1.
Micromachines (Basel) ; 13(4)2022 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-35457851

RESUMO

Liquid crystal polymer (LCP) has gained wide interest in the electronics industry largely due to its flexibility, stable insulation and dielectric properties and chip integration capabilities. Recently, LCP has also been investigated as a biocompatible substrate for the fabrication of multielectrode arrays. Realizing a fully implantable LCP-based bioelectronic device, however, still necessitates a low form factor packaging solution to protect the electronics in the body. In this work, we investigate two promising encapsulation coatings based on thin-film technology as the main packaging for LCP-based electronics. Specifically, a HfO2-based nanolaminate ceramic (TFE1) deposited via atomic layer deposition (ALD), and a hybrid Parylene C-ALD multilayer stack (TFE2), both with a silicone finish, were investigated and compared to a reference LCP coating. T-peel, water-vapour transmission rate (WVTR) and long-term electrochemical impedance spectrometry (EIS) tests were performed to evaluate adhesion, barrier properties and overall encapsulation performance of the coatings. Both TFE materials showed stable impedance characteristics while submerged in 60 °C saline, with TFE1-silicone lasting more than 16 months under a continuous 14V DC bias (experiment is ongoing). The results presented in this work show that WVTR is not the main factor in determining lifetime, but the adhesion of the coating to the substrate materials plays a key role in maintaining a stable interface and thus longer lifetimes.

2.
Annu Int Conf IEEE Eng Med Biol Soc ; 2020: 3436-3439, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-33018742

RESUMO

To meet the dimensional requirements for bioelectronic medicine, new packaging solutions are needed that could enable small, light-weight and flexible implants. For protecting the implantable electronics against biofluids, recently various atomic layer deposited (ALD) coatings have been proposed with high barrier properties. Before implantation, however, the protective coating should be evaluated for any defects which could otherwise lead to leakage and device failure. In these cases, the conventional helium leak test method can no longer be used due to the millimeter size of the implant. Therefore, an in-situ sensing platform is needed that could evaluate the coating and justify the implantation of the final device. In this work, we explore the possibility of using the CMOS bulk for such a platform. Towards this aim, as a proof of concept, test chips were made in a standard 6-metal 0.18 µm CMOS process and for the connection to the bulk, a p+ diffusion was used. A group of samples was then coated with an ALD multilayer. For coating evaluation, off-chip DC current leakage and impedance measurements were carried out in saline between the CMOS bulk and a platinum reference electrode. Results were compared between non-coated and coated chips that clearly demonstrated the potential of using the bulk as a sensing platform for coating evaluations. This novel approach could pave the way towards an all integrated in-situ hermeticity test, currently missing in mm-size implants.


Assuntos
Metais , Próteses e Implantes , Eletrodos
3.
IEEE Trans Biomed Circuits Syst ; 14(4): 658-670, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32746351

RESUMO

For mm-sized implants incorporating silicon integrated circuits, ensuring lifetime operation of the chip within the corrosive environment of the body still remains a critical challenge. For the chip's packaging, various polymeric and thin ceramic coatings have been reported, demonstrating high biocompatibility and barrier properties. Yet, for the evaluation of the packaging and lifetime prediction, the conventional helium leak test method can no longer be applied due to the mm-size of such implants. Alternatively, accelerated soak studies are typically used instead. For such studies, early detection of moisture/ion ingress using an in-situ platform may result in a better prediction of lifetime functionality. In this work, we have developed such a platform on a CMOS chip. Ingress of moisture/ions would result in changes in the resistance of the interlayer dielectrics (ILD) used within the chip and can be tracked using the proposed system, which consists of a sensing array and an on-chip measurement engine. The measurement system uses a novel charge/discharge based time-mode resistance sensor that can be implemented using simple yet highly robust circuitry. The sensor array is implemented together with the measurement engine in a standard 0.18  µm 6-metal CMOS process. The platform was validated through a series of dry and wet measurements. The system can measure the ILD resistance with values of up to 0.504 peta-ohms, with controllable measurement steps that can be as low as 0.8 M Ω. The system works with a supply voltage of 1.8 V, and consumes 4.78 mA. Wet measurements in saline demonstrated the sensitivity of the platform in detecting moisture/ion ingress. Such a platform could be used both in accelerated soak studies and during the implant's life-time for monitoring the integrity of the chip's packaging.


Assuntos
Eletrônica Médica/instrumentação , Desenho de Equipamento/métodos , Próteses e Implantes , Semicondutores , Íons/análise , Metais/química , Falha de Prótese , Silício/química , Água/análise
4.
Annu Int Conf IEEE Eng Med Biol Soc ; 2019: 3840-3844, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31946711

RESUMO

Platinum is widely used as the electrode material for implantable devices. Owing to its high biostability and corrosion resistivity, platinum could also be used as the main metallization for tracks in active implants. Towards this goal, in this work we investigate the stability of parylene-coated Pt tracks using passive and active tests. The test samples in this study are Pt-on-SiO2 interdigitated comb structures. During testing all samples were immersed in saline for 150 days; for passive testing, the samples were left unbiased, whilst for active testing, samples were exposed to two different stress signals: a 5 V DC and a 5 Vp 500 pulses per second biphasic signal. All samples were monitored over time using impedance spectroscopy combined with optical inspection. After the first two weeks of immersion, delamination spots were observed on the Pt tracks for both passive and actively tested samples. Despite the delamination spots, the unbiased samples maintained high impedances until the end of the study. For the actively stressed samples, two different failure mechanisms were observed which were signal related. DC stressed samples showed severe parylene cracking mainly due to the electrolysis of the condensed water. Biphasically stressed samples showed gradual Pt dissolution and migration. These results contribute to a better understanding of the failure mechanisms of Pt tracks in active implants and suggest that new testing paradigms may be necessary to fully assess the long-term reliability of these devices.


Assuntos
Materiais Revestidos Biocompatíveis , Platina , Polímeros , Dióxido de Silício , Xilenos , Falha de Equipamento , Próteses e Implantes