Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 110
Filtrar
1.
Sci Rep ; 12(1): 1910, 2022 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-35115579

RESUMO

Increasing the intensity to which high power laser pulses are focused has opened up new research possibilities, including promising new approaches to particle acceleration and phenomena such as high field quantum electrodynamics. Whilst the intensity achievable with a laser pulse of a given power can be increased via tighter focusing, the focal spot profile also plays an important role in the interaction physics. Here we show that the spatial-intensity distribution, and specifically the ratio of the intensity in the peak of the laser focal spot to the halo surrounding it, is important in the interaction of ultraintense laser pulses with solid targets. By comparing proton acceleration measurements from foil targets irradiated with by a near-diffraction-limited wavelength scale focal spot and larger F-number focusing, we find that this spatial-intensity contrast parameter strongly influences laser energy coupling to fast electrons. We find that for multi-petawatt pulses, spatial-intensity contrast is potentially as important as temporal-intensity contrast.

2.
Rev Sci Instrum ; 92(11): 113102, 2021 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-34852528

RESUMO

Accurate characterization of incident radiation is a fundamental challenge for diagnostic design. Herein, we present an efficient spectral analysis routine that is able to characterize multiple components within the spectral emission by analytically reducing the number of parameters. The technique is presented alongside the design of a hard x-ray linear absorption spectrometer using the example of multiple Boltzmann-like spectral distributions; however, it is generally applicable to all absorption based spectrometer designs and can be adapted to any incident spectral shape. This routine is demonstrated to be tolerable to experimental noise and suitable for real-time data processing at multi-Hz repetition rates.

3.
Phys Rev Lett ; 127(19): 194801, 2021 Nov 05.
Artigo em Inglês | MEDLINE | ID: mdl-34797126

RESUMO

We report on the selective acceleration of carbon ions during the interaction of ultrashort, circularly polarized and contrast-enhanced laser pulses, at a peak intensity of 5.5×10^{20} W/cm^{2}, with ultrathin carbon foils. Under optimized conditions, energies per nucleon of the bulk carbon ions reached significantly higher values than the energies of contaminant protons (33 MeV/nucleon vs 18 MeV), unlike what is typically observed in laser-foil acceleration experiments. Experimental data, and supporting simulations, emphasize different dominant acceleration mechanisms for the two ion species and highlight an (intensity dependent) optimum thickness for radiation pressure acceleration; it is suggested that the preceding laser energy reaching the target before the main pulse arrives plays a key role in a preferential acceleration of the heavier ion species.

5.
Philos Trans A Math Phys Eng Sci ; 379(2189): 20200022, 2021 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-33280560

RESUMO

When high-energy and high-power lasers interact with matter, a significant part of the incoming laser energy is transformed into transient electromagnetic pulses (EMPs) in the range of radiofrequencies and microwaves. These fields can reach high intensities and can potentially represent a significative danger for the electronic devices placed near the interaction point. Thus, the comprehension of the origin of these electromagnetic fields and of their distribution is of primary importance for the safe operation of high-power and high-energy laser facilities, but also for the possible use of these high fields in several promising applications. A recognized main source of EMPs is the target positive charging caused by the fast-electron emission due to laser-plasma interactions. The fast charging induces high neutralization currents from the conductive walls of the vacuum chamber through the target holder. However, other mechanisms related to the laser-target interaction are also capable of generating intense electromagnetic fields. Several possible sources of EMPs are discussed here and compared for high-energy and high-intensity laser-matter interactions, typical for inertial confinement fusion and laser-plasma acceleration. The possible effects on the electromagnetic field distribution within the experimental chamber, due to particle beams and plasma emitted from the target, are also described. This article is part of a discussion meeting issue 'Prospects for high gain inertial fusion energy (part 2)'.

6.
Sci Rep ; 10(1): 20157, 2020 Nov 19.
Artigo em Inglês | MEDLINE | ID: mdl-33214592

RESUMO

The scientific and technical advances continue to support novel discoveries by allowing scientists to acquire new insights into the structure and properties of matter using new tools and sources. Notably, neutrons are among the most valuable sources in providing such a capability. At the Institute of Laser Engineering, Osaka, the first steps are taken towards the development of a table-top laser-driven neutron source, capable of producing a wide range of energies with high brightness and temporal resolution. By employing a pure hydrogen moderator, maintained at cryogenic temperature, a cold neutron ([Formula: see text]) flux of [Formula: see text]/pulse was measured at the proximity of the moderator exit surface. The beam duration of hundreds of ns to tens of [Formula: see text] is evaluated for neutron energies ranging from 100s keV down to meV via Monte-Carlo techniques. Presently, with the upcoming J-EPoCH high repetition rate laser at Osaka University, a cold neutron flux in orders of [Formula: see text] is expected to be delivered at the moderator in a compact beamline.

7.
Rev Sci Instrum ; 91(10): 103301, 2020 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-33138566

RESUMO

A pixelated scintillator has been designed, fabricated, and tested using a laser-accelerated proton source for use in proton diagnostics at rep-rated laser facilities. The work presented here demonstrates the enhanced spatial resolution of thin, organic scintillators through a novel pixelation technique. Experimental measurements using laser-generated protons incident onto 130 µm-thick scintillators indicate a >20% reduction in the scintillator point spread function (PSF) for the detectors tested. The best performing pixelated detector reduced the ∼200 µm PSF of the stock material to ∼150 µm. The fabrication technique may be tailored to reduce the pixel size and achieve higher spatial resolutions.

8.
Sci Rep ; 10(1): 105, 2020 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-31919383

RESUMO

The spatio-temporal and polarisation properties of intense light is important in wide-ranging topics at the forefront of extreme light-matter interactions, including ultrafast laser-driven particle acceleration, attosecond pulse generation, plasma photonics, high-field physics and laboratory astrophysics. Here, we experimentally demonstrate modifications to the polarisation and temporal properties of intense light measured at the rear of an ultrathin target foil irradiated by a relativistically intense laser pulse. The changes are shown to result from a superposition of coherent radiation, generated by a directly accelerated bipolar electron distribution, and the light transmitted due to the onset of relativistic self-induced transparency. Simulations show that the generated light has a high-order transverse electromagnetic mode structure in both the first and second laser harmonics that can evolve on intra-pulse time-scales. The mode structure and polarisation state vary with the interaction parameters, opening up the possibility of developing this approach to achieve dynamic control of structured light fields at ultrahigh intensities.

9.
Opt Express ; 27(4): 4416-4423, 2019 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-30876060

RESUMO

We introduce a new approach to temporally resolve ultrafast micron-scale processes via the use of a multi-channel optical probe. We demonstrate that this technique enables highly precise time-resolved, two-dimensional spatial imaging of intense laser pulse propagation dynamics, plasma formation and laser beam filamentation within a single pulse over four distinct time frames. The design, development and optimization of the optical probe system is presented, as are representative experimental results from the first implementation of the multi-channel probe with a high-power laser pulse interaction with a helium gas jet target.

10.
Rev Sci Instrum ; 89(8): 083302, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30184626

RESUMO

Diagnosing fast electrons is important to understand the physics underpinning intense laser-produced plasmas. Here, we demonstrate experimentally that a Cherenkov radiation-based optical fibre can serve as a reliable diagnostic to characterize the fast electrons escaping from solid targets irradiated by ultra-intense laser pulses. Using optical fibre loops, the number and angular distributions of the escaping electrons are obtained. The data agree well with measurements made using image plate stacks. The optical fibre can be operated at high-repetition rates and is insensitive to x-rays and ion beams, which makes it advantageous over other routinely used fast electron diagnostics in some aspects.

11.
Rev Sci Instrum ; 89(7): 073502, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30068096

RESUMO

The characterisation of x-rays from laser-plasma interactions is of utmost importance as they can be useful for both monitoring electron dynamics and also applications in an industrial capacity. A novel versatile scintillator x-ray spectrometer diagnostic that is capable of single shot measurements of x-rays produced from laser-plasma interactions is presented here. Examples of the design and extraction of the temperature of the spectrum of x-rays produced in an intense laser-solid interaction (479 ± 39 keV) and the critical energy from a betatron source (30 ± 10 keV) are discussed. Finally, a simple optimisation process involving adjusting the scintillator thickness for a particular range of input spectra is demonstrated.

12.
Phys Rev Lett ; 120(20): 204801, 2018 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-29864368

RESUMO

A dual ion species plasma expansion scheme from a novel target structure is introduced, in which a nanometer-thick layer of pure deuterium exists as a buffer species at the target-vacuum interface of a hydrogen plasma. Modeling shows that by controlling the deuterium layer thickness, a composite H^{+}/D^{+} ion beam can be produced by target normal sheath acceleration (TNSA), with an adjustable ratio of ion densities, as high energy proton acceleration is suppressed by the acceleration of a spectrally peaked deuteron beam. Particle in cell modeling shows that a (4.3±0.7) MeV per nucleon deuteron beam is accelerated, in a directional cone of half angle 9°. Experimentally, this was investigated using state of the art cryogenic targetry and a spectrally peaked deuteron beam of (3.4±0.7) MeV per nucleon was measured in a cone of half angle 7°-9°, while maintaining a significant TNSA proton component.

13.
Nat Commun ; 9(1): 724, 2018 02 20.
Artigo em Inglês | MEDLINE | ID: mdl-29463872

RESUMO

The range of potential applications of compact laser-plasma ion sources motivates the development of new acceleration schemes to increase achievable ion energies and conversion efficiencies. Whilst the evolving nature of laser-plasma interactions can limit the effectiveness of individual acceleration mechanisms, it can also enable the development of hybrid schemes, allowing additional degrees of control on the properties of the resulting ion beam. Here we report on an experimental demonstration of efficient proton acceleration to energies exceeding 94 MeV via a hybrid scheme of radiation pressure-sheath acceleration in an ultrathin foil irradiated by a linearly polarised laser pulse. This occurs via a double-peaked electrostatic field structure, which, at an optimum foil thickness, is significantly enhanced by relativistic transparency and an associated jet of super-thermal electrons. The range of parameters over which this hybrid scenario occurs is discussed and implications for ion acceleration driven by next-generation, multi-petawatt laser facilities are explored.

14.
Sci Rep ; 7(1): 17968, 2017 12 21.
Artigo em Inglês | MEDLINE | ID: mdl-29269841

RESUMO

Burst Intensification by Singularity Emitting Radiation (BISER) is proposed. Singularities in multi-stream flows of emitting media cause constructive interference of emitted travelling waves, forming extremely localized sources of bright coherent emission. Here we for the first time demonstrate this extreme localization of BISER by direct observation of nano-scale coherent x-ray sources in a laser plasma. The energy emitted into the spectral range from 60 to 100 eV is up to ~100 nJ, corresponding to ~1010 photons. Simulations reveal that these sources emit trains of attosecond x-ray pulses. Our findings establish a new class of bright laboratory sources of electromagnetic radiation. Furthermore, being applicable to travelling waves of any nature (e.g. electromagnetic, gravitational or acoustic), BISER provides a novel framework for creating new emitters and for interpreting observations in many fields of science.

16.
Sci Rep ; 6: 32041, 2016 08 25.
Artigo em Inglês | MEDLINE | ID: mdl-27557592

RESUMO

We describe the first demonstration of plasma mirrors made using freely suspended, ultra-thin films formed dynamically and in-situ. We also present novel particle-in-cell simulations that for the first time incorporate multiphoton ionization and dielectric models that are necessary for describing plasma mirrors. Dielectric plasma mirrors are a crucial component for high intensity laser applications such as ion acceleration and solid target high harmonic generation because they greatly improve pulse contrast. We use the liquid crystal 8CB and introduce an innovative dynamic film formation device that can tune the film thickness so that it acts as its own antireflection coating. Films can be formed at a prolonged, high repetition rate without the need for subsequent realignment. High intensity reflectance above 75% and low-field reflectance below 0.2% are demonstrated, as well as initial ion acceleration experimental results that demonstrate increased ion energy and yield on shots cleaned with these plasma mirrors.

17.
Rev Sci Instrum ; 86(12): 123302, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26724017

RESUMO

The paper presents the calibration of Fuji BAS-TR image plate (IP) response to high energy carbon ions of different charge states by employing an intense laser-driven ion source, which allowed access to carbon energies up to 270 MeV. The calibration method consists of employing a Thomson parabola spectrometer to separate and spectrally resolve different ion species, and a slotted CR-39 solid state detector overlayed onto an image plate for an absolute calibration of the IP signal. An empirical response function was obtained which can be reasonably extrapolated to higher ion energies. The experimental data also show that the IP response is independent of ion charge states.

18.
J Xray Sci Technol ; 23(6): 791-7, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26756414

RESUMO

X-ray backscatter imaging can be used for a wide range of imaging applications, in particular for industrial inspection and portal security. Currently, the application of this imaging technique to the detection of landmines is limited due to the surrounding sand or soil strongly attenuating the 10s to 100s of keV X-rays required for backscatter imaging. Here, we introduce a new approach involving a 140 MeV short-pulse (< 100 fs) electron beam generated by laser wakefield acceleration to probe the sample, which produces Bremsstrahlung X-rays within the sample enabling greater depths to be imaged. A variety of detector and scintillator configurations are examined, with the best time response seen from an absorptive coated BaF2 scintillator with a bandpass filter to remove the slow scintillation emission components. An X-ray backscatter image of an array of different density and atomic number items is demonstrated. The use of a compact laser wakefield accelerator to generate the electron source, combined with the rapid development of more compact, efficient and higher repetition rate high power laser systems will make this system feasible for applications in the field. Content includes material subject to Dstl (c) Crown copyright (2014). Licensed under the terms of the Open Government Licence except where otherwise stated. To view this licence, visit http://www.nationalarchives.gov.uk/doc/open-government-licence/version/3 or write to the Information Policy Team, The National Archives, Kew, London TW9 4DU, or email: psi@ nationalarchives.gsi.gov.uk.


Assuntos
Bombas (Dispositivos Explosivos)/classificação , Lasers , Intensificação de Imagem Radiográfica/instrumentação , Espalhamento de Radiação , Tomografia Computadorizada por Raios X/instrumentação , Guerra , Desenho de Equipamento , Análise de Falha de Equipamento , Imagens de Fantasmas , Raios X
19.
Phys Rev Lett ; 113(18): 185001, 2014 Oct 31.
Artigo em Inglês | MEDLINE | ID: mdl-25396375

RESUMO

The influence of lattice-melt-induced resistivity gradients on the transport of mega-ampere currents of fast electrons in solids is investigated numerically and experimentally using laser-accelerated protons to induce isochoric heating. Tailoring the heating profile enables the resistive magnetic fields which strongly influence the current propagation to be manipulated. This tunable laser-driven process enables important fast electron beam properties, including the beam divergence, profile, and symmetry to be actively tailored, and without recourse to complex target manufacture.

20.
Clin Pharmacol Ther ; 96(4): 470-6, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24897241

RESUMO

Statins are widely used lipid-lowering drugs that are effective in reducing cardiovascular disease risk. Although they are generally well tolerated, they can cause muscle toxicity, which can lead to severe rhabdomyolysis. Research in this area has been hampered to some extent by the lack of standardized nomenclature and phenotypic definitions. We have used numerical and descriptive classifications and developed an algorithm to define statin-related myotoxicity phenotypes, including myalgia, myopathy, rhabdomyolysis, and necrotizing autoimmune myopathy.


Assuntos
Inibidores de Hidroximetilglutaril-CoA Redutases/efeitos adversos , Doenças Musculares/induzido quimicamente , Doenças Autoimunes/induzido quimicamente , Doenças Autoimunes/classificação , Humanos , Doenças Musculares/classificação , Mialgia/induzido quimicamente , Mialgia/classificação , Miosite/induzido quimicamente , Miosite/classificação , Fenótipo , Rabdomiólise/induzido quimicamente , Rabdomiólise/classificação , Fatores de Risco , Terminologia como Assunto , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...