Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 59
Filtrar
1.
Clin Biomech (Bristol, Avon) ; 94: 105609, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35247697

RESUMO

BACKGROUND: Progression of plantar flexor weakness in neuromuscular diseases is usually monitored by muscle strength measurements, although they poorly relate to muscle function during walking. Pathophysiological changes such as intramuscular adipose tissue affect dynamic muscle function independent from isometric strength. Diffusion tensor imaging and T2 imaging are quantitative MRI measures reflecting muscular pathophysiological changes, and are therefore potential biomarkers to monitor plantar flexor functioning during walking in people with neuromuscular diseases. METHODS: In fourteen individuals with plantar flexor weakness diffusion tensor imaging and T2 scans of the plantar flexors were obtained, and the diffusion indices fractional anisotropy and mean diffusivity calculated. With a dynamometer, maximal isometric plantar flexor strength was measured. 3D gait analysis was used to assess maximal ankle moment and power during walking. FINDINGS: Fractional anisotropy, mean diffusivity and T2 relaxation time all moderately correlated with maximal plantar flexor strength (r > 0.512). Fractional anisotropy and mean diffusivity were not related with ankle moment or power (r < 0.288). T2 relaxation time was strongly related to ankle moment (r = -0.789) and ankle power (r = -0.798), and moderately related to maximal plantar flexor strength (r < 0.600). INTERPRETATION: In conclusion, T2 relaxation time, indicative of multiple pathophysiological changes, was strongly related to plantar flexor function during walking, while fractional anisotropy and mean diffusivity, indicative of fiber size, only related to maximal plantar flexor strength. This indicates that these measures may be suitable to monitor muscle function and gain insights into the pathophysiological changes underlying a poor plantar flexor functioning during gait in people with neuromuscular diseases.


Assuntos
Tornozelo , Doenças Neuromusculares , Imagem de Tensor de Difusão , Humanos , Imageamento por Ressonância Magnética , Músculos , Doenças Neuromusculares/diagnóstico por imagem , Caminhada/fisiologia
2.
Biomech Model Mechanobiol ; 20(3): 1101-1113, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33682028

RESUMO

For advanced tongue cancer, the choice between surgery and organ-sparing treatment is often dependent on the expected loss of tongue functionality after treatment. Biomechanical models might assist in this choice by simulating the post-treatment function loss. However, this function loss varies between patients and should, therefore, be predicted for each patient individually. In the present study, the goal was to better predict the postoperative range of motion (ROM) of the tongue by personalizing biomechanical models using diffusion-weighted MRI and constrained spherical deconvolution reconstructions of tongue muscle architecture. Diffusion-weighted MRI scans of ten healthy volunteers were obtained to reconstruct their tongue musculature, which were subsequently registered to a previously described population average or atlas. Using the displacement fields obtained from the registration, the segmented muscle fiber tracks from the atlas were morphed back to create personalized muscle fiber tracks. Finite element models were created from the fiber tracks of the atlas and those of the individual tongues. Via inverse simulation of a protruding, downward, left and right movement, the ROM of the tongue was predicted. This prediction was compared to the ROM measured with a 3D camera. It was demonstrated that biomechanical models with personalized muscles bundles are better in approaching the measured ROM than a generic model. However, to achieve this result a correction factor was needed to compensate for the small magnitude of motion of the model. Future versions of these models may have the potential to improve the estimation of function loss after treatment for advanced tongue cancer.


Assuntos
Imagem de Difusão por Ressonância Magnética , Fenômenos Ópticos , Amplitude de Movimento Articular/fisiologia , Língua/diagnóstico por imagem , Língua/fisiologia , Idoso , Fenômenos Biomecânicos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Biológicos
3.
Eur Radiol Exp ; 5(1): 8, 2021 02 10.
Artigo em Inglês | MEDLINE | ID: mdl-33565002

RESUMO

BACKGROUND: Colonic manometry is the current reference standard for assessing colonic neuromuscular function in children with intractable functional constipation (FC). Recently, cine magnetic resonance imaging (cine-MRI) has been proposed as a non-invasive alternative. We compared colonic motility patterns on cine-MRI with those obtained by manometry in children, by stimulating high-amplitude propagating contractions (HAPCs) with bisacodyl under manometric control while simultaneously acquiring cine-MRI. METHODS: After Institutional Review Board approval, adolescents with FC scheduled to undergo colonic manometry were included. A water-perfused 8-lumen catheter was used for colonic manometry recordings. After an intraluminal bisacodyl infusion, cine-MRI sequences of the descending colon were acquired for about 30 min simultaneously with colonic manometry. Manometry recordings were analysed for HAPCs. MRI images were processed with spatiotemporal motility MRI techniques. The anonymised motility results of both techniques were visually compared for the identification of HAPCs in the descending colon. RESULTS: Data regarding six patients (three males) were analysed (median age 14 years, range 12-17). After bisacodyl infusion, three patients showed a total of eleven HAPCs with colonic manometry. Corresponding cine-MRI recorded high colonic activity during two of these HAPCs, minimal activity during seven HAPCs, while two HAPCs were not recorded. In two of three patients with absent HAPCs on manometry, colonic activity was recorded with cine-MRI. CONCLUSIONS: Simultaneous acquisition of colonic cine-MRI and manometry in children with FC is feasible. Their motility results did not completely overlap in the identification of HAPCs. Research is needed to unravel the role of cine-MRI in this setting.


Assuntos
Motilidade Gastrointestinal , Imagem Cinética por Ressonância Magnética , Adolescente , Criança , Colo/diagnóstico por imagem , Constipação Intestinal/diagnóstico por imagem , Estudos de Viabilidade , Humanos , Masculino , Manometria
4.
AJNR Am J Neuroradiol ; 42(1): 109-115, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33184068

RESUMO

BACKGROUND AND PURPOSE: Although the added diagnostic value of arterial spin-labeling is shown in various cerebral pathologies, its use in clinical practice is limited. To encourage clinical adoption of ASL, we investigated the reproducibility of CBF measurements and the effects of variations in acquisition parameters compared to the recommended ASL implementation. MATERIALS AND METHODS: Thirty-four volunteers (mean age, 57.8 ± 17.0 years; range, 22-80 years) underwent two separate sessions (1.5T and 3T scanners from a single vendor) using a 15-channel head coil. Both sessions contained repeated 3D and 2D pseudocontinuous arterial spin-labeling scans using vendor-recommended acquisition parameters (recommendation paper-based), followed by three 3D pseudocontinuous arterial spin-labeling scans, two with postlabeling delays of 1600 and 2000 ms and one with increased spatial resolution. All scans were single postlabeling delay. Intrasession (identical acquisitions, scanned five minutes apart) and intersession (first 2D and 3D acquisitions of two sessions) reproducibility was examined as well as the effect of parameter variations on CBF. RESULTS: Intrasession CBF reproducibility was similar across image readouts and field strengths (within-subject coefficient of variation between 4.0% and 6.7%). Intersession within-subject coefficient of variation ranged from 6.6% to 14.8%. At 3T, the 3D acquisition with a higher spatial resolution resulted in less mixing of GM and WM signal, thus decreasing the bias in GM CBF between the 2D and 3D acquisitions (ΔCBF = 2.49 mL/100g/min [P < .001]). Postlabeling delay variations caused a modest bias (ΔCBF between -3.78 [P < .001] and 2.83 [P < .001] mL/100g/min). CONCLUSIONS: Arterial spin-labeling imaging is reproducible at both field strengths, and the reproducibility is not significantly correlated with age. Furthermore, 3T tolerates more acquisition parameter variations and allows more extensive optimizations so that 3D and 2D acquisitions can be compared.


Assuntos
Encéfalo/irrigação sanguínea , Espectroscopia de Ressonância de Spin Eletrônica/métodos , Imageamento por Ressonância Magnética/métodos , Neuroimagem/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Circulação Cerebrovascular , Feminino , Humanos , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade , Imagem de Perfusão/métodos , Reprodutibilidade dos Testes , Marcadores de Spin , Adulto Jovem
5.
Eur J Radiol ; 132: 109295, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33096502

RESUMO

OBJECTIVE: This study aimed to find the optimal acceleration factor achievable with CS-SENSE for a clinical ankle protocol while maintaining comparable image quality. METHODS: We explored the optimal acceleration achievable with factor CS-SENSE, for an ankle protocol with T2-weighted, PD-weighted TSE-Dixon (coronal, axial and sagittal) and T2-mapping (sagittal) sequences, on a 3 T MRI-scanner. This study contained three steps: (1) phantom test, (2) pilot test on healthy volunteers, (3) anatomical assessment on a cohort of healthy volunteers and a quantitative analysis. CS-SENSE images (acceleration factors between 2.0× and 12.0×) were compared to reference SENSE images (acceleration factor 2.0×). Three blinded radiologists evaluated the image quality and provided an anatomical assessment using a five-point Likert scale of 25 anatomical regions. RESULTS: The total acquisition time of the TSE-Dixon sequence was reduced by 45 % from 13'38″ to 7'37″ (acceleration factor between 3.6× and 4.0×), the T2-mapping scan time was reduced by 31 % from 5'28″ to 3'47″ (acceleration factor of 3.0×), while maintaining comparable image quality. The results from the anatomical assessment of SENSE 2.0× versus CS-SENSE 3.6× were comparable in 88.7 % as shown by the 5-point Likert scale measurements. The T2-relaxation measurements had a good correlation of ρ = 0.7 between SENSE and CS-SENSE. CONCLUSION: We found an optimum acceleration factor with CS-SENSE between 3.6× and 4.0× for TSE-Dixon and 3.0× for T2-mapping sequences in a clinical MR imaging protocol of the ankle. The total scan time was reduced by 41 % while maintaining adequate image quality.


Assuntos
Tornozelo , Imageamento Tridimensional , Aceleração , Articulação do Tornozelo , Humanos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética
6.
AJNR Am J Neuroradiol ; 41(7): 1201-1208, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32586964

RESUMO

BACKGROUND AND PURPOSE: Patients with intracranial aneurysms may benefit from 4D flow MR imaging because the derived wall shear stress is considered a useful marker for risk assessment and growth of aneurysms. However, long scan times limit the clinical implementation of 4D flow MR imaging. Therefore, this study aimed to investigate whether highly accelerated, high resolution, 4D flow MR imaging at 7T provides reliable quantitative blood flow values in intracranial arteries and aneurysms. MATERIALS AND METHODS: We used pseudospiral Cartesian undersampling with compressed sensing reconstruction to achieve high spatiotemporal resolution (0.5 mm isotropic, ∼30 ms) in a scan time of 10 minutes. We analyzed the repeatability of accelerated 4D flow scans and compared flow rates, stroke volume, and the pulsatility index with 2D flow and conventional 4D flow MR imaging in a flow phantom and 15 healthy subjects. Additionally, accelerated 4D flow MR imaging with high spatiotemporal resolution was acquired in 5 patients with aneurysms to derive wall shear stress. RESULTS: Flow-rate bias compared with 2D flow was lower for accelerated than for conventional 4D flow MR imaging (0.31 ± 0.13, P = .22, versus 0.79 ± 0.17 mL/s, P < .01). Pulsatility index bias gave similar results. Stroke volume bias showed no difference for accelerated as well as for conventional 4D flow compared to 2D flow MR imaging. Repeatability for accelerated 4D flow was similar to that of 2D flow MR imaging. Increased temporal resolution for wall shear stress measurements in 5 intracranial aneurysms did not show a consistent effect for the wall shear stress but did show an effect for the oscillatory shear index. CONCLUSIONS: Highly accelerated high spatiotemporal resolution 4D flow MR imaging at 7T in intracranial arteries and aneurysms provides repeatable and accurate quantitative flow values. Flow rate accuracy is significantly increased compared with conventional 4D flow scans.


Assuntos
Aneurisma Intracraniano/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Neuroimagem/métodos , Adulto , Circulação Cerebrovascular/fisiologia , Feminino , Voluntários Saudáveis , Hemodinâmica/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas
7.
Neth Heart J ; 28(6): 312-319, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32162204

RESUMO

BACKGROUND: Currently, no specific treatment exists for heart failure with preserved ejection fraction (HFpEF). Left ventricular (LV) relaxation during diastole is a highly energy-demanding process, while energy homeostasis is known to be compromised in HFpEF. We hypothesise that trimetazidine - a fatty acid ß­oxidation inhibitor - improves LV diastolic function in HFpEF, by altering myocardial substrate use and improving the myocardial energy status. OBJECTIVES: To assess whether trimetazidine improves LV diastolic function by improving myocardial energy metabolism in HFpEF. METHODS: The DoPING-HFpEF trial is a randomised, double-blind, placebo-controlled cross-over intervention trial comparing the efficacy of trimetazidine and placebo in 25 patients with stable HFpEF. The main inclusion criteria are: New York Heart Association functional class II to IV, LV ejection fraction ≥50%, and evidence of LV diastolic dysfunction. Patients are treated with one 20-mg trimetazidine tablet or placebo thrice daily (twice daily in the case of moderate renal dysfunction) for two periods of 3 months separated by a 2-week washout period. The primary endpoint is the change in pulmonary capillary wedge pressure during different intensities of exercise measured by right heart catheterisation. Our key secondary endpoint is the myocardial phosphocreatine (PCr)/ATP ratio measured by phosphorus-31 magnetic resonance spectroscopy and its relation to the primary endpoint. Exploratory endpoints are 6­min walk distance, N-terminal pro-brain natriuretic peptide levels, and quality of life. CONCLUSION: The DoPING-HFpEF is a phase-II trial that evaluates the effect of trimetazidine, a metabolic modulator, on diastolic function and myocardial energy status in HFpEF. [EU Clinical Trial Register: 2018-002170-52; NTR registration: NL7830].

8.
Eur Radiol ; 30(3): 1534-1543, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31776745

RESUMO

PURPOSE: To assess reliability and clinical utility of evaluating stress-related metaphyseal water distribution using a semi-quantitative Dixon MRI-based method for early diagnosis of physeal stress injuries in adolescent gymnasts. METHODS: Twenty-four gymnasts with clinically suspected overuse injury of the distal radial physis, 18 asymptomatic gymnasts, and 24 non-gymnast controls aged 12 ± 1.5 years prospectively underwent hand radiographs and 3T MRI of the wrist including coronal T1-weighted and T2-weighted Dixon sequences. Two raters measured metaphyseal water signal fraction in 13 radial and ulnar regions of interest (ROI). Inter- and intrarater reliability, interslice (between 3 middle radial slices), and inter-ROI (between 3 ROIs on same level) reliability were assessed using intraclass correlation coefficients (ICC). Water signal fractions and their within-person ratios in distal versus most proximal ROIs were compared between groups using one-way analysis of variance. RESULTS: Inter- and intrarater ICCs were 0.79-0.99 and 0.94-1.0 for T1-weighted, and 0.88-1.0 and 0.88-1.0 for T2-weighted Dixon. Interslice and inter-ROI ICCs were 0.55-0.94 and 0.95-0.97 for T1-weighted, and 0.70-0.96 and 0.96-0.97 for T2-weighted Dixon. Metaphyseal water signal fraction in symptomatic gymnasts was higher in six distal ROIs compared with asymptomatic gymnasts and in nine ROIs compared with non-gymnasts (p < 0.05). Metaphyseal water score (ratio of distal versus most proximal ROIs) was 1.61 in symptomatic gymnasts and 1.35 in asymptomatic gymnasts on T2-weighted Dixon (p < 0.05). CONCLUSION: Semi-quantitative Dixon MRI-based water signal fraction assessment has good to excellent reproducibility and shows increased metaphyseal water scores in symptomatic gymnasts compared with asymptomatic gymnastic peers. KEY POINTS: • The proposed Dixon MRI-based semi-quantitative method for assessment of metaphyseal bone marrow water content is reliable, with off-the-shelf availability and short scan times. • The metaphyseal water score allows comparisons between gymnasts using a within-person reference area for unaffected metaphyseal bone. • As metaphyseal water score was increased in symptomatic gymnasts compared with asymptomatic gymnasts, this semi-quantitative method can potentially be used as an indicator of bone marrow edema in the early diagnosis of gymnastic physeal stress injury.


Assuntos
Medula Óssea/patologia , Edema/diagnóstico , Ginástica , Imageamento por Ressonância Magnética/métodos , Articulação do Punho/patologia , Adolescente , Criança , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes
9.
Eur Radiol Exp ; 3(1): 7, 2019 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-30725241

RESUMO

BACKGROUND: To investigate the feasibility of compressed sensing and parallel imaging (CS-PI)-accelerated bowel motility magnetic resonance imaging (MRI) and to compare its image quality and diagnostic quality to conventional sensitivity encoding (SENSE) accelerated scans. METHODS: Bowel MRI was performed in six volunteers using a three-dimensional balanced fast field-echo sequence. Static scans were performed after the administration of a spasmolytic agent to prevent bowel motion artefacts. Fully sampled reference scans and multiple prospectively 3× to 7× undersampled CS-PI and SENSE scans were acquired. Additionally, fully sampled CS-PI and SENSE scans were retrospectively undersampled and reconstructed. Dynamic scans were performed using 5× to 7× accelerated scans in the presence of bowel motion. Retrospectively, undersampled scans were compared to fully sampled scans using structural similarity indices. All reconstructions were visually assessed for image quality and diagnostic quality by two radiologists. RESULTS: For static imaging, the performance of CS-PI was lower than that of fully sampled and SENSE scans: the diagnostic quality was assessed as adequate or good for 100% of fully sampled scans, 95% of SENSE, but only for 55% of CS-PI scans. For dynamic imaging, CS-PI image quality was scored similar to SENSE at high acceleration. Diagnostic quality of all scans was scored as adequate or good; 55% of CS-PI and 83% of SENSE scans were scored as good. CONCLUSION: Compared to SENSE, current implementation of CS-PI performed less or equally good in terms of image quality and diagnostic quality. CS-PI did not show advantages over SENSE for three-dimensional bowel motility imaging.

10.
Eur Radiol ; 29(3): 1444-1451, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30132105

RESUMO

BACKGROUND: With the implementation of transcatheter aortic valve replacement (TAVR) in lower-risk patients, evaluation of blood flow characteristics and the effect of TAVR on aortic dilatation becomes of considerable interest. We employed 4D flow MRI in the ascending aorta of patients after TAVR to assess wall shear stress (WSS) and compare blood flow patterns with surgical aortic valve replacement (SAVR) and age- and gender-matched controls. METHODS: Fourteen post-TAVR patients and ten age- and gender-matched controls underwent kt-PCA accelerated 4D flow MRI of the thoracic aorta at 3.0 Tesla. Velocity and wall shear stress was compared between the two groups. In addition, aortic flow eccentricity and displacement was assessed and compared between TAVR patients, controls and 14 SAVR patients recruited as part of an earlier study. RESULTS: Compared to controls, abnormally elevated WSS was present in 30±10% of the ascending aortic wall in TAVR patients. Increased WSS was present along the posterior mid-ascending aorta and the anterior distal-ascending aorta in all TAVR patients. TAVR results in eccentric and displaced flow in the mid- and distal-ascending aorta, whereas blood flow displacement in SAVR patients occurs only in the distal-ascending aorta. CONCLUSION: This study shows that TAVR results in increased blood flow velocity and WSS in the ascending aorta compared to age- and gender-matched elderly controls. This finding warrants longitudinal assessment of aortic dilatation after TAVR in the era of potential TAVR in lower-risk patients. Additionally, TAVR results in altered blood flow eccentricity and displacement in the mid- and distal-ascending aorta, whereas SAVR only results in altered blood flow eccentricity and displacement in the distal-ascending aorta. KEY POINTS: • TAVR results in increased blood flow velocity and WSS in the ascending aorta. • Longitudinal assessment of aortic dilatation after TAVR is warranted in the era of potential TAVR in lower-risk patients. • Both TAVR and SAVR result in altered blood flow patterns in the ascending aorta when compared to age-matched controls.


Assuntos
Aorta/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Velocidade do Fluxo Sanguíneo/fisiologia , Próteses Valvulares Cardíacas , Imageamento por Ressonância Magnética/métodos , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Aorta/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/fisiopatologia , Feminino , Humanos , Masculino , Estresse Mecânico
11.
BMC Cancer ; 18(1): 1006, 2018 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-30342494

RESUMO

BACKGROUND: Nearly one third of patients undergoing neoadjuvant chemoradiotherapy (nCRT) for locally advanced esophageal cancer have a pathologic complete response (pCR) of the primary tumor upon histopathological evaluation of the resection specimen. The primary aim of this study is to develop a model that predicts the probability of pCR to nCRT in esophageal cancer, based on diffusion-weighted magnetic resonance imaging (DW-MRI), dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) and 18F-fluorodeoxyglucose positron emission tomography with computed tomography (18F-FDG PET-CT). Accurate response prediction could lead to a patient-tailored approach with omission of surgery in the future in case of predicted pCR or additional neoadjuvant treatment in case of non-pCR. METHODS: The PRIDE study is a prospective, single arm, observational multicenter study designed to develop a multimodal prediction model for histopathological response to nCRT for esophageal cancer. A total of 200 patients with locally advanced esophageal cancer - of which at least 130 patients with adenocarcinoma and at least 61 patients with squamous cell carcinoma - scheduled to receive nCRT followed by esophagectomy will be included. The primary modalities to be incorporated in the prediction model are quantitative parameters derived from MRI and 18F-FDG PET-CT scans, which will be acquired at fixed intervals before, during and after nCRT. Secondary modalities include blood samples for analysis of the presence of circulating tumor DNA (ctDNA) at 3 time-points (before, during and after nCRT), and an endoscopy with (random) bite-on-bite biopsies of the primary tumor site and other suspected lesions in the esophagus as well as an endoscopic ultrasonography (EUS) with fine needle aspiration of suspected lymph nodes after finishing nCRT. The main study endpoint is the performance of the model for pCR prediction. Secondary endpoints include progression-free and overall survival. DISCUSSION: If the multimodal PRIDE concept provides high predictive performance for pCR, the results of this study will play an important role in accurate identification of esophageal cancer patients with a pCR to nCRT. These patients might benefit from a patient-tailored approach with omission of surgery in the future. Vice versa, patients with non-pCR might benefit from additional neoadjuvant treatment, or ineffective therapy could be stopped. TRIAL REGISTRATION: The article reports on a health care intervention on human participants and was prospectively registered on March 22, 2018 under ClinicalTrials.gov Identifier: NCT03474341 .


Assuntos
Quimiorradioterapia/métodos , Neoplasias Esofágicas/diagnóstico por imagem , Neoplasias Esofágicas/terapia , Terapia Neoadjuvante/métodos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Cuidados Pré-Operatórios/métodos , Neoplasias Esofágicas/epidemiologia , Seguimentos , Humanos , Resultado do Tratamento
12.
NMR Biomed ; 31(10): e3932, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29846986

RESUMO

This review on magnetic resonance elastography (MRE) of the breast provides an overview of available literature and describes current developments in the field of breast MRE, including new transducer technology for data acquisition and multi-frequency-derived power-law behaviour of tissue. Moreover, we discuss the future potential of breast MRE, which goes beyond its original application as an additional tool in differentiating benign from malignant breast lesions. These areas of ongoing and future research include MRE for pre-operative tumour delineation, staging, monitoring and predicting response to treatment, as well as prediction of the metastatic potential of primary tumours.


Assuntos
Mama/diagnóstico por imagem , Técnicas de Imagem por Elasticidade , Imageamento por Ressonância Magnética , Módulo de Elasticidade , Humanos , Publicações
13.
AJNR Am J Neuroradiol ; 39(5): 910-915, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29599169

RESUMO

BACKGROUND AND PURPOSE: Hemodynamics are thought to play a role in intracranial aneurysm growth and rupture. Computational fluid dynamics is frequently performed to assess intra-aneurysmal hemodynamics, using generalized flow waveforms of healthy volunteers as inflow boundary conditions. The purpose of this study was to assess differences in inflow conditions for different aneurysmal parent artery locations and variations of circle of Willis configurations. MATERIALS AND METHODS: In a series of 96 patients with 103 aneurysms, velocity measurements were acquired using 2D phase-contrast MR imaging perpendicular to the aneurysmal parent arteries in the circle of Willis. Circle of Willis configurations were inspected for variations using multiple overlapping thin-slab-acquisition MRAs. Flow rates, velocity magnitudes, and pulsatility indices were calculated for each parent artery location in subgroups of complete and incomplete circle of Willis configurations. RESULTS: Flow rates, velocity magnitudes, and pulsatility indices were significantly different among aneurysmal parent arteries. Incomplete circle of Willis configurations were observed in 24% of the cases. Significantly lower basilar artery flow rates were observed in configurations with hypoplastic P1 segments. Significantly higher A1 flow rates were observed in configurations with a hypoplastic contralateral A1 segment. CONCLUSIONS: Inflow conditions vary substantially between aneurysmal parent arteries and circle of Willis configurations. We have created a collection of parent artery-specific inflow conditions tailored to the patient-specific circle of Willis configuration that can be used in future computational fluid dynamics studies analyzing intra-aneurysmal hemodynamics.


Assuntos
Circulação Cerebrovascular/fisiologia , Círculo Arterial do Cérebro/fisiopatologia , Hemodinâmica/fisiologia , Aneurisma Intracraniano/fisiopatologia , Adulto , Idoso , Círculo Arterial do Cérebro/patologia , Feminino , Humanos , Hidrodinâmica , Aneurisma Intracraniano/patologia , Masculino , Pessoa de Meia-Idade
14.
Int J Obes (Lond) ; 42(2): 156-162, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-28811653

RESUMO

BACKGROUND: Several human and rodent studies suggest that in addition to the amount of energy consumed, timing of food intake contributes to body weight regulation. Consuming most energy in the morning has favorable effects on weight loss and weight maintenance. Whether this also affects glucose metabolism and liver fat independently from weight loss is unknown. OBJECTIVE: We hypothesized that during weight loss, consuming most energy in the morning improves insulin sensitivity and reduces hepatic fat content more than consuming most energy in the evening. METHODS: Twenty-three obese insulin resistant men (age 59.9±7.9 years, body mass index 34.4±3.8 kg m-2) followed a 4-week hypocaloric diet intervention with either 50% of daily energy consumed in the morning (BF group) or evening (D group). Insulin sensitivity, measured with a two-step hyperinsulinemic euglycemic clamp using a glucose tracer, intrahepatic triglycerides (IHTG), measured using magnetic resonance spectroscopy, and resting energy expenditure (REE) were assessed before and after the diet intervention. RESULTS: Meal macronutrient composition and weight loss (6.5±1.5% vs 6.2±1.9%, respectively, P=0.70) did not differ between the BF and D groups. Endogenous glucose production (P⩽0.001), hepatic and peripheral insulin sensitivity (P=0.002; P=0.001, respectively) as well as IHTG content (P⩽0.001) all significantly improved with weight loss, but were not different between the BF and D groups. In addition, both groups decreased REE and respiratory quotient equally. CONCLUSIONS: During weight loss, consuming most energy in the morning instead of the evening does not have additional beneficial effects on insulin sensitivity and IHTG content. These results do not support weight independent effects of meal timing on glucose metabolism and IHTG in hypocaloric conditions in obese men.


Assuntos
Glicemia/metabolismo , Resistência à Insulina/fisiologia , Fígado/metabolismo , Refeições , Obesidade/metabolismo , Triglicerídeos/metabolismo , Redução de Peso/fisiologia , Idoso , Dieta Redutora , Ingestão de Energia/fisiologia , Metabolismo Energético/fisiologia , Técnica Clamp de Glucose , Humanos , Fígado/diagnóstico por imagem , Espectroscopia de Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Obesidade/prevenção & controle , Resultado do Tratamento
15.
Artigo em Inglês | MEDLINE | ID: mdl-29265641

RESUMO

Dynamic magnetic resonance imaging (MRI) of gastrointestinal motility has developed rapidly over the past few years. The non-invasive and non-ionizing character of MRI is an important advantage together with the fact that it is fast and can visualize the entire gastrointestinal tract. Advances in imaging and quantification techniques have facilitated assessment of gastric, small intestinal, and colonic motility in a clinical setting. Automated quantitative motility assessment using dynamic MRI meets the need for non-invasive techniques. Recently, studies have begun to examine this technique in patients, including those with IBD, pseudo-obstruction and functional bowel disorders. Remaining challenges for clinical implementation are processing the large amount of data, standardization and validation of the numerous MRI metrics and subsequently assessment of the potential role of dynamic MRI. This review examines the methods, advances, and remaining challenges of evaluation of gastrointestinal motility with MRI. It accompanies an article by Khalaf et al. in this journal that describes a new protocol for assessment of pan-intestinal motility in fasted and fed state in a single MRI session.


Assuntos
Gastroenteropatias/diagnóstico por imagem , Motilidade Gastrointestinal , Trato Gastrointestinal/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética/métodos , Doença de Crohn/diagnóstico por imagem , Humanos , Pseudo-Obstrução Intestinal/diagnóstico por imagem , Síndrome do Intestino Irritável/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética/tendências
16.
Psychol Med ; 47(16): 2854-2865, 2017 12.
Artigo em Inglês | MEDLINE | ID: mdl-28552082

RESUMO

BACKGROUND: Phenylketonuria (PKU), a genetic metabolic disorder that is characterized by the inability to convert phenylalanine to tyrosine, leads to severe intellectual disability and other cerebral complications if left untreated. Dietary treatment, initiated soon after birth, prevents most brain-related complications. A leading hypothesis postulates that a shortage of brain monoamines may be associated with neurocognitive deficits that are observable even in early-treated PKU. However, there is a paucity of evidence as yet for this hypothesis. METHODS: We therefore assessed in vivo striatal dopamine D2/3 receptor (D2/3R) availability and plasma monoamine metabolite levels together with measures of impulsivity and executive functioning in 18 adults with PKU and average intellect (31.2 ± 7.4 years, nine females), most of whom were early and continuously treated. Comparison data from 12 healthy controls that did not differ in gender and age were available. RESULTS: Mean D2/3R availability was significantly higher (13%; p = 0.032) in the PKU group (n = 15) than in the controls, which may reflect reduced synaptic brain dopamine levels in PKU. The PKU group had lower plasma levels of homovanillic acid (p < 0.001) and 3-methoxy-4-hydroxy-phenylglycol (p < 0.0001), the predominant metabolites of dopamine and norepinephrine, respectively. Self-reported impulsivity levels were significantly higher in the PKU group compared with healthy controls (p = 0.033). Within the PKU group, D2/3R availability showed a positive correlation with both impulsivity (r = 0.72, p = 0.003) and the error rate during a cognitive flexibility task (r = 0.59, p = 0.020). CONCLUSIONS: These findings provide further support for the hypothesis that executive functioning deficits in treated adult PKU may be associated with cerebral dopamine deficiency.


Assuntos
Monoaminas Biogênicas/sangue , Encéfalo/metabolismo , Transtornos Cognitivos/sangue , Dopamina/deficiência , Fenilcetonúrias/psicologia , Adolescente , Adulto , Estudos de Casos e Controles , Cognição , Transtornos Cognitivos/etiologia , Função Executiva , Feminino , Humanos , Comportamento Impulsivo , Estudos Longitudinais , Masculino , Testes Neuropsicológicos , Fenilalanina/sangue , Fenilcetonúrias/sangue , Fenilcetonúrias/complicações , Receptores de Dopamina D2/metabolismo , Adulto Jovem
17.
Ned Tijdschr Geneeskd ; 160: D337, 2016.
Artigo em Holandês | MEDLINE | ID: mdl-27531248

RESUMO

Five years ago, we reported on the use of 1H-magnetic resonance spectroscopy (MRS-PDFF) as a non-invasive means of determining the amount of liver fat. Liver biopsy, the current reference method, has several shortcomings (e.g. risk of complications and large interobserver variability), which are less pronounced or absent in MRS-PDFF. In RCT's, MRS-PDFF is currently used as an outcome measure to assess therapy response. Its successor is already being deployed: MRI-PDFF. This is a short whole-liver MRI scan, which takes approximately 18 seconds. The use of MRS- or MRI-PDFF has not boomed in the Netherlands. Reasons include unfamiliarity with the technique amongst both clinicians and radiologists, as well as increased reliance on ultrasound imaging with Fibroscan by hepatologists in particular. This latter method, however, is less accurate in classifying the various steatosis grades than MRS- and MRI-PDFF.


Assuntos
Fígado Gorduroso/diagnóstico por imagem , Fígado/diagnóstico por imagem , Espectroscopia de Ressonância Magnética/métodos , Biópsia , Fígado Gorduroso/patologia , Humanos , Países Baixos
18.
AJNR Am J Neuroradiol ; 37(10): 1824-1830, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27282862

RESUMO

BACKGROUND AND PURPOSE: White matter hyperintensities of presumed vascular origin in elderly patients with hypertension may be part of a general cerebral perfusion deficit, involving not only the white matter hyperintensities but also the surrounding normal-appearing white matter and gray matter. We aimed to study the relation between white matter hyperintensity volume and CBF and assess whether white matter hyperintensities are related to a general perfusion deficit. MATERIALS AND METHODS: In 185 participants of the Prevention of Dementia by Intensive Vascular Care trial between 72 and 80 years of age with systolic hypertension, white matter hyperintensity volume and CBF were derived from 3D FLAIR and arterial spin-labeling MR imaging, respectively. We compared white matter hyperintensity CBF, normal-appearing white matter CBF, and GM CBF across quartiles of white matter hyperintensity volume and assessed the continuous relation between these CBF estimates and white matter hyperintensity volume by using linear regression. RESULTS: Mean white matter hyperintensity CBF was markedly lower in higher quartiles of white matter hyperintensity volume, and white matter hyperintensity volume and white matter hyperintensity CBF were negatively related (standardized ß = -0.248, P = .001) in linear regression. We found no difference in normal-appearing white matter or GM CBF across quartiles of white matter hyperintensity volume or any relation between white matter hyperintensity volume and normal-appearing white matter CBF (standardized ß = -0.065, P = .643) or GM CBF (standardized ß = -0.035, P = .382) in linear regression. CONCLUSIONS: Higher white matter hyperintensity volume in elderly individuals with hypertension was associated with lower perfusion within white matter hyperintensities, but not with lower perfusion in the surrounding normal-appearing white matter or GM. These findings suggest that white matter hyperintensities in elderly individuals with hypertension relate to local microvascular alterations rather than a general cerebral perfusion deficit.

19.
AJNR Am J Neuroradiol ; 37(9): 1727-32, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27231223

RESUMO

BACKGROUND AND PURPOSE: Children with sickle cell disease have low hematocrit and elevated CBF, the latter of which can be assessed with arterial spin-labeling MR imaging. Quantitative CBF values are obtained by using an estimation of the longitudinal relaxation time of blood (T1blood). Because T1blood depends on hematocrit in healthy individuals, we investigated the importance of measuring T1blood in vivo with MR imaging versus calculating it from hematocrit or assuming an adult fixed value recommended by the literature, hypothesizing that measured T1blood would be the most suited for CBF quantification in children with sickle cell disease. MATERIALS AND METHODS: Four approaches for T1blood estimation were investigated in 39 patients with sickle cell disease and subsequently used in the CBF quantification from arterial spin-labeling MR imaging. First, we used 1650 ms as recommended by the literature (T1blood-fixed); second, T1blood calculated from hematocrit measured in patients (T1blood-hematocrit); third, T1blood measured in vivo with a Look-Locker MR imaging sequence (T1blood-measured); and finally, a mean value from T1blood measured in this study in children with sickle cell disease (T1blood-sickle cell disease). Quantitative flow measurements acquired with phase-contrast MR imaging served as reference values for CBF. RESULTS: T1blood-measured (1818 ± 107 ms) was higher than the literature recommended value of 1650 ms, was significantly lower than T1blood-hematocrit (2058 ± 123 ms, P < .001), and, most interesting, did not correlate with hematocrit measurements. Use of either T1blood-measured or T1blood-sickle cell disease provided the best agreement on CBF between arterial-spin labeling and phase-contrast MR imaging reference values. CONCLUSIONS: This work advocates the use of patient-specific measured T1blood or a standardized value (1818 ms) in the quantification of CBF from arterial spin-labeling in children with SCD.


Assuntos
Anemia Falciforme/sangue , Anemia Falciforme/diagnóstico por imagem , Circulação Cerebrovascular , Adolescente , Criança , Feminino , Hematócrito , Humanos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Masculino , Valores de Referência , Marcadores de Spin
20.
NMR Biomed ; 29(4): 519-26, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26876426

RESUMO

The purpose of this study was to assess whether there was an agreement between quantitative cerebral blood flow (CBF) and arterial cerebral blood volume (CBVA) measurements by [(15)O]H2O positron emission tomography (PET) and model-free QUASAR MRI. Twelve healthy subjects were scanned within a week in separate MRI and PET imaging sessions, after which quantitative and qualitative agreement between both modalities was assessed for gray matter, white matter and whole brain region of interests (ROI). The correlation between CBF measurements obtained with both modalities was moderate to high (r(2): 0.28-0.60, P < 0.05), although QUASAR significantly underestimated CBF by 30% (P < 0.001). CBVA was moderately correlated (r(2): 0.28-0.43, P < 0.05), with QUASAR yielding values that were only 27% of the [(15)O]H2O-derived values (P < 0.001). Group-wise voxel statistics identified minor areas with significant contrast differences between [(15)O]H2O PET and QUASAR MRI, indicating similar qualitative CBVA and CBF information by both modalities. In conclusion, the results of this study demonstrate that QUASAR MRI and [(15)O]H2O PET provide similar CBF and CBVA information, but with systematic quantitative discrepancies.


Assuntos
Artérias/fisiologia , Volume Sanguíneo/fisiologia , Circulação Cerebrovascular/fisiologia , Imageamento por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons/métodos , Água/metabolismo , Adulto , Feminino , Hemodinâmica , Humanos , Masculino , Isótopos de Oxigênio , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...