Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 84
Filtrar
2.
JACC Case Rep ; 29(4): 102212, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38379642

RESUMO

In a familial cohort with 8 heterozygous carriers of a rare pathogenic SCN5A mutation (c.2482C>T), 4 female mutation carriers manifested with fetal ventricular tachycardia and 2:1 atrioventricular block. One presented with multifocal ectopic premature Purkinje-related complexes-like phenotype and atrial fibrillation later in life. These novel findings inform the need for robust fetal monitoring of mutation carriers.

5.
JACC Clin Electrophysiol ; 9(12): 2558-2570, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37737773

RESUMO

BACKGROUND: Active esophageal cooling reduces the incidence of endoscopically identified severe esophageal lesions during radiofrequency (RF) catheter ablation of the left atrium for the treatment of atrial fibrillation. A formal analysis of the atrioesophageal fistula (AEF) rate with active esophageal cooling has not previously been performed. OBJECTIVES: The authors aimed to compare AEF rates before and after the adoption of active esophageal cooling. METHODS: This institutional review board (IRB)-approved study was a prospective analysis of retrospective data, designed before collecting and analyzing the real-world data. The number of AEFs occurring in equivalent time frames before and after adoption of cooling using a dedicated esophageal cooling device (ensoETM, Attune Medical) were quantified across 25 prespecified hospital systems. AEF rates were then compared using generalized estimating equations robust to cluster correlation. RESULTS: A total of 14,224 patients received active esophageal cooling during RF ablation across the 25 hospital systems, which included a total of 30 separate hospitals. In the time frames before adoption of active cooling, a total of 10,962 patients received primarily luminal esophageal temperature (LET) monitoring during their RF ablations. In the preadoption cohort, a total of 16 AEFs occurred, for an AEF rate of 0.146%, in line with other published estimates for procedures using LET monitoring. In the postadoption cohort, no AEFs were found in the prespecified sites, yielding an AEF rate of 0% (P < 0.0001). CONCLUSIONS: Adoption of active esophageal cooling during RF ablation of the left atrium for the treatment of atrial fibrillation was associated with a significant reduction in AEF rate.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Fístula Esofágica , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/complicações , Estudos Retrospectivos , Fístula Esofágica/epidemiologia , Fístula Esofágica/etiologia , Ablação por Cateter/métodos
6.
J Am Coll Cardiol ; 82(11): 1096-1105, 2023 09 12.
Artigo em Inglês | MEDLINE | ID: mdl-37673510

RESUMO

BACKGROUND: Factors determining hemodynamic stability during human ventricular tachycardia (VT) are incompletely understood. OBJECTIVES: The purposes of this study were to characterize sinus rate (SR) responses during monomorphic VT in association with hemodynamic stability and to prospectively assess the effects of vagolytic therapy on VT tolerance. METHODS: This is a retrospective analysis of patients undergoing scar-related VT ablation. Vasovagal responses were evaluated by analyzing sinus cycle length before VT induction and during VT. SR responses were classified into 3 groups: increasing (≥5 beats/min, sympathetic), decreasing (≥5 beats/min, vagal), and unchanged, with the latter 2 categorized as inappropriate SR. In a prospective cohort (n = 30) that exhibited a failure to increase SR, atropine was administered to improve hemodynamic tolerance to VT. RESULTS: In 150 patients, 261 VT episodes were analyzed (29% untolerated, 71% tolerated) with median VT duration 1.6 minutes. A total of 52% of VT episodes were associated with a sympathetic response, 31% had unchanged SR, and 17% of VTs exhibited a vagal response. A significantly higher prevalence of inappropriate SR responses was observed during untolerated VT (sustained VT requiring cardioversion within 150 seconds) compared with tolerated VT (84% vs 34%; P < 0.001). Untolerated VT was significantly different between groups: 9% (sympathetic), 82% (vagal), and 32% (unchanged) (P < 0.001). Atropine administration improved hemodynamic tolerance to VT in 70%. CONCLUSIONS: Nearly one-half of VT episodes are associated with failure to augment SR, indicative of an under-recognized pathophysiological vasovagal response to VT. Inappropriate SR responses were more predictive of hemodynamic instability than VT rate and ejection fraction. Vagolytic therapy may be a novel method to augment blood pressure during VT.


Assuntos
Taquicardia Ventricular , Humanos , Estudos Prospectivos , Estudos Retrospectivos , Taquicardia Ventricular/terapia , Hemodinâmica , Atropina/farmacologia , Ubiquitina-Proteína Ligases
7.
Circulation ; 148(18): 1354-1367, 2023 10 31.
Artigo em Inglês | MEDLINE | ID: mdl-37638389

RESUMO

BACKGROUND: The circuit boundaries for reentrant ventricular tachycardia (VT) have been historically conceptualized within a 2-dimensional (2D) construct, with their fixed or functional nature unresolved. This study aimed to examine the correlation between localized lines of conduction block (LOB) evident during baseline rhythm with lateral isthmus boundaries that 3-dimensionally constrain the VT isthmus as a hyperboloid structure. METHODS: A total of 175 VT activation maps were correlated with isochronal late activation maps during baseline rhythm in 106 patients who underwent catheter ablation for scar-related VT from 3 centers (42% nonischemic cardiomyopathy). An overt LOB was defined by a deceleration zone with split potentials (≥20 ms isoelectric segment) during baseline rhythm. A novel application of pacing within deceleration zone (≥600 ms) was implemented to unmask a concealed LOB not evident during baseline rhythm. LOB identified during baseline rhythm or pacing were correlated with isthmus boundaries during VT. RESULTS: Among 202 deceleration zones analyzed during baseline rhythm, an overt LOB was evident in 47%. When differential pacing was performed in 38 deceleration zones without overt LOB, an underlying concealed LOB was exposed in 84%. In 152 VT activation maps (2D=53, 3-dimensional [3D]=99), 69% of lateral boundaries colocalized with an LOB in 2D activation patterns, and the depth boundary during 3D VT colocalized with an LOB in 79%. In VT circuits with isthmus regions that colocalized with a U-shaped LOB (n=28), the boundary invariably served as both lateral boundaries in 2D and 3D. Overall, 74% of isthmus boundaries were identifiable as fixed LOB during baseline rhythm or differential pacing. CONCLUSIONS: The majority of VT circuit boundaries can be identified as fixed LOB from intrinsic or paced activation during sinus rhythm. Analysis of activation while pacing within the scar substrate is a novel technique that may unmask concealed LOB, previously interpreted to be functional in nature. An LOB from the perspective of a myocardial surface is frequently associated with intramural conduction, supporting the existence of a 3D hyperboloid VT circuit structure. Catheter ablation may be simplified to targeting both sides around an identified LOB during sinus rhythm.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Cicatriz , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Arritmias Cardíacas , Frequência Cardíaca/fisiologia , Bloqueio Cardíaco
8.
Am J Cardiol ; 202: 24-29, 2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-37413703

RESUMO

Catheter ablation of atrial fibrillation (CAF) is increasingly being used in the United States. This study aimed to identify variations in CAF use among Medicare beneficiaries (MBs) over a 6-year period (2013 to 2019). Using the Center of Medicare and Medicaid Services database, a 100% sample of MBs who underwent CAF from 2013 to 2019 was included. We stratified CAF use data geographically (Northeast, South, West, and Midwest) and identified the number of CAFs per 100,000 MBs, number of electrophysiologists performing CAFs per 100,000 MBs, number of CAFs per individual electrophysiologist, and average submitted charge for CAF. In addition, we stratified the data per urban versus rural areas and gender of the operator. We found that the mean atrial fibrillation (AF) prevalence, rates of CAFs, number of electrophysiologists performing CAFs, and number of CAFs per electrophysiologist have increased steadily in all regions. The mean AF prevalence was different among regions, with the highest prevalence in the Northeast (p <0.001); however, there was a pattern of higher CAFs rates in the West and the South (p ≥0.057). The number of electrophysiologists performing CAFs was not different among regions; however, the number of CAFs per electrophysiologist was higher in the West and the South (p <0.001). The average submitted charge for CAF has decreased over years and was the lowest in the West and the South (p <0.001). There was no major difference in these variables regarding operator gender. In conclusion, there are significant variations in CAF use among MBs in the United States according to geographic and urban versus rural regions. These variations have the potential to impact the outcomes in MBs diagnosed with AF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Idoso , Humanos , Estados Unidos/epidemiologia , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Fibrilação Atrial/diagnóstico , Medicare
9.
Eur Heart J Cardiovasc Imaging ; 24(2): 181-189, 2023 01 23.
Artigo em Inglês | MEDLINE | ID: mdl-36458878

RESUMO

AIMS: Although myocardial scar assessment using late gadolinium enhancement (LGE) cardiac magnetic resonance (CMR) imaging is frequently indicated for patients with implantable cardioverter defibrillators (ICDs), metal artefact can degrade image quality. With the new wideband technique designed to mitigate device related artefact, CMR is increasingly used in this population. However, the common clinical indications for CMR referral and impact on clinical decision-making and prognosis are not well defined. Our study was designed to address these knowledge gaps. METHODS AND RESULTS: One hundred seventy-nine consecutive patients with an ICD (age 59 ± 13 years, 75% male) underwent CMR using cine and wideband pulse sequences for LGE imaging. Electronic medical records were reviewed to determine the reason for CMR referral, whether there was a change in clinical decision-making, and occurrence of major adverse cardiac events (MACEs). Referral indication was the most common evaluation of ventricular tachycardia (VT) substrate (n = 114, 64%), followed by cardiomyopathy (n = 53, 30%). Overall, CMR resulted in a new or changed diagnosis in 64 (36%) patients and impacted clinical management in 51 (28%). The effect on management change was highest in patients presenting with VT. A total of 77 patients (43%) experienced MACE during the follow-up period (median 1.7 years), including 65 in patients with evidence of LGE. Kaplan-Meier analysis showed that ICD patients with LGE had worse outcomes than those without LGE (P = 0.006). CONCLUSION: The clinical yield from LGE CMR is high and provides management changing and meaningful prognostic information in a significant proportion of patients with ICDs.


Assuntos
Desfibriladores Implantáveis , Taquicardia Ventricular , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Desfibriladores Implantáveis/efeitos adversos , Meios de Contraste , Imagem Cinética por Ressonância Magnética/métodos , Gadolínio , Arritmias Cardíacas/etiologia , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/terapia , Espectroscopia de Ressonância Magnética , Valor Preditivo dos Testes
10.
Heart Rhythm O2 ; 3(3): 279-287, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35734295

RESUMO

Background: Atypical left atrial flutter (AFL) may be macroreentrant or spatially localized. The relationship between the critical isthmus (CI) for localized reentry with sinus rhythm (SR) conduction slowing has not been systematically examined. Objective: To examine the correlation between CI sites for localized AFL (L-AFL) and deceleration zones (DZ) identified by isochronal late activation mapping (ILAM) during baseline rhythm. Methods: Patients with localized AFL who underwent high-density activation mapping of both SR and AFL were retrospectively analyzed. L-AFL was defined as reentry restricted to 2 wall segments of the left atrium. CI was defined by activation mapping and sites of successful termination during ablation. DZ, defined as >3 isochrones within 1 cm radius during baseline rhythm, were correlated to the locations of the CI. Results: Thirty-one consecutive patients that underwent detailed sinus rhythm and AFL high-density activation maps were analyzed at 3 centers. A mean 4060 ± 3275 and 6209 ± 8656 points were collected in ILAM and AFL activation maps, respectively. At least 1 DZ (1.7 ± 0.77) was identified in all patients. ILAM showed 3.27 ± 0.52 isochrones per DZ (168 ± 32 ms), and co-localized to CI sites at a distance of 6.7 ± 3 mm. A total of 34% ± 14% of the AFL cycle length was contained within 0.5 cm of the DZ. Conclusions: In patients with L-AFL, CI co-localized with DZ during baseline rhythm, suggesting that DZ mapping during SR may yield candidate targets for ablation as an adjunct to pulmonary vein isolation to prevent a subtype of AFL.

12.
JACC Clin Electrophysiol ; 8(5): 651-661, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35589178

RESUMO

OBJECTIVES: This study sought to analyze the impact of the American College of Cardiology, American Heart Association, and Heart Rhythm Society (ACC/AHA/HRS) guidelines for cardiac resynchronization therapy with defibrillator (CRT-D) update on utilization and efficacy of CRT-D. BACKGROUND: In September 2012, the ACC/AHA/HRS guidelines for CRT-D were modified to include left bundle branch block (LBBB) as a Class I indication. METHODS: The IBM Watson MarketScan Database was queried between January 1, 2003, and December 31, 2018, for CRT-D implants or upgrades. The primary outcome was heart failure (HF) hospitalization following left ventricular lead implant. Secondary outcomes included all-cause mortality and device-related lead revision. RESULTS: A total of 27,238 patients were analyzed: 18,384 pre-update and 8,854 post-update. Mean age was 69 ± 11 years, 73% men, and 98% with history of HF hospitalization. The proportion of patients with LBBB increased from 29% to 55% (P < 0.001) after the update. Patients receiving CRT-D post-update demonstrated a greater prevalence of comorbidities, including atrial fibrillation (47% vs 40%; P < 0.001), diabetes mellitus (45% vs 39%; P < 0.001), chronic kidney disease (24% vs 15%; P < 0.001), and HF hospitalization in the year before CRT-D (40% vs 37%; P < 0.001). Despite greater baseline comorbidities, HF hospitalization significantly declined post-update (HR: 0.89; P < 0.001). Multivariate predictors of reduced HF hospitalization included angiotensin receptor neprilysin inhibitor prescription (HR: 0.48; P < 0.001) and presence of LBBB (HR: 0.71; P < 0.001). All-cause mortality was not significantly different between the 2 groups, and fewer lead revisions were noted post-update (0.6% vs 1.7%; P < 0.001). CONCLUSIONS: The revised 2012 guidelines led to an increased proportion of LBBB patients receiving CRT-D at the population-level. This change was associated with reduced HF hospitalization, despite broadening therapy to patients with more comorbid conditions.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Insuficiência Cardíaca , Idoso , Idoso de 80 Anos ou mais , Arritmias Cardíacas/terapia , Bloqueio de Ramo/epidemiologia , Bloqueio de Ramo/terapia , Terapia de Ressincronização Cardíaca/efeitos adversos , Desfibriladores Implantáveis/efeitos adversos , Feminino , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Seleção de Pacientes , Resultado do Tratamento , Estados Unidos/epidemiologia
14.
Heart Rhythm O2 ; 3(6Part B): 731-735, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36589010

RESUMO

Background: Transvenous lead extraction is the standard of care for cardiac implantable electronic device (CIED) malfunction/infection-related removal. However, data on its performance and results in underdeveloped countries are limited. Objective: The purpose of this study was to report the feasibility and efficacy of a lead extraction program in a tertiary hospital in Chile, South America. Methods: Patients requiring CIED removal at the Electrophysiology Division of the Hospital las Higuera's were retrospectively analyzed. Outcomes including procedure-related mortality, procedural success and failure, and cardiac and vascular complications were reported. Results: A total of 15 patients were analyzed (median age 68 [interquartile range 52-75] years; 80% male). Patients with lead extraction difficulty index >10 represented 33% of patients. Infection was the indication for removal in all patients, with pocket infection (80%). Mechanical rotational tools were used in 66% of cases, and a total of 29 leads were removed. Procedural success was accomplished in 93% of cases. There was 1 (7%) intraprocedural complication and no procedure-related mortality. Conclusions: The development of a lead management program is feasible, safe, and effective in underdeveloped countries.

15.
Heart Rhythm ; 19(4): 527-535, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34757186

RESUMO

BACKGROUND: Catheter ablation strategies for ventricular fibrillation (VF) and polymorphic ventricular tachycardia (PMVT) are not established when spontaneous triggers are rare or absent. OBJECTIVE: The purpose of this study was to report the feasibility and efficacy of a novel empiric ablation strategy of pacemapping to stored implantable cardioverter-defibrillator (ICD) template electrograms (SITE) of the clinical premature ventricular contraction (PVC) trigger. METHODS: Fifteen patients with drug-refractory VF/PMVT receiving defibrillator shocks without identifiable and mappable PVC triggers were prospectively analyzed. The protocol incorporated systematic pacemapping from known arrhythmogenic sites (moderator band/right ventricular [RV] papillary muscles, left conduction system/Purkinje network, outflow tracts) with real-time comparison between the paced ICD electrogram (EGM) morphology and SITE. RESULTS: Regions within the left Purkinje network yielded the best pacemap match for the SITE of the clinical PVC trigger in 55% of ablation targets (left posterior fascicle 6, left septal fascicle 1, left anterior fascicle 5), followed by the RV moderator band region in 14% (n = 3), RV papillary muscles in 13% (n = 3), periaortic region in 14% (n = 3), and left ventricular anterolateral papillary muscle in 4% (n = 1). Freedom from ICD therapies off antiarrhythmic drug (AAD) was 64% at 6 months and 48% at 12 months. Shock burden was reduced from 4 (2-6) to 0 (0-1) (P = .001), and use of AADs was reduced from 2 (1-2) to 0 (0-1) (P = .001). CONCLUSION: In the absence of a mappable trigger, an empiric strategy of interrogating the Purkinje network, papillary muscles, and outflow tract regions by pacemap matching with SITE of the clinical PVC is feasible to guide ablation. A significant reduction in VF/PMVT therapy burden and AAD utilization was observed after a single procedure.


Assuntos
Ablação por Cateter , Desfibriladores Implantáveis , Taquicardia Ventricular , Complexos Ventriculares Prematuros , Ablação por Cateter/métodos , Estudos de Viabilidade , Humanos , Estudos Prospectivos , Taquicardia Ventricular/cirurgia , Fibrilação Ventricular
16.
Heart Rhythm O2 ; 2(5): 446-454, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34667959

RESUMO

BACKGROUND: Although His bundle pacing (HBP) has been shown to improve left ventricular ejection fraction (LVEF), its impact on mitral regurgitation (MR) remains uncertain. OBJECTIVES: The aim of this study was to evaluate change in functional MR after HBP in patients with left ventricular (LV) systolic dysfunction. METHODS: Paired echocardiograms were retrospectively assessed in patients with reduced LVEF (<50%) undergoing HBP for pacing or resynchronization. The primary outcomes assessed were change in MR, LVEF, LV volumes, and valve geometry pre- and post-HBP. MR reduction was characterized as a decline in ≥1 MR grade post-HBP in patients with ≥grade 3 MR at baseline. RESULTS: Thirty patients were analyzed: age 68 ± 15 years, 73% male, LVEF 32% ± 10%, 38% coronary artery disease, 33% history of atrial fibrillation. Baseline QRS was 162 ± 31 ms: 33% left bundle branch block, 37% right bundle branch block, 17% paced, and 13% narrow QRS. Significant reductions in LV end-systolic volume (122 mL [73-152 mL] to 89 mL [71-122 mL], P = .006) and increase in LV ejection fraction (31% [25%-37%] to 39% [30%-49%], P < .001) were observed after HBP. Ten patients had grade 3 or 4 MR at baseline, with reduction in MR observed in 7. In patients with at least grade 3 MR at baseline, reduction in LV volumes, improved mitral valve geometry, and greater LV contractility were associated with MR reduction. Greater reduction in paced QRS width was present in MR responders compared to non-MR responders (-40% vs -25%, P = .04). CONCLUSIONS: In this initial detailed echocardiographic analysis in patients with LV systolic dysfunction, HBP reduced functional MR through favorable ventricular remodeling.

17.
Pacing Clin Electrophysiol ; 44(9): 1549-1561, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34245025

RESUMO

BACKGROUND: Cardiovascular implantable electronic device (CIED) infections are associated with significant morbidity and mortality making the identification of the causative organism critical. The vast majority of CIED infections are caused by Staphylococcal species. CIED infections associated with atypical pathogens are rare and have not been systematically investigated. The objective of this study is to characterize the clinical course, management and outcome in patients with CIED infection secondary to atypical pathogens. METHODS: Medical records of all patients who underwent CIED system extraction at the University of Chicago Medical Center between January 2010 and November 2020 were retrospectively reviewed to identify patients with CIED infection. Demographic, clinical, infection-related and outcome data were collected. CIED infections were divided into typical and atypical groups based on the pathogens isolated. RESULTS: Among 356 CIED extraction procedures, 130 (37%) were performed for CIED infection. Atypical pathogens were found in 5.4% (n = 7) and included Pantoea species (n = 2), Kocuria species (n = 1), Cutibacterium acnes (n = 1), Corynebacterium tuberculostearicum (n = 1), Corynebacterium striatum (n = 1), Stenotrophomonas maltophilia (n = 1), and Pseudozyma ahidis (n = 1). All patients with atypical CIED infections were successfully treated with total system removal and tailored antibiotic therapy. There were no infection-related deaths. CONCLUSIONS: CIED infections with atypical pathogens were rare and associated with good outcome if diagnosed early and treated with total system removal and tailored antimicrobial therapy. Atypical pathogens cultured from blood, tissue or hardware in patients with CIED infection should be considered pathogens and not contaminants.


Assuntos
Antibacterianos/uso terapêutico , Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo , Marca-Passo Artificial/efeitos adversos , Infecções Relacionadas à Prótese/microbiologia , Infecções Relacionadas à Prótese/terapia , Idoso , Terapia Combinada , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
18.
Heart Rhythm ; 18(9): 1548-1556, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33965607

RESUMO

BACKGROUND: The classical paradigm of scar-related reentrant ventricular tachycardia (VT) features a circuit with a double loop figure-of-eight (F8) activation pattern. OBJECTIVE: The purpose of this study was to interrogate VT circuits with F8 activation patterns by entrainment mapping to differentiate an active loop from a passive loop. METHODS: Sixty VT circuits with >90% of tachycardia cycle length delineated in high resolution were retrospectively analyzed in 55 patients (nonischemic 49%). A pseudo-F8 VT circuit was defined as a double loop activation pattern driven by a single loop mechanism with a passive loop that yields a long postpacing interval (postpacing interval - tachycardia cycle length ≥ 30 ms). RESULTS: Single loop activation patterns were observed in 33% (n = 20). Of 40 circuits with F8 patterns by activation mapping, 20 were studied with entrainment mapping, where a passive loop was identified by a long postpacing interval in 50%. In 6 circuits where entrainment mapping was performed from both outer loop regions, all demonstrated asymmetric responses to entrainment, confirming a single loop mechanism. Entrainment from both lateral margins of the common pathway (n = 7) demonstrated an asymmetric response in 29%. In all pseudo-F8 circuits (n = 10), the shorter loop functioned as the active loop and ablation targeting the active loop side of the isthmus resulted in VT termination with a single radiofrequency application. CONCLUSION: In a selected cohort, single loop mechanisms are more prevalent than double loop reentry in reentrant human VT. Half of VT circuits with double loop activation patterns can be demonstrated to be sustained by a single active loop mechanism by entrainment mapping. Ablation targeting the shorter active loop resulted in rapid termination during radiofrequency application.


Assuntos
Mapeamento Potencial de Superfície Corporal/métodos , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca/fisiologia , Taquicardia Ventricular/fisiopatologia , Idoso , Ablação por Cateter/métodos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Taquicardia Ventricular/cirurgia
19.
J Electrocardiol ; 66: 131-135, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33951591

RESUMO

The SCN5A gene, located on chromosome 3p21, has 28 exons and is a member of the human voltage-gated sodium channel gene family. Genetic variation in SCN5A is associated with a diverse range of phenotypes. Due to incomplete penetrance, delayed expression, inherent low signal-to-noise ratio, and marked phenotypic heterogeneity, rare novel variants in SCN5A could be misinterpreted. Hence, defining the phenotypic characteristics of these rare SCN5A variants in humans is of importance. We describe the phenotypic heterogeneity noted in 4 familial carriers of a rare, previously unreported, large deletion in exon 20 of SCN5A (c.3667-?_c.3840C +?del) and discuss the mechanisms that underlie this heterogeneity.


Assuntos
Síndrome de Brugada , Eletrocardiografia , Síndrome de Brugada/genética , Éxons/genética , Humanos , Mutação , Canal de Sódio Disparado por Voltagem NAV1.5/genética , Fenótipo
20.
Ann Noninvasive Electrocardiol ; 26(4): e12849, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33939235

RESUMO

BACKGROUND: Electrocardiographic abnormalities, such as PR interval prolongation, have been anecdotally reported in patients with aortic root abscess (ARA). An electrocardiographic marker may be useful in identifying those patients with aortic valve endocarditis who may progress to ARA. The objective of this study is to evaluate the change in the PR interval in patients with surgically confirmed ARA and compare it to age- and gender-matched controls with echocardiographically or surgically confirmed aortic valve endocarditis but without aortic root abscess and those hospitalized with diagnoses other than endocarditis. METHODS: Patients were eligible for enrollment if they were 18 years or older and were hospitalized for either ARA, aortic valve endocarditis, or for unrelated reasons and had at least one 12-lead electrocardiogram (ECG) prior to or on the day of hospitalization and at least one ECG after hospitalization but prior to any cardiac surgical procedure. Delta PR interval, defined as the difference between the pre- and post-admission PR interval, was the primary outcome of interest. The patients in the ARA group were age- and gender-matched to patients with aortic valve endocarditis and to those without endocarditis. Comparisons of demographic variables and study outcomes were performed. RESULTS: Eighteen patients with surgically confirmed ARA were enrolled. These patients were age- and gender-matched to 19 patients with aortic valve endocarditis and 18 patients with no past history or evidence of endocarditis during hospitalization. No difference was noted in the baseline PR interval between the groups. However, the PR interval following admission in the aortic root abscess group (201 ± 66 ms) was significantly longer than the PR interval in both the aortic valve endocarditis (162 ± 27 ms) (24%, p = .009) and no endocarditis (143 ± 24 ms) (40%, p < .001) groups. The primary outcome measure, delta PR interval, was significantly longer in the ARA group (35 ± 51 ms) than no endocarditis (-5 ± 17 ms) (p = .001) and aortic valve endocarditis groups (0.2 ± 18) (p = .003). CONCLUSIONS: The findings of our study support the notion that the PR interval is more likely to be prolonged in patients with ARA. Since ARA is associated with a high morbidity and mortality, PR interval prolongation in a patient with aortic valve endocarditis should prompt a thorough evaluation for aortic root involvement.


Assuntos
Endocardite , Próteses Valvulares Cardíacas , Abscesso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Eletrocardiografia , Endocardite/complicações , Endocardite/diagnóstico , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...