Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Surg Obes Relat Dis ; 15(8): 1241-1251, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31262650

RESUMO

BACKGROUND: The management of laparoscopic sleeve gastrectomy leaks remains a challenge. This can be treated with placement of self-expandable metal stents, which are most effective in the acute and early settings. However, migration is a frequent adverse event (AE). Novel, fully covered stents with a larger proximal flare to limit migration designed specifically to treat postsleeve leaks were recently introduced. OBJECTIVES: The aim of this study was to evaluate the safety and efficacy of a novel stent specifically designed for postsleeve leaks treatment. SETTING: Multicenter retrospective study. METHODS: This is a multicenter study, including patients with acute and early post laparoscopic sleeve gastrectomy leaks, treated with a large bariatric stent. The outcomes include technical success, clinical success, and safety profile. A multivariable regression was performed to assess predictors of success. RESULTS: Thirty-seven patients were included (10 acute and 27 early leaks), with 30 stents in the postpyloric (POST) and 7 in the prepyloric position. Technical success was 100%. Mean stent dwell time was 29.08 days. Clinical success was achieved in 78.37%. Leak duration, leak size, and stent dwell time did not correlate with clinical success. During follow-up, 8 patients had stent migration (21.62%) and all were in a POST position. AE poststent removal were also evaluated (prepyloric: 57.14% vs POST: 33.3%, P = .45). There was no difference between prepyloric and POST position in the severe AE analysis. CONCLUSIONS: This novel, large-caliber, fully covered stent specifically designed for sleeve leaks appears to be effective at treating acute and early leaks. However, the large flanges and long stent length do not appear to reduce migration rate and may be associated with higher overall severe AE rates. Avoiding placement in the POST position may help mitigate migration risk; however, owing to the risk profile this stent should be used with caution.


Assuntos
Fístula Anastomótica/epidemiologia , Cirurgia Bariátrica , Gastrectomia , Adulto , Cirurgia Bariátrica/efeitos adversos , Cirurgia Bariátrica/instrumentação , Cirurgia Bariátrica/estatística & dados numéricos , Feminino , Gastrectomia/efeitos adversos , Gastrectomia/instrumentação , Gastrectomia/estatística & dados numéricos , Humanos , Masculino , Pessoa de Meia-Idade , Obesidade Mórbida/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...