Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
1.
Int J Radiat Oncol Biol Phys ; 113(5): 967-973, 2022 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-35483539

RESUMO

PURPOSE: The high potential of microbeam radiation therapy (MRT) in improving tumor control while reducing side effects has been shown by numerous preclinical studies. MRT offers a widened therapeutic window by using the periodical spatial fractionation of synchrotron generated x-rays into an array of intense parallel microbeams. MRT now enters a clinical transfer phase. As proof of principle and cornerstone for the safe clinical transfer of MRT, we conducted a "first in dog" trial under clinical conditions. In this report, we evaluated whether a 3-dimensional conformal MRT can be safely delivered as exclusive radiosurgical treatment in animal patients METHODS AND MATERIALS: We irradiated a 17.5-kg French bulldog for a spontaneous brain tumor (glioma suspected on magnetic resonance imaging) with conformal high-dose-rate microbeam arrays (50-µm-wide microbeams, replicated with a pitch of 400 µm) of synchrotron-generated x-rays. The dose prescription adjusted a minimal cumulated valley dose of 2.8 Gy to the plnning target volume (PTV) (cinical target volume (CTV)+ 1 mm). Thus, each beam delivered 20 to 25 Gy to the target as peak doses, and ∼1 Gy as valley doses RESULTS: The treatment was successfully delivered. Clinical follow-up over 3 months showed a significant improvement of the dog's quality of life: the symptoms disappeared. Magnetic resonance imaging, performed 3 months after irradiation, revealed reduction in tumor size (-87.4%) and mass effect with normalization of the left lateral ventricle. CONCLUSIONS: To our knowledge, this neuro-oncologic veterinary trial is the first 3-dimensional conformal synchrotron x-ray MRT treatment of a spontaneous intracranial tumor in a large animal. It is an essential last step toward the clinical transfer of MRT in the near future to demonstrate the feasibility and safety of treating deep-seated tumors using synchrotron-generated microbeams.


Assuntos
Neoplasias Encefálicas , Glioma , Radiocirurgia , Animais , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/veterinária , Cães , Glioma/diagnóstico por imagem , Glioma/patologia , Glioma/radioterapia , Qualidade de Vida , Radiocirurgia/métodos , Síncrotrons
2.
Brain ; 145(6): 1978-1991, 2022 06 30.
Artigo em Inglês | MEDLINE | ID: mdl-35141747

RESUMO

Absence epilepsy belongs to genetic epilepsies and is characterized by recurrent generalized seizures that are concomitant with alterations of consciousness and associated with cognitive comorbidities. Little is known about the mechanisms leading to occurrence of epileptic seizures (i.e. epileptogenesis) and, in particular, it remains an open question as to whether neuronal hypersynchronization, a key feature in seizure initiation, could result from aberrant structural connectivity within neuronal networks endowing them with epileptic properties. In the present study, we addressed this question using a genetic model of absence epilepsy in the rat where seizures initiate in the whisker primary somatosensory cortex (wS1). We hypothesized that alterations in structural connectivity of neuronal networks within wS1 contribute to pathological neuronal synchronization responsible for seizures. First, we used rabies virus-mediated retrograde synaptic tracing and showed that cortical neurons located in both upper- and deep-layers of wS1 displayed aberrant and significantly increased connectivity in the genetic model of absence epilepsy, as highlighted by a higher number of presynaptic partners. Next, we showed at the functional level that disrupting these aberrant wS1 neuronal networks with synchrotron X-ray-mediated cortical microtransections drastically decreased both the synchronization and seizure power of wS1 neurons, as revealed by in vivo local field potential recordings with multichannel probes. Taken together, our data provide for the first time strong evidence that increased structural connectivity patterns of cortical neurons represent critical pathological substrates for increased neuronal synchronization and generation of absence seizures.


Assuntos
Epilepsia Tipo Ausência , Animais , Eletroencefalografia , Epilepsia Tipo Ausência/genética , Neurônios/fisiologia , Ratos , Convulsões , Vibrissas
3.
Sci Rep ; 9(1): 17082, 2019 11 19.
Artigo em Inglês | MEDLINE | ID: mdl-31745153

RESUMO

The functional roles of the Caudate nucleus (Cd) are well known. Selective Cd lesions can be found in neurological disorders. However, little is known about the dynamics of the behavioral changes during progressive Cd ablation. Current stereotactic radiosurgery technologies allow the progressive ablation of a brain region with limited adverse effects in surrounding normal tissues. This could be of high interest for the study of the modified behavioral functions in relation with the degree of impairment of the brain structures. Using hypofractionated stereotactic radiotherapy combined with synchrotron microbeam radiation, we investigated, during one year after irradiation, the effects of unilateral radio-ablation of the right Cd on the behavior of Yucatan minipigs. The right Cd was irradiated to a minimal dose of 35.5 Gy delivered in three fractions. MRI-based morphological brain integrity and behavioral functions, i.e. locomotion, motivation/hedonism were assessed. We detected a progressive radio-necrosis leading to a quasi-total ablation one year after irradiation, with an additional alteration of surrounding areas. Transitory changes in the motivation/hedonism were firstly detected, then on locomotion, suggesting the influence of different compensatory mechanisms depending on the functions related to Cd and possibly some surrounding areas. We concluded that early behavioral changes related to eating functions are relevant markers for the early detection of ongoing lesions occurring in Cd-related neurological disorders.


Assuntos
Comportamento Animal/efeitos da radiação , Encéfalo/patologia , Núcleo Caudado/patologia , Irradiação Craniana/efeitos adversos , Comportamento Alimentar/efeitos da radiação , Locomoção/efeitos da radiação , Lesões por Radiação/patologia , Animais , Encéfalo/efeitos da radiação , Núcleo Caudado/efeitos da radiação , Masculino , Lesões por Radiação/etiologia , Suínos , Porco Miniatura , Síncrotrons
4.
Phys Med ; 65: 227-237, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31574356

RESUMO

Microbeam radiation therapy (MRT) uses synchrotron arrays of X-ray microbeams to take advantage of the spatial fractionation effect for normal tissue sparing. In this study, radiochromic film dosimetry was performed for a treatment where MRT is introduced as a dose boost in a hypofractionated stereotactic radiotherapy (SRT) scheme. The isocenter dose was measured using an ionization chamber and two dimensional dose distributions were determined using radiochromic films. To compare the measured dose distribution to the MRT treatment plan, peak and valley were displayed in separate dosemaps. The measured and computed isocenter doses were compared and a two-dimensional 2%/2 mm normalized γ-index analysis with a 90% passing rate criterion was computed. For SRT, a difference of 2.6% was observed in the dose at the isocenter from the treatment plan and film measurement, with a passing rate of 96% for the γ-index analysis. For MRT, peak and valley doses differences of 25.6% and 8.2% were observed, respectively but passing rates of 96% and 90% respectively were obtained from the normalized γ-index maps. The differences in isocenter doses measured in MRT should be further investigated. We present the methodology of patient specific quality assurance (QA) for studying MRT dose distributions and discuss ideas to improve absolute dosimetry. This patient specific QA will be used for large animal trials quality assurance where MRT will be administered as a dose boost in conventional SRT. The observed remaining discrepancies should be studied against approximations in the TPS phantom materials, beams characteristics or film read-out procedures.


Assuntos
Dosimetria Fotográfica/métodos , Radioterapia/métodos , Neoplasias Encefálicas/radioterapia , Fracionamento da Dose de Radiação , Humanos , Imagens de Fantasmas , Radiometria/métodos , Dosagem Radioterapêutica , Síncrotrons , Raios X
5.
Radiother Oncol ; 139: 56-61, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31307824

RESUMO

This paper reviews the current state of the art of an emerging form of radiosurgery dedicated to brain tumour treatment and which operates at very high dose rate (kGy·s-1). Microbeam Radiation Therapy uses synchrotron-generated X-rays which triggered normal tissue sparing partially mediated by FLASH effect.


Assuntos
Neoplasias Encefálicas/radioterapia , Radiocirurgia/métodos , Síncrotrons , Animais , Neoplasias Encefálicas/irrigação sanguínea , Protocolos Clínicos , Modelos Animais de Doenças , Humanos , Raios X
6.
J Synchrotron Radiat ; 23(Pt 5): 1180-90, 2016 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-27577773

RESUMO

Microbeam radiation therapy (MRT) is a novel irradiation technique for brain tumours treatment currently under development at the European Synchrotron Radiation Facility in Grenoble, France. The technique is based on the spatial fractionation of a highly brilliant synchrotron X-ray beam into an array of microbeams using a multi-slit collimator (MSC). After promising pre-clinical results, veterinary trials have recently commenced requiring the need for dedicated quality assurance (QA) procedures. The quality of MRT treatment demands reproducible and precise spatial fractionation of the incoming synchrotron beam. The intensity profile of the microbeams must also be quickly and quantitatively characterized prior to each treatment for comparison with that used for input to the dose-planning calculations. The Centre for Medical Radiation Physics (University of Wollongong, Australia) has developed an X-ray treatment monitoring system (X-Tream) which incorporates a high-spatial-resolution silicon strip detector (SSD) specifically designed for MRT. In-air measurements of the horizontal profile of the intrinsic microbeam X-ray field in order to determine the relative intensity of each microbeam are presented, and the alignment of the MSC is also assessed. The results show that the SSD is able to resolve individual microbeams which therefore provides invaluable QA of the horizontal field size and microbeam number and shape. They also demonstrate that the SSD used in the X-Tream system is very sensitive to any small misalignment of the MSC. In order to allow as rapid QA as possible, a fast alignment procedure of the SSD based on X-ray imaging with a low-intensity low-energy beam has been developed and is presented in this publication.

7.
Med Phys ; 43(6): 3157-3167, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27277061

RESUMO

PURPOSE: Upcoming veterinary trials in microbeam radiation therapy (MRT) demand for more advanced irradiation techniques than in preclinical research with small animals. The treatment of deep-seated tumors in cats and dogs with MRT requires sophisticated irradiation geometries from multiple ports, which impose further efforts to spare the normal tissue surrounding the target. METHODS: This work presents the development and benchmarking of a precise patient alignment protocol for MRT at the biomedical beamline ID17 of the European Synchrotron Radiation Facility (ESRF). The positioning of the patient prior to irradiation is verified by taking x-ray projection images from different angles. RESULTS: Using four external fiducial markers of 1.7 mm diameter and computed tomography-based treatment planning, a target alignment error of less than 2 mm can be achieved with an angular deviation of less than 2(∘). Minor improvements on the protocol and the use of smaller markers indicate that even a precision better than 1 mm is technically feasible. Detailed investigations concerning the imaging dose lead to the conclusion that doses for skull radiographs lie in the same range as dose reference levels for human head radiographs. A currently used online dose monitor for MRT has been proven to give reliable results for the imaging beam. CONCLUSIONS: The ESRF biomedical beamline ID17 is technically ready to apply conformal image-guided MRT from multiple ports to large animals during future veterinary trials.

8.
J Synchrotron Radiat ; 23(1): 339-43, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26698083

RESUMO

A fast positioning method for brain tumor microbeam irradiations for preclinical studies at third-generation X-ray sources is described. The three-dimensional alignment of the animals relative to the X-ray beam was based on the X-ray tomography multi-slices after iodine infusion. This method used pink-beam imaging produced by the ID17 wiggler. A graphical user interface has been developed in order to define the irradiation parameters: field width, height, number of angles and X-ray dose. This study is the first reporting an image guided method for soft tissue synchrotron radiotherapy. It allowed microbeam radiation therapy irradiation fields to be reduced by a factor of ∼20 compared with previous studies. It permitted more targeted, more efficient brain tumor microbeam treatments and reduces normal brain toxicity of the radiation treatment.


Assuntos
Neoplasias Encefálicas/radioterapia , Animais , Neoplasias Encefálicas/patologia , Imageamento por Ressonância Magnética , Ratos , Ratos Endogâmicos F344
9.
PLoS One ; 8(1): e53549, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23341950

RESUMO

Synchrotron-generated X-ray microplanar beams (microbeams) are characterized by the ability to deliver extremely high doses of radiation to spatially restricted volumes of tissue. Minimal dose spreading outside the beam path provides an exceptional degree of protection from radio-induced damage to the neurons and glia adjacent to the microscopic slices of tissue irradiated. The preservation of cortical architecture following high-dose microbeam irradiation and the ability to induce non-invasively the equivalent of a surgical cut over the cortex is of great interest for the development of novel experimental models in neurobiology and new treatment avenues for a variety of brain disorders. Microbeams (size 100 µm/600 µm, center-to-center distance of 400 µm/1200 µm, peak entrance doses of 360-240 Gy/150-100 Gy) delivered to the sensorimotor cortex of six 2-month-old naïve rats generated histologically evident cortical transections, without modifying motor behavior and weight gain up to 7 months. Microbeam transections of the sensorimotor cortex dramatically reduced convulsive seizure duration in a further group of 12 rats receiving local infusion of kainic acid. No subsequent neurological deficit was associated with the treatment. These data provide a novel tool to study the functions of the cortex and pave the way for the development of new therapeutic strategies for epilepsy and other neurological diseases.


Assuntos
Convulsões/prevenção & controle , Convulsões/fisiopatologia , Córtex Somatossensorial/patologia , Córtex Somatossensorial/fisiopatologia , Síncrotrons , Animais , Histonas/metabolismo , Imuno-Histoquímica , Masculino , Fosfoproteínas/metabolismo , Ratos , Ratos Wistar , Teste de Desempenho do Rota-Rod , Convulsões/patologia , Coloração e Rotulagem , Raios X
10.
Neurobiol Dis ; 51: 152-60, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23159741

RESUMO

Radiotherapy has shown some efficacy for epilepsies but the insufficient confinement of the radiation dose to the pathological target reduces its indications. Synchrotron-generated X-rays overcome this limitation and allow the delivery of focalized radiation doses to discrete brain volumes via interlaced arrays of microbeams (IntMRT). Here, we used IntMRT to target brain structures involved in seizure generation in a rat model of absence epilepsy (GAERS). We addressed the issue of whether and how synchrotron radiotherapeutic treatment suppresses epileptic activities in neuronal networks. IntMRT was used to target the somatosensory cortex (S1Cx), a region involved in seizure generation in the GAERS. The antiepileptic mechanisms were investigated by recording multisite local-field potentials and the intracellular activity of irradiated S1Cx pyramidal neurons in vivo. MRI and histopathological images displayed precise and sharp dose deposition and revealed no impairment of surrounding tissues. Local-field potentials from behaving animals demonstrated a quasi-total abolition of epileptiform activities within the target. The irradiated S1Cx was unable to initiate seizures, whereas neighboring non-irradiated cortical and thalamic regions could still produce pathological oscillations. In vivo intracellular recordings showed that irradiated pyramidal neurons were strongly hyperpolarized and displayed a decreased excitability and a reduction of spontaneous synaptic activities. These functional alterations explain the suppression of large-scale synchronization within irradiated cortical networks. Our work provides the first post-irradiation electrophysiological recordings of individual neurons. Altogether, our data are a critical step towards understanding how X-ray radiation impacts neuronal physiology and epileptogenic processes.


Assuntos
Epilepsia Tipo Ausência/radioterapia , Rede Nervosa/efeitos da radiação , Córtex Somatossensorial/efeitos da radiação , Animais , Modelos Animais de Doenças , Eletroencefalografia , Epilepsia Tipo Ausência/fisiopatologia , Feminino , Rede Nervosa/fisiopatologia , Ratos , Córtex Somatossensorial/fisiopatologia , Terapia por Raios X/métodos
11.
J Synchrotron Radiat ; 18(Pt 5): 689-96, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21862846

RESUMO

High-resolution analyser-based X-ray imaging computed tomography (HR ABI-CT) findings on in vitro human breast cancer are compared with histopathology, mammography, computed tomography (CT) and magnetic resonance imaging. The HR ABI-CT images provided significantly better low-contrast visibility compared with the standard radiological images. Fine cancer structures indistinguishable and superimposed in mammograms were seen, and could be matched with the histopathological results. The mean glandular dose was less than 1 mGy in mammography and 12-13 mGy in CT and ABI-CT. The excellent visibility of in vitro breast cancer suggests that HR ABI-CT may have a valuable role in the future as an adjunct or even alternative to current breast diagnostics, when radiation dose is further decreased, and compact synchrotron radiation sources become available.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mamografia/métodos , Tomografia Computadorizada por Raios X/métodos , Mama/patologia , Neoplasias da Mama/patologia , Carcinoma Ductal de Mama/diagnóstico por imagem , Carcinoma Ductal de Mama/patologia , Carcinoma Lobular/diagnóstico por imagem , Carcinoma Lobular/patologia , Feminino , Humanos , Imageamento por Ressonância Magnética , Doses de Radiação , Síncrotrons
12.
Eur J Radiol ; 79(2): 323-7, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20732772

RESUMO

BACKGROUND: Although the quality of imaging techniques available for neurovascular angiography in the hospital environment has significantly improved over the last decades, the equipment used for clinical work is not always suited for neurovascular research in animal models. We have previously investigated the suitability of synchrotron-based K-edge digital subtraction angiography (KEDSA) after intravenous injection of iodinated contrast agent for neurovascular angiography in radiography mode in both rabbit and pig models. We now have used the KEDSA technique for the acquisition of three-dimensional images and dual energy CT. MATERIALS AND METHODS: All experiments were conducted at the biomedical beamline ID 17 of the European Synchrotron Radiation Facility (ESRF). A solid state germanium (Ge) detector was used for the acquisition of image pairs at 33.0 and 33.3 keV. Three-dimensional images were reconstructed from an image series containing 60 single images taken throughout a full rotation of 360°. CT images were reconstructed from two half-acquisitions with 720 projections each. RESULTS: The small detector field of view was a limiting factor in our experiments. Nevertheless, we were able to show that dual energy CT using the KEDSA technique available at ID 17 is suitable for neurovascular research in animal models.


Assuntos
Angiografia Digital/métodos , Angiografia Cerebral/métodos , Tomografia Computadorizada por Raios X/métodos , Animais , Meios de Contraste/administração & dosagem , Germânio , Imageamento Tridimensional , Iohexol/administração & dosagem , Iohexol/análogos & derivados , Modelos Animais , Coelhos , Suínos
13.
J Synchrotron Radiat ; 17(3): 325-31, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20400830

RESUMO

A fast 50 microm-accuracy alignment procedure has been developed for the radiosurgery of brain lesions in rats, using microbeam radiation therapy. In vivo imaging was performed using the pink beam (35-60 keV) produced by the ID17 wiggler at the ESRF opened at 120 mm and filtered. A graphical user interface has been developed in order to define the irradiation field size and to position the target with respect to the skull structures observed in X-ray images. The method proposed here allows tremendous time saving by skipping the swap from white beam to monochromatic beam and vice versa. To validate the concept, the somatosensory cortex or thalamus of GAERS rats were irradiated under several ports using this alignment procedure. The magnetic resonance images acquired after contrast agent injection showed that the irradiations were selectively performed in these two expected brain regions. Image-guided microbeam irradiations have therefore been realised for the first time ever, and, thanks to this new development, the ID17 biomedical beamline provides a major tool allowing brain radiosurgery trials on animal patients.


Assuntos
Encéfalo/efeitos da radiação , Animais , Encéfalo/anatomia & histologia , Calibragem , Imageamento por Ressonância Magnética , Radiocirurgia , Ratos , Interface Usuário-Computador
14.
PLoS One ; 5(2): e9028, 2010 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-20140254

RESUMO

Microbeam Radiation Therapy (MRT) is a preclinical form of radiosurgery dedicated to brain tumor treatment. It uses micrometer-wide synchrotron-generated X-ray beams on the basis of spatial beam fractionation. Due to the radioresistance of normal brain vasculature to MRT, a continuous blood supply can be maintained which would in part explain the surprising tolerance of normal tissues to very high radiation doses (hundreds of Gy). Based on this well described normal tissue sparing effect of microplanar beams, we developed a new irradiation geometry which allows the delivery of a high uniform dose deposition at a given brain target whereas surrounding normal tissues are irradiated by well tolerated parallel microbeams only. Normal rat brains were exposed to 4 focally interlaced arrays of 10 microplanar beams (52 microm wide, spaced 200 microm on-center, 50 to 350 keV in energy range), targeted from 4 different ports, with a peak entrance dose of 200Gy each, to deliver an homogenous dose to a target volume of 7 mm(3) in the caudate nucleus. Magnetic resonance imaging follow-up of rats showed a highly localized increase in blood vessel permeability, starting 1 week after irradiation. Contrast agent diffusion was confined to the target volume and was still observed 1 month after irradiation, along with histopathological changes, including damaged blood vessels. No changes in vessel permeability were detected in the normal brain tissue surrounding the target. The interlacing radiation-induced reduction of spontaneous seizures of epileptic rats illustrated the potential pre-clinical applications of this new irradiation geometry. Finally, Monte Carlo simulations performed on a human-sized head phantom suggested that synchrotron photons can be used for human radiosurgical applications. Our data show that interlaced microbeam irradiation allows a high homogeneous dose deposition in a brain target and leads to a confined tissue necrosis while sparing surrounding tissues. The use of synchrotron-generated X-rays enables delivery of high doses for destruction of small focal regions in human brains, with sharper dose fall-offs than those described in any other conventional radiation therapy.


Assuntos
Doses de Radiação , Radiocirurgia/métodos , Síncrotrons , Animais , Comportamento Animal/efeitos da radiação , Encéfalo/metabolismo , Encéfalo/patologia , Encéfalo/efeitos da radiação , Proteína Glial Fibrilar Ácida/metabolismo , Humanos , Imuno-Histoquímica , Imageamento por Ressonância Magnética , Método de Monte Carlo , Ratos , Fatores de Tempo , Raios X
15.
Eur J Radiol ; 73(3): 677-81, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19233584

RESUMO

BACKGROUND: K-edge digital subtraction angiography (KEDSA) combined with the tunability of synchrotron beam yields an imaging technique that is highly sensitive to low concentrations of contrast agents. Thus, contrast agent can be administered intravenously, obviating the need for insertion of a guided catheter to deliver a bolus of contrast agent close to the target tissue. With the high-resolution detectors used at synchrotron facilities, images can be acquired at high spatial resolution. Thus, the KEDSA appears particularly suited for studies of neurovascular pathology in animal models, where the vascular diameters are significantly smaller than in human patients. MATERIALS AND METHODS: This feasibility study was designed to test the suitability of KEDSA after intravenous injection of iodine-based contrast agent for use in a pig model. Four adult male pigs were used for our experiments. Neurovascular angiographic images were acquired using KEDSA with a solid state Germanium (Ge) detector at the European Synchrotron Radiation Facility (ESRF) in Grenoble, France. RESULTS: After intravenous injection of 0.9 ml/kg iodinated contrast agent (Xenetix), the peak iodine concentrations in the internal carotid and middle cerebral arteries reached 35 mg/ml. KEDSA images in radiography mode allowed the visualization of intracranial arteries of less than 1.5mm diameter.


Assuntos
Angiografia Digital/métodos , Angiografia Cerebral/métodos , Meios de Contraste/administração & dosagem , Iohexol/análogos & derivados , Síncrotrons , Animais , Meios de Contraste/farmacocinética , Estudos de Viabilidade , Germânio , Iohexol/administração & dosagem , Iohexol/farmacocinética , Masculino , Modelos Animais , Suínos
16.
J Synchrotron Radiat ; 16(Pt 2): 310-3, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19240345

RESUMO

One of the most fascinating objects in the Rijksmuseum (Amsterdam, The Netherlands) is an early 16th century prayer nut. This spherical wooden object measures 4 cm in diameter and consists of two hemispheres connected with a small hinge so that it can be opened. The interior of the nut holds wood carvings with scenes from the life of Christ. These miniature reliefs show an incredible degree of finish with carving details well beyond the millimetre scale. In the present paper it is shown how synchrotron-based computer X-ray tomography revealed the structure and fabrication method of the bead. The central part of the relief was cut from a single piece of wood, rather than assembled from multiple components, underlining the extraordinary manual dexterity of its maker. In addition, a piece of fibrous material contained in the inner structure of the bead is revealed. This may have served as a carrier for an odorous compound, which would be in line with the religious function of the prayer nut.


Assuntos
Teste de Materiais/métodos , Nozes/ultraestrutura , Religião , Escultura , Síncrotrons , Tomografia Computadorizada por Raios X/métodos , Países Baixos
17.
Phys Med Biol ; 52(8): 2197-211, 2007 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-17404464

RESUMO

The aim of this study was to introduce high-resolution computed tomography (CT) of breast tumours using the diffraction-enhanced x-ray imaging (DEI) technique and to compare results with radiological and histo-pathological examinations. X-ray CT images of tumour-bearing breast tissue samples were acquired by monochromatic synchrotron radiation (SR). Due to the narrow beam and a large sample-to-detector distance scattering is rejected in the absorption contrast images (SR-CT). Large contrast enhancement is achieved by the use of the DEI-CT method, where the effects of refraction and scatter rejection are analysed by crystal optics. Clinical mammograms and CT images were recorded as reference material for a radiological examination. Three malignant and benign samples were studied in detail. Their radiographs were compared with optical images of stained histological sections. The DEI-CT images map accurately the morphology of the samples, including collagen strands and micro-calcifications of dimensions less than 0.1 mm. Histo-pathological examination and reading of the radiographs were done independently, and the conclusions were in general agreement. High-resolution DEI-CT images show strong contrast and permit visualization of details invisible in clinical radiographs. The radiation dose may be reduced by an order of magnitude without compromising image quality, which would make possible clinical in vivo DEI-CT with future compact SR sources.


Assuntos
Algoritmos , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Mamografia/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Difração de Raios X/métodos , Feminino , Humanos , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
18.
Phys Med Biol ; 52(4): 1001-12, 2007 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-17264366

RESUMO

K-edge digital subtraction angiography (KEDSA), a recently developed synchrotron-based technique, utilizes monochromatic radiation and allows acquisition of high-quality angiography images after intravenous administration of contrast agent. We tested KEDSA for its suitability for intravenous cerebral angiography in an animal model. Adult male New Zealand rabbits were subjected to either angiography with conventional x-ray equipment or synchrotron-based intravenous KEDSA, using an iodine-based contrast agent. Angiography with conventional x-ray equipment after intra-arterial administration of contrast agent demonstrated the major intracranial vessels but no smaller branches. KEDSA was able to visualize the major intracranial vessels as well as smaller branches in both radiography mode (planar images) and tomography mode. Visualization was achieved with as little as 0.5 ml kg-1 of iodinated contrast material. We were able to obtain excellent visualization of the cerebral vasculature in an animal model using intravenous injection of contrast material, using synchrotron-based KEDSA.


Assuntos
Angiografia Digital/métodos , Angiografia Cerebral/métodos , Artérias Cerebrais , Síncrotrons , Angiografia Digital/instrumentação , Animais , Angiografia Cerebral/instrumentação , Artérias Cerebrais/diagnóstico por imagem , Artérias Cerebrais/patologia , Meios de Contraste/administração & dosagem , Meios de Contraste/farmacologia , Bombas de Infusão , Masculino , Modelos Animais , Coelhos , Cintilografia
19.
Am J Phys Anthropol ; 131(3): 311-23, 2006 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-16617433

RESUMO

A Khoratpithecus piriyai lower jaw corresponds to a well-preserved Late Miocene hominoid fossil from northeastern Thailand. Its morphology and internal structure, using a microcomputed tomography scan, are described and compared to those of other known Miocene hominoids. It originated from fluviatile sand and gravel deposits of a large river, and was associated with many fossil tree trunks, wood fragments, and large vertebrate remains. A biochronological analysis by using associated mammal fauna gives an estimated geological age between 9-6 Ma. The flora indicates the occurrence of a riverine tropical forest and wide areas of grassland. K. piriyai displays many original characters, such as the great breadth of its anterior dentition, suggesting large incisors, large lower M3, a canine with a flat lingual wall, and symphysis structure. Several of its morphological derived characters are shared with the orangutan, indicating sister-group relationship with that extant ape. This relationship is additionally strongly supported by the absence of anterior digastric muscle scars. These shared derived characters are not present in Sivapithecus, Ankarapithecus, and Lufengpithecus, which are therefore considered more distant relatives to the orangutan than Khoratpithecus. The Middle Miocene K. chiangmuanensis is older, displays more primitive dental characters, and shares several dental characters with the Late Miocene form. It is therefore interpreted as its probable ancestor. But its less enlarged M3 and more wrinkled enamel may suggest an even closer phylogenetic position to orangutan ancestors, which cannot yet be supported because of the incomplete fossil record. Thus Khoratpithecus represents a new lineage of Southeast Asian hominoids, closely related to extant great ape ancestors.


Assuntos
Fósseis , Hominidae/anatomia & histologia , Mandíbula/anatomia & histologia , Dente/anatomia & histologia , Animais , Antropologia Física , Evolução Biológica , Dentição Permanente , Meio Ambiente , Processamento de Imagem Assistida por Computador , Mandíbula/diagnóstico por imagem , Radiografia , Tailândia , Dente/diagnóstico por imagem
20.
J Appl Physiol (1985) ; 100(6): 1964-73, 2006 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-16469938

RESUMO

We studied the kinetics of proximal and distal bronchial response to histamine aerosol in healthy anesthetized and mechanically ventilated rabbits up to 60 min after histamine administration using a novel xenon-enhanced synchrotron radiation computed tomography imaging technique. Individual proximal airway constriction was assessed by measuring the luminal cross-sectional area. Distal airway obstruction was estimated by measuring the ventilated alveolar area after inhaled xenon administration. Respiratory system conductance was assessed continuously. Proximal airway cross-sectional area decreased by 57% of the baseline value by 20 min and recovered gradually but incompletely within 60 min. The ventilated alveolar area decreased immediately after histamine inhalation by 55% of baseline value and recovered rapidly thereafter. The results indicate that the airway reaction to inhaled histamine and the subsequent recovery are significantly slower in proximal than in distal bronchi in healthy rabbit. The findings suggest that physiological reaction mechanisms to inhaled histamine in the airway walls of large and small bronchi are not similar.


Assuntos
Histamina/farmacologia , Alvéolos Pulmonares/fisiologia , Ventilação Pulmonar/fisiologia , Tomografia Computadorizada por Raios X/métodos , Administração por Inalação , Obstrução das Vias Respiratórias/diagnóstico , Obstrução das Vias Respiratórias/patologia , Obstrução das Vias Respiratórias/fisiopatologia , Animais , Asma/patologia , Asma/fisiopatologia , Fenômenos Biomecânicos , Brônquios/anatomia & histologia , Brônquios/fisiologia , Broncoconstrição/efeitos dos fármacos , Broncoconstrição/fisiologia , Histamina/administração & dosagem , Histamina/farmacocinética , Processamento de Imagem Assistida por Computador , Masculino , Alvéolos Pulmonares/anatomia & histologia , Alvéolos Pulmonares/efeitos dos fármacos , Coelhos , Síncrotrons , Volume de Ventilação Pulmonar/fisiologia , Fatores de Tempo , Xenônio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...