Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ophthalmol Glaucoma ; 6(2): 215-223, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36096354

RESUMO

PURPOSE: To improve understanding of intraocular pressure (IOP) and its variance, this project identifies systemic and ocular characteristics of healthy eyes of adult volunteers including IOP variation, ocular biometrics, and aqueous humor dynamics (AHDs). These data serve as baseline controls for further studies from the Eye Dynamics and Engineering Network (EDEN) Consortium. DESIGN: Multicenter open-label clinical trial in healthy adults randomized to 1 week treatment with 2 approved glaucoma drugs in a crossover design. PARTICIPANTS: Among 135 healthy participants, 122 participants (aged 55.2 ± 8.8 years; 92 females, 30 males) completed the protocol. METHODS: Participants from the University of Michigan, Mayo Clinic, and University of Nebraska Medical Center underwent measurements of ocular biometrics, AHD, and IOP using 4 tonometers. Intraocular pressure data during 3 study visits without glaucoma medications were used in the analysis. The PhenX Toolkit survey acquired standardized data on medical history, surgical history, medications, smoking and alcohol exposures, and physical measures. MAIN OUTCOME MEASURES: The variability of IOP measurements within eyes was assessed as visit-to-visit IOP variation, within-visit IOP variation, and within-visit positional IOP variation. The concordance (or correlation) between eyes was also assessed. RESULTS: Average positional change of > 4.7 mmHg was detected with a range of 0.5-11.0 mmHg. Pearson correlation of IOP between eyes within a visit was 0.87 (95% confidence interval [CI], 0.82-0.91) for Goldmann applanation tonometry, 0.91 (95% CI, 0.88-0.94) for Icare rebound tonometry, and 0.91 (95% CI, 0.88-0.94) for pneumatonometry. There was a 4% to 12% asymmetric fluctuation of 3 mmHg or more between eyes between visits using rebound tonometry, 9% with Goldmann applanation tonometry, and 3% to 4% by pneumotonometry. The coefficient of variation between visits for the same eye ranged from 11.2% to 12.9% for pneumatonometry, from 13.6% to 17.4% for rebound tonometry, and 15.8% to 16.2% for Goldmann applanation tonometry. CONCLUSIONS: The current study from the EDEN Consortium describes measurement methods and data analyses with emphasis on IOP variability. Future papers will focus on changes in ocular biometrics and AHD with timolol or latanoprost treatment. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found after the references.


Assuntos
Glaucoma , Masculino , Feminino , Humanos , Adulto , Glaucoma/diagnóstico , Glaucoma/tratamento farmacológico , Pressão Intraocular , Tonometria Ocular
2.
J Ocul Pharmacol Ther ; 38(7): 489-495, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35856838

RESUMO

Purpose: To identify 24-h changes in ocular biometric parameters in subjects with ocular hypertension (OHT), and to determine if an intraocular pressure (IOP)-lowering drug alters these parameters. Methods: Thirty volunteers with OHT (58.6 ± 9.2 years of age) were enrolled in this randomized, double-masked, placebo-controlled, crossover study. Participants self-administered 0.2% brimonidine or placebo 3 times daily for 6 weeks. Measurements of seated and supine IOP, central cornea thickness (CCT), anterior chamber depth (ACD), axial length (AXL), and lens thickness were made at 8 am, 3 pm, 8 pm, and 3 am. Statistical tests were Student's 2-tailed paired t-tests or 2-way analysis of variance (ANOVA) followed by one-way ANOVA and post hoc testing. Results: Time of day had a significant effect on IOP, CCT, ACD, and AXL. In placebo-treated eyes, CCT was greater at 3 am than at any other time (P < 0.01), ACD and AXL were greater at 3 am and 8 pm than at 3 pm (P < 0.01). Daytime IOPs were higher than nighttime (seated, P = 0.007; supine, P = 0.018), and supine IOP at night was higher than seated IOP during the day (P < 0.001). Brimonidine did not lower IOP at night nor did it alter the 24-h patterns of CCT, ACD, and AXL. Conclusions: Ocular biometric parameters exhibit characteristic 24-h fluctuations in patients with OHT. At night compared with day, the supine IOP increases, the cornea thickens, the anterior chamber deepens, and the AXL increases. Brimonidine does not alter these parameters at times when it lowers IOP (day) nor when it does not (night). Clinical Trial Registration number: NCT0132419.


Assuntos
Hipertensão Ocular , Tonometria Ocular , Biometria , Tartarato de Brimonidina/farmacologia , Tartarato de Brimonidina/uso terapêutico , Estudos Cross-Over , Humanos , Pressão Intraocular , Hipertensão Ocular/tratamento farmacológico
3.
Invest Ophthalmol Vis Sci ; 58(3): 1462-1468, 2017 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-28264102

RESUMO

Purpose: This study was designed to evaluate the changes in aqueous humor dynamics (AHD) produced by selective laser trabeculoplasty (SLT) and to explore if baseline AHD parameters are predictive of IOP response to SLT. Methods: Thirty-one consecutive subjects diagnosed with ocular hypertension or primary open-angle glaucoma scheduled to undergo SLT as their primary IOP-lowering therapy were enrolled in this prospective observational study. Subjects underwent baseline assessment of AHD in both eyes. Variables assessed were IOPs at 9 AM and noon, aqueous humor flow rate (fluorophotometry), episcleral venous pressure (EVP, venomanometry), outflow facility (pneumatonography and fluorophotometry) and uveoscleral outflow (calculated using modified Goldmann equation). All subjects underwent 360 degrees SLT and AHD measurements were repeated 3 months later. Results: Compared with baseline, IOPs after SLT were significantly lower at 9 AM (22.9 ± 5.1 vs. 19.7 ± 3.0 mm Hg; P = 0.001) and noon (23.4 ± 4.6 vs. 20.0 ± 3.5 mm Hg; P < 0.001). Outflow facility by fluorophotometry was significantly increased from 0.17 ± 0.11 µL/min/mm Hg at baseline to 0.24 ± 0.14 µL/min/mm Hg at 3 months (P = 0.008). Outflow facility by tonography (baseline: 0.16 ± 0.07 µL/min/mm Hg vs. 3 months: 0.22 ± 0.16 µL/min/mm Hg; P = 0.046) was similarly increased. No change in aqueous flow or EVP was observed. There were no changes in IOP or AHD in the contralateral untreated eye. Using multiple linear regression models, higher baseline aqueous flow, lower baseline outflow facility, and possibly lower uvescleral outflow were associated with more IOP lowering with SLT. Conclusions: The IOP-lowering effect of SLT is mediated through an increase in outflow facility. There is no contralateral effect. Higher aqueous flow and lower outflow facility may be predictive of better response to SLT.


Assuntos
Glaucoma de Ângulo Aberto/cirurgia , Pressão Intraocular/fisiologia , Terapia a Laser/métodos , Hipertensão Ocular/cirurgia , Trabeculectomia/métodos , Idoso , Humor Aquoso/metabolismo , Feminino , Fluorofotometria , Glaucoma de Ângulo Aberto/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Hipertensão Ocular/fisiopatologia , Estudos Prospectivos , Resultado do Tratamento
4.
J Glaucoma ; 23(5): 276-81, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24886701

RESUMO

PURPOSE: The effects of brimonidine on daytime and nighttime intraocular pressure (IOP) and aqueous humor dynamics were evaluated in volunteers with ocular hypertension (OHT). PATIENTS AND METHODS: Thirty participants with OHT (58.6±1.7 years old, mean±SEM) were enrolled into this randomized, double-masked, cross-over study. For 6 weeks, participants self-administered 0.2% brimonidine or placebo 3 times daily. During daytime and nighttime visits, measurements included aqueous flow (Fa) by fluorophotometry, outflow facility (C) by tonography, episcleral venous pressure (Pev) by venomanometry, and seated and supine IOP by pneumatonometry. Uveoscleral outflow (U) was calculated mathematically. RESULTS: When treated with placebo, nighttime supine Pev (11.2±0.25 mm Hg) was higher (P<0.05) compared with daytime seated Pev (10.2±0.25 mm Hg), and Fa and U were significantly reduced at night. Brimonidine significantly lowered seated IOP at 9:00 AM and 11:00 AM, 9:00 PM and 11:00 PM and supine IOP at 9:00 AM and 11:00 AM. Brimonidine increased U at 9 AM and 11 AM (P<0.01) and had no effect on daytime and nighttime Fa, C, or Pev. CONCLUSIONS: In subjects with OHT, brimonidine treatment for 6 weeks significantly reduces seated IOP during the day by increasing uveoscleral outflow. The lack of IOP effect at night can be explained by failure to overcome a normal nighttime reduction of uveoscleral outflow.


Assuntos
Agonistas de Receptores Adrenérgicos alfa 2/uso terapêutico , Humor Aquoso/fisiologia , Ritmo Circadiano/efeitos dos fármacos , Pressão Intraocular/efeitos dos fármacos , Hipertensão Ocular/tratamento farmacológico , Quinoxalinas/uso terapêutico , Tartarato de Brimonidina , Paquimetria Corneana , Estudos Cross-Over , Método Duplo-Cego , Feminino , Fluorofotometria , Humanos , Masculino , Pessoa de Meia-Idade , Soluções Oftálmicas , Estudos Prospectivos , Decúbito Dorsal/fisiologia , Tonometria Ocular , Pressão Venosa/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...