Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 61
Filtrar
1.
J Am Coll Radiol ; 21(6S): S126-S143, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38823941

RESUMO

Early detection of breast cancer from regular screening substantially reduces breast cancer mortality and morbidity. Multiple different imaging modalities may be used to screen for breast cancer. Screening recommendations differ based on an individual's risk of developing breast cancer. Numerous factors contribute to breast cancer risk, which is frequently divided into three major categories: average, intermediate, and high risk. For patients assigned female at birth with native breast tissue, mammography and digital breast tomosynthesis are the recommended method for breast cancer screening in all risk categories. In addition to the recommendation of mammography and digital breast tomosynthesis in high-risk patients, screening with breast MRI is recommended. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision process support the systematic analysis of the medical literature from peer reviewed journals. Established methodology principles such as Grading of Recommendations Assessment, Development, and Evaluation or GRADE are adapted to evaluate the evidence. The RAND/UCLA Appropriateness Method User Manual provides the methodology to determine the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where peer reviewed literature is lacking or equivocal, experts may be the primary evidentiary source available to formulate a recommendation.


Assuntos
Neoplasias da Mama , Detecção Precoce de Câncer , Medicina Baseada em Evidências , Sociedades Médicas , Humanos , Neoplasias da Mama/diagnóstico por imagem , Feminino , Detecção Precoce de Câncer/métodos , Estados Unidos , Mamografia/normas , Mamografia/métodos , Medição de Risco , Programas de Rastreamento/métodos
2.
J Breast Imaging ; 6(2): 141-148, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38170567

RESUMO

OBJECTIVE: To determine whether continuity of care between diagnostic breast imaging and subsequent image-guided breast biopsy could reduce patient-reported biopsy-related morbidity. METHODS: This was a prospective, pragmatically randomized, 2-arm health utilities analysis of 200 women undergoing diagnostic breast imaging followed by US- or stereotactic-guided breast biopsy at a single quaternary care center from September 3, 2019, to April 10, 2023. Breast biopsy-naive women with a BI-RADS 4 or 5 finding at diagnostic imaging were randomly scheduled for the typically first available biopsy appointment. One day after biopsy, enrolled patients were administered the Testing Morbidities Index (TMI). The primary outcome was the difference in TMI summary utility scores in patients who did vs did not have the same radiologist perform diagnostic imaging and biopsy. RESULTS: Response rates were 63% (100/159) for the different radiologist cohort and 71% (100/140) for the same radiologist cohort; all respondents answered all questions in both arms. Mean time to biopsy was 7 ± 6 days and 10 ± 9 days, and the number of participating radiologists was 11 and 18, respectively. There was no difference in individual measured domains (pain, fear, or anxiety before procedure; pain, embarrassment, fear, or anxiety during procedure; mental or physical impact after procedure; all P >.00625) or in overall patient morbidity (0.83 [95% CI, 0.81-0.85] vs 0.82 [95% CI: 0.80-0.84], P = .66). CONCLUSION: Continuity of care between diagnostic breast imaging and image-guided breast biopsy did not affect morbidity associated with breast biopsy, suggesting that patients should be scheduled for the soonest available biopsy appointment rather than waiting for the same radiologist.


Assuntos
Biópsia Guiada por Imagem , Radiologistas , Feminino , Humanos , Diagnóstico por Imagem , Morbidade , Dor , Medidas de Resultados Relatados pelo Paciente , Estudos Prospectivos
3.
Sch Psychol ; 39(2): 132-143, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38032597

RESUMO

Guided by a participatory culture-specific consultation model, this study contributes to an understanding of the effectiveness of school consultation with teachers of refugee students. The goal of the present study was to determine the impact of an individual consultation intervention with refugee teachers on their self-efficacy and self-care, in addition to their peer consultation skills. The participants were 109 teachers at refugee schools in Malaysia, most of whom were refugees (91% refugees; 73% female). Of the 109 participants, 84 teachers were coconsultants with psychology graduate students; all 109 were individual consultees. The study used a two-timepoint design with the outcomes of self-reported teacher self-care; teacher self-efficacy in the management of refugee student emotion regulation and emotional engagement; and consultation skills. Additionally, consultee-reported goal attainment, consultation effectiveness, and satisfaction were collected. The findings suggested significant latent growth from baseline to post-intervention in refugee teacher self-care and self-efficacy in the management of student emotion regulation and emotional engagement in addition to the growth of their consultation skills. The effect sizes were large for latent growth of teacher self-efficacy in promoting student emotion regulation, behavior, and emotional engagement (d = 1.19, 1.01, 1.02); the effect size for self-care was medium (d = .62). Growth was not dependent on dosage, age, gender, or consultee education, with the exception of teacher self-efficacy in management of emotional engagement which was dependent on dosage. After the intervention, the consultees reported that they completed their consultation goals at a higher level than expected, were satisfied with the consultation, and found the consultants to be helpful. The discussion situates the findings in relevant theory, research, and the culture-specific context. (PsycInfo Database Record (c) 2024 APA, all rights reserved).


Assuntos
Refugiados , Autoeficácia , Humanos , Feminino , Masculino , Autocuidado , Instituições Acadêmicas , Estudantes/psicologia
4.
J Breast Imaging ; 6(1): 53-63, 2024 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-38142230

RESUMO

OBJECTIVE: To evaluate the diagnostic performance outcomes of a breast MRI screening program in high-risk women without prior history of breast cancer. METHODS: Retrospective cohort study of 1 405 consecutive screening breast MRI examinations in 681 asymptomatic women with high risk of breast cancer without prior history of breast cancer from January 1, 2015, to December 31, 2019. Outcomes (sensitivity, specificity, positive predictive value, negative predictive value, false-negative rate [FNR], cancer detection rate [CDR]) and characteristics of cancers were determined based on histopathology or 12-month follow-up. MRI examinations performed, BI-RADS assessments, pathology outcomes, and CDRs were analyzed overall and by age decade. Results in incidence screening round (MRI in last 18 months) and nonincidence round were compared. RESULTS: Breast MRI achieved CDR 20/1000, sensitivity 93.3% (28/30), and specificity 83.4% (1 147/1375). Twenty-eight (28/1 405, CDR 20/1000) screen-detected cancers were identified: 18 (64.3%, 18/28) invasive and 10 (35.7%, 10/28) ductal carcinoma in situ. Overall, 92.9% (26/28) of all cancers were stage 0 or 1 and 89.3% (25/28) were node negative. All 14 incidence screening round malignancies were stage 0 or 1 with N0 disease. Median size for invasive carcinoma was 8.0 mm and for ductal carcinoma in situ was 9.0 mm. There were two false-negative exams for an FNR 0.1% (2/1 405). CONCLUSION: High-risk screening breast MRI was effective at detecting early breast cancer and associated with favorable outcomes.


Assuntos
Neoplasias da Mama , Carcinoma Intraductal não Infiltrante , Feminino , Humanos , Neoplasias da Mama/diagnóstico , Carcinoma Intraductal não Infiltrante/diagnóstico , Estudos Retrospectivos , Centros de Atenção Terciária , Detecção Precoce de Câncer/métodos , Imageamento por Ressonância Magnética/métodos
5.
J Am Coll Radiol ; 20(5S): S146-S163, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37236740

RESUMO

Palpable masses in women are the most common symptom associated with breast cancer. This document reviews and evaluates the current evidence for imaging recommendations of palpable masses in women less than 30 to over 40 years of age. There is also a review of several different scenarios and recommendations after initial imaging. Ultrasound is usually the appropriate initial imaging for women under 30 years of age. If ultrasound findings are suspicious or highly suggestive of malignancy (BIRADS 4 or 5), it is usually appropriate to continue with diagnostic tomosynthesis or mammography with image-guided biopsy. No further imaging is recommended if the ultrasound is benign or negative. The patient under 30 years of age with a probably benign ultrasound may undergo further imaging; however, the clinical scenario plays a role in the decision to biopsy. For women between 30 to 39 years of age, ultrasound, diagnostic mammography, tomosynthesis, and ultrasound are usually appropriate. Diagnostic mammography and tomosynthesis are the appropriate initial imaging for women 40 years of age or older, as ultrasound may be appropriate if the patient had a negative mammogram within 6 months of presentation or immediately after mammography findings are suspicious or highly suggestive of malignancy. If the diagnostic mammogram, tomosynthesis, and ultrasound findings are probably benign, no further imaging is necessary unless the clinical scenario indicates a biopsy. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision process support the systematic analysis of the medical literature from peer reviewed journals. Established methodology principles such as Grading of Recommendations Assessment, Development, and Evaluation or GRADE are adapted to evaluate the evidence. The RAND/UCLA Appropriateness Method User Manual provides the methodology to determine the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where peer reviewed literature is lacking or equivocal, experts may be the primary evidentiary source available to formulate a recommendation.


Assuntos
Neoplasias da Mama , Sociedades Médicas , Humanos , Feminino , Estados Unidos , Adulto , Pessoa de Meia-Idade , Lactente , Medicina Baseada em Evidências , Mamografia , Neoplasias da Mama/diagnóstico por imagem
6.
J Am Coll Radiol ; 19(11S): S341-S356, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36436961

RESUMO

Given that 20% to 40% of women who have percutaneous breast biopsy subsequently undergo breast surgery, knowledge of imaging women with a history of benign (including high-risk) disease or breast cancer is important. For women who had surgery for nonmalignant pathology, the surveillance recommendations are determined by their overall risk. Higher-than-average risk women with a history of benign surgery may require screening mammography starting at an earlier age before 40 and may benefit from screening MRI. For women with breast cancer who have undergone initial excision and have positive margins, imaging with diagnostic mammography or MRI can sometimes guide additional surgical planning. Women who have completed breast conservation therapy for cancer should get annual mammography and may benefit from the addition of MRI or ultrasound to their surveillance regimen. The ACR Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision process support the systematic analysis of the medical literature from peer reviewed journals. Established methodology principles such as Grading of Recommendations Assessment, Development, and Evaluation or GRADE are adapted to evaluate the evidence. The RAND/UCLA Appropriateness Method User Manual provides the methodology to determine the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances in which peer reviewed literature is lacking or equivocal, experts may be the primary evidentiary source available to formulate a recommendation.


Assuntos
Neoplasias da Mama , Mamografia , Feminino , Humanos , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/cirurgia , Neoplasias da Mama/patologia , Detecção Precoce de Câncer , Sociedades Médicas , Medicina Baseada em Evidências
8.
Acad Radiol ; 29 Suppl 1: S42-S49, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-32950384

RESUMO

OBJECTIVES: To compare radiologists' sensitivity, confidence level, and reading efficiency of detecting microcalcifications in digital breast tomosynthesis (DBT) at two clinically relevant dose levels. MATERIALS AND METHODS: Six 5-cm-thick heterogeneous breast phantoms embedded with a total of 144 simulated microcalcification clusters of four speck sizes were imaged at two dose modes by a clinical DBT system. The DBT volumes at the two dose levels were read independently by six MQSA radiologists and one fellow with 1-33 years (median 12 years) of experience in a fully-crossed counter-balanced manner. The radiologist located each potential cluster and rated its conspicuity and his/her confidence that the marked location contained a cluster. The differences in the results between the two dose modes were analyzed by two-tailed paired t-test. RESULTS: Compared to the lower-dose mode, the average glandular dose in the higher-dose mode for the 5-cm phantoms increased from 1.34 to 2.07 mGy. The detection sensitivity increased for all speck sizes and significantly for the two smaller sizes (p <0.05). An average of 13.8% fewer false positive clusters was marked. The average conspicuity rating and the radiologists' confidence level were higher for all speck sizes and reached significance (p <0.05) for the three larger sizes. The average reading time per detected cluster reduced significantly (p <0.05) by an average of 13.2%. CONCLUSION: For a 5-cm-thick breast, an increase in average glandular dose from 1.34 to 2.07 mGy for DBT imaging increased the conspicuity of microcalcifications, improved the detection sensitivity by radiologists, increased their confidence levels, reduced false positive detections, and increased the reading efficiency.


Assuntos
Neoplasias da Mama , Calcinose , Mama/diagnóstico por imagem , Calcinose/diagnóstico por imagem , Feminino , Humanos , Masculino , Mamografia/métodos , Imagens de Fantasmas , Radiologistas
9.
J Breast Imaging ; 4(1): 10-18, 2022 Jan 27.
Artigo em Inglês | MEDLINE | ID: mdl-38422412

RESUMO

Gadolinium-based contrast agents (GBCAs) have been used worldwide for over 30 years and have enabled lifesaving diagnoses. Contrast-enhanced breast MRI is frequently used as supplemental screening for women with an elevated lifetime risk of breast cancer. Data have emerged that indicate a fractional amount of administered gadolinium is retained in the bone, skin, solid organs, and brain tissues of patients with normal renal function, although there are currently no reliable data regarding the clinical or biological significance of this retention. Linear GBCAs are associated with a higher risk of gadolinium retention than macrocyclic agents. Over the course of their lives, screened women may receive high cumulative doses of GBCA. Therefore, as breast MRI screening utilization increases, thoughtful use of GBCA is indicated in this patient population.

10.
AJR Am J Roentgenol ; 217(1): 40-47, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33955776

RESUMO

OBJECTIVE. The purpose of this study was to compare breast cancer characteristics and treatment regimens among women undergoing annual versus nonannual screening mammography. MATERIALS AND METHODS. In this retrospective, institutional review board-approved, HIPAA-compliant cohort study, a breast cancer database was queried for patients who received a mammographic or clinical diagnosis of breast cancer during 2016-2017. Annual versus biennial and annual versus nonannual (biennial and triennial) mammography screening cohorts were compared using t tests or Wilcoxon rank sum tests for continuous variables and chi-square or Fisher exact tests for categoric variables. RESULTS. A total of 490 patients were diagnosed with breast cancer during 2016-2017. Among these women, 245 had an assignable screening frequency and were 40-84 years old (mean, 61.8 ± 9.9 [SD] years; median, 62 years). Screening frequency was annual for 200 of these 245 patients (81.6%), biennial for 32 (13.1%), and triennial for 13 (5.3%). Annual screening resulted in fewer late-stage presentations (AJCC stage II, III, or IV in 48 of 200 patients undergoing annual [24.0%] vs 14 of 32 undergoing biennial [43.8%; p = .02] and vs 20 of 45 undergoing nonannual screening [44.4%; p = .006]), fewer interval cancers (21 of 200 for annual [10.5%] vs 12 of 32 for biennial [37.5%; p < .001] and vs 15 of 45 for nonannual [33.3%; p < .001]), and smaller mean tumor diameter (1.4 ± 1.2 cm for annual vs 1.8 ± 1.6 cm for biennial [p = .04] and vs 1.8 ± 1.5 cm nonannual [p = .03]). Lower AJCC stage, fewer interval cancers, and smaller tumor diameter also persisted among postmenopausal women undergoing annual screening. Patients undergoing biennial and nonannual screening showed nonsignificant greater use of axillary lymph node dissection (annual, 24 of 200 [12.0%]; biennial, 6 of 32 [18.8%]; nonannual, 7 of 45 [15.6%]) and chemotherapy (annual, 55 of 200 [27.5%]; biennial, 12 of 32 [37.5%]; nonannual, 16 of 45 [35.6%]). CONCLUSION. Annual mammographic screening was associated with lower breast cancer stage and fewer interval cancers than biennial or nonannual screening.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Detecção Precoce de Câncer/métodos , Mamografia/métodos , Cooperação do Paciente/estatística & dados numéricos , Adulto , Idoso , Idoso de 80 Anos ou mais , Mama/diagnóstico por imagem , Estudos de Coortes , Bases de Dados Factuais , Feminino , Humanos , Programas de Rastreamento/métodos , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Estudos Retrospectivos , Tempo
11.
J Breast Imaging ; 3(1): 44-56, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33543122

RESUMO

OBJECTIVE: The A6702 multisite trial confirmed that apparent diffusion coefficient (ADC) measures can improve breast MRI accuracy and reduce unnecessary biopsies, but also found that technical issues rendered many lesions non-evaluable on diffusion-weighted imaging (DWI). This secondary analysis investigated factors affecting lesion evaluability and impact on diagnostic performance. METHODS: The A6702 protocol was IRB-approved at 10 institutions; participants provided informed consent. In total, 103 women with 142 MRI-detected breast lesions (BI-RADS assessment category 3, 4, or 5) completed the study. DWI was acquired at 1.5T and 3T using a four b-value, echo-planar imaging sequence. Scans were reviewed for multiple quality factors (artifacts, signal-to-noise, misregistration, and fat suppression); lesions were considered non-evaluable if there was low confidence in ADC measurement. Associations of lesion evaluability with imaging and lesion characteristics were determined. Areas under the receiver operating characteristic curves (AUCs) were compared using bootstrapping. RESULTS: Thirty percent (42/142) of lesions were non-evaluable on DWI; 23% (32/142) with image quality issues, 7% (10/142) with conspicuity and/or localization issues. Misregistration was the only factor associated with non-evaluability (P = 0.001). Smaller (≤10 mm) lesions were more commonly non-evaluable than larger lesions (p <0.03), though not significant after multiplicity correction. The AUC for differentiating benign and malignant lesions increased after excluding non-evaluable lesions, from 0.61 (95% CI: 0.50-0.71) to 0.75 (95% CI: 0.65-0.84). CONCLUSION: Image quality remains a technical challenge in breast DWI, particularly for smaller lesions. Protocol optimization and advanced acquisition and post-processing techniques would help to improve clinical utility.

12.
AJR Am J Roentgenol ; 216(4): 912-918, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33594910

RESUMO

OBJECTIVE. The purpose of this article is to evaluate whether digital mammography (DM) is associated with persistent increased detection of ductal carcinoma in situ (DCIS) or has altered the upgrade rate of DCIS to invasive cancer. MATERIALS AND METHODS. An institutional review board-approved retrospective search identified DCIS diagnosed in women with mammographic calcifications between 2001 and 2014. Ipsilateral cancer within 2 years, masses, papillary DCIS, and patients with outside imaging were excluded, yielding 484 cases. Medical records were reviewed for mammographic calcifications, technique, and pathologic diagnosis. Mammograms were interpreted by radiologists certified by the Mammography Quality Standards Act. The institution transitioned from film-screen mammography (FSM) to exclusive DM by 2010. Statistical analyses were performed using chi-square test. RESULTS. Of 484 DCIS cases, 158 (33%) were detected by FSM and 326 (67%) were detected by DM. The detection rate was higher with DM than FSM (1.4 and 0.7 per 1000, respectively; p < .001). The detection rate of high-grade DCIS doubled with DM compared with FSM (0.8 and 0.4 per 1000, respectively; p < .001). The prevalent peak of DM-detected DCIS was 2.7 per 1000 in 2008. Incident DM detection remained double FSM (1.4 vs 0.7 per 1000). Similar proportions of high-grade versus low- to intermediate-grade DCIS were detected with both modalities. There was no significant difference in the upgrade rate of DCIS to invasive cancer between DM (10%; 34/326) and FSM (10%; 15/158) (p = .74). High-grade DCIS led to 71% (35/49) of the upgrades to invasive cancer. CONCLUSION. DM was associated with a significant doubling in DCIS and high-grade DCIS detection, which persisted after prevalent peak. The majority of upgrades to invasive cancer arose from high-grade DCIS. DM was not associated with decreased upgrade to invasive cancer.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Carcinoma Intraductal não Infiltrante/diagnóstico por imagem , Mamografia , Adulto , Idoso , Idoso de 80 Anos ou mais , Mama/diagnóstico por imagem , Mama/patologia , Neoplasias da Mama/diagnóstico , Neoplasias da Mama/patologia , Carcinoma Intraductal não Infiltrante/diagnóstico , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade
13.
Radiol Clin North Am ; 59(1): 19-27, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33222997

RESUMO

Since its widespread introduction 30 years ago, screening mammography has contributed to substantial reduction in breast cancer-associated mortality, ranging from 15% to 50% in observational trials. It is currently the best examination available for the early diagnosis of breast cancer, when survival and treatment options are most favorable. However, like all medical tests and procedures, screening mammography has associated risks, including overdiagnosis and overtreatment, false-positive examinations, false-positive biopsies, and radiation exposure. Women should be aware of the benefits and risks of screening mammography in order to make the most appropriate care decisions for themselves.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mamografia/efeitos adversos , Mamografia/estatística & dados numéricos , Uso Excessivo dos Serviços de Saúde/estatística & dados numéricos , Mama/diagnóstico por imagem , Feminino , Humanos , Risco
14.
Radiology ; 298(1): 60-70, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33201788

RESUMO

Background The Eastern Cooperative Oncology Group and American College of Radiology Imaging Network Cancer Research Group A6702 multicenter trial helped confirm the potential of diffusion-weighted MRI for improving differential diagnosis of suspicious breast abnormalities and reducing unnecessary biopsies. A prespecified secondary objective was to explore the relative value of different approaches for quantitative assessment of lesions at diffusion-weighted MRI. Purpose To determine whether alternate calculations of apparent diffusion coefficient (ADC) can help further improve diagnostic performance versus mean ADC values alone for analysis of suspicious breast lesions at MRI. Materials and Methods This prospective trial (ClinicalTrials.gov identifier: NCT02022579) enrolled consecutive women (from March 2014 to April 2015) with a Breast Imaging Reporting and Data System category of 3, 4, or 5 at breast MRI. All study participants underwent standardized diffusion-weighted MRI (b = 0, 100, 600, and 800 sec/mm2). Centralized ADC measures were performed, including manually drawn whole-lesion and hotspot regions of interest, histogram metrics, normalized ADC, and variable b-value combinations. Diagnostic performance was estimated by using the area under the receiver operating characteristic curve (AUC). Reduction in biopsy rate (maintaining 100% sensitivity) was estimated according to thresholds for each ADC metric. Results Among 107 enrolled women, 81 lesions with outcomes (28 malignant and 53 benign) in 67 women (median age, 49 years; interquartile range, 41-60 years) were analyzed. Among ADC metrics tested, none improved diagnostic performance versus standard mean ADC (AUC, 0.59-0.79 vs AUC, 0.75; P = .02-.84), and maximum ADC had worse performance (AUC, 0.52; P < .001). The 25th-percentile ADC metric provided the best performance (AUC, 0.79; 95% CI: 0.70, 0.88), and a threshold using median ADC provided the greatest reduction in biopsy rate of 23.9% (95% CI: 14.8, 32.9; 16 of 67 BI-RADS category 4 and 5 lesions). Nonzero minimum b value (100, 600, and 800 sec/mm2) did not improve the AUC (0.74; P = .28), and several combinations of two b values (0 and 600, 100 and 600, 0 and 800, and 100 and 800 sec/mm2; AUC, 0.73-0.76) provided results similar to those seen with calculations of four b values (AUC, 0.75; P = .17-.87). Conclusion Mean apparent diffusion coefficient calculated with a two-b-value acquisition is a simple and sufficient diffusion-weighted MRI metric to augment diagnostic performance of breast MRI compared with more complex approaches to apparent diffusion coefficient measurement. © RSNA, 2020 Online supplemental material is available for this article.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética/métodos , Adulto , Idoso , Mama/diagnóstico por imagem , Diagnóstico Diferencial , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Sociedades Médicas , Adulto Jovem
15.
Curr Psychiatry Rep ; 22(12): 85, 2020 11 28.
Artigo em Inglês | MEDLINE | ID: mdl-33247315

RESUMO

PURPOSE OF REVIEW: The goal of this paper was to review recent literature and provide recommendations regarding the use of telemental health, with a focus on tele-consultation and tele-supervision in post-disaster and low-resource settings, including the impact of COVID-19. RECENT FINDINGS: The latest research on mental health needs in low-resource settings has identified a high need for mental health services for difficult-to-reach and underserved populations. Research on tele-consultation and tele-supervision was reviewed and found that tele-consultation and tele-supervision to be an effective modality for insuring quality mental health care delivery in low-resource settings. Additionally, two case studies were included which illustrate the use of both tele-consultation and tele-supervision in low-resource low- and middle-income settings. The paper concludes that tele-consultation and tele-supervision hold the promise to narrow the gap in quality mental health services in low-resource settings so often impacted by disaster and conflict. The authors recommend that telemental health training be developed that specifically enhances consultants' and supervisors' skills in tele-consultation and tele-supervision.


Assuntos
COVID-19 , Desastres , Consulta Remota , Humanos , Pandemias , Papel (figurativo) , SARS-CoV-2
16.
Radiology ; 297(3): 534-542, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33021891

RESUMO

Background Digital breast tomosynthesis (DBT) helps reduce recall rates and improve cancer detection compared with two-dimensional (2D) mammography but has a longer interpretation time. Purpose To evaluate the effect of DBT slab thickness and overlap on reader performance and interpretation time in the absence of 1-mm slices. Materials and Methods In this retrospective HIPAA-compliant multireader study of DBT examinations performed between August 2013 and July 2017, four fellowship-trained breast imaging radiologists blinded to final histologic findings interpreted DBT examinations by using a standard protocol (10-mm slabs with 5-mm overlap, 1-mm slices, synthetic 2D mammogram) and an experimental protocol (6-mm slabs with 3-mm overlap, synthetic 2D mammogram) with a crossover design. Among the 122 DBT examinations, 74 mammographic findings had final histologic findings, including 31 masses (26 malignant), 20 groups of calcifications (12 malignant), 18 architectural distortions (15 malignant), and five asymmetries (two malignant). Durations of reader interpretations were recorded. Comparisons were made by using receiver operating characteristic curves for diagnostic performance and paired t tests for continuous variables. Results Among 122 women, mean age was 58.6 years ± 10.1 (standard deviation). For detection of malignancy, areas under the receiver operating characteristic curves were similar between protocols (range, 0.83-0.94 vs 0.84-0.92; P ≥ .63). Mean DBT interpretation time was shorter with the experimental protocol for three of four readers (reader 1, 5.6 minutes ± 1.7 vs 4.7 minutes ± 1.4 [P < .001]; reader 2, 2.8 minutes ± 1.1 vs 2.3 minutes ± 1.0 [P = .001]; reader 3, 3.6 minutes ± 1.4 vs 3.3 minutes ± 1.3 [P = .17]; reader 4, 4.3 minutes ± 1.0 vs 3.8 minutes ± 1.1 [P ≤ .001]), with 72% reduction in both mean number of images and mean file size (P < .001 for both). Conclusion A digital breast tomosynthesis reconstruction protocol that uses 6-mm slabs with 3-mm overlap, without 1-mm slices, had similar diagnostic performance compared with the standard protocol and led to a reduced interpretation time for three of four readers. © RSNA, 2020 See also the editorial by Chang in this issue.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Competência Clínica , Mamografia/métodos , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Idoso , Detecção Precoce de Câncer/métodos , Feminino , Humanos , Pessoa de Meia-Idade , Melhoria de Qualidade , Estudos Retrospectivos
17.
Acad Radiol ; 27(12): 1734-1741, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32107123

RESUMO

RATIONALE AND OBJECTIVES: To assess for indirect evidence of gadoteridol retention in the deep brain nuclei of women undergoing serial screening breast MRI. METHODS: This HIPAA-compliant prospective observational noninferiority imaging trial was approved by the IRB. From December 2016 to March 2018, 12 consented subjects previously exposed to 0-1 doses of gadoteridol (group 1) and 7 consented subjects previously exposed to ≥4 doses of gadoteridol (group 2) prospectively underwent research-specific unenhanced brain MRI including T1w spin echo imaging and T1 mapping. Inclusion criteria were: (1) planned breast MRI with gadoteridol, (2) no gadolinium exposure other than gadoteridol, (3) able to undergo MRI, (4) no neurological illness, (5) no metastatic disease, (6) no chemotherapy. Regions of interest were manually drawn in the globus pallidus, thalamus, dentate nucleus, and pons. Globus pallidus/thalamus and dentate nucleus/pons signal intensities and T1-time ratios were calculated using established methods and correlated with cumulative gadoteridol dose (mL). RESULTS: All subjects were female (mean age: 50 ± 12 years) and previously had received an average of 0.5 ± 0.5 (group 1) and 5.9 ± 2.1 (group 2) doses of gadoteridol (cumulative dose: 8 ± 8 and 82 ± 31 mL, respectively), with the last dose an average of 492 ± 299 days prior to scanning. There was no significant correlation between cumulative gadoteridol dose (mL) and deep brain nuclei signal intensity at T1w spin echo imaging (p = 0.365-0.512) or T1 mapping (p = 0.197-0.965). CONCLUSION: We observed no indirect evidence of gadolinium retention in the deep brain nuclei of women undergoing screening breast MRI with gadoteridol.


Assuntos
Mama , Gadolínio , Imageamento por Ressonância Magnética , Compostos Organometálicos , Adulto , Mama/diagnóstico por imagem , Núcleos Cerebelares , Meios de Contraste , Feminino , Globo Pálido , Compostos Heterocíclicos , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos , Estudos Retrospectivos
18.
Radiol Imaging Cancer ; 2(2): e190037, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-33778704

RESUMO

Nuclear medicine studies are often performed in patients with breast cancer; however, incidental radiotracer uptake in the breasts can be observed in patients with nonbreast malignancies. Benign and malignant lesions can be identified on planar, SPECT, and PET scans. This review will outline the molecular and radiographic imaging appearance of benign and malignant breast lesions on sestamibi scans, bone scans, radioiodine studies, as well as PET studies using fluorine 18 (18F) fluorodeoxyglucose, gallium 68 (68Ga) tetraazacyclododecane tetraacetic acid octreotate (or DOTATATE), 68Ga prostate-specific membrane antigen, and 18F-fluciclovine radiotracers. Recognizing these lesions at molecular and anatomic imaging is important to ensure accurate diagnosis and appropriate management. Keywords: Breast, Mammography, Molecular Imaging, PET/CT, Radionuclide Studies, SPECT/CT © RSNA, 2020.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Achados Incidentais , Medicina Nuclear , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Fluordesoxiglucose F18 , Humanos , Radioisótopos do Iodo , Tomografia por Emissão de Pósitrons
19.
Clin Cancer Res ; 25(6): 1756-1765, 2019 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-30647080

RESUMO

PURPOSE: Conventional breast MRI is highly sensitive for cancer detection but prompts some false positives. We performed a prospective, multicenter study to determine whether apparent diffusion coefficients (ADCs) from diffusion-weighted imaging (DWI) can decrease MRI false positives.Experimental Design: A total of 107 women with MRI-detected BI-RADS 3, 4, or 5 lesions were enrolled from March 2014 to April 2015. ADCs were measured both centrally and at participating sites. ROC analysis was employed to assess diagnostic performance of centrally measured ADCs and identify optimal ADC thresholds to reduce unnecessary biopsies. Lesion reference standard was based on either definitive biopsy result or at least 337 days of follow-up after the initial MRI procedure. RESULTS: Of 107 women enrolled, 67 patients (median age 49, range 24-75 years) with 81 lesions with confirmed reference standard (28 malignant, 53 benign) and evaluable DWI were analyzed. Sixty-seven of 81 lesions were BI-RADS 4 (n = 63) or 5 (n = 4) and recommended for biopsy. Malignancies exhibited lower mean in centrally measured ADCs (mm2/s) than benign lesions [1.21 × 10-3 vs.1.47 × 10-3; P < 0.0001; area under ROC curve = 0.75; 95% confidence interval (CI) 0.65-0.84]. In centralized analysis, application of an ADC threshold (1.53 × 10-3 mm2/s) lowered the biopsy rate by 20.9% (14/67; 95% CI, 11.2%-31.2%) without affecting sensitivity. Application of a more conservative threshold (1.68 × 10-3 mm2/s) to site-measured ADCs reduced the biopsy rate by 26.2% (16/61) but missed three cancers. CONCLUSIONS: DWI can reclassify a substantial fraction of suspicious breast MRI findings as benign and thereby decrease unnecessary biopsies. ADC thresholds identified in this trial should be validated in future phase III studies.


Assuntos
Neoplasias da Mama/diagnóstico , Mama/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética/métodos , Interpretação de Imagem Assistida por Computador , Adulto , Idoso , Biópsia/efeitos adversos , Mama/patologia , Neoplasias da Mama/patologia , Diagnóstico Diferencial , Reações Falso-Positivas , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos , Curva ROC , Valores de Referência , Sensibilidade e Especificidade , Adulto Jovem
20.
Phys Med Biol ; 64(4): 045011, 2019 02 11.
Artigo em Inglês | MEDLINE | ID: mdl-30625429

RESUMO

The purpose of this study is to develop a new method for generating synthesized mammogram (SM) from digital breast tomosynthesis (DBT) and to assess its potential as an adjunct to DBT. We first applied multiscale bilateral filtering to the reconstructed DBT slices to enhance the high-frequency features and reduce noise. A maximum intensity projection (MIP) image was then obtained from the high-frequency components of the DBT slices. A multiscale image fusion method was designed to combine the MIP image and the central DBT projection view into an SM and further enhance the high-frequency features. We conducted a pilot reader study to visually assess the image quality of SM in comparison to full field digital mammograms (FFDM). For each DBT craniocaudal or mediolateral view, a clinical FFDM of the corresponding view was retrospectively collected. Three MQSA radiologists, blinded to the pathological and other clinical information, independently interpreted the SM and the corresponding FFDM side by side marked with the lesion locations. The differences in the BI-RADS assessments of both MCs and masses between SM and FFDM did not achieve statistical significance for all three readers. The conspicuity of MCs on SM was superior to that on FFDM and the BI-RADS assessments of MCs were comparable while the conspicuity of masses on SM was degraded and interpretation on SM was less accurate than that on FFDM. The SM may be useful for efficient prescreening of MCs in DBT but the DBT should be used for detection and characterization of masses.


Assuntos
Neoplasias da Mama/diagnóstico , Mamografia/métodos , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Neoplasias da Mama/diagnóstico por imagem , Feminino , Humanos , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...