Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
2.
JACC Cardiovasc Interv ; 14(21): 2353-2364, 2021 11 08.
Artigo em Inglês | MEDLINE | ID: mdl-34656496

RESUMO

OBJECTIVES: This study evaluated the long-term efficacy of a standard antithrombotic strategy versus half-dose direct oral anticoagulation (DOAC) after Watchman implantation. BACKGROUND: No consensus currently exists on the selection of the most effective antithrombotic strategy to prevent device-related thrombosis (DRT) in patients undergoing endocardial left atrial appendage closure. METHODS: After successful left atrial appendage closure, consecutive patients were prescribed a standard antithrombotic strategy (SAT) or long-term half-dose DOAC (hdDOAC). The primary composite endpoint was DRT and thromboembolic (TE) and bleeding events. RESULTS: Overall, 555 patients (mean age 75 ± 8 years, 63% male; median CHA2DS2-VASc [congestive heart failure, hypertension, age ≥75 years, diabetes mellitus, prior stroke or transient ischemic attack or thromboembolism, vascular disease, age 65-74 years, sex category] score 4 [interquartile range (IQR): 3-6]; median HAS-BLED [hypertension, abnormal renal or liver function, stroke, bleeding, labile international normalized ratio, elderly, drugs or alcohol] score 3 [IQR: 2-4]) were included. Patients were categorized into 2 groups (SAT: n = 357 vs hdDOAC: n = 198). Baseline clinical characteristics were similar between groups. The median follow-up duration was 13 months (IQR: 12-15 months). DRT occurred in 12 (2.1%) patients, all in the SAT group (3.4% vs 0.0%; log-rank P = 0.009). The risk of nonprocedural major bleeding was significantly more favorable in the hdDOAC group (0.5% vs. 3.9%; log-rank P = 0.018). The rate of the primary composite endpoint of DRT and TE and major bleeding events was 9.5% in SAT patients and 1.0% in hdDOAC patients (HR: 9.8; 95% CI: 2.3-40.7; P = 0.002). CONCLUSIONS: After successful Watchman implantation, long-term half-dose DOAC significantly reduced the risk of the composite endpoint of DRT and TE and major bleeding events compared with a standard, antiplatelet-based, antithrombotic therapy.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Acidente Vascular Cerebral , Idoso , Idoso de 80 Anos ou mais , Anticoagulantes/efeitos adversos , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Feminino , Fibrinolíticos/efeitos adversos , Humanos , Masculino , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Resultado do Tratamento
3.
Europace ; 23(12): 1939-1949, 2021 12 07.
Artigo em Inglês | MEDLINE | ID: mdl-34417816

RESUMO

AIMS: We evaluated the efficacy of an ablation strategy empirically targeting pulmonary veins (PVs) and posterior wall (PW) and the prevalence and clinical impact of extrapulmonary trigger inducibility and ablation in a large cohort of patients with persistent atrial fibrillation (PerAF). METHODS AND RESULTS: A total of 1803 PerAF patients were prospectively enrolled. All patients underwent pulmonary vein antrum isolation (PVAI) extended to the entire PW. A standardized protocol was performed to confirm persistent PVAI and elicit any triggers originating from non-PV sites. All non-PV triggers initiating sustained atrial tachyarrhythmias were ablated. Ablation of non-PV sites triggering non-sustained runs (<30 s) of atrial tachyarrhythmias or promoting frequent premature atrial complexes (≥10/min) was left to operator's discretion. Overall, 1319 (73.2%) patients had documented triggers from non-PV areas. After 17.4 ± 8.5 months of follow-up, the cumulative freedom from atrial tachyarrhythmias among patients without inducible non-PV triggers (n = 484) was 70.2%. Patients with ablation of induced non-PV triggers had a significantly higher arrhythmia control than those whose triggers were not ablated (67.9% vs. 39.4%, respectively; P < 0.001). After adjusting for clinically relevant variables, patients in whom non-PV triggers were documented but not ablated had an increased risk of arrhythmia relapse (hazard ratio: 2.39; 95% confidence interval: 2.01-2.83; P < 0.001). CONCLUSION: Pulmonary vein antrum isolation extended to the entire PW might provide acceptable long-term arrhythmia-free survival in PerAF patients without inducible non-PV triggers. In our population of PerAF patients, non-PV triggers could be elicited in ∼70% of PerAF patients and their elimination significantly improved outcomes.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Humanos , Estudos Prospectivos , Veias Pulmonares/cirurgia , Recidiva , Sistema de Registros , Resultado do Tratamento
4.
JACC Clin Electrophysiol ; 7(12): 1573-1584, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34330671

RESUMO

OBJECTIVES: The aim of this study was to evaluate the efficacy of radiofrequency (RF) energy applications targeting the atrial side of a significant residual leak in patients with acute and chronic evidence of incomplete percutaneous left atrial appendage (LAA) occlusion. BACKGROUND: RF applications have been proved to prevent recanalization of intracranial aneurysms after coil embolization, thereby favoring complete sealing. From a mechanistic standpoint, in vitro and in vivo experiments have demonstrated that RF promotes collagen deposition and tissue retraction. METHODS: Forty-three patients (mean age 75 ± 7 years mean CHA2DS2-VASc score 4.6 ± 1.4, mean HAS-BLED score 4.0 ± 1.1) with residual leaks ≥4 mm after Watchman implantation were enrolled. Procedural success was defined as complete LAA occlusion or presence of a mild or minimal (1- to 2-mm) peridevice leak on follow-up transesophageal echocardiography (TEE), which was performed approximately 45 days after the procedure. RESULTS: RF-based leak closure was performed acutely after Watchman implantation in 19 patients (44.2%) or scheduled after evidence of significant leaks on follow-up TEE in 24 others (55.8%). The median leak size was 5 mm (range: 4-7 mm). On average, 18 ± 7 RF applications per patient (mean maximum contact force 16 ± 3 g, mean power 44 ± 2 W, mean RF time 5.1 ± 2.5 minutes) were performed targeting the atrial edge of the leak. Post-RF median leak size was 0 mm (range: 0-1 mm). A very low rate (2.3% [n = 1]) of major periprocedural complications was observed. Follow-up TEE revealed complete LAA sealing in 23 patients (53.5%) and negligible residual leaks in 15 (34.9%). CONCLUSIONS: RF applications targeting the atrial edge of a significant peri-Watchman leak may promote LAA sealing via tissue remodeling, without increasing complications. (RF Applications for Residual LAA Leaks [REACT]; NCT04726943).


Assuntos
Apêndice Atrial , Fibrilação Atrial , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/cirurgia , Cateterismo Cardíaco , Humanos , Estudos Prospectivos , Resultado do Tratamento
5.
J Cardiovasc Electrophysiol ; 32(9): 2441-2450, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34260115

RESUMO

BACKGROUND: Atrioesophageal fistula (AEF) is a worrisome complication of atrial fibrillation (AF) ablation. Its clinical manifestations and time course are unpredictable and may contribute to diagnostic and treatment delays. We conducted a systematic review of all available cases of AEF, aiming at characterizing clinical presentation, time course, diagnostic pitfalls, and outcomes. METHODS: The digital search retrieved 150 studies containing 257 cases, 238 (92.6%) of which with a confirmed diagnosis of AEF and 19 (7.4%) of pericardioesophageal fistula. RESULTS: The median time from ablation to symptom onset was 21 days (interquartile range [IQR]: 11-28). Neurological abnormalities were documented in 75% of patients. Compared to patients seen by a specialist, those evaluated at a walk-in clinic or community hospital had a significantly greater delay between symptom onset and hospital admission (median: 2.5 day [IQR: 1-8] vs. 1 day [IQR: 1-5); p = .03). Overall, 198 patients underwent a chest scan (computed tomography [CT]: 192 patients and magnetic resonance imaging [MRI]: 6 patients), 48 (24.2%; 46 CT and 2 MRI) of whom had normal/unremarkable findings. Time from hospital admission to diagnostic confirmation was significantly longer in patients with a first normal/unremarkable chest scan (p < .001). Overall mortality rate was 59.3% and 26.0% survivors had residual neurological deficits at the time of discharge. CONCLUSIONS: Since healthcare professionals of any specialty might be involved in treating AEF patients, awareness of the clinical manifestations, diagnostic pitfalls, and time course, as well as an early contact with the treating electrophysiologist for a coordinated interdisciplinary medical effort, are pivotal to prevent diagnostic delays and reduce mortality.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Fístula Esofágica , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Fístula Esofágica/diagnóstico por imagem , Fístula Esofágica/etiologia , Fístula Esofágica/cirurgia , Átrios do Coração/cirurgia , Humanos , Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X
6.
JACC Clin Electrophysiol ; 7(12): 1533-1543, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34217665

RESUMO

OBJECTIVES: This study sought to report the incidence of device-related thrombosis (DRT) and thromboembolic (TE) events when an alternative to clopidogrel is prescribed in loss-of-function (LOF) allele carriers of the cytochrome P450 2C19 (CYP2C19) gene. BACKGROUND: LOF polymorphisms of the CYP2C19 gene are associated with reduced hepatic bioactivation of clopidogrel. METHODS: A total of 1,002 Watchman patients were included. Six hundred forty-five patients underwent CYP2C19 genetic testing; among patients with clopidogrel resistance, clopidogrel was replaced by either prasugrel (pilot cohort) or half dose direct oral anticoagulant ([DOAC]/Group 1), both in combination with aspirin. We compared the incidence of DRT/TE events among genotyped patients and a control group which received standard dual antiplatelet therapy (DAPT) (Group 2; n = 357). All reported events occurred during a timeframe between 45- and 180-day follow-up transesophageal echocardiograms, when the 2 different antithrombotic strategies (genotype-guided vs standard DAPT) were adopted. RESULTS: In the pilot cohort (n = 244), bleeding events occurred in 10.2% of patients who received aspirin plus prasugrel, leading to early discontinuation of the prasugrel-based protocol. DOAC Group 1 patients (n = 401), 25.7% were reduced metabolizers, and clopidogrel was replaced by half dose direct oral anticoagulant. DRT was documented in 1 (0.2%) patient of Group 1 and 7 (1.96%) patients of Group 2 (log-rank P = 0.021). The composite endpoint of DRT/TE events was significantly lower among patients receiving a genotype-guided antithrombotic strategy (0.75% vs 3.10%; log-rank P = 0.017). CONCLUSIONS: In Watchman patients, a genotype-based antithrombotic strategy with aspirin plus half dose DOAC in reduced clopidogrel metabolizers was superior to standard DAPT with respect to DRT/TE events.


Assuntos
Fibrinolíticos , Trombose , Clopidogrel/efeitos adversos , Genótipo , Humanos , Incidência , Trombose/tratamento farmacológico , Trombose/epidemiologia , Trombose/genética
7.
Circ Cardiovasc Interv ; 13(10): e009227, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32942913

RESUMO

BACKGROUND: Interventional therapies aiming at excluding the left atrial appendage (LAA) from systemic circulation have been established as a valid alternative to oral anticoagulation in patients at high thromboembolic risk. However, their efficacy on stroke prophylaxis may be compromised owing to incomplete LAA closure. Additionally, the need for an alternative thromboembolic prevention may remain unmet in patients with contraindications to oral anticoagulation whose appendage anatomy is unsuitable for some conventional devices commercially available. We aimed at evaluating the feasibility of LAA closure with the novel Gore Cardioform Septal Occluder in patients with incomplete appendage ligation or anatomic features which do not meet the manufacturer's requirements for Watchman deployment. METHODS: Twenty-one consecutive patients (mean age: 72±6 years; 85.7% males; CHA2DS2-VASc: 4.5±1.4; HAS-BLED: 3.6±1.0) were included. Transesophageal echocardiography was performed within 2 months to assess for residual LAA patency. RESULTS: Fourteen patients had incomplete LAA closure following surgical (n=6) or Lariat ligation (n=8). In 7 patients with an appendage anatomy unsuitable for Watchman deployment, the mean maximal landing zone size and LAA depth were 14.4±1.3 and 18.6±2.8 mm. Successful Cardioform Septal Occluder deployment was achieved in all patients. No peri-procedural complications were documented. Procedure and fluoroscopy times were 46±13 and 14±5 minutes. Follow-up transesophageal echocardiography after 58±9 days revealed complete LAA closure in all patients. CONCLUSIONS: Transcatheter LAA closure via a Cardioform Septal Occluder device might be a valid alternative in patients with residual leaks following failed appendage ligation or whose LAA anatomy does not meet the minimal anatomic criteria to accommodate a Watchman device. Graphic Abstract: A graphic abstract is available for this article.


Assuntos
Apêndice Atrial/fisiopatologia , Fibrilação Atrial/terapia , Função do Átrio Esquerdo , Cateterismo Cardíaco/instrumentação , Dispositivo para Oclusão Septal , Tromboembolia/prevenção & controle , Idoso , Idoso de 80 Anos ou mais , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Cateterismo Cardíaco/efeitos adversos , Tomada de Decisão Clínica , Ecocardiografia Doppler em Cores , Ecocardiografia Transesofagiana , Estudos de Viabilidade , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
8.
JACC Cardiovasc Interv ; 13(3): 306-319, 2020 02 10.
Artigo em Inglês | MEDLINE | ID: mdl-31954677

RESUMO

OBJECTIVES: The aim of this study was to assess the feasibility and efficacy of transcatheter leak closure with detachable coils in patients with incomplete left atrial appendage (LAA) closure. BACKGROUND: Incomplete LAA closure is common after interventional therapies targeting the LAA, potentially hindering effective thromboembolic prevention. Detachable coils have found a wide range of applications for transcatheter vascular occlusion and embolization procedures. METHODS: Thirty consecutive patients at high thromboembolic risk with clinically relevant residual leaks (mean age 72 ± 9 years, 73.3% men, mean CHA2DS2-VASc score 4.4 ± 1.4, mean HAS-BLED score 3.6 ± 0.8) underwent percutaneous closure of the LAA patency using embolization coils. Transesophageal echocardiography was performed at 60 ± 15 days post-procedure. RESULTS: LAA closure had been previously attempted with the Watchman device in 25 patients, the Amulet device in 2 patients, and the LARIAT device in 3 patients. Baseline transesophageal echocardiography documented moderate and severe leaks in 20 (66.7%) and 10 (33.3%) patients, respectively. After a single procedure, 25 patients (83.3%) showed complete LAA sealing or minimal leaks. Five patients (16.7%) had moderate residual leaks; 3 patients of them were offered repeat procedures. Mean procedure and fluoroscopy times were 76 ± 41 min and 21 ± 14 min, respectively; the mean volume of iodinated contrast medium used was 80 ± 47 ml. Coil deployment was successful in all cases. The overall complication rate was 6.1%. After a median follow-up period of 54 days (range 43 to 265 days) and an average of 1.1 procedures/patient, transesophageal echocardiography revealed complete LAA sealing or negligible residual leaks in 28 patients (93.3%; 25 with no residual leak, 3 patients with minimal to mild residual leaks) and moderate residual leaks in 2 patients (6.7%). CONCLUSIONS: Transcatheter LAA leak occlusion using endovascular coils appears to be a safe, effective, and promising approach in patients at high echo time risk with incomplete LAA closure. (Transcatheter Leak Closure With Detachable Coils Following Incomplete Left Atrial Appendage Closure Procedures [TREASURE]; NCT03503253).


Assuntos
Apêndice Atrial , Fibrilação Atrial/terapia , Cateterismo Cardíaco/instrumentação , Embolização Terapêutica/instrumentação , Tromboembolia/prevenção & controle , Idoso , Idoso de 80 Anos ou mais , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/fisiopatologia , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Cateterismo Cardíaco/efeitos adversos , Ecocardiografia Doppler em Cores , Ecocardiografia Tridimensional , Ecocardiografia Transesofagiana , Embolização Terapêutica/efeitos adversos , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Tromboembolia/diagnóstico , Tromboembolia/etiologia , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...