Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 138
Filtrar
1.
JAMA Intern Med ; 2024 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-38683588

RESUMO

This case report describes a man in his 80s who received shock from an automated external defibrillator that registered 3 types of tachycardia.

4.
Aging Cell ; 23(2): e14041, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37985931

RESUMO

Mechanical perturbation triggers activation of resident myogenic stem cells to enter the cell cycle through a cascade of events including hepatocyte growth factor (HGF) release from its extracellular tethering and the subsequent presentation to signaling-receptor c-met. Here, we show that with aging, extracellular HGF undergoes tyrosine-residue (Y) nitration and loses c-met binding, thereby disturbing muscle homeostasis. Biochemical studies demonstrated that nitration/dysfunction is specific to HGF among other major growth factors and is characterized by its locations at Y198 and Y250 in c-met-binding domains. Direct-immunofluorescence microscopy of lower hind limb muscles from three age groups of rat, provided direct in vivo evidence for age-related increases in nitration of ECM-bound HGF, preferentially stained for anti-nitrated Y198 and Y250-HGF mAbs (raised in-house) in fast IIa and IIx myofibers. Overall, findings highlight inhibitory impacts of HGF nitration on myogenic stem cell dynamics, pioneering a cogent discussion for better understanding age-related muscle atrophy and impaired regeneration with fibrosis (including sarcopenia and frailty).


Assuntos
Músculos , Transdução de Sinais , Animais , Ratos , Diferenciação Celular/fisiologia , Divisão Celular , Células-Tronco
5.
J Electrocardiol ; 82: 118-124, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38128156

RESUMO

BACKGROUND: Complete atrioventricular block (C-AVB) following internal electrical cardioversion (IEC) during atrial fibrillation (AF) ablation has not been fully investigated. We aimed to determine the prevalence and predictors of C-AVB following IEC during AF ablation. METHODS: C-AVB (non-conducted sinus impulse after IEC) and ventricular pause (VP) (the interval between IEC and the QRS complex) following the first attempt of IEC, and baseline electrocardiographic parameters were investigated in patients who underwent first-time AF ablation. RESULTS: We investigated the first attempt of IEC in 124 patients (mean age:70 ± 11 years, 81 men, 99 non-paroxysmal AF). AF was terminated in 109/124 (88%) patients, with a VP of 1590 [1014-2208] (maximum, 8780) ms. Transient C-AVB following IEC occurred in 14/109 (13%) patients. The VP was longer in patients with transient C-AVB than in those without transient C-AVB (2418 [1693-4425] vs. 1530 [876-2083] ms, p = 0.002). In multivariate analysis, the left atrial diameter (Odds ratio [OR]:1.21; 95% confidence interval (95%CI):1.06-1.39; p = 0.005) and preexisting intraventricular conduction abnormality (OR:9.22; 95%CI:1.60-53.3; p = 0.013) were predictors of transient C-AVB following IEC. CONCLUSION: Left atrial diameter and preexisting intraventricular conduction abnormalities were predictors of transient C-AVB following IEC during AF ablation.


Assuntos
Fibrilação Atrial , Bloqueio Atrioventricular , Ablação por Cateter , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/cirurgia , Bloqueio Atrioventricular/terapia , Cardioversão Elétrica , Eletrocardiografia , Átrios do Coração , Resultado do Tratamento
6.
Circ Arrhythm Electrophysiol ; 16(10): e012241, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37728002

RESUMO

BACKGROUND: Abnormal atrial potentials (AAPs) recorded during sinus rhythm/atrial pacing may indicate areas of slow conduction capable of supporting reentrant atrial tachycardia (AT). Therefore, we sought to examine the relationship between AAPs and AT circuits. METHODS: One hundred twenty-three reentrant ATs in 104 patients were analyzed. AAPs, consisting of fragmented potentials and split potentials, were assessed using the Rhythmia LUMIPOINT algorithm. RESULTS: There was 93±13% overlap between areas with AAPs during sinus rhythm/atrial pacing and areas of slow conduction along the reentry circuit during AT. The cumulative area of AAPs was smaller in patients with localized-reentrant ATs compared with anatomic macro-reentrant ATs (20.0 [14.6-30.5] versus 28.9 [21.8-35.6] cm2; P=0.021). Patients with perimitral ATs had larger areas of AAPs on the lateral wall whereas patients with roof-dependent ATs had larger areas of AAPs on the roof and posterior wall (P≤0.018 for all comparisons). The patchy scar that was associated with localized-reentrant AT exhibited a larger area of AAPs at its periphery than the scar that did not participate in localized-reentrant AT (3.1 [2.4-4.5] versus 1.0 [0.7-1.6] cm2; P<0.001). CONCLUSIONS: AAPs recorded during sinus rhythm/atrial pacing are associated with areas of slow conduction during reentrant AT. The burden and distribution of AAPs may provide actionable insights into AT circuit features, including in cases in which ATs are difficult to map.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Cicatriz , Átrios do Coração , Frequência Cardíaca , Estimulação Cardíaca Artificial
7.
JACC Clin Electrophysiol ; 9(10): 2054-2066, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37715740

RESUMO

BACKGROUND: Substrate abnormalities can alter atrial activation during atrial tachycardias (ATs) thereby influencing AT-wave morphology on the surface electrocardiogram. OBJECTIVES: This study sought to identify determinants of isoelectric intervals during ATs with complex atrial activation patterns. METHODS: High-density activation maps of 126 ATs were studied. To assess the impact of the activated atrial surface on the presence of isoelectric intervals, this study measured the minimum activated area throughout the AT cycle, defined as the smallest activated area within a 50-millisecond period, by using signal processing algorithms (LUMIPOINT). RESULTS: ATs with isoelectric intervals (P-wave ATs) included 23 macro-re-entrant ATs (40%), 26 localized-re-entrant ATs (46%), and 8 focal ATs (14%), whereas those without included 46 macro-re-entrant ATs (67%), 21 localized-re-entrant ATs (30%), and 2 focal ATs (3%). Multivariable regression identified smaller minimum activated area and larger very low voltage area as independent predictors of P-wave ATs (OR: 0.732; 95% CI: 0.644-0.831; P < 0.001; and OR: 1.042; 95% CI: 1.006-1.080; P = 0.023, respectively). The minimum activated area with the cutoff value of 10 cm2 provided the highest predictive accuracy for P-wave ATs with sensitivity, specificity, and positive and negative predictive values of 96%, 97%, 97%, and 95%, respectively. In re-entrant ATs, smaller minimum activated area was associated with lower minimum conduction velocity within the circuit and fewer areas of delayed conduction outside of the circuit (standardized ß: 0.524; 95% CI: 0.373-0.675; P < 0.001; and standardized ß: 0.353; 95% CI: 0.198-0.508; P < 0.001, respectively). CONCLUSIONS: Reduced atrial activation area and voltage were associated with isoelectric intervals during ATs.


Assuntos
Ablação por Cateter , Taquicardia Supraventricular , Taquicardia Ventricular , Humanos , Técnicas Eletrofisiológicas Cardíacas , Frequência Cardíaca , Eletrocardiografia
8.
Heart Rhythm O2 ; 4(2): 134-146, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36873315

RESUMO

In the setting of structural heart disease, ventricular tachycardia (VT) is typically associated with a re-entrant mechanism. In patients with hemodynamically tolerated VTs, activation and entrainment mapping remain the gold standard for the identification of the critical parts of the circuit. However, this is rarely accomplished, as most VTs are not hemodynamically tolerated to permit mapping during tachycardia. Other limitations include noninducibility of arrhythmia or nonsustained VT. This has led to the development of substrate mapping techniques during sinus rhythm, eliminating the need for prolonged periods of mapping during tachycardia. Recurrence rates following VT ablation are high; therefore, new mapping techniques for substrate characterization are required. Advances in catheter technology and especially multielectrode mapping of abnormal electrograms has increased the ability to identify the mechanism of scar-related VT. Several substrate-guided approaches have been developed to overcome this, including scar homogenization and late potential mapping. Dynamic substrate changes are mainly identified within regions of myocardial scar and can be identified as local abnormal ventricular activities. Furthermore, mapping strategies incorporating ventricular extrastimulation, including from different directions and coupling intervals, have been shown to increase the accuracy of substrate mapping. The implementation of extrastimulus substrate mapping and automated annotation require less extensive ablation and would make VT ablation procedures less cumbersome and accessible to more patients.

10.
Pacing Clin Electrophysiol ; 46(2): 144-151, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36527191

RESUMO

INTRODUCTION: Unidirectional block, left atrium to pulmonary vein (LA-PV) entrance block without PV-LA exit block, has not been fully investigated in the setting of ablation index (AI)-guided pulmonary vein (PV) isolation (PVI). The aim of this study was to investigate unidirectional blocks during AI-guided PVI. METHODS: After achieving entrance block, exit block was evaluated by pacing from the catheter placed in the PV. Local PV musculature capture without conduction to the LA was necessary to prove exit block. RESULTS: In total, 441 PVs (including nine left common PVs) from 113 consecutive patients (mean age: 71 ± 12 years, 77 men, 61 paroxysmal atrial fibrillation cases) who underwent initial AI-guided PVI for atrial fibrillation were studied. Entrance block was achieved in all PVs. of the 247/441 (56%) PVs showing local PV musculature capture, 5/247 (2.0%) showed unidirectional blocks. Three of the five PVs (left superior and inferior PVs in one patient; right superior PV in another patient) showed LA-PV reconnection, requiring additional ablation to achieve bidirectional block during the procedure. Two of the five PVs (left superior and inferior PVs in one patient) showed LA-PV reconnection, and thereafter, LA-PV conduction became blocked again spontaneously, leading to bidirectional block without further ablation during the procedure. CONCLUSION: AI-guided PVI presented a low prevalence of unidirectional block (2%), using entrance block alone as the endpoint of PVI could therefore be justified.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Veias Pulmonares/cirurgia , Átrios do Coração , Frequência Cardíaca , Ablação por Cateter/métodos , Resultado do Tratamento , Recidiva
11.
Heart Rhythm ; 20(3): 430-437, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36368515

RESUMO

BACKGROUND: Bipolar voltage is widely used to characterize the atrial substrate but has been poorly validated, particularly during clinical tachycardias. OBJECTIVE: The purpose of this study was to evaluate the diagnostic performance of voltage thresholds for identifying regions of slow conduction during reentrant atrial tachycardias (ATs). METHODS: Thirty bipolar voltage and activation maps created during reentrant ATs were analyzed to (1) examine the relationship between voltage amplitude and conduction velocity (CV), (2) measure the diagnostic ability of voltage thresholds to predict CV, and (3) identify determinants of AT circuit dimensions. Voltage amplitude was categorized as "normal" (>0.50 mV), "abnormal" (0.05-0.50 mV), or "scar" (<0.05 mV); slow conduction was defined as <30 cm/s. RESULTS: A total of 266,457 corresponding voltage and CV data points were included for analysis. Voltage and CV were moderately correlated (r = 0.407; P < .001). Bipolar voltage predicted regions of slow conduction with an area under the receiver operating characteristic curve of 0.733 (95% confidence interval 0.731-0.735). A threshold of 0.50 mV had 91% sensitivity and 35% specificity for identifying slow conduction, whereas 0.05 mV had 36% sensitivity and 87% specificity, with an optimal voltage threshold of 0.15 mV. Analyses restricted to the AT circuits identified weaker associations between voltage and CV and an optimal voltage threshold of 0.25 mV. CONCLUSION: Widely used bipolar voltage amplitude thresholds to define "abnormal" and "scar" tissue in the atria are, respectively, sensitive and specific for identifying regions of slow conduction during reentrant ATs. However, overall, the association of voltage with CV is modest. No clinical predictors of AT circuit dimensions were identified.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Taquicardia Ventricular , Humanos , Ablação por Cateter/métodos , Átrios do Coração , Frequência Cardíaca/fisiologia , Cicatriz
12.
J Electrocardiol ; 74: 134-136, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36215744

RESUMO

We describe atrial activation sequence changes during ventricular overdrive pacing in a patient with a concealed left-sided accessory pathway and discuss its potential mechanism.


Assuntos
Fibrilação Atrial , Humanos , Eletrocardiografia
14.
J Electrocardiol ; 73: 59-61, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35667213

RESUMO

We described a type 1 Brugada electrocardiogram and discussed about the potential diagnostic electrocardiographic indicators to differentiate true Brugada syndrome and Brugada phenocopy.


Assuntos
Síndrome de Brugada , Síndrome de Brugada/diagnóstico , Eletrocardiografia , Humanos , Fenótipo
15.
Biochem Biophys Rep ; 31: 101295, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35721345

RESUMO

Protein tyrosine residue (Y) nitration, a post-translational chemical-modification mode, has been associated with changes in protein activity and function; hence the accumulation of specific nitrated proteins in tissues may be used to monitor the onset and progression of pathological disorders. To verify the possible impact of nitration on postnatal muscle growth and regeneration, a pilot study was designed to examine the nitration/dysfunction of hepatocyte growth factor (HGF), a key ligand that is released from the extracellular tethering and activates myogenic stem satellite cells to enter the cell cycle upon muscle stretch and injury. Exposure of recombinant HGF (a hetero-dimer of α- and ß-chains) to peroxynitrite induces Y nitration in HGF α-chain under physiological conditions. Physiological significance of this finding was emphasized by Western blotting that showed the NK1 segment of HGF (including a K1 domain critical for signaling-receptor c-met binding) undergoes nitration with a primary target of Y198. Peroxynitrite treatment abolished HGF-agonistic activity of the NK1 segment, as revealed by in vitro c-met binding and bromodeoxyuridine-incorporation assays. Importantly, direct-immunofluorescence microscopy of rat lower hind-limb muscles from two aged-groups (2-month-old "young" and 12-month-old "retired/adult") provided in vivo evidence for age-related nitration of extracellular HGF (Y198). Overall, findings provide the insight that HGF/NK1 nitration/dysfunction perturbs myogenic stem cell dynamics and homeostasis; hence NK1 nitration may stimulate progression of muscular disorders and diseases including sarcopenia.

16.
J Cardiovasc Electrophysiol ; 33(8): 1687-1693, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35637606

RESUMO

INTRODUCTION: Systematic and quantitative descriptions of vein of Marshall (VOM)-induced tissue ablation are lacking. We sought to characterize the distribution of low voltage observed in the left atrium (LA) after VOM ethanol infusion. METHODS AND RESULTS: The distribution of ethanol-induced low voltage was evaluated by comparing high-density maps performed before and after VOM ethanol infusion in 114 patients referred for atrial fibrillation ablation. The two most frequently impacted segments were the inferior portion of the ridge (82.5%) and the first half of the mitral isthmus (pulmonary vein side) (92.1%). Low-voltage absence in these typical areas resulted from inadvertent ethanol infusion in the left atrial appendage vein (n = 3), initial VOM dissection (n = 3), or a "no branches" VOM morphology (n = 1). Visible anastomosis of the VOM with roof or posterior veins more frequently resulted in low-voltage extension beyond typical areas, toward the entire left antrum (19.0% vs. 1.9%, p = .0045) or the posterior LA (39.7% vs. 3.8%, p < .001) but with a limited positive predictive value ranging from 29.4% to 43.5%. Ethanol-induced low voltage covered a median LA surface of 3.6% (1.9%-5.0%) and did not exceed 8% of the LA surface in 90% of patients. CONCLUSION: VOM ethanol infusion typically locates at the inferior ridge and the adjacent half of the mitral isthmus. Low-voltage extensions can be anticipated but not guaranteed by the presence of visible anastomosis of the VOM with roof or posterior veins.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Etanol/efeitos adversos , Átrios do Coração/cirurgia , Humanos , Veias Pulmonares/cirurgia
17.
J Cardiovasc Electrophysiol ; 33(5): 908-916, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35274776

RESUMO

INTRODUCTION: Due to changes in esophageal position, preoperative assessment of the esophageal location may not mitigate the risk of esophageal injury in catheter ablation for atrial fibrillation (AF). This study aimed to assess esophageal motion and its impact on AF ablation strategies. METHODS AND RESULTS: Ninety-seven AF patients underwent two computed tomography (CT) scans. The area at risk of esophageal injury (AAR) was defined as the left atrial surface ≤3 mm from the esophagus. On CT1, ablation lines were drawn blinded to the esophageal location to create three ablation sets: individual pulmonary vein isolation (PVI), wide antral circumferential ablation (WACA), and WACA with linear ablation (WACA + L). Thereafter, ablation lines for WACA and WACA + L were personalized to avoid the AAR. Rigid registration was performed to align CT1 onto CT2, and the relationship between ablation lines and the AAR on CT2 was analyzed. The esophagus moved by 3.6 [2.7 to 5.5] mm. The AAR on CT2 was 8.6 ± 3.3 cm2 , with 77% overlapping that on CT1. High body mass index was associated with the AAR mismatch (standardized ß 0.382, p < .001). Without personalization, AARs on ablation lines for individual PVI, WACA, and WACA + L were 0 [0-0.4], 0.8 [0.5-1.2], and 1.7 [1.2-2.0] cm2 . Despite the esophageal position change, the personalization of ablation lines for WACA and WACA + L reduced the AAR on lines to 0 [0-0.5] and 0.7 [0.3-1.0] cm2 (p < .001 for both). CONCLUSION: The personalization of ablation lines based on a preoperative CT reduced ablation to the AAR despite changes in esophageal position.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Esôfago/lesões , Humanos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Resultado do Tratamento
18.
J Cardiovasc Electrophysiol ; 33(6): 1116-1124, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35347799

RESUMO

INTRODUCTION: The optimal strategy after a failed ablation for persistent atrial fibrillation (perAF) is unknown. This study evaluated the value of an anatomically guided strategy using a systematic set of linear lesions with adjunctive ethanol infusion into the vein of Marshall (Et-VOM) in patients referred for second perAF ablation procedures. METHODS AND RESULTS: Patients with perAF who underwent a second procedure were grouped according to the two strategies. The first strategy was an anatomically guided approach using systematic linear ablation with adjunctive Et-VOM, with bidirectional blocks at the posterior mitral isthmus (MI), roof, and cavotricuspid isthmus (CTI) as the procedural endpoint (Group I). The second one was an electrophysiology-guided strategy, with atrial tachyarrhythmia termination as the procedural endpoint (Group II). Arrhythmia behavior during the procedure guided the ablation strategy. Groups I and II consisted of 96 patients (65 ± 9 years; 71 men) and 102 patients (63 ± 10 years; 83 men), respectively. Baseline characteristics were comparable. In Group I, Et-VOM was successfully performed in 91/96 (95%), and procedural endpoint (bidirectional block across all three anatomical lines) was achieved in 89/96 (93%). In Group II, procedural endpoint (atrial tachyarrhythmia termination) was achieved in 80/102 (78%). One-year follow-up demonstrated Group I (21/96 [22%]) experienced less recurrence compared to Group II (38/102 [37%], Log-rank p = .01). This was driven by lower AT recurrence in Group I (Group I: 10/96 [10%] vs. Group II: 29/102 [28%]; p = .002). CONCLUSION: Anatomically guided strategy with adjunctive Et-VOM is superior to an electrophysiology-guided strategy for second procedures in patients with perAF at 1-year follow-up.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Eletrofisiologia Cardíaca , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Etanol/efeitos adversos , Humanos , Masculino , Veias Pulmonares/cirurgia , Recidiva , Taquicardia , Resultado do Tratamento
19.
JACC Clin Electrophysiol ; 8(2): 168-178, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-35210073

RESUMO

OBJECTIVES: This study sought to introduce a computed tomography (CT) protocol for optimal planning of vein of Marshall (VOM) catheterization. BACKGROUND: Ethanol infusion into the VOM (Et-VOM) is increasingly used in atrial fibrillation ablation. METHODS: Preprocedural CT was performed with either a conventional (conv-CT; n = 132) or an optimized CT protocol (VOM-CT; n = 126) designed for obtaining on a single image both left atrial and coronary sinus (CS) enhancement. The detection rate and anatomical features of the CT-derived VOM were analyzed and the utility of VOM-CT protocol was assessed by comparing the procedural data. RESULTS: VOM was detected in 35% in conv-CT versus 63% in VOM-CT (P < 0.001). The VOM-CT protocol did not impair the assessment of left atrial anatomy and appendage patency. In VOM-CT, the detection of the VOM was related to body mass index and width of epicardial space on posterior wall. Mean distance between CS ostium and VOM was 36 ± 7 mm. Mean VOM diameter was 1.6 ± 0.3 mm. On the CS circumference, the VOM emerged superiorly in 68% and postero-superiorly in 32%. Ethanol infusion into the VOM was attempted in 165 patients (77 conv-CT, 70 VOM-CT, and 18 without-CT). After registration in CARTO, the VOM segmented on CT matched its location on venography in all cases. As compared with conv-CT and without-CT, procedures guided by VOM-CT showed significantly shorter radiation time, shorter procedure time, lower amount of the contrast medium, and fewer contrast injections to obtain VOM catheterization. CONCLUSIONS: The proposed CT protocol allows for improved visualization of the VOM, translating into easier VOM catheterization.


Assuntos
Ablação por Cateter , Etanol , Ablação por Cateter/métodos , Humanos , Infusões Intravenosas , Tomografia , Tomografia Computadorizada por Raios X
20.
J Electrocardiol ; 71: 67-73, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35183045

RESUMO

BACKGROUND: Paradoxical ventriculophasic response (P-VR), a rare entity, has not been fully investigated. This study sought to compare the electrocardiographic features of P-VR and typical ventriculophasic response (T-VR). METHODS: The 12­lead electrocardiogram (ECG) data recorded before implantation of a cardiac implantable electronic device were analyzed in patients with greater than second-degree atrioventricular block (AVB). P-VR or T-VR was defined as present if the PP interval interposing a QRS complex was prolonged or shortened, respectively, by >3% compared with the preceding PP interval without a QRS complex when a QRS complex occurred within a span of 60% of the preceding PP interval. RESULTS: Of 95 patients (age 80 ± 9 years; 49 men) with heart block, 1868 instances (an instance was defined as a set of PP intervals without a QRS complex and the subsequent PP interval interposing a QRS complex) from 214 ECGs were analyzed: 894 instances from 122 ECGs in 64 patients with complete AVB (cAVB) and 974 instances from 92 ECGs in 43 patients with 2:1 AVB (12 showed both cAVB and 2:1 AVB). P-VR was observed in 48 patients (51%). The position of the interposed QRS complex relative to the preceding PP interval was earlier in P-VR than in T-VR. The PP interval was shorter in P-VR than in T-VR. CONCLUSION: P-VR was present in >50% of patients and was affected by the position of the interposed QRS complex and the PP interval.


Assuntos
Bloqueio Atrioventricular , Eletrocardiografia , Idoso , Idoso de 80 Anos ou mais , Bloqueio Atrioventricular/diagnóstico , Feminino , Humanos , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...