Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Circ Arrhythm Electrophysiol ; 6(3): 538-45, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23592833

RESUMO

BACKGROUND: Current recommendations require a QRS duration of ≥120 ms as a condition for prescribing cardiac resynchronization therapy (CRT). This study was designed to test the hypothesis that patients with heart failure (HF) of ischemic origin, current indications for defibrillator implantation, and QRS <120 ms may benefit from CRT in the presence of marked mechanical dyssynchrony. METHODS AND RESULTS: Patients with intraventricular dyssynchrony on echocardiography were randomly assigned to CRT or dual-chamber defibrillator implantation (CRT defibrillator and dual-chamber implantable cardioverter-defibrillator arm, respectively). The primary end point was the HF clinical composite response, which scores patients as improved, unchanged, or worsened. The secondary end point was the cumulative survival from HF hospitalization and HF death. An additional secondary end point was the composite of HF hospitalization, HF death, and spontaneous ventricular fibrillation. Twenty-three of 56 patients with CRT defibrillator showed an improvement in their clinical composite response at 1 year, compared with 9 of 55 patients with dual-chamber implantable cardioverter-defibrillator (41% versus 16%; P=0.004). After a median follow-up of 16 months, the CRT defibrillator arm showed a nonsignificant higher survival from HF hospitalization and HF death (P=0.077), and a significantly higher survival from the combined end point of HF hospitalization, HF death, and spontaneous ventricular fibrillation (P=0.028). CONCLUSIONS: In this comparison of CRT defibrillator and dual-chamber implantable cardioverter-defibrillator, CRT improved clinical status in some patients with ischemic cardiomyopathy, mild-to-moderate symptoms, narrow QRS duration, and mechanical dyssynchrony on echocardiography. CLINICAL TRIAL REGISTRATION: URL: http://clinicaltrials.gov. Unique identifier: NCT01577446.


Assuntos
Estimulação Cardíaca Artificial/métodos , Cardiomiopatias/terapia , Desfibriladores Implantáveis , Insuficiência Cardíaca/terapia , Taquicardia Ventricular/terapia , Terapia de Ressincronização Cardíaca/métodos , Cardiomiopatias/diagnóstico , Cardiomiopatias/mortalidade , Ecocardiografia Doppler , Eletrocardiografia/métodos , Feminino , Seguimentos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/mortalidade , Humanos , Estimativa de Kaplan-Meier , Masculino , Isquemia Miocárdica/diagnóstico por imagem , Isquemia Miocárdica/mortalidade , Isquemia Miocárdica/terapia , Estudos Prospectivos , Medição de Risco , Estatísticas não Paramétricas , Taxa de Sobrevida , Taquicardia Ventricular/diagnóstico , Resultado do Tratamento , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/mortalidade , Disfunção Ventricular Esquerda/terapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...