential for osteoblast differentiation, whereas the cytoplasmic signal transduction pathways controlling the differentiation process have not been fully elucidated. AMP-activated protein kinase (AMPK) is a serine-threonine kinase generally regarded as a key regulator of cellular energy homeostasis, polarity, and division. Recent lines of evidence have indicated that the activity of the catalytic alpha subunit of AMPK is regulated through its phosphorylation by upstream AMPK kinases (AMPKKs) including LKB1. Here, we explored the role of AMPK in osteoblast differentiation using in vitro culture models. Phosphorylation of AMPKalpha was significantly decreased during osteoblastic differentiation in both primary osteoblasts and MC3T3-E1, a mouse osteoblastic cell line. Conversely, the terminal differentiation of primary osteoblasts and MC3T3-E1 cells, represented by matrix mineralization, was significantly inhibited by glucose restriction and stimulation with metformin, both of which are known activators of AMPK. Matrix mineralization of MC3T3-E1 cells was also inhibited by the forced expression of a constitutively active form of AMPKalpha. Metformin significantly inhibited gene expression of Runx2 along with osteoblast differentiation markers including osteocalcin (Ocn), bone sialo protein (Bsp), and osteopontin (Opn). Thus, our present data indicate that differentiation of osteoblasts is functionally associated with decreased AMPK activity.


Assuntos
Proteínas Quinases Ativadas por AMP/metabolismo , Diferenciação Celular/fisiologia , Osteoblastos/citologia , Células 3T3-L1 , Proteínas Quinases Ativadas por AMP/genética , Adipócitos/citologia , Fosfatase Alcalina/metabolismo , Aminoimidazol Carboxamida/análogos & derivados , Aminoimidazol Carboxamida/farmacologia , Animais , Calcificação Fisiológica/efeitos dos fármacos , Diferenciação Celular/efeitos dos fármacos , Linhagem Celular , Sobrevivência Celular/efeitos dos fármacos , Células Cultivadas , Subunidade alfa 1 de Fator de Ligação ao Core/genética , Expressão Gênica/efeitos dos fármacos , Expressão Gênica/genética , Glucose/deficiência , Glucose/farmacologia , Hipoglicemiantes/farmacologia , Sialoproteína de Ligação à Integrina , Metformina/farmacologia , Camundongos , Camundongos Endogâmicos C57BL , Osteoblastos/metabolismo , Osteocalcina/genética , Osteopontina/genética , Fosforilação/efeitos dos fármacos , Ribonucleotídeos/farmacologia , Sialoglicoproteínas/genética , Transfecção
11.
Dent Mater J ; 28(3): 307-14, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19662730

RESUMO

The bactericidal efficacy of 1.00-4.50% glycine-type amphoteric surfactant (Gly) was evaluated by measuring its microorganism removal rate in denture plaque. Physical and mechanical properties such as surface roughness, color difference, and bending strength of two different denture base resins were determined before and after cleaning in Gly solutions, a commercial denture cleaner, and tap water. The microorganism removal rates of all the Gly solutions were higher than those of a commercial enzymatic denture cleaner (Polident) (p>0.05). The removal rate of Candida spp. by Polident was not significantly different from the removal rate using water. Changes in the surface roughness and color difference among the specimens were slight. There were no significant differences in the bending strengths of the two resins for all concentrations of Gly solution (p>0.05). These results suggested that glycine-type amphoteric surfactant solution may be effective as a denture cleaner in conjunction with an ultrasonic cleaning device.


Assuntos
Antibacterianos/farmacologia , Materiais Dentários/química , Bases de Dentadura , Higienizadores de Dentadura/farmacologia , Glicina/farmacologia , Metilmetacrilatos/química , Tensoativos/farmacologia , Antibacterianos/química , Bactérias/efeitos dos fármacos , Boratos/química , Boratos/farmacologia , Candida/efeitos dos fármacos , Contagem de Colônia Microbiana , Cor , Higienizadores de Dentadura/química , Prótese Total , Glicina/química , Humanos , Teste de Materiais , Metacrilatos/química , Metilmetacrilato/química , Microscopia Eletrônica de Varredura , Maleabilidade , Polimetil Metacrilato/química , Sulfatos/química , Sulfatos/farmacologia , Propriedades de Superfície , Tensoativos/química , Ultrassom , Água/química
12.
J Prosthodont ; 18(4): 359-62, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19486454

RESUMO

Tooth loss accompanied by a massive defect of the alveolar bone can cause serious problems such as food deposit and esthetic impairment. This report describes procedures for the fabrication of an osseous defect obturator prosthesis connected to a fixed partial denture by a magnetic attachment along with the clinical outcome.


Assuntos
Planejamento de Dentadura , Prótese Parcial Fixa , Magnetismo/instrumentação , Prótese Periodontal , Resinas Acrílicas , Processo Alveolar/patologia , Dente Canino/cirurgia , Materiais Dentários , Seguimentos , Humanos , Masculino , Doenças Maxilares/cirurgia , Pessoa de Meia-Idade , Cisto Radicular/cirurgia , Propriedades de Superfície , Extração Dentária , Alvéolo Dental/patologia , Resultado do Tratamento
13.
J Prosthodont Res ; 53(2): 67-71, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19318075

RESUMO

PURPOSE: This study aimed to examine the relationship between oral dryness and medical treatment (medication, radiotherapy) for patients with maxillofacial prostheses. METHODS: Sixteen patients with maxillofacial prostheses were examined according to the following procedure. For evaluating oral dryness, oral moisture was measured at the lingual mucosa and the right and left buccal mucosa using a Moisture Checker Mucus. The mean value of each measurement was recorded as the moisture value (%). A value of 29% was used as a reference value to divide patients into a normal group and an oral dryness group. Patients with a moisture value of more than 29% were classified as normal. The clinical histories of the patients (including their current medication use and radiotherapy history-dose of radiation and period after radiation) were surveyed from their clinical records. Patients rated themselves on their feelings for oral dryness using a faces scale. RESULTS: The moisture value was significantly lower in the oral dryness group than the normal group. There was a significant difference in moisture values between the number of patients with and without radiotherapy, but not patients with and without medications. The moisture value had a significant negative correlation with the dose of radiation and a positive one with the period after radiation. The score of faces scale showed a significant negative correlation with moisture value. CONCLUSION: The patients with maxillofacial prostheses who had undergone radiotherapy need moisture retention because of oral dryness depending on the dose of radiation and the period after radiation.


Assuntos
Técnicas Biossensoriais/instrumentação , Prótese Maxilofacial/efeitos adversos , Mucosa Bucal/metabolismo , Radioterapia/efeitos adversos , Saliva/metabolismo , Xerostomia/diagnóstico , Xerostomia/etiologia , Idoso , Feminino , Humanos , Masculino , Neoplasias Maxilares , Pessoa de Meia-Idade , Dosagem Radioterapêutica
14.
Dent Mater J ; 26(4): 534-44, 2007 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-17886458

RESUMO

The purpose of this study was to investigate the effects of different cross-sectional shapes and presence of taper on stress distribution in clasp arms made of glass fiber-reinforced composite (FRC) material. Stress analysis of clasps was performed under a constant load (5 N) using a three-dimensional finite element method with due consideration to the anisotropy of unidirectional FRC material. Results were then compared with clasp arms made of metal- an isotropic material. It was found that both FRC clasps and metal clasps yielded similar results. As for the displacement of clasp arms with a basic cross-sectional shape under a load of 5 N, the amount of displacement showed that FRC clasps provided sufficient retentive force required for clinical application.


Assuntos
Resinas Acrílicas/química , Resinas Compostas/química , Grampos Dentários , Planejamento de Prótese Dentária/métodos , Análise do Estresse Dentário/métodos , Poliuretanos/química , Ligas Dentárias/química , Análise de Elementos Finitos
15.
Dent Mater J ; 26(3): 429-36, 2007 May.
Artigo em Inglês | MEDLINE | ID: mdl-17695076

RESUMO

The aim of this study was to develop a three-dimensional method to analyze edentulous ridge shapes. A laser projection method was used to record the shape of edentulous plaster models. Contour of residual ridge on the reconstructed image was then subdivided into small triangles, and a 'normal line' representing the center of gravity of each triangle was determined buccolingually and anteroposteriorly. Angle between the normal line on the residual ridge and the tentative occlusal plane was calculated for each triangle. These angles were then used to analyze the ridge shape. This method was used to analyze the ridges of 20 edentulous patients with excessive bone resorption. The results suggested that this method was useful for analyzing edentulous ridges regardless of ridge shape and degree of resorption.


Assuntos
Processo Alveolar/patologia , Arcada Edêntula/patologia , Lasers , Modelos Dentários , Software , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Mandíbula/patologia , Pessoa de Meia-Idade
16.
Dent Mater J ; 23(4): 528-32, 2004 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-15688715

RESUMO

The aim of this study was to investigate the effects of water immersion and repeated loading on the mechanical properties of a glass fiber-reinforced composite (FRC) material. Measurements for three-point flexural tests were made at three different temperatures and cross-head speeds, while measurements for fatigue tests were made under three different loads in air or water at 37 degrees C after each cycle. The flexural strength and elastic modulus of the immersed specimens were significantly lower than those of the dry specimens at the same cross-head speed and temperature. On the whole, the values were inferior to those of metal. The deflection increased significantly as the load increased, but there were no significant differences between the values of dry and immersed specimens. With increasing load and number of cycles, the permanent deformation of both specimens increased significantly. The permanent deformation was similar to that of Co-Cr alloy. Based on the results of this study, it is recommended that more effort be devoted to exploring and devising shapes that would render FRC clasp arms with mechanical and physical properties that differ favorably from those of metal.


Assuntos
Resinas Compostas/química , Grampos Dentários , Análise de Variância , Análise do Estresse Dentário , Elasticidade , Vidro , Imersão , Teste de Materiais , Maleabilidade , Estatísticas não Paramétricas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...