Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 139
Filtrar
1.
Magn Reson Med ; 2024 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-38725132

RESUMO

PURPOSE: To investigate the feasibility of diffusion tensor brain imaging at 0.55T with comparisons against 3T. METHODS: Diffusion tensor imaging data with 2 mm isotropic resolution was acquired on a cohort of five healthy subjects using both 0.55T and 3T scanners. The signal-to-noise ratio (SNR) of the 0.55T data was improved using a previous SNR-enhancing joint reconstruction method that jointly reconstructs the entire set of diffusion weighted images from k-space using shared-edge constraints. Quantitative diffusion tensor parameters were estimated and compared across field strengths. We also performed a test-retest assessment of repeatability at each field strength. RESULTS: After applying SNR-enhancing joint reconstruction, the diffusion tensor parameters obtained from 0.55T data were strongly correlated ( R 2 ≥ 0 . 70 $$ {R}^2\ge 0.70 $$ ) with those obtained from 3T data. Test-retest analysis showed that SNR-enhancing reconstruction improved the repeatability of the 0.55T diffusion tensor parameters. CONCLUSION: High-resolution in vivo diffusion MRI of the human brain is feasible at 0.55T when appropriate noise-mitigation strategies are applied.

3.
Nat Commun ; 15(1): 1309, 2024 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-38378685

RESUMO

In mice, periodic cycles of a fasting mimicking diet (FMD) protect normal cells while killing damaged cells including cancer and autoimmune cells, reduce inflammation, promote multi-system regeneration, and extend longevity. Here, we performed secondary and exploratory analysis of blood samples from a randomized clinical trial (NCT02158897) and show that 3 FMD cycles in adult study participants are associated with reduced insulin resistance and other pre-diabetes markers, lower hepatic fat (as determined by magnetic resonance imaging) and increased lymphoid to myeloid ratio: an indicator of immune system age. Based on a validated measure of biological age predictive of morbidity and mortality, 3 FMD cycles were associated with a decrease of 2.5 years in median biological age, independent of weight loss. Nearly identical findings resulted from  a second clinical study (NCT04150159). Together these results provide initial support for beneficial effects of the FMD on multiple cardiometabolic risk factors and biomarkers of biological age.


Assuntos
Dieta , Jejum , Adulto , Humanos , Animais , Camundongos , Pré-Escolar , Longevidade , Fígado/diagnóstico por imagem , Causalidade
4.
J Magn Reson Imaging ; 59(2): 412-430, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37530545

RESUMO

Cardiac MR imaging is well established for assessment of cardiovascular structure and function, myocardial scar, quantitative flow, parametric mapping, and myocardial perfusion. Despite the clear evidence supporting the use of cardiac MRI for a wide range of indications, it is underutilized clinically. Recent developments in low-field MRI technology, including modern data acquisition and image reconstruction methods, are enabling high-quality low-field imaging that may improve the cost-benefit ratio for cardiac MRI. Studies to-date confirm that low-field MRI offers high measurement concordance and consistent interpretation with clinical imaging for several routine sequences. Moreover, low-field MRI may enable specific new clinical opportunities for cardiac imaging such as imaging near metal implants, MRI-guided interventions, combined cardiopulmonary assessment, and imaging of patients with severe obesity. In this review, we discuss the recent progress in low-field cardiac MRI with a focus on technical developments and early clinical validation studies. EVIDENCE LEVEL: 5 TECHNICAL EFFICACY: Stage 1.


Assuntos
Coração , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Coração/diagnóstico por imagem , Miocárdio , Radiografia , Processamento de Imagem Assistida por Computador/métodos
5.
MAGMA ; 37(1): 1-14, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37902898

RESUMO

Contemporary whole-body low-field MRI scanners (< 1 T) present new and exciting opportunities for improved body imaging. The fundamental reason is that the reduced off-resonance and reduced SAR provide substantially increased flexibility in the design of MRI pulse sequences. Promising body applications include lung parenchyma imaging, imaging adjacent to metallic implants, cardiac imaging, and dynamic imaging in general. The lower cost of such systems may make MRI favorable for screening high-risk populations and population health research, and the more open configurations allowed may prove favorable for obese subjects and for pregnant women. This article summarizes promising body applications for contemporary whole-body low-field MRI systems, with a focus on new platforms developed within the past 5 years. This is an active area of research, and one can expect many improvements as MRI physicists fully explore the landscape of pulse sequences that are feasible, and as clinicians apply these to patient populations.


Assuntos
Coração , Imageamento por Ressonância Magnética , Gravidez , Humanos , Feminino , Imageamento por Ressonância Magnética/métodos , Coração/diagnóstico por imagem , Próteses e Implantes , Imagem Corporal Total , Pulmão/diagnóstico por imagem
6.
Magn Reson Med ; 91(4): 1464-1477, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38044680

RESUMO

PURPOSE: The reproducibility of scientific reports is crucial to advancing human knowledge. This paper is a summary of our experience in replicating a balanced SSFP half-radial dual-echo imaging technique (bSTAR) using open-source frameworks as a response to the 2023 ISMRM "repeat it with me" Challenge. METHODS: We replicated the bSTAR technique for thoracic imaging at 0.55T. The bSTAR pulse sequence is implemented in Pulseq, a vendor neutral open-source rapid sequence prototyping environment. Image reconstruction is performed with the open-source Berkeley Advanced Reconstruction Toolbox (BART). The replication of bSTAR, termed open-source bSTAR, is tested by replicating several figures from the published literature. Original bSTAR, using the pulse sequence and image reconstruction developed by the original authors, and open-source bSTAR, with pulse sequence and image reconstruction developed in this work, were performed in healthy volunteers. RESULTS: Both echo images obtained from open-source bSTAR contain no visible artifacts and show identical spatial resolution and image quality to those in the published literature. A direct head-to-head comparison between open-source bSTAR and original bSTAR on a healthy volunteer indicates that open-source bSTAR provides adequate SNR, spatial resolution, level of artifacts, and conspicuity of pulmonary vessels comparable to original bSTAR. CONCLUSION: We have successfully replicated bSTAR lung imaging at 0.55T using two open-source frameworks. Full replication of a research method solely relying on information on a research paper is unfortunately rare in research, but our success gives greater confidence that a research methodology can be indeed replicated as described.


Assuntos
Artefatos , Imageamento por Ressonância Magnética , Humanos , Reprodutibilidade dos Testes , Imageamento por Ressonância Magnética/métodos
7.
Magn Reson Med ; 91(2): 649-659, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37815020

RESUMO

PURPOSE: To develop an efficient and flexible water/fat separated real-time MRI (RT-MRI) method using spiral out-in-out-in (OIOI) sampling and balanced SSFP (bSSFP) at 0.55T. METHODS: A bSSFP sequence with golden-angle spiral OIOI readout was developed, capturing three echoes to allow water/fat separation. A low-latency reconstruction that combines all echoes was available for online visualization. An offline reconstruction provided water and fat RT-MRI in two steps: (1) image reconstruction with spatiotemporally constrained reconstruction (STCR) and (2) water/fat separation with hierarchical iterative decomposition of water and fat with echo asymmetry and least-squares estimation (HIDEAL). In healthy volunteers, spiral OIOI was acquired in the wrist during a radial-to-ulnar deviation maneuver, in the heart without breath-hold and cardiac gating, and in the lower abdomen during free-breathing for visualizing small bowel motility. RESULTS: We demonstrate successful water/fat separated RT-MRI for all tested applications. In the wrist, resulting images provided clear depiction of ligament gaps and their interactions during the radial-to-ulnar deviation maneuver. In the heart, water/fat RT-MRI depicted epicardial fat, provided improved delineation of epicardial coronary arteries, and provided high blood-myocardial contrast for ventricular function assessment. In the abdomen, water-only RT-MRI captured small bowel mobility clearly with improved water-fat contrast. CONCLUSIONS: We have demonstrated a novel and flexible bSSFP spiral OIOI sequence at 0.55T that can provide water/fat separated RT-MRI with a variety of application-specific temporal resolution and spatial resolution requirements.


Assuntos
Interpretação de Imagem Assistida por Computador , Água , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Coração , Respiração
8.
Br J Radiol ; 96(1151): 20230298, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37750944

RESUMO

OBJECTIVES: Magnetic resonance imaging (MRI) using 1.5T or 3.0T systems is routinely employed for assessing wrist pathology; however, due to off-resonance artifacts and high power deposition, these high-field systems have drawbacks for real-time (RT) imaging of the moving wrist. Recently, high-performance 0.55T MRI systems have become available. In this proof-of-concept study, we tested the hypothesis that RT-MRI during continuous, active, and uninterrupted wrist motion is feasible with a high-performance 0.55T system at temporal resolutions below 100 ms and that the resulting images provide visualization of tissues commonly interrogated for assessing dynamic wrist instability. METHODS: Participants were scanned during uninterrupted wrist radial-ulnar deviation and clenched fist maneuvers. Resulting images (nominal temporal resolution of 12.7-164.6 ms per image) were assessed for image quality. Feasibility of static MRI to supplement RT-MRI acquisition was also tested. RESULTS: The RT images with temporal resolutions < 100 ms demonstrated low distortion and image artifacts, and higher reader assessment scores. Static MRI scans showed the ability to assess anatomical structures of interest in the wrist. CONCLUSION: RT-MRI of the wrist at a high temporal resolution, coupled with static MRI, is feasible with a high-performance 0.55T system, and may enable improved assessment of wrist dynamic dysfunction and instability. ADVANCES IN KNOWLEDGE: Real-time MRI of the moving wrist is feasible with high-performance 0.55T and may improve the evaluation of dynamic dysfunction of the wrist.


Assuntos
Articulação do Punho , Punho , Humanos , Punho/diagnóstico por imagem , Articulação do Punho/diagnóstico por imagem , Movimento (Física) , Imageamento por Ressonância Magnética/métodos
9.
Nutrients ; 15(15)2023 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-37571275

RESUMO

Pediatric obesity and cardiometabolic disease disproportionately impact minority communities. Sugar reduction is a promising prevention strategy with consistent cross-sectional associations of increased sugar consumption with unfavorable biomarkers of cardiometabolic disease. Few trials have tested the efficacy of pediatric sugar reduction interventions. Therefore, in a parallel-design trial, we randomized Latino youth with obesity (BMI ≥ 95th percentile) [n = 105; 14.8 years] to control (standard diet advice) or sugar reduction (clinical intervention with a goal of ≤10% of calories from free sugar) for 12-weeks. Outcomes included changes in glucose tolerance and its determinants as assessed by a 2-h frequently sample oral glucose tolerance test, fasting serum lipid profile (total cholesterol, HDL, LDL, triglycerides, cholesterol:HDL), and inflammatory markers (CRP, IL-6, TNF-α). Free sugar intake decreased in the intervention group compared to the control group [11.5% to 7.3% vs. 13.9% to 10.7% (% Energy), respectively, p = 0.02], but there were no effects on any outcome of interest (pall > 0.07). However, an exploratory analysis revealed that sugar reduction, independent of randomization, was associated with an improved Oral-disposition index (p < 0.001), triglycerides (p = 0.049), and TNF-α (p = 0.02). Dietary sugar reduction may have the potential to reduce chronic disease risks through improvements in beta-cell function, serum triglycerides, and inflammatory markers in Latino adolescents with obesity.


Assuntos
Fatores de Risco Cardiometabólico , Doenças Cardiovasculares , Açúcares da Dieta , Adolescente , Humanos , Biomarcadores , Carboidratos , Doenças Cardiovasculares/prevenção & controle , Estudos Transversais , Hispânico ou Latino , Obesidade , Triglicerídeos , Fator de Necrose Tumoral alfa
10.
Magn Reson Med ; 90(5): 1949-1957, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37317635

RESUMO

PURPOSE: To demonstrate the feasibility of high-resolution morphologic lung MRI at 0.55 T using a free-breathing balanced steady-state free precession half-radial dual-echo imaging technique (bSTAR). METHODS: Self-gated free-breathing bSTAR (TE1 /TE2 /TR of 0.13/1.93/2.14 ms) lung imaging in five healthy volunteers and a patient with granulomatous lung disease was performed using a 0.55 T MR-scanner. A wobbling Archimedean spiral pole (WASP) trajectory was used to ensure a homogenous coverage of k-space over multiple breathing cycles. WASP uses short-duration interleaves randomly tilted by a small polar angle and rotated by a golden angle about the polar axis. Data were acquired continuously over 12:50 min. Respiratory-resolved images were reconstructed off-line using compressed sensing and retrospective self-gating. Reconstructions were performed with a nominal resolution of 0.9 mm and a reduced isotropic resolution of 1.75 mm corresponding to shorter simulated scan times of 8:34 and 4:17 min, respectively. Analysis of apparent SNR was performed in all volunteers and reconstruction settings. RESULTS: The technique provided artifact-free morphologic lung images in all subjects. The short TR of bSTAR in conjunction with a field strength of 0.55 T resulted in a complete mitigation of off-resonance artifacts in the chest. Mean SNR values in healthy lung parenchyma for the 12:50 min scan were 3.6 ± 0.8 and 24.9 ± 6.2 for 0.9 mm and 1.75 mm reconstructions, respectively. CONCLUSION: This study demonstrates the feasibility of morphologic lung MRI with a submillimeter isotropic spatial resolution in human subjects with bSTAR at 0.55 T.


Assuntos
Imageamento por Ressonância Magnética , Respiração , Humanos , Estudos Retrospectivos , Imageamento por Ressonância Magnética/métodos , Pulmão/diagnóstico por imagem
11.
Magn Reson Med ; 90(4): 1682-1694, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37345725

RESUMO

In March 2022, the first ISMRM Workshop on Low-Field MRI was held virtually. The goals of this workshop were to discuss recent low field MRI technology including hardware and software developments, novel methodology, new contrast mechanisms, as well as the clinical translation and dissemination of these systems. The virtual Workshop was attended by 368 registrants from 24 countries, and included 34 invited talks, 100 abstract presentations, 2 panel discussions, and 2 live scanner demonstrations. Here, we report on the scientific content of the Workshop and identify the key themes that emerged. The subject matter of the Workshop reflected the ongoing developments of low-field MRI as an accessible imaging modality that may expand the usage of MRI through cost reduction, portability, and ease of installation. Many talks in this Workshop addressed the use of computational power, efficient acquisitions, and contemporary hardware to overcome the SNR limitations associated with low field strength. Participants discussed the selection of appropriate clinical applications that leverage the unique capabilities of low-field MRI within traditional radiology practices, other point-of-care settings, and the broader community. The notion of "image quality" versus "information content" was also discussed, as images from low-field portable systems that are purpose-built for clinical decision-making may not replicate the current standard of clinical imaging. Speakers also described technical challenges and infrastructure challenges related to portability and widespread dissemination, and speculated about future directions for the field to improve the technology and establish clinical value.


Assuntos
Imageamento por Ressonância Magnética , Radiologia , Humanos , Imageamento por Ressonância Magnética/métodos , Software
12.
Magn Reson Med ; 90(3): 1114-1120, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37125645

RESUMO

PURPOSE: Body composition MRI captures the distribution of fat and lean tissues throughout the body, and provides valuable biomarkers of obesity, metabolic disease, and muscle disorders, as well as risk assessment. Highly reproducible protocols have been developed for 1.5T and 3T MRI. The purpose of this work was to demonstrate the feasibility and test-retest repeatability of MRI body composition profiling on a 0.55T whole-body system. METHODS: Healthy adult volunteers were scanned on a whole-body 0.55T MRI system using the integrated body RF coil. Experiments were performed to refine parameter settings such as TEs, resolution, flip angle, bandwidth, acceleration, and oversampling factors. The final protocol was evaluated using a test-retest study with subject removal and replacement in 10 adult volunteers (5 M/5F, age 25-60, body mass index 20-30). RESULTS: Compared to 1.5T and 3T, the optimal flip angle at 0.55T was higher (15°), due to the shorter T1 times, and the optimal echo spacing was larger, due to smaller chemical shift between water and fat. Overall image quality was comparable to conventional field strengths, with no significant issues with fat/water swapping or inadequate SNR. Repeatability coefficient of visceral fat, subcutaneous fat, total thigh muscle volume, muscle fat infiltration, and liver fat were 11.8 cL (2.2%), 46.9 cL (1.9%), 14.6 cL (0.5%), 0.1 pp (2%), and 0.2 pp (5%), respectively (coefficient of variation in parenthesis). CONCLUSIONS: We demonstrate that 0.55T body composition MRI is feasible and present optimized scan parameters. The resulting images provide satisfactory quality for automated post-processing and produce repeatable results.


Assuntos
Tecido Adiposo , Imageamento por Ressonância Magnética , Adulto , Humanos , Pessoa de Meia-Idade , Estudos de Viabilidade , Tecido Adiposo/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Composição Corporal , Água
13.
Pediatr Radiol ; 53(7): 1469-1475, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36882594

RESUMO

Fetal magnetic resonance imaging (MRI) is an important adjunct modality for the evaluation of fetal abnormalities. Recently, low-field MRI systems at 0.55 Tesla have become available which can produce images on par with 1.5 Tesla systems but with lower power deposition, acoustic noise, and artifact. In this article, we describe a technical innovation using low-field MRI to perform diagnostic quality fetal MRI.


Assuntos
Feto , Imageamento por Ressonância Magnética , Humanos , Feto/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Acústica , Artefatos
14.
Magn Reson Med ; 89(5): 1754-1776, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36747380

RESUMO

This review article provides an overview of developments for arterial spin labeling (ASL) perfusion imaging in the body (i.e., outside of the brain). It is part of a series of review/recommendation papers from the International Society for Magnetic Resonance in Medicine (ISMRM) Perfusion Study Group. In this review, we focus on specific challenges and developments tailored for ASL in a variety of body locations. After presenting common challenges, organ-specific reviews of challenges and developments are presented, including kidneys, lungs, heart (myocardium), placenta, eye (retina), liver, pancreas, and muscle, which are regions that have seen the most developments outside of the brain. Summaries and recommendations of acquisition parameters (when appropriate) are provided for each organ. We then explore the possibilities for wider adoption of body ASL based on large standardization efforts, as well as the potential opportunities based on recent advances in high/low-field systems and machine-learning. This review seeks to provide an overview of the current state-of-the-art of ASL for applications in the body, highlighting ongoing challenges and solutions that aim to enable more widespread use of the technique in clinical practice.


Assuntos
Encéfalo , Angiografia por Ressonância Magnética , Gravidez , Feminino , Humanos , Angiografia por Ressonância Magnética/métodos , Marcadores de Spin , Encéfalo/diagnóstico por imagem , Encéfalo/fisiologia , Imageamento por Ressonância Magnética/métodos , Perfusão , Imagem de Perfusão , Circulação Cerebrovascular/fisiologia
16.
Magn Reson Med ; 89(4): 1522-1530, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36404674

RESUMO

PURPOSE: To determine R2 and R 2 ' $$ {R}_2^{\prime } $$ transverse relaxation rates in healthy lung parenchyma at 0.55 T. This is important in that it informs the design and optimization of new imaging methods for 0.55T lung MRI. METHODS: Experiments were performed in 3 healthy adult volunteers on a prototype whole-body 0.55T MRI, using a custom free-breathing electrocardiogram-triggered, single-slice echo-shifted multi-echo spin echo (ES-MCSE) pulse sequence with respiratory navigation. Transverse relaxation rates R2 and R 2 ' $$ {R}_2^{\prime } $$ and off-resonance ∆f were jointly estimated using nonlinear least-squares estimation. These measurements were compared against R2 estimates from T2 -prepared balanced SSFP (T2 -Prep bSSFP) and R 2 * $$ {R}_2^{\ast } $$ estimates from multi-echo gradient echo, which are used widely but prone to error due to different subvoxel weighting. RESULTS: The mean R2 and R 2 ' $$ {R}_2^{\prime } $$ values of lung parenchyma obtained from ES-MCSE were 17.3 ± 0.7 Hz and 127.5 ± 16.4 Hz (T2  = 61.6 ± 1.7 ms; T 2 ' $$ {\mathrm{T}}_2^{\prime } $$  = 9.5 ms ± 1.6 ms), respectively. The off-resonance estimates ranged from -60 to 30 Hz. The R2 from T2 -Prep bSSFP was 15.7 ± 1.7 Hz (T2  = 68.6 ± 8.6 ms) and R 2 * $$ {R}_2^{\ast } $$ from multi-echo gradient echo was 131.2 ± 30.4 Hz ( T 2 * $$ {\mathrm{T}}_2^{\ast } $$  = 8.0 ± 2.5 ms). Paired t-test indicated that there is a significant difference between the proposed and reference methods (p < 0.05). The mean R2 estimate from T2 -Prep bSSFP was slightly smaller than that from ES-MCSE, whereas the mean R 2 ' $$ {R}_2^{\prime } $$ and R 2 * $$ {R}_2^{\ast } $$ estimates from ES-MCSE and multi-echo gradient echo were similar to each other across all subjects. CONCLUSIONS: Joint estimation of transverse relaxation rates and off-resonance is feasible at 0.55 T with a free-breathing electrocardiogram-gated and navigator-gated ES-MCSE sequence. At 0.55 T, the mean R2 of 17.3 Hz is similar to the reported mean R2 of 16.7 Hz at 1.5 T, but the mean R 2 ' $$ {R}_2^{\prime } $$ of 127.5 Hz is about 5-10 times smaller than that reported at 1.5 T.


Assuntos
Imageamento por Ressonância Magnética , Respiração , Adulto , Humanos , Imageamento por Ressonância Magnética/métodos , Eletrocardiografia , Pulmão/diagnóstico por imagem
17.
MAGMA ; 36(3): 419-426, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35986790

RESUMO

OBJECTIVE: Speech production MRI benefits from lower magnetic fields due to reduced off-resonance effects at air-tissue interfaces and from the use of dedicated receiver coils due to higher SNR and parallel imaging capability. Here we present a custom designed upper airway coil for 1H imaging at 0.55 Tesla and evaluate its performance in comparison with a vendor-provided prototype 16-channel head/neck coil. MATERIALS AND METHODS: Four adult volunteers were scanned with both custom speech and prototype head-neck coils. We evaluated SNR gains of each of the coils over eleven upper airway volumes-of-interest measured relative to the integrated body coil. We evaluated parallel imaging performance of both coils by computing g-factors for SENSE reconstruction of uniform and variable density Cartesian sampling schemes with R = 2, 3, and 4. RESULTS: The dedicated coil shows approximately 3.5-fold SNR efficiency compared to the head-neck coil. For R = 2 and 3, both uniform and variable density samplings have g-factor values below 1.1 in the upper airway region. For R = 4, g-factor values are higher for both trajectories. DISCUSSION: The dedicated coil configuration allows for a significant SNR gain over the head-neck coil in the articulators. This, along with favorable g values, makes the coil useful in speech production MRI.


Assuntos
Imageamento por Ressonância Magnética , Fala , Adulto , Humanos , Razão Sinal-Ruído , Imageamento por Ressonância Magnética/métodos , Cabeça , Voluntários , Imagens de Fantasmas
18.
Magn Reson Med ; 89(2): 746-755, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36198043

RESUMO

PURPOSE: To determine if contemporary 0.55 T MRI supports the use of contrast-optimal flip angles (FA) for simultaneous multi-slice (SMS) balanced SSFP (bSSFP) cardiac function assessment, which is impractical at conventional field strengths because of excessive SAR and/or banding artifacts. METHODS: Blipped-CAIPI bSSFP was combined with spiral sampling for ventricular function assessment at 0.55 T. Cine movies with single band and SMS factors of 2 and 3 (SMS 2 and 3), and FA ranging from 60° to 160°, were acquired in seven healthy volunteers. Left ventricular blood and myocardial signal intensity (SI) normalized by background noise and blood-myocardium contrast were measured and compared across acquisition settings. RESULTS: Myocardial SI was slightly higher in single band than in SMS and decreased with an increasing FA. Blood SI increased as the FA increased for single band, and increment was small for FA ≥120°. Blood SI for SMS 2 and 3 increased with an increasing FA up to ∼100°. Blood-myocardium contrast increased with an increasing FA for single band, peaked at FA = 160° (systole: 28.43, diastole: 29.15), attributed mainly to reduced myocardial SI when FA ≥120°. For SMS 2, contrast peaked at 120° (systole: 21.43, diastole: 19.85). For SMS 3, contrast peaked at 120° in systole (16.62) and 100° in diastole (19.04). CONCLUSIONS: Contemporary 0.55 T MR scanners equipped with high-performance gradient systems allow the use of contrast-optimal FA for SMS accelerated bSSFP cine examinations without compromising image quality. The contrast-optimal FA was found to be 140° to 160° for single band and 100° to 120° for SMS 2 and 3.


Assuntos
Coração , Interpretação de Imagem Assistida por Computador , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Ventrículos do Coração , Miocárdio , Imagem Cinética por Ressonância Magnética/métodos
19.
Magn Reson Med ; 88(4): 1528-1547, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35819184

RESUMO

This review article provides an overview of the current status of velocity-selective arterial spin labeling (VSASL) perfusion MRI and is part of a wider effort arising from the International Society for Magnetic Resonance in Medicine (ISMRM) Perfusion Study Group. Since publication of the 2015 consensus paper on arterial spin labeling (ASL) for cerebral perfusion imaging, important advancements have been made in the field. The ASL community has, therefore, decided to provide an extended perspective on various aspects of technical development and application. Because VSASL has the potential to become a principal ASL method because of its unique advantages over traditional approaches, an in-depth discussion was warranted. VSASL labels blood based on its velocity and creates a magnetic bolus immediately proximal to the microvasculature within the imaging volume. VSASL is, therefore, insensitive to transit delay effects, in contrast to spatially selective pulsed and (pseudo-) continuous ASL approaches. Recent technical developments have improved the robustness and the labeling efficiency of VSASL, making it a potentially more favorable ASL approach in a wide range of applications where transit delay effects are of concern. In this review article, we (1) describe the concepts and theoretical basis of VSASL; (2) describe different variants of VSASL and their implementation; (3) provide recommended parameters and practices for clinical adoption; (4) describe challenges in developing and implementing VSASL; and (5) describe its current applications. As VSASL continues to undergo rapid development, the focus of this review is to summarize the fundamental concepts of VSASL, describe existing VSASL techniques and applications, and provide recommendations to help the clinical community adopt VSASL.


Assuntos
Circulação Cerebrovascular , Angiografia por Ressonância Magnética , Angiografia por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética , Perfusão , Marcadores de Spin
20.
Magn Reson Med ; 88(2): 691-710, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35445768

RESUMO

PURPOSE: To develop and evaluate an improved strategy for compensating concomitant field effects in non-Cartesian MRI at the time of image reconstruction. THEORY: We present a higher-order reconstruction method, denoted as MaxGIRF, for non-Cartesian imaging that simultaneously corrects off-resonance, concomitant fields, and trajectory errors without requiring specialized hardware. Gradient impulse response functions are used to predict actual gradient waveforms, which are in turn used to estimate the spatiotemporally varying concomitant fields based on analytic expressions. The result, in combination with a reference field map, is an encoding matrix that incorporates a correction for all three effects. METHODS: The MaxGIRF reconstruction is applied to noiseless phantom simulations, spiral gradient-echo imaging of an International Society for Magnetic Resonance in Medicine/National Institute of Standards and Technology phantom, and axial and sagittal multislice spiral spin-echo imaging of a healthy volunteer at 0.55 T. The MaxGIRF reconstruction was compared against previously established concomitant field-compensation and image-correction methods. Reconstructed images are evaluated qualitatively and quantitatively using normalized RMS error. Finally, a low-rank approximation of MaxGIRF is used to reduce computational burden. The accuracy of the low-rank approximation is studied as a function of minimum rank. RESULTS: The MaxGIRF reconstruction successfully mitigated blurring artifacts both in phantoms and in vivo and was effective in regions where concomitant fields counteract static off-resonance, superior to the comparator method. A minimum rank of 8 and 30 for axial and sagittal scans, respectively, gave less than 2% error compared with the full-rank reconstruction. CONCLUSIONS: The MaxGIRF reconstruction simultaneously corrects off-resonance, trajectory errors, and concomitant field effects. The impact of this method is greatest when imaging with longer readouts and/or at lower field strength.


Assuntos
Algoritmos , Artefatos , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...