J Thorac Cardiovasc Surg ; 126(1): 232-9, 2003 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12878960

RESUMO

OBJECTIVE: This study examines the incidence and factors associated with the failure of homograft valves and identifies those factors that are modifiable. METHODS: From 1990 to 2001, 96 homograft valves were implanted in the right ventricular outflow tract of 83 children (mean age 5.1 +/- 5.6 years). Clinical and blinded serial echocardiographic follow-up was performed on all 90 valves in the 77 survivors. RESULTS: Eighteen homograft valves were replaced as the result of pulmonary insufficiency (3), stenosis (9), or both (6). Freedom from reoperation was 71% at 9 years (95% confidence interval, 58%-84%). Forty-eight valves developed progressive pulmonary insufficiency of at least 2 grades, 26 valves developed transvalvular gradients of 50 mm Hg or greater, and 14 of these valves were also insufficient. The freedom from echocardiographic failure (progressive pulmonary insufficiency >or=2 grades or >or=50 mm Hg gradient) was only 27% at 5 years (95% confidence interval, 17%-37%). In a multivariate analysis (Cox regression), use of an aortic homograft (P =.001) and short antibiotic preservation time (P =.04) were associated with reoperation. Younger age (P =.01), ABO mismatch (P =.04), and diagnosis (P =.005) were associated with echocardiographic failure. In the subanalysis of patients with human leukocyte antigen typing, age (P =.002), aortic homograft (P =.04), and human leukocyte antigen-DR mismatch (P =.03) were associated with echocardiographic valve failure. CONCLUSION: Many homografts rapidly become insufficient and require replacement. In our analysis of both reoperation and echocardiographic failure, several immunologic factors are consistently associated with homograft failure. Matching for human leukocyte antigen-DR, blood group, and avoiding short preservation times (thus minimizing antigenicity) offers the potential to extend the life of these valves.


Assuntos
Sistema ABO de Grupos Sanguíneos/sangue , Antígenos HLA/sangue , Valva Pulmonar/transplante , Adolescente , Adulto , Fatores Etários , Canadá/epidemiologia , Criança , Proteção da Criança , Pré-Escolar , Progressão da Doença , Ecocardiografia , Feminino , Seguimentos , Antígenos HLA-DR/sangue , Cardiopatias Congênitas/sangue , Cardiopatias Congênitas/mortalidade , Cardiopatias Congênitas/cirurgia , Implante de Prótese de Valva Cardíaca , Teste de Histocompatibilidade , Humanos , Incidência , Lactente , Bem-Estar do Lactente , Recém-Nascido , Masculino , Análise Multivariada , Falha de Prótese , Valva Pulmonar/anormalidades , Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/sangue , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/cirurgia , Estenose da Valva Pulmonar/sangue , Estenose da Valva Pulmonar/diagnóstico por imagem , Estenose da Valva Pulmonar/cirurgia , Reoperação , Índice de Gravidade de Doença , Estatística como Assunto , Análise de Sobrevida , Transplante Homólogo , Obstrução do Fluxo Ventricular Externo/sangue , Obstrução do Fluxo Ventricular Externo/congênito , Obstrução do Fluxo Ventricular Externo/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...