Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Cornea ; 43(4): 534-536, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38166177

RESUMO

PURPOSE: The aim of this study was to describe the feasibility and applicability of a reverse 4-throw (RFT) pupilloplasty technique for endothelial keratoplasty. METHODS: In RFT, the 9-0 polypropylene suture needle and a 26-Gauge needle pierce the iris tissue from the posterior surface to emerge on the anterior surface along the proximal and distal portion of iris tissue to be apposed, respectively. The 9-0 needle is threaded into the barrel of a 26-Gauge needle and is withdrawn from the eye. The suture loop is withdrawn and the suture end is passed through the loop 4 times. Both suture ends are pulled, which leads to the sliding of the loop inside the eye, thereby apposing the iris tissue with the knot lying on the posterior surface. RESULTS: The procedure was performed in 11 eyes of 11 patients who were scheduled to undergo an endothelial keratoplasty procedure. The anterior segment optical coherence tomography image of the RFT pupilloplasty did not denote any presence of the suture in the anterior chamber or along the anterior surface of the iris plane. No incidence of primary graft failure or graft rejection during the entire follow-up period was reported in any of the eyes. CONCLUSIONS: RFT serves as an effective technique for performing pupilloplasty in endothelial keratoplasty cases without the presence of a knot or suture tail in the anterior chamber.


Assuntos
Transplante de Córnea , Procedimentos de Cirurgia Plástica , Humanos , Iris/cirurgia , Procedimentos Cirúrgicos Oftalmológicos , Câmara Anterior/cirurgia , Técnicas de Sutura
2.
Curr Opin Ophthalmol ; 35(1): 23-27, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-37962881

RESUMO

PURPOSE OF REVIEW: The aim of this study to provide an overview of recent publications and opinions in refractive cataract surgery. RECENT FINDINGS: With the advent of intraocular lenses (IOLs) on different platforms, the surgeon has a wide arena of types of IOL to choose, depending on the patient's visual requirement. Optimization of the tear film, integrating tomography and topography devices for appropriate keratometry values, biometry, use of advanced formulas for IOL power calculation and application of newer IOLs can help achieve target refraction in cases scheduled for cataract surgery. Intraoperative aberrometry can be a useful aid for cataract surgery in postrefractive cases and can help minimize residual postoperative astigmatism. SUMMARY: Evolvement and rapid advancement of technology allows to impart desired refractive outcomes in most of the cases postcataract surgery. Appropriate preoperative and intraoperative factors should be considered to achieve the desired postoperative outcome.


Assuntos
Astigmatismo , Extração de Catarata , Catarata , Lentes Intraoculares , Facoemulsificação , Humanos , Implante de Lente Intraocular , Refração Ocular , Astigmatismo/cirurgia , Biometria/métodos , Facoemulsificação/métodos
3.
J Cataract Refract Surg ; 50(3): 264-269, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-37899510

RESUMO

PURPOSE: To determine optimal pinhole size (OPS) and establish a relationship with visual acuity (VA) and RMS (root mean square) values in cases with higher-order aberrations (HOAs) undergoing pinhole pupilloplasty (PPP). SETTING: Private practice, India. DESIGN: Prospective, interventional study. METHODS: RMS value for 6-mm-diameter optical zone was determined by Scheimpflug imaging (Pentacam). Patients with RMS value >0.3 µm were included. Preoperatively, a hand-held pinhole gauge with varied apertures determined the OPS, and single-pass four-throw technique was used to perform pupilloplasty with Purkinje-1 reflex as a marker for centration. VA with OPS, correlation of RMS values with OPS and pupil size, and Strehl ratio were the main outcome measures. RESULTS: 29 eyes with HOAs were analyzed; all patients chose 1.0 or 1.5 mm as OPS. The mean preoperative and postoperative pupil size was 3.25 ± 0.81 mm and 1.8 ± 0.54 mm ( P = .000), respectively. Postoperative mean pupil size when compared with OPS denoted that 14 eyes had a difference of <0.1 mm, 8 eyes ranged from 0.2 to 0.45 mm, and 7 eyes had ≥0.6 mm (range from 0.6 to 1.8 mm) difference from OPS. Eyes with higher RMS values needed smaller pupil gauge to achieve better VA. Preoperatively, vision with OPS correlated well with preoperative 6-mm RMS HOAs ( r = 0.728; P = .00). Postoperative UDVA correlated well with VA measured with OPS ( r = 0.847; P = .00). The preoperative and postoperative mean Strehl ratio was 0.109 ± 0.07 and 0.195 ± 0.11 ( P = .001), respectively. CONCLUSIONS: Higher RMS values required a smaller pupil to achieve optimum VA. PPP can help achieve pinhole size in accordance with patient's optimum pinhole requirement.


Assuntos
Pupila , Refração Ocular , Humanos , Estudos Prospectivos , Acuidade Visual , Córnea
4.
Cornea ; 2023 Sep 12.
Artigo em Inglês | MEDLINE | ID: mdl-37699570

RESUMO

PURPOSE: The aim of this study was to analyze the outcomes of pre-Descemet endothelial keratoplasty (PDEK) for failed therapeutic penetrating keratoplasty. METHODS: This was a retrospective, interventional study that involved 12 eyes of 12 patients with failed therapeutic penetrating keratoplasty that underwent PDEK. All cases had a minimum follow-up of 12 months. The main outcome measures were best-corrected visual acuity, graft clarity, endothelial cell density loss, and graft survival. Corneal clarity was graded on a scale from 0 to 4, where grade 4 denoted an absolutely clear cornea and grade 0 denoted a totally opaque cornea. Three cases underwent PDEK, 6 cases PDEK with phacoemulsification, and 3 cases underwent PDEK with pupilloplasty. RESULTS: The mean follow-up period for all cases was 18.5 ± 4.9 months. The mean preoperative and postoperative best-corrected visual acuity (in Snellen decimal equivalent) was 0.02 ± 0.01 and 0.54 ± 0.17, respectively, at the last follow-up. Postoperatively, corneal clarity grade 4 was present in 9 eyes, grade 3 in 2 eyes, and grade 2 in 1 eye. Mild subepithelial haze was noted in 2 eyes. The percentage of endothelial cell density loss was 28.2% ± 10.6%. No correlation was observed between the postoperative graft clarity and preoperative specular count (r = -0.021, P = 0.512). Rebubbling was performed for 1 eye that developed partial graft detachment in the first postoperative week. One patient had an episode of rejection that was managed with systemic and topical steroids. CONCLUSIONS: In patients with failed therapeutic penetrating keratoplasty, PDEK can be a useful alternative for visual rehabilitation as it demonstrates favorable visual outcomes with a good graft survival rate.

5.
J Cataract Refract Surg ; 49(8): 898-899, 2023 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-37482668

RESUMO

A 75-year-old man with an ocular history of 8-cut radial keratotomy (RK) in both eyes presented for cataract surgery evaluation. He was previously correctable in spectacles in years prior despite his irregular corneas to 20/25 in the right eye and 20/30 in the left eye. He recently noticed a change in his overall visual function with significant nighttime glare and difficulty reading despite spectacle correction. Of note, he was unable to tolerate contact lenses and was resistant to refitting despite additional encouragement. Cataract surgery was delayed for many years, given he was correctable in spectacles and the concern of uncovering a highly aberrated cornea after removing his cataracts (Figures 1 and 2JOURNAL/jcrs/04.03/02158034-202308000-00021/figure1/v/2023-07-21T030437Z/r/image-tiffJOURNAL/jcrs/04.03/02158034-202308000-00021/figure2/v/2023-07-21T030437Z/r/image-tiff). Of note, the patient was interested in returning to the spectacle independence he enjoyed in the past. Ocular examination revealed a corrected distance visual acuity (CDVA) of 20/30 in the right eye and 20/60 in the left eye, with a manifest refraction of +4.50 -0.50 × 177 in the right eye and +5.75 -1.75 × 14 in the left eye. Glare testing was 20/50 in the right eye and 20/100 in the left eye, with retinal acuity meter testing of 20/25 in each eye. Pupils, confrontation visual fields, and intraocular pressures were normal. Pertinent slitlamp examination revealed corneal findings of 8-cut RK with nasal-gaping arcuate incisions in both eyes and lens findings of 2+ nuclear sclerosis with 2+ cortical changes in the right eye and 3+ nuclear sclerosis with 3+ cortical changes in the left eye. Cup-to-disc ratios of the optic nerves measured 0.5 with temporal sloping in the right eye and 0.6 with temporal sloping in the left eye. The dilated fundus examination was unremarkable. What intraocular lens (IOL) options would you offer this patient and how would you counsel regarding realistic expectations? What additional diagnostic testing would be helpful in your assessment? How would you calculate the IOLs?


Assuntos
Extração de Catarata , Catarata , Ceratotomia Radial , Lentes Intraoculares , Masculino , Humanos , Idoso , Emetropia , Esclerose , Catarata/complicações
6.
Eur J Ophthalmol ; 33(5): 2042-2046, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36940730

RESUMO

PURPOSE: To describe Reverse four-throw (RFT) technique for pupilloplasty. METHODS: The technique involves making a single pass through the anterior chamber that helps achieve a posteriorly directed suture knot. A single arm 9-0 polypropylene suture attached to long arm needle engages the iris defects with the tip of the needle piercing the iris tissue from the posterior surface and emerging from the anterior aspect. The suture end is passed from the loop with four throws taken consecutively in the same direction that create a self-sealing and self-retaining lock like single-pass four-throw technique but with the difference that the knot slides on the posterior surface of the iris tissue. RESULTS: The technique was performed in 9 eyes and the suture-loop easily slided along the posterior surface of iris tissue. The iris defect was well approximated in all the cases and the suture knot or suture tail was not visible in the anterior chamber. Anterior segment optical coherence tomography depicted smooth iris configuration with no suture extrusion in the anterior chamber. CONCLUSIONS: The RFT technique provides an effective measure to seal the iris defect with the absence of knot in AC.


Assuntos
Iris , Procedimentos de Cirurgia Plástica , Humanos , Iris/cirurgia , Procedimentos Cirúrgicos Oftalmológicos , Câmara Anterior/cirurgia , Tomografia de Coerência Óptica/métodos , Suturas , Técnicas de Sutura
7.
Ophthalmol Sci ; 3(2): 100264, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36846107

RESUMO

Purpose: To evaluate diagnostic precision and prove equivalence of 2 devices, Advanced vision analyzer (AVA, Elisar Vision Technology) and Humphrey field analyzer (HFA, Zeiss) for the detection of glaucoma on 10-2 program. Design: Prospective, cross-sectional, observational study. Participants: Threshold estimates of 1 eye each of 66 patients with glaucoma, 36 control participants, and 10 glaucoma suspects were analyzed on 10-2 test with AVA and HFA. Methods: Mean sensitivity (MS) values of 68 points and central 16 test points were calculated and compared. Intraclass correlation (ICC), Bland-Altman (BA) plots, linear regression of MS, mean deviation (MD), and pattern standard deviation (PSD) were computed to assess the 10-2 threshold estimate of the devices. Receiver operating characteristic curves were generated for MS and MD values, and the area under the curve (AUC) was compared with assessing diagnostic precision. Main Outcome Measures: Mean sensitivity values of 68 points and central 16 points, AUC for MS and MD values, ICC values, BA plots, and linear-regression analysis. Results: Bland-Altman plot showed significant correlation for MS, MD, and PSD values for both devices. For MS, the overall ICC value was 0.96 (P < 0.001) with a mean bias of 0.0 dB and limits of agreement range of 7.59. The difference in MS values between both devices was -0.4760 ± 1.95 (P > 0.05). The AUC for MS values for AVA was 0.89 and for HFA was 0.92 (P = 0.188); whereas it was similar at 0.88 for MD values (P = 0.799). Advanced vision analyzer and HFA identically discriminated between healthy and patients with glaucoma (P < 0.001), although HFA denoted marginally greater ability (P > 0.05). Conclusions: Statistical results denote adequate equivalence between AVA and HFA because threshold estimates of AVA strongly correlate with HFA for 10-2 program. Financial Disclosures: Proprietary or commercial disclosure may be found after the references.

9.
Indian J Ophthalmol ; 70(10): 3745-3746, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-36190103

RESUMO

Background: Silicon oil is an important adjunct for achieving internal tamponade in the treatment of retinal detachment. Silicone oil tamponade often leads to narrowing of the angle and development of adhesions between the iris and anterior chamber angle structures, with consequential elevation of the intraocular pressure. The video showcases the management of these challenging scenarios. Purpose: To highlight the management of early synechial closures due to silicon oil tamponade. Synopsis: The video highlights the management of early synechial closure following silicon oil tamponade. Surgical pupilloplasty has been demonstrated to break the peripheral anterior synechias on intraoperative gonioscopy as well as on anterior segment optical coherence tomography (AS-OCT). Performing pupilloplasty in the early phase of development of peripheral anterior synechias (PAS) helps to break the existing synechias and prevent angle closure and sequential deterioration of vision. Highlights: Surgical pupilloplasty helps to relieve the post silicon oil-induced secondary angle closure glaucoma by breaking the peripheral anterior synechias and significantly opening the anterior chamber angles. Online Video Link: https://youtu.be/xe2NGlhPBF4.


Assuntos
Anormalidades do Olho , Glaucoma de Ângulo Fechado , Glaucoma , Doenças da Íris , Segmento Anterior do Olho/patologia , Glaucoma/diagnóstico , Glaucoma/etiologia , Glaucoma/cirurgia , Glaucoma de Ângulo Fechado/cirurgia , Gonioscopia , Humanos , Pressão Intraocular , Iris/cirurgia , Doenças da Íris/diagnóstico , Doenças da Íris/cirurgia , Óleos de Silicone/efeitos adversos , Aderências Teciduais , Tomografia de Coerência Óptica/métodos , Tonometria Ocular
10.
Indian J Ophthalmol ; 70(9): 3432, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-36018147

RESUMO

Background: Disinsertion of iris leads to debilitating sequelae like diplopia and glare. Hence, iridodialysis repair is essential to optimize the visual quality. Iris base repair often leads to corectopia that necessitates an additional procedure to optimize the pupil shape and size. Twofold technique helps to achieve both the aspects. Purpose: To highlight the technique of twofold iridodialysis repair. Synopsis: The video highlights the method of twofold iridodialysis repair, wherein nonappositional repair is followed by single-pass four-throw (SFT) pupilloplasty that allows adequate closure of varied degrees of iridodialysis along with centration of eccentric pupil. Highlights: The twofold technique is a combination of nonappositional iris repair and SFT procedure. It can be clinically applied in all cases of iridodialysis with varied degrees of severity. Online Video Link: https://youtu.be/OncBdz2UIBY.


Assuntos
Doenças da Íris , Distúrbios Pupilares , Humanos , Iris , Técnicas de Sutura , Suturas
11.
Indian J Ophthalmol ; 70(8): 3166, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35919013

RESUMO

Background: Surgeons often notice unexplained dilation of the pupil following an uncomplicated intra-ocular surgery. No definite line of treatment has been proposed for managing Urrets-Zavalia syndrome (UZS). The authors have previously documented the results of surgical pupilloplasty and have outlined this modality of treatment for cases with UZS. Purpose: To highlight the aspect of development of UZS post-operatively in the eyes following an intra-ocular surgery. Synopsis: The video highlights the aspect of prevalence of the persistently dilated pupil that is non-responsive to topical miotics. Apart from associated glare, these cases often have raised intra-ocular pressure because of appositional closure of the anterior chamber angle. Surgical pupilloplasty pulls the iris tissue centrally, eventually releasing the mechanical blockage and often breakage of the peripheral anterior synechias as demonstrated by intra-operative gonioscopy and anterior segment optical coherence tomography. Highlights: Performing a surgical pupilloplasty can resolve the UZS, and timely intervention can also prevent the development of secondary glaucoma because of fallback of the iris tissue on the structures of the anterior chamber angle. Online Video Link: https://youtu.be/IF_w8dVk5_w.


Assuntos
Glaucoma de Ângulo Fechado , Glaucoma , Doenças da Íris , Distúrbios Pupilares , Glaucoma/complicações , Glaucoma/diagnóstico , Glaucoma/cirurgia , Glaucoma de Ângulo Fechado/cirurgia , Gonioscopia , Humanos , Pressão Intraocular , Iris/cirurgia , Doenças da Íris/complicações , Doenças da Íris/diagnóstico , Doenças da Íris/cirurgia , Distúrbios Pupilares/etiologia , Tomografia de Coerência Óptica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...