Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Adsorption (Boston) ; 22(7): 993-1000, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-32269424

RESUMO

Determining structure-transport relationships is critical to optimising the activity and selectivity performance of porous pellets acting as heterogeneous catalysts for diffusion-limited reactions. For amorphous porous systems determining the impact of particular aspects of the void space on mass transport often requires complex characterization and modelling steps to deconvolve the specific influence of the feature in question. These characterization and modelling steps often have limited accuracy and precision. It is the purpose of this work to present a case-study demonstrating the use of a more direct experimental evaluation of the impact of pore network features on mass transport. The case study evaluated the efficacy of the macropores of a bidisperse porous foam structure on improving mass transport over a purely mesoporous system. The method presented involved extending the novel integrated gas sorption and mercury porosimetry method to include uptake kinetics. Results for the new method were compared with those obtained by the alternative NMR cryodiffusometry technique, and found to lead to similar conclusions. It was found that the experimentally-determined degree of influence of the foam macropores was in line with expectations from a simple resistance model for a disconnected macropore network.

2.
J Colloid Interface Sci ; 426: 72-9, 2014 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-24863767

RESUMO

The typical approach to analysing raw data, from common pore characterization methods such as gas sorption and mercury porosimetry, to obtain pore size distributions for disordered porous solids generally makes several critical assumptions that impact the accuracy of the void space descriptors thereby obtained. These assumptions can lead to errors in pore size of as much as 500%. In this work, we eliminated these assumptions by employing novel experiments involving fully integrated gas sorption, mercury porosimetry and mercury thermoporometry techniques. The entrapment of mercury following porosimetry allowed the isolation (for study) of a particular subset of pores within a much larger interconnected network. Hence, a degree of specificity of findings to particular pores, more commonly associated with use of templated, model porous solids, can also be achieved for disordered materials. Gas sorption experiments were conducted in series, both before and after mercury porosimetry, on the same sample, and the mercury entrapped following porosimetry was used as the probe fluid for theromporometry. Hence, even if one technique, on its own, is indirect, requiring unsubstantiated assumptions, the fully integrated combination of techniques described here permits the validation of assumptions used in one technique by another. Using controlled-pore glasses as model materials, mercury porosimetry scanning curves were used to establish the correct correspondence between the appropriate Gibbs-Thomson parameter, and the nature of the meniscus geometry in melting, for thermoporometry measurements on entrapped mercury. Mercury thermoporometry has been used to validate the pore sizes, for a series of sol-gel silica materials, obtained from mercury porosimetry data using the independently-calibrated Kloubek correlations. The pore sizes obtained for sol-gel silicas from porosimetry and thermoporometry have been shown to differ substantially from those obtained via gas sorption and NLDFT analysis. DRIFTS data for the samples studied has suggested that the cause of this discrepancy may arise from significant differences in the surface chemistries between the samples studied here and that used to calibrate the NLDFT potentials.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...