Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Br J Radiol ; 97(1158): 1162-1168, 2024 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-38648776

RESUMO

OBJECTIVES: A portable respiratory training system with a gyroscope sensor (gyroscope respiratory training system [GRTS]) was developed and the feasibility of respiratory training was evaluated. METHODS: Simulated respiratory waveforms from a respiratory motion phantom and actual respirator waveforms from volunteers were acquired using the GRTS and Respiratory Gating for Scanners system (RGSC). Respiratory training was evaluated by comparing the stability and reproducibility of respiratory waveforms from patients undergoing expiratory breath-hold radiation therapy, with and without the GRTS. The stability and reproducibility of respiratory waveforms were assessed by root mean square error and gold marker placement-based success rate of expiratory breath-hold, respectively. RESULTS: The absolute mean difference for sinusoidal waveforms between the GRTS and RGSC was 2.0%. Among volunteers, the mean percentages of errors within ±15% of the respiratory waveforms acquired by the GRTS and RGSC were 96.1% for free breathing and 88.2% for expiratory breath-hold. The mean root mean square error and success rate of expiratory breath-hold (standard deviation) with and without the GRTS were 0.65 (0.24) and 0.88 (0.89) cm and 91.0% (6.9) and 89.1% (11.6), respectively. CONCLUSIONS: Respiratory waveforms acquired by the GRTS exhibit good agreement with waveforms acquired by the RGSC. Respiratory training with the GRTS reduces inter-patient variability in respiratory waveforms, thereby improving the success of expiratory breath-hold radiation therapy. ADVANCES IN KNOWLEDGE: A respiratory training system with a gyroscope sensor is inexpensive and portable, making it ideal for respiratory training. This is the first report concerning clinical implementation of a respiratory training system.


Assuntos
Estudos de Viabilidade , Humanos , Reprodutibilidade dos Testes , Masculino , Adulto , Imagens de Fantasmas , Feminino , Suspensão da Respiração , Exercícios Respiratórios/instrumentação , Exercícios Respiratórios/métodos , Pessoa de Meia-Idade , Respiração , Desenho de Equipamento
2.
Radiol Phys Technol ; 14(4): 381-389, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34716568

RESUMO

The evaluation of the entrance surface dose (ESD) ensures safe radiation doses for X-ray imaging patients. The air kerma free-in-air value used to estimate ESD may be affected by those X-rays that scatter from the scatterer placed behind the chamber at the time of measurement, thereby leading to assessment errors. Therefore, the influence of scattered radiation on air kerma measurements was investigated. Monte Carlo simulations were performed for various detector-to-scatterer distances and scatterer materials. The simulation results were compared with actual measurements to confirm the simulation accuracy. The source-chamber distance was set to 50 and 100 cm for the experimental measurements and simulation, respectively, and the chamber-scatterer distance was varied. The Monte Carlo simulation results reproduced the actual measurements with an accuracy of 3.5%. The effect of backscattering varied with the tube voltage and irradiation field size. The effect was observed in the order of prominence for the following scatterer materials: water-equivalent phantom, acrylic, concrete, lead, and iron. Furthermore, this effect decreased exponentially with increasing chamber-scatterer distance. For a field size of 10 × 10 cm2, the finite-distance backscatter factor decreased with an increasing chamber-scatterer distance for all materials. The cause of backscattering in diagnostic X-ray energy regions differs depending on the scatterer material, as well as the photon energy and field size. Backscattering decreases exponentially as the distance between the detector and scatterer increases.


Assuntos
Fótons , Radiometria , Humanos , Método de Monte Carlo , Imagens de Fantasmas , Radiografia , Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...