Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-31973062

RESUMO

In South Korea, the installation of septic tanks for treating black water (STBW) is regulated even in sewage treatment areas to prevent the black water deposition in combined sewers. STBWs in which black water is anaerobically decomposed generate high concentrations of hydrogen sulfide (H2S). In this study, an immobilized media of sulfur-oxidizing bacteria (SOB) was used to remove the H2S. SOB media was prepared by using activated sludge collected from a wastewater treatment plant. Prior to field application, an appropriate cultivation period and aeration rate for SOB activation were estimated through a laboratory-scale test. The SOB was activated after a 23-day cultivation period and an aeration rate of 0.25 L-water/L-air/min. Moreover, the maximum H2S removal efficiency was observed at a cultivation period of 43 days and an aeration rate of 0.38 L-water/L-air/min. Then, the SOB media was installed on STBWs of various capacities. The H2S removal efficiency was compared between with and without SOB media. The maximum H2S elimination capacity with SOB media was 12.3 g/m3/h, which was approximately three times higher than without SOB media. Furthermore, the energy efficiency and oxidation rate were also three times higher with SOB, demonstrating the applicability of SOB for H2S removal in STBW.


Assuntos
Bactérias , Reatores Biológicos , Sulfeto de Hidrogênio , Engenharia Sanitária , Bactérias/metabolismo , Veículos Automotores , Oxirredução , República da Coreia , Enxofre , Água
2.
J Hazard Mater ; 341: 75-82, 2018 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-28768223

RESUMO

The indoor air quality of subway systems can significantly affect the health of passengers since these systems are widely used for short-distance transit in metropolitan urban areas in many countries. The particles generated by abrasion during subway operations and the vehicle-emitted pollutants flowing in from the street in particular affect the air quality in underground subway stations. Thus the continuous monitoring of particulate matter (PM) in underground station is important to evaluate the exposure level of PM to passengers. However, it is difficult to obtain indoor PM data because the measurement systems are expensive and difficult to install and operate for significant periods of time in spaces crowded with people. In this study, we predicted the indoor PM concentration using the information of outdoor PM, the number of subway trains running, and information on ventilation operation by the artificial neural network (ANN) model. As well, we investigated the relationship between ANN's performance and the depth of underground subway station. ANN model showed a high correlation between the predicted and actual measured values and it was able to predict 67∼80% of PM at 6 subway station. In addition, we found that platform shape and depth influenced the model performance.

3.
Environ Pollut ; 231(Pt 1): 663-670, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28846987

RESUMO

Exposure to airborne particulate matter (PM) causes several diseases in the human body. The smaller particles, which have relatively large surface areas, are actually more harmful to the human body since they can penetrate deeper parts of the lungs or become secondary pollutants by bonding with other atmospheric pollutants, such as nitrogen oxides. The purpose of this study is to present the number of PM inhaled by subway users as a possible reference material for any analysis of the hazards to the human body arising from the inhalation of such PM. Two transfer stations in Seoul, Korea, which have the greatest number of users, were selected for this study. For 0.3-0.422 µm PM, particle number concentration (PNC) was highest outdoors but decreased as the tester moved deeper underground. On the other hand, the PNC between 1 and 10 µm increased as the tester moved deeper underground and showed a high number concentration inside the subway train as well. An analysis of the particles to which subway users are actually exposed to (inhaled particle number), using particle concentration at each measurement location, the average inhalation rate of an adult, and the average stay time at each location, all showed that particles sized 0.01-0.422 µm are mostly inhaled from the outdoor air whereas particles sized 1-10 µm are inhaled as the passengers move deeper underground. Based on these findings, we expect that the inhaled particle number of subway users can be used as reference data for an evaluation of the hazards to health caused by PM inhalation.


Assuntos
Poluentes Atmosféricos/análise , Monitoramento Ambiental , Exposição por Inalação/estatística & dados numéricos , Material Particulado/análise , Humanos , Tamanho da Partícula , Ferrovias/estatística & dados numéricos , República da Coreia , Seul
4.
Environ Monit Assess ; 188(6): 362, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27220501

RESUMO

As the number of people using rapid transit systems (subways) continues to rise in major cities worldwide, increasing attention has been given to the indoor air quality of underground stations. This study intended to observe the change of PM distribution by size in an underground station with PSDs installed located near the main road in downtown Seoul, as well as to examine causes for the changes. The results indicate that the PM suspended in the tunnel flowed into the platform area even in a subway station where the effect of train-induced wind is blocked by installed PSDs, as this flow occurred when the PSDs were opened. The results also indicate that coarse mode particles generated by mechanical friction in the tunnel, such as that between wheels and rail, also flowed into the platform area. The PM either settled or was re-suspended according to size and whether the ventilation in the platform area was in operation or if the platform floor had been washed. The ventilation system was more effective in removing PM of smaller sizes (fine particles) while the wash-out performed after train operations had stopped reduced the suspension of coarse mode particles the next morning. Despite installation of the completely sealed PSDs, inflow of coarse mode particles from the tunnel seems unavoidable, indicating the need for measures to decrease the PM generated there to lower subway user exposure since those particles cannot be reduced by mechanical ventilation alone. This research implicate that coarse PM containing heavy metals (generated from tunnel side) proliferated especially during rush hours, during which it is very important to control those PM in order to reduce subway user exposure to this hazardous PM.


Assuntos
Aerossóis/análise , Poluição do Ar em Ambientes Fechados/análise , Tamanho da Partícula , Material Particulado/análise , Ferrovias , Poluentes Atmosféricos/análise , Cidades , Monitoramento Ambiental/métodos , Humanos , Ventilação
5.
Environ Sci Technol ; 50(7): 3453-61, 2016 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-26967707

RESUMO

In this study, we measured the size distribution of particles ranging in size from 5.6 to 560 nm that were emitted between brake disks and pads under various braking conditions to observe and analyze changes to the resulting particle size distribution over braking time. A peak of 178-275 nm (200 nm peak) was observed in all braking conditions. However, the generation of spherical particles of a 10 nm range was observed only when the disk speed and brake force were above certain levels and intensified only when speed and brake force further increased. The total number concentration of ultrafine particles (no larger than 0.1 µm; PM0.1) generated was found to correlate with disk speed and brake force. Thus, the generation of nanoparticles resulting from disk speed and brake force was attributable primarily to increases in the contact surface temperature. The critical temperature for the generation of nanoparticles of a 10 nm range was found to be about 70 °C, which is the average temperature between the surface and the inside of the disk. If the speed or brake force was higher, that is, the temperature of the contact surface reached a certain level, evaporation and condensation took place. Vapor then left the friction surface, met with the air, and quickly cooled to form nanoparticles through nucleation. When the newly generated particles became highly concentrated, they grew through coagulation to form agglomerates or the vapor condensed directly onto the surface of existing particles of about 200 nm (formed by mechanical friction).


Assuntos
Poluentes Atmosféricos/análise , Nanopartículas , Ferrovias , Poluentes Atmosféricos/química , Fricção , Nanopartículas/análise , Nanopartículas/química , Tamanho da Partícula , Temperatura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA