Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Injury ; 48(4): 909-913, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28259379

RESUMO

A Cochrane review influenced new NICE guidelines, which recommended surgeons: Offer cemented implants to patients undergoing surgery with arthroplasty. However our trust routinely uses HAC uncemented stem (Taperloc®, Biomet) hemiarthroplasties. A review of a consecutive series of uncemented HAC stem hemiarthroplasties including measures such as intro-operative complications, mortality and revision surgery. Prospectively collected data between January 2008 and June 2014 was used, with medical record and radiographic reviews performed. 810 consecutive Taperloc uncemented hemiarthroplasty with monopolar heads were performed in 763 patients, with a minimum 12 month follow-up (12-90) follow-up. Mean age 83yrs; 71% female. Meantime to operation was 28.5h. 30day mortality: 4.4% (33/763). One year mortality was 11.2% (89/763). 2.5% (20/810) were admitted on a separate admission with the periprosthetic fracture. 0.6% (5/810) were revised to total hip replacement for subsidence and associated pain. Only 1% (8/810) had intraoperative calcar fractures, all of which were treated with intraoperative cabling with no evidence of clinically relevant subsidence or medium term complications requiring revision surgery within a year. To the author's knowledge this is largest outcome series for modern design uncemented hemiarthroplasty. Our study shows comparable data to cemented hemiarthroplasty but no deaths in the first 2days post-op. Our series also demonstrates a well below average mortality figures which are clearly multifactorial but believe uncemented prosthesis play a role. We believe that uncemented proven stem design hemiarthroplasty remains a safe and good surgical option for displaced intracapsular fractures.


Assuntos
Durapatita/uso terapêutico , Fraturas do Colo Femoral/cirurgia , Hemiartroplastia , Fraturas Periprotéticas/cirurgia , Reoperação/estatística & dados numéricos , Idoso , Idoso de 80 Anos ou mais , Austrália/epidemiologia , Materiais Biocompatíveis/uso terapêutico , Cimentos Ósseos/uso terapêutico , Cimentação/efeitos adversos , Feminino , Fraturas do Colo Femoral/mortalidade , Fraturas do Colo Femoral/fisiopatologia , Seguimentos , Hemiartroplastia/instrumentação , Hemiartroplastia/mortalidade , Prótese de Quadril , Humanos , Masculino , Fraturas Periprotéticas/mortalidade , Fraturas Periprotéticas/fisiopatologia , Guias de Prática Clínica como Assunto , Estudos Prospectivos , Reoperação/mortalidade , Resultado do Tratamento
2.
Bone Joint J ; 97-B(12): 1693-7, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26637686

RESUMO

This study aimed to determine the long-term functional, clinical and radiological outcomes in patients with Schatzker IV to VI fractures of the tibial plateau treated with an Ilizarov frame. Clinical, functional and radiological assessment was carried out at a minimum of one year post-operatively. A cohort of 105 patients (62 men, 43 women) with a mean age of 49 years (15 to 87) and a mean follow-up of 7.8 years (1 to 19) were reviewed. There were 18 type IV, 10 type V and 77 type VI fractures. All fractures united with a mean time to union of 20.1 weeks (10.6 to 42.3). No patient developed a deep infection. The median range of movement (ROM) of the knee was 110(°) and the median Iowa score was 85. Our study demonstrates good long-term functional outcome with no deep infection; spanning the knee had no detrimental effect on the ROM or functional outcome. High-energy fractures of the tibial plateau may be treated effectively with a fine wire Ilizarov fixator.


Assuntos
Fixadores Externos , Técnica de Ilizarov/instrumentação , Fraturas da Tíbia/cirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Consolidação da Fratura , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fraturas da Tíbia/diagnóstico por imagem , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Adulto Jovem
3.
Eur J Orthop Surg Traumatol ; 24(7): 1311-5, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24013812

RESUMO

Intramedullary nailing of tibial fractures is commonplace, and freehand operative techniques are increasingly popular. The standard freehand method has the knee of the injured leg flexed over a radiolucent bolster. This requires the theatre fluoroscope to swing from antero-posterior to lateral position several times. Furthermore, guide wire placement, reaming and nail insertion are all performed well above most surgeons' shoulder height. Alternatively the leg is hung over the edge of the table, and the assistant must crouch and hold the leg until the nail is passed beyond the fracture. We describe a freehand figure 4 position technique for tibial nailing which is easier both for the surgeons and the radiographer, and present a series of 87 consecutive cases utilising this method.


Assuntos
Fixação Intramedular de Fraturas/métodos , Posicionamento do Paciente , Fraturas da Tíbia/cirurgia , Pinos Ortopédicos , Ergonomia , Fluoroscopia , Humanos , Fraturas da Tíbia/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...