Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
PLoS One ; 9(3): e88509, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24599325

RESUMO

The HIV/AIDS pandemic and its impact on women prompt the investigation of prevention strategies to interrupt sexual transmission of HIV. Long-acting drug delivery systems that simultaneously protect womenfrom sexual transmission of HIV and unwanted pregnancy could be important tools in combating the pandemic. We describe the design, in silico, in vitro and in vivo evaluation of a dual-reservoir intravaginal ring that delivers the HIV-1 reverse transcriptase inhibitor tenofovir and the contraceptive levonorgestrel for 90 days. Two polyether urethanes with two different hard segment volume fractions were used to make coaxial extruded reservoir segments with a 100 µm thick rate controlling membrane and a diameter of 5.5 mm that contain 1.3 wt% levonorgestrel. A new mechanistic diffusion model accurately described the levonorgestrel burst release in early time points and pseudo-steady state behavior at later time points. As previously described, tenofovir was formulated as a glycerol paste and filled into a hydrophilic polyurethane, hollow tube reservoir that was melt-sealed by induction welding. These tenofovir-eluting segments and 2 cm long coaxially extruded levonorgestrel eluting segments were joined by induction welding to form rings that released an average of 7.5 mg tenofovir and 21 µg levonorgestrel per day in vitro for 90 days. Levonorgestrel segments placed intravaginally in rabbits resulted in sustained, dose-dependent levels of levonorgestrel in plasma and cervical tissue for 90 days. Polyurethane caps placed between segments successfully prevented diffusion of levonorgestrel into the tenofovir-releasing segment during storage.Hydrated rings endured between 152 N and 354 N tensile load before failure during uniaxial extension testing. In summary, this system represents a significant advance in vaginal drug delivery technology, and is the first in a new class of long-acting multipurpose prevention drug delivery systems.


Assuntos
Dispositivos Anticoncepcionais Femininos , Infecções por HIV/prevenção & controle , Poliuretanos/química , Gravidez não Desejada , Algoritmos , Animais , Anticoncepcionais Femininos/administração & dosagem , Anticoncepcionais Femininos/farmacocinética , Sistemas de Liberação de Medicamentos , Elasticidade , Feminino , Infecções por HIV/transmissão , Humanos , Levanogestrel/administração & dosagem , Levanogestrel/farmacocinética , Modelos Teóricos , Gravidez , Coelhos , Resistência à Tração
2.
Antimicrob Agents Chemother ; 56(12): 6272-83, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23006751

RESUMO

A vaginal gel containing the antiretroviral tenofovir (TFV) recently demonstrated 39% protection against HIV infection in women. We designed and evaluated a novel reservoir TFV intravaginal ring (IVR) to potentially improve product effectiveness by providing a more controlled and sustained vaginal dose to maintain cervicovaginal concentrations. Polyurethane tubing of various hydrophilicities was filled with a high-density TFV/glycerol/water semisolid paste and then end-sealed to create IVRs. In vitro, TFV release increased with polyurethane hydrophilicity, with 35 weight percent water-swelling polyurethane IVRs achieving an approximately 10-mg/day release for 90 days with mechanical stiffness similar to that of the commercially available NuvaRing. This design was evaluated in two 90-day in vivo sheep studies for TFV pharmacokinetics and safety. Overall, TFV vaginal tissue, vaginal fluid, and plasma levels were relatively time independent over the 90-day duration at approximately 10(4) ng/g, 10(6) ng/g, and 10(1) ng/ml, respectively, near or exceeding the highest observed concentrations in a TFV 1% gel control group. TFV vaginal fluid concentrations were approximately 1,000-fold greater than levels shown to provide significant protection in women using the TFV 1% gel. There were no toxicological findings following placebo and TFV IVR treatment for 28 or 90 days, although slight to moderate increases in inflammatory infiltrates in the vaginal epithelia were observed in these animals compared to naïve animals. In summary, the controlled release of TFV from this reservoir IVR provided elevated sheep vaginal concentrations for 90 days to merit its further evaluation as an HIV prophylactic.


Assuntos
Adenina/análogos & derivados , Fármacos Anti-HIV/administração & dosagem , Fármacos Anti-HIV/uso terapêutico , Infecções por HIV/prevenção & controle , Organofosfonatos/administração & dosagem , Organofosfonatos/uso terapêutico , Adenina/administração & dosagem , Adenina/farmacocinética , Adenina/uso terapêutico , Administração Intravaginal , Animais , Fármacos Anti-HIV/farmacocinética , Cromatografia Líquida de Alta Pressão , Preparações de Ação Retardada/efeitos adversos , Desenho de Equipamento , Feminino , Irritantes , Organofosfonatos/farmacocinética , Poliuretanos , Ovinos , Tenofovir , Vagina/metabolismo , Vagina/patologia , Cremes, Espumas e Géis Vaginais
3.
J Control Release ; 163(2): 240-8, 2012 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-22981701

RESUMO

In vitro testing and quantitative analysis of a matrix, hydrophilic polyether urethane (HPEU) intravaginal ring (IVR) for sustained delivery of the anti-HIV agent tenofovir (TFV) are described. To aid in device design, we employed a pseudo-steady-state diffusion model to describe drug release, as well as an elastic mechanical model for ring compression to predict mechanical properties. TFV-HPEU IVRs of varying sizes and drug loadings were fabricated by hot-melt extrusion and injection molding. In vitro release rates of TFV were measured at 37 °C and pH 4.2 for 30 or 90 days, during which times IVR mechanical properties and swelling kinetics were monitored. Experimental data for drug release and mechanical properties were compared to model predictions. IVRs loaded with 21% TFV (w/w) released greater than 2mg TFV per day for 90 days. The diffusion model predicted 90 day release data by extrapolating forward from the first 7 days of data. Mechanical properties of IVRs were similar to NuvaRing, although the matrix elastic modulus decreased up to three-fold following hydration. This is the first vaginal dosage form to provide sustained delivery of milligram quantities of TFV for 90 days. Drug release and mechanical properties were approximated by analytical models, which may prove useful for the continuing development of IVRs for HIV prevention or other women's health indications.


Assuntos
Adenina/análogos & derivados , Fármacos Anti-HIV/química , Sistemas de Liberação de Medicamentos , Modelos Teóricos , Organofosfonatos/química , Inibidores da Transcriptase Reversa/química , Adenina/administração & dosagem , Adenina/química , Administração Intravaginal , Fármacos Anti-HIV/administração & dosagem , Interações Hidrofóbicas e Hidrofílicas , Organofosfonatos/administração & dosagem , Poliuretanos , Inibidores da Transcriptase Reversa/administração & dosagem , Tenofovir
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...