1.
Artif Organs ; 44(6): 584-593, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31912510

RESUMO

With the incidence of end-stage heart failure steadily increasing, the need for a practical total artificial heart (TAH) has never been greater. Continuous flow TAHs (CFTAH) are being developed using rotary blood pumps (RBPs), leveraging their small size, mechanical simplicity, and excellent durability. To completely replace the heart with currently available RBPs, two are required; one for providing pulmonary flow and one for providing systemic flow. To prevent hazardous states, it is essential to maintain balance between the pulmonary and systemic circulation at a wide variety of physiologic states. In this study, we investigated factors determining a CFTAH's inherent ability to balance systemic and pulmonary flow passively, without active management of pump rotational speed. Four different RBPs (ReliantHeart HA5, Thoratec HMII, HeartWare HVAD, and Ventracor VentrAssist) were used in various combinations to construct CFTAHs. Each CFTAH's ability to autonomously maintain pressures and flows within defined ranges was evaluated in a hybrid mock loop as systemic and pulmonary vascular resistance (PVR) were changed. The resistance box, a method to quantify the range of vascular resistances that can be safely supported by a CFTAH, was used to compare different CFTAH configurations in an efficient and predictive way. To reduce the need for future in vitro tests and to aid in their analysis, a novel analytical evaluation to predict the resistance box of various CFTAH configurations was also performed. None of the investigated CFTAH configurations fully satisfied the predefined benchmarks for inherent flow balancing, with the VentrAssist (left) and HeartAssist 5 (right) offering the best combination. The extent to which each CFTAH was able to autonomously maintain balance was determined by the pressure sensitivity of each RPB: the sensitivity of outflow to changes in the pressure head. The analytical model showed that by matching left and right pressure sensitivity the inherent balancing performance can be improved. These findings may ultimately lead to a reduced need for manual speed changes or active control systems.


Assuntos
Circulação Sanguínea/fisiologia , Desenho de Equipamento , Insuficiência Cardíaca/cirurgia , Coração Artificial , Modelos Cardiovasculares , Hemodinâmica/fisiologia , Humanos , Circulação Pulmonar
2.
Artif Organs ; 44(3): E40-E53, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31520408

RESUMO

Due to improved durability and survival rates, rotary blood pumps (RBPs) are the preferred left ventricular assist device when compared to volume displacement pumps. However, when operated at constant speed, RBPs lack a volume balancing mechanism which may result in left ventricular suction and suboptimal ventricular unloading. Starling-like controllers have previously been developed to balance circulatory volumes; however, they do not consider ventricular workload as a feedback and may have limited sensitivity to adjust RBP workload when ventricular function deteriorates or improves. To address this, we aimed to develop a Starling-like total work controller (SL-TWC) that matched the energy output of a healthy heart by adjusting RBP hydraulic work based on measured left ventricular stroke work and ventricular preload. In a mock circulatory loop, the SL-TWC was evaluated using a HeartWare HVAD in a range of simulated patient conditions. These conditions included changes in systemic hypertension and hypotension, pulmonary hypertension, blood circulatory volume, exercise, and improvement and deterioration of ventricular function by increasing and decreasing ventricular contractility. The SL-TWC was compared to constant speed control where RBP speed was set to restore cardiac output to 5.0 L/min at rest. Left ventricular suction occurred with constant speed control during pulmonary hypertension but was prevented with the SL-TWC. During simulated exercise, the SL-TWC demonstrated reduced LVSW (0.51 J) and greater RBP flow (9.2 L/min) compared to constant speed control (LVSW: 0.74 J and RBP flow: 6.4 L/min). In instances of increased ventricular contractility, the SL-TWC reduced RBP hydraulic work while maintaining cardiac output similar to the rest condition. In comparison, constant speed overworked and increased cardiac output. The SL-TWC balanced circulatory volumes by mimicking the Starling mechanism, while also considering changes in ventricular workload. Compared to constant speed control, the SL-TWC may reduce complications associated with volume imbalances, adapt to changes in ventricular function and improve patient quality of life.


Assuntos
Simulação por Computador , Coração Auxiliar , Modelos Cardiovasculares , Função Ventricular Esquerda , Desenho de Equipamento , Exercício Físico , Hemodinâmica , Humanos
3.
Artif Organs ; 42(1): 31-40, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28741841

RESUMO

Right ventricular failure is a common complication associated with rotary left ventricular assist device (LVAD) support. Currently, there is no clinically approved long-term rotary right ventricular assist device (RVAD). Instead, clinicians have implanted a second rotary LVAD as RVAD in biventricular support. To prevent pulmonary hypertension, the RVAD must be operated by either reducing pump speed or banding the outflow graft. These modes differ in hydraulic performance, which may affect the pulmonary valve opening (PVO) and subsequently cause fusion, valvular insufficiency, and thrombus formation. This study aimed to compare PVO with the RVAD operated at reduced speed or with a banded outflow graft. Baseline conditions of systemic normal, hypo, and hypertension with severe biventricular failure were simulated in a mock circulation loop. Biventricular support was provided with two rotary VentrAssist LVADs with cardiac output restored to 5 L/min in banded outflow and reduced speed conditions, and systemic and pulmonary vascular resistances (PVR) were manipulated to determine the range of conditions that allowed PVO without causing left ventricular suction. Finally, RVAD sine wave speed modulation (±550 rpm) strategies (co- and counter-pulsation) were implemented to observe the effect on PVO. For each condition, outflow banding had higher PVR (97 ± 20 dyne/s/cm5 higher) for when the pulmonary valve closed compared to reduced speed. In addition, counter-pulsation demonstrated greater PVO than co-pulsation and constant speed. For the purpose of reducing the risks of pulmonary valve insufficiency, fusion, and thrombotic event, this study recommends a RVAD with a steeper H-Q gradient by banding and further exploration of RVAD speed modulation.


Assuntos
Suporte Vital Cardíaco Avançado/métodos , Insuficiência Cardíaca/cirurgia , Coração Auxiliar/efeitos adversos , Modelos Cardiovasculares , Enxerto Vascular/métodos , Suporte Vital Cardíaco Avançado/efeitos adversos , Suporte Vital Cardíaco Avançado/instrumentação , Insuficiência Cardíaca/complicações , Ventrículos do Coração/fisiopatologia , Ventrículos do Coração/cirurgia , Humanos , Hipertensão Pulmonar/etiologia , Hipertensão Pulmonar/fisiopatologia , Hipertensão Pulmonar/prevenção & controle , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/fisiopatologia , Complicações Pós-Operatórias/prevenção & controle , Artéria Pulmonar/fisiopatologia , Artéria Pulmonar/transplante , Valva Pulmonar/fisiopatologia , Valva Pulmonar/cirurgia , Resistência Vascular , Disfunção Ventricular Direita/etiologia , Disfunção Ventricular Direita/fisiopatologia , Disfunção Ventricular Direita/prevenção & controle
4.
Ann Biomed Eng ; 45(3): 567-579, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-27543069

RESUMO

The successful clinical applicability of rotary left ventricular assist devices (LVADs) has led to research interest in devising a total artificial heart (TAH) using two rotary blood pumps (RBPs). The major challenge when using two separately controlled LVADs for TAH support is the difficulty in maintaining the balance between pulmonary and systemic blood flows. In this study, a starling-like controller (SLC) hybridized with an adaptive mechanism was developed for a dual rotary LVAD TAH. The incorporation of the adaptive mechanism was intended not only to minimize the risk of pulmonary congestion and atrial suction but also to match cardiac demand. A comparative assessment was performed between the proposed adaptive starling-like controller (A-SLC) and a conventional SLC as well as a constant speed controller. The performance of all controllers was evaluated by subjecting them to three simulated scenarios [rest, exercise, head up tilt (HUT)] using a mock circulation loop. The overall results showed that A-SLC was superior in matching pump flow to cardiac demand without causing hemodynamic instabilities. In contrast, improper flow regulation by the SLC resulted in pulmonary congestion during exercise. From resting supine to HUT, overpumping of the RBPs at fixed speed (FS) caused atrial suction, whereas implementation of SLC resulted in insufficient flow. The comparative study signified the potential of the proposed A-SLC for future TAH implementation particularly among outpatients, who are susceptible to variety of clinical scenarios.


Assuntos
Coração Artificial , Coração Auxiliar , Humanos
5.
Artif Organs ; 40(9): 824-33, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27645393

RESUMO

Unlike the earlier reciprocating volume displacement-type pumps, rotary blood pumps (RBPs) typically operate at a constant rotational speed and produce continuous outflow. When RBP technology is used in constructing a total artificial heart (TAH), the pressure waveform that the TAH produces is flat, without the rise and fall associated with a normal arterial pulse. Several studies have suggested that pulseless circulation may impair microcirculatory perfusion and the autoregulatory response and may contribute to adverse events such as gastrointestinal bleeding, arteriovenous malformations, and pump thrombosis. It may therefore be beneficial to attempt to reproduce pulsatile output, similar to that generated by the native heart, by rapidly modulating the speed of an RBP impeller. The choice of an appropriate speed profile and control strategy to generate physiologic waveforms while minimizing power consumption and blood trauma becomes a challenge. In this study, pump operation modes with six different speed profiles using the BiVACOR TAH were evaluated in vitro. These modes were compared with respect to: hemodynamic pulsatility, which was quantified as surplus hemodynamic energy (SHE); maximum rate of change of pressure (dP/dt); pulse power index; and motor power consumption as a function of pulse pressure. The results showed that the evaluated variables underwent different trends in response to changes in the speed profile shape. The findings indicated a possible trade-off between SHE levels and flow rate pulsatility related to the relative systolic duration in the speed profile. Furthermore, none of the evaluated measures was sufficient to fully characterize hemodynamic pulsatility.


Assuntos
Coração Artificial , Hemodinâmica , Modelos Cardiovasculares , Pressão Sanguínea , Desenho de Equipamento , Coração Artificial/economia , Humanos , Microcirculação , Pressão , Fluxo Pulsátil
6.
Artif Organs ; 38(9): 775-82, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25234760

RESUMO

Rotary blood pumps are emerging as a viable technology for total artificial hearts, and the development of physiological control algorithms is accelerated with new evaluation environments. In this article, we present a novel hybrid mock circulation loop (HMCL) designed specifically for evaluation of rotary total artificial hearts (rTAH). The rTAH is operated in the physical domain while all vasculature elements are embedded in the numerical domain, thus combining the strengths of both approaches: fast and easy exchange of the vasculature model together with improved controllability of the pump. Parameters, such as vascular resistance, compliance, and blood volume, can be varied dynamically in silico during operation. A hydraulic-numeric interface creates a real-time feedback loop between the physical and numerical domains. The HMCL uses computer-controlled resistance valves as actuators, thereby reducing the size and number of hydraulic elements. Experimental results demonstrate a stable interaction over a wide operational range and a high degree of flexibility. Therefore, we demonstrate that the newly created design environment can play an integral part in the hydraulic design, control development, and durability testing of rTAHs.


Assuntos
Coração Artificial , Volume Sanguíneo , Simulação por Computador , Desenho de Equipamento , Retroalimentação , Humanos , Modelos Cardiovasculares , Software , Resistência Vascular
7.
Cytokine ; 70(2): 173-8, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25148723

RESUMO

In order to examine the immunomodulatory effects of antithrombin III (AT-III) and C1 esterase inhibitor (C1-INH) in human monocytes, we investigated the intracellular expression of interleukin (IL)-6, IL-8, and tumor necrosis factor (TNF)-α in an ex-vivo laboratory study in a whole blood setting. Heparinized whole blood samples from 23 healthy male and female volunteers (mean age: 27±7years) were pre-incubated with clinically relevant concentrations of AT-III (n=11) and C1-INH (n=12), then stimulated with 0.2 ng/mL lipopolysaccharide (LPS) for 3h. After phenotyping CD14⁺ monocytes, intracellular expression of IL-6, IL-8, and TNF-α was assessed using flow cytometry. In addition, 12 whole blood samples (AT-III and C1-INH, n=6 each) were examined using hirudin for anticoagulation; all samples were processed in the same way. To exclude cytotoxicity effects, 7-amino-actinomycin D and Nonidet P40 staining were used to investigate probes. This study is the first to demonstrate the influence of C1-INH and AT-III on the monocytic inflammatory response in a whole blood setting, which mimics the optimal physiological setting. Cells treated with AT-III exhibited significant downregulation of the proportion of gated CD14⁺ monocytes for IL-6 and IL-8, in a dose-dependent manner; downregulation for TNF-α did not reach statistical significance. There were no significant effects on mean fluorescence intensity (MFI). In contrast, C1-INH did not significantly reduce the proportion of gated CD14⁺ monocytes or the MFI regarding IL-6, TNF-α, and IL-8. When using hirudin for anticoagulation, no difference in the anti-inflammatory properties of AT-III and C1-INH in monocytes occurs. Taken together, in contrast to TNF-α, IL-6 and IL-8 were significantly downregulated in monocytes in an ex-vivo setting of human whole blood when treated with AT-III. This finding implicates monocytes as an important point of action regarding the anti-inflammatory properties of AT-III in sepsis. C1-INH was unable to attenuate the monocytic response, which supports the hypothesis that other cellular components in whole blood (e.g., neutrophils) might be responsible for the known effects of C1-INH in inflammation.


Assuntos
Antitrombina III/farmacologia , Proteína Inibidora do Complemento C1/farmacologia , Inflamação/sangue , Inflamação/patologia , Lipopolissacarídeos/farmacologia , Monócitos/patologia , Adulto , Anticoagulantes/farmacologia , Morte Celular/efeitos dos fármacos , Feminino , Hirudinas/farmacologia , Humanos , Masculino , Monócitos/efeitos dos fármacos , Adulto Jovem
8.
Artif Organs ; 38(11): 931-9, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24660783

RESUMO

Dual rotary left ventricular assist devices (LVADs) have been used clinically to support patients with biventricular failure. However, due to the lower vascular resistance in the pulmonary circulation compared with its systemic counterpart, excessively high pulmonary flow rates are expected if the right ventricular assist device (RVAD) is operated at its design LVAD speed. Three possible approaches are available to match the LVAD to the pulmonary circulation: operating the RVAD at a lower speed than the LVAD (mode 1), operating both pumps at their design speeds (mode 2) while relying on the cardiovascular system to adapt, and operating both pumps at their design speeds while restricting the diameter of the RVAD outflow graft (mode 3). In this study, each mode was characterized using in vitro and in vivo models of biventricular heart failure supported with two VentrAssist LVADs. The effect of each mode on arterial and atrial pressures and flow rates for low, medium, and high vascular resistances and three different contractility levels were evaluated. The amount of speed/diameter adjustment required to accommodate elevated pulmonary vascular resistance (PVR) during support with mode 3 was then investigated. Mode 1 required relatively low systemic vascular resistance to achieve arterial pressures less than 100 mm Hg in vitro, resulting in flow rates greater than 6 L/min. Mode 2 resulted in left atrial pressures above 25 mm Hg, unless left heart contractility was near-normal. In vitro, mode 3 resulted in expected arterial pressures and flow rates with an RVAD outflow diameter of 6.5 mm. In contrast, all modes were achievable in vivo, primarily due to higher RVAD outflow graft resistance (more than 500 dyn·s/cm(5)), caused by longer cannula. Flow rates could be maintained during instances of elevated PVR by increasing the RVAD speed or expanding the outflow graft diameter using an externally applied variable graft occlusion device. In conclusion, suitable hemodynamics could be produced by either restricting or not restricting the right outflow graft diameter; however, the latter required an operation of the RVAD at lower than design speed. Adjustments in outflow restriction and/or RVAD speed are recommended to accommodate varying PVR.


Assuntos
Coração Auxiliar , Disfunção Ventricular Direita/terapia , Animais , Desenho de Equipamento , Feminino , Hemodinâmica , Técnicas In Vitro , Modelos Cardiovasculares , Carneiro Doméstico , Resistência Vascular/fisiologia , Disfunção Ventricular Direita/fisiopatologia
9.
Artif Organs ; 38(3): 182-90, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23902580

RESUMO

The accurate representation of rotary blood pumps in a numerical environment is important for meaningful investigation of pump-cardiovascular system interactions. Although numerous models for ventricular assist devices (VADs) have been developed, modeling methods for rotary total artificial hearts (rTAHs) are still required. Therefore, an rTAH prototype was characterized in a steady flow, hydraulic test bench over a wide operational range for pump and hydraulic parameters. In order to develop a generic modeling method, a data-driven modeling approach was chosen. k-Nearest-neighbors, artificial neural networks, and support vector machines (SVMs) were the machine learning approaches evaluated. The best performing parameters for each algorithm were determined via optimization. The resulting multiple-input-multiple-output models were subsequently assessed under identical conditions, and a SVM with a radial basis function kernel was identified as the best performing. The achieved root mean squared errors were 0.03 L/min, 0.06 L/min, and 0.18 W for left and right flow and motor power consumption, respectively. In comparison with existing models for VADs, the flow errors are more than 70% lower. Further advantages of the SVM model are the robustness to measurement noise and the capability to operate outside of the trained parameter range. This proposed modeling method will accelerate further device refinements by providing a more appropriate numerical environment in which to evaluate the pump-cardiovascular system interaction.


Assuntos
Coração Auxiliar , Modelos Cardiovasculares , Algoritmos , Desenho de Equipamento , Humanos
10.
Artigo em Inglês | MEDLINE | ID: mdl-25571281

RESUMO

A mock circulatory loop was constructed to facilitate total artificial heart development. The loop includes many novel features such as a pressure-regulated tank to simulate exercise conditions, controllable systemic and pulmonary vascular resistance to create left-right flow imbalances as seen in postural change and breathing, and a left atrial suction valve. Dual HeartMate II pumps and the BiVACOR® rotary total artificial heart were used to generate pressure and flow data characterizing the flow loop.


Assuntos
Coração Artificial , Modelos Cardiovasculares , Exercício Físico , Átrios do Coração , Humanos , Desenho de Prótese , Resistência Vascular
11.
Anesth Analg ; 101(6): 1805-1808, 2005 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16301262

RESUMO

In this ex vivo laboratory study, we investigated the effects of drotrecogin alfa (activated) (DA(a)), a recombinant form of human activated protein C, on the intracellular expression of interleukin (IL)-6 and tumor necrosis factor (TNF)-alpha on lipopolysaccharide (LPS)-stimulated human monocytes in a whole blood system. Whole blood samples from 10 healthy volunteers were stimulated with LPS (0.2 ng/mL) and incubated with 0.01, 0.1, 1, 10, and 100 nM of (final concentration) DA(a) for 3 h at 37 degrees C and 5% CO2. Intracellular expression of IL-6 and TNF-alpha was assessed by flow cytometry. Our investigation showed that DA(a), at any of the concentrations tested, did not affect intracellular IL-6 and TNF-alpha production in LPS-stimulated human monocytes after 3 h of incubation. The results of this investigation led us to conclude that any antiinflammatory activity of DA(a), if present, does not occur via detectible decreases in the production of proinflammatory cytokines IL-6 and TNF-alpha in human monocytes.


Assuntos
Anti-Inflamatórios não Esteroides/farmacologia , Interleucina-6/biossíntese , Lipopolissacarídeos/farmacologia , Monócitos/efeitos dos fármacos , Proteína C/farmacologia , Fator de Necrose Tumoral alfa/biossíntese , Adulto , Relação Dose-Resposta a Droga , Humanos , Monócitos/metabolismo , Proteínas Recombinantes/farmacologia