Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 95(3): 398-407, 2020 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-31609073

RESUMO

AIMS: To evaluate outcomes of transfemoral transcatheter aortic valve implantation (TF-TAVI) using three different new-generation devices. BACKGROUND: Although new generation transcatheter aortic valves (TAVs) have demonstrated to improve procedural outcomes, to date few head-to-head comparisons are available among these devices. METHODS: This is a single center, retrospective study. From September 2014 to February 2018, 389 patients underwent elective TF-TAVI for native, severe aortic stenosis using a new-generation transcatheter aortic valve (TAV) with a preprocedural multi-detector computed tomography assessment. Among these, 346 patients received an Edwards SAPIEN 3 (n = 134), Medtronic Evolut R (n = 111), or Boston ACURATE neo (n = 101) prosthesis. Differences in baseline clinical characteristics between groups were accounted using the propensity score weighting method. RESULTS: The mean age for the entire study cohort was 81.4 ± 5.2 years while the Society of Thoracic Surgery predicted risk of mortality was 4.0 ± 2.5%. After propensity score weighting adjustment, TAVs did not differently impact on 30-day all-cause and cardiovascular mortality. Evolut R device showed an increased risk of permanent pacemaker implantation (PPI) after the procedure (8.3% for SAPIEN 3 vs. 16.7% for Evolut R vs. 2.1% for ACURATE neo, p < .05). At 30 days, patients treated with SAPIEN 3 valve showed a higher mean transvalvular gradient (9.7 ± 7.5 mmHg vs. 6.1 ± 2.4 mmHg vs. 8.4 ± 3.5 mmHg for SAPIEN 3, Evolut R, and ACURATE neo, respectively, p < .01) and a lower rate of more-than-trace paravalvular regurgitation (PVR) (18.8 vs. 47.9 vs. 45.8%, for SAPIEN 3, Evolut R, and ACURATE neo, respectively, p < .01). At 1 year, SAPIEN 3, Evolut R, and ACURATE neo TAVs showed excellent and comparable outcomes with no difference in terms of freedom from major adverse cardiovascular and cerebrovascular event (MACCE) (plog-rank = 0.534). CONCLUSIONS: TAVI using new-generation prostheses was associated with high device success (97.0% vs. 92.8% vs. 95.0% for SAPIEN 3, Evolut R and ACURATE neo, respectively) and low complications rates up to 1 year. Evolut R valve was associated with a higher rate of PPI whereas SAPIEN 3 valve was associated with a higher mean transvalvular gradient and lower rate of more-than-trace PVR. At 1-year, MACCE rates were similar among the three groups.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Feminino , Hemodinâmica , Humanos , Masculino , Desenho de Prótese , Recuperação de Função Fisiológica , Estudos Retrospectivos , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
2.
Adv J Emerg Med ; 3(3): e30, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31410407

RESUMO

INTRODUCTION: We describe a patient without a history of cardiovascular diseases as an example of Wellens' syndrome (WS). CASE REPORT: A 65-year-old man presented to emergency department due to intermittent chest pain. Physical examination and chest x-ray were unremarkable. Electrocardiogram (ECG) showed biphasic T-wave in precordial leads V1-V4. Primary cardiac serum biomarkers including high-sensitive cardiac troponin T (hs-cTnT) and CK-MB were slightly elevated, that further assessment did not show any increases; while ECG recorded during a pain period revealed T-wave pseudo-normalization. The patient underwent coronary angiography that revealed a proximal left anterior descending artery lesion. CONCLUSION: WS is a diagnostic and management challenge and serial ECG evaluation is still essential for a possible acute coronary syndrome. Having knowledge of all subtle features of this syndrome, could avoid improper discharge of high-risk patients. Definitely, accurate risk stratification, and prompting these patients to an early coronary angiogram and treatment are mandatory to avoid development of a massive anterior myocardial infarction.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...