Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
Int J Emerg Med ; 17(1): 70, 2024 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-38822267

RESUMO

This manuscript is a consensus document of an expert panel on the Evaluation and Treatment of Gastrointestinal Bleeding in Patients Taking Anticoagulants Presenting to the Emergency Department, sponsored by the American College of Emergency Physicians.

2.
Adv Ther ; 40(3): 1204-1223, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36652174

RESUMO

INTRODUCTION: Older patients are at increased risk for hyperkalemia (HK). This study describes the prevalence, recurrence, and clinical and economic burden of HK in Medicare patients admitted to a long-term care (LTC) setting. METHODS: Retrospective cohort study using 100% Medicare Fee-for-Service (FFS) claims identified patients aged ≥ 65 years with index admission between 2017 and 2019 to a LTC setting (skilled nursing, home health, inpatient rehabilitation, or long-term acute care). Beneficiaries were required to have 12 months continuous medical and pharmacy coverage prior to index LTC admission and ≥ 30 days after LTC discharge (follow-up). Patient characteristics, healthcare resource utilization, and costs were assessed. HK was defined as ICD-10 diagnosis code E87.5 in any claim position or Medicare Part D fill for oral potassium binder. RESULTS: Of 4,562,231 patients with a LTC stay, the prevalence of HK was 14.7% over the full study period (pre-index, index stay, and follow-up). Excluding those with HK only during the follow-up period resulted in 4,081,103 patients. Of these, 290,567 (7.1%) had HK and 3,790,536 (92.9%) did not have HK during or within 14 days prior to index LTC stay. The HK recurrence rate during index stay and follow-up was 48.3%. Unmatched HK versus non-HK patients were more often male (43.0% vs. 35.4%), Black (13.5% vs. 8.0%), dual eligible for Medicaid (34.2% vs. 25.0%), with higher mean Charlson Comorbidity Index scores (6.2 vs. 3.9) (all p < 0.0001). After propensity matching, HK patients were 2.2 times more likely to be hospitalized, with higher mortality (30.8% vs. 21.5%) and higher total healthcare costs during both index stay (US$26,520 vs. $18,021; p < 0.0011) and follow-up ($57,948 vs. $41,744 (p < 0.0011) versus matched non-HK patients. CONCLUSION: Prevalence and recurrence of HK was high among LTC patients, and HK was associated with significantly greater clinical and economic burden during and post-LTC.


Hyperkalemia is a serious medical condition commonly occurring in nursing home residents. It is characterized by abnormally high blood levels of potassium that if untreated can be life-threatening. High levels of potassium can be the result of kidney disease and inability to remove potassium from the bloodstream; eating foods high in potassium; and/or taking medications that interfere with the kidney's ability to remove potassium from the bloodstream. Older patients who have chronic kidney disease, heart failure, diabetes, and high blood pressure are at particularly high risk for hyperkalemia. Management is difficult as it requires reducing intake of foods high in potassium, adjusting medications that cause hyperkalemia, and potentially treating with oral potassium binders to reduce potassium blood levels. This study focused on the clinical outcomes, healthcare services use, and costs incurred by Medicare beneficiaries 65 years and older admitted to long-term care, where the occurrence of hyperkalemia is often high yet unrecognized. Patients with a diagnosis of hyperkalemia immediately before and during admission to long-term care or after discharge had an increased rate of death compared with patients without a hyperkalemia diagnosis. Hyperkalemia patients also had more hospitalizations and visits to the Emergency Department and outpatient facilities, resulting in higher total medical costs. Total costs for hyperkalemia patients were highest for those with chronic kidney disease, heart failure, and diabetes.


Assuntos
Hiperpotassemia , Medicare , Humanos , Idoso , Masculino , Estados Unidos/epidemiologia , Assistência de Longa Duração , Estudos Retrospectivos , Hiperpotassemia/epidemiologia , Estresse Financeiro , Custos de Cuidados de Saúde
3.
Clin Exp Emerg Med ; 9(1): 24-28, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35354231

RESUMO

OBJECTIVE: Remote cardiac implantable electronic device (CIED) interrogators, originally developed for home use, have been proven to be efficacious in clinical settings, especially emergency departments. Concern exists that attempting to interrogate a CIED with the remote interrogator of a different brand, i.e., a brand-mismatched interrogator, may cause device malfunction. The aim of this study was to determine if intentionally attempting to interrogate a CIED with a brand-mismatched remote interrogator resulted in device malfunction. METHODS: A total of 75 ex vivo CIEDs manufactured by various companies underwent attempted interrogation by a brand-mismatched remote interrogator. CIED settings were compared before and after attempted mismatch interrogation. A total of 30 in vivo CIEDs were then randomized for an attempted 2-minute mismatched remote interrogation by one of the two possible mismatched remote interrogators. CIED settings were compared before and after attempted mismatch interrogation. RESULTS: Of 150 ex vivo brand-mismatched interrogations, no device setting changes or malfunctions occurred; no remote interrogators connected to a mismatched CIED, and no devices were turned off. In the 30 patients undergoing brand-mismatched interrogations, the mean (standard deviation) age was 71.6 ( ± 14.7) years, 16 (53%) were male, with 24 pacemakers (80%), four pacemaker/implantable cardioverter defibrillators (13%), and two implantable cardioverter defibrillators (7%). Of the 30 mismatched interrogations performed, no device setting changes or malfunctions occurred; no remote interrogators connected to a mismatched CIED, and no devices turned off. CONCLUSION: In a total 180 attempted brand-mismatched CIED interrogations, no CIED malfunctions occurred. This suggests that the use of remote CIED interrogators when device manufacturer is unknown is unlikely to result in adverse CIED-related events.

4.
Am J Emerg Med ; 51: 427.e1-427.e2, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34294502

RESUMO

There have been more than 178 million global cases of COVID-19, the disease caused by the SARS-CoV-2 virus, with more than 3.8 million deaths worldwide [1]. COVID-19 can present with a wide variety of symptoms, and one rare manifestation that has been reported in the literature is acute epiglottitis. To date, there have been two reported cases of acute epiglottitis in COVID-19 positive patients [2, 3]. We present a case of a 49-year-old male presenting to a community emergency department with the chief complaint of dysphagia and sore throat, confirmed as acute epiglottitis, in the presence of a positive rapid COVID-19 PCR test.


Assuntos
COVID-19/diagnóstico , Epiglotite/diagnóstico , Doença Aguda , Transtornos de Deglutição/virologia , Epiglotite/virologia , Humanos , Hipertensão , Masculino , Pessoa de Meia-Idade , Faringite/virologia , Síndrome de Wolff-Parkinson-White
5.
West J Emerg Med ; 22(6): 1270-1275, 2021 Sep 24.
Artigo em Inglês | MEDLINE | ID: mdl-34787550

RESUMO

INTRODUCTION: Recent studies from urban academic centers have shown the promise of emergency physician-initiated buprenorphine for improving outcomes in opioid use disorder (OUD) patients. We investigated whether emergency physician-initiated buprenorphine in a rural, community setting decreases subsequent healthcare utilization for OUD patients. METHODS: We performed a retrospective chart review of patients presenting to a community hospital emergency department (ED) who received a prescription for buprenorphine from June 15, 2018-June 15, 2019. Demographic and opioid-related International Classification of Diseases, 10th Revision, (ICD-10) codes were documented and used to create a case-matched control cohort of demographically matched patients who presented in a similar time frame with similar ICD-10 codes but did not receive buprenorphine. We recorded 12-month rates of ED visits, all-cause hospitalizations, and opioid overdoses. Differences in event occurrences between groups were assessed with Poisson regression. RESULTS: Overall 117 patients were included in the study: 59 who received buprenorphine vs 58 controls. The groups were well matched, both roughly 90% White and 60% male, with an average age of 33.4 years for both groups. Controls had a median two ED visits (range 0-33), median 0.5 hospitalizations (range 0-8), and 0 overdoses (range 0-3), vs median one ED visit (range 0-8), median 0 hospitalizations (range 0-4), and median 0 overdoses (range 0-3) in the treatment group. The incidence rate ratio (IRR) for counts of ED visits was 0.61, 95% confidence interval (CI), 0.49, 0.75, favoring medication-assisted treatment (MAT). For hospitalizations, IRR was 0.34, 95% CI, 0.22, 0.52 favoring MAT, and for overdoses was 1.04, 95% CI, 0.53, 2.07. CONCLUSION: Initiation of buprenorphine by ED providers was associated with lower 12-month ED visit and all-cause hospitalization rates with comparable overdose rates compared to controls. These findings show the ED's potential as an initiation point for medication-assisted treatment in OUD patients.


Assuntos
Buprenorfina , Transtornos Relacionados ao Uso de Opioides , Adulto , Buprenorfina/uso terapêutico , Estudos de Coortes , Atenção à Saúde , Serviço Hospitalar de Emergência , Feminino , Humanos , Masculino , Transtornos Relacionados ao Uso de Opioides/tratamento farmacológico , Prescrições , Estudos Retrospectivos
6.
J Am Coll Emerg Physicians Open ; 2(5): e12572, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34632453

RESUMO

Hyperkalemia is a common electrolyte abnormality identified in the emergency department (ED) and potentially fatal. However, there is no consensus over the potassium threshold that warrants intervention or its treatment algorithm. Commonly used medications are at best temporizing measures, and the roles of binders are unclear in the emergent setting. As the prevalence of comorbid conditions altering potassium homeostasis rises, hyperkalemia becomes more common, and hence there is a need to standardize management. A panel was assembled to synthesize the available evidence and identify gaps in knowledge in hyperkalemia treatment in the ED. The panel was composed of 7 medical practitioners, including 5 physicians, a nurse, and a clinical pharmacist with collective expertise in the areas of emergency medicine, nephrology, and hospital medicine. This panel was sponsored by the American College of Emergency Physicians with a goal to create a consensus document for managing acute hyperkalemia. The panel evaluated the evidence on calcium for myocyte stabilization and potassium shifting and excretion. This article summarizes information on available therapies for hyperkalemia and proposes a hyperkalemia treatment algorithm for the ED practitioner based on the currently available literature and highlights diagnostic pitfalls and evidence gaps.

9.
Ann Lab Med ; 36(5): 405-12, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27374704

RESUMO

BACKGROUND: We aimed to compare the diagnostic accuracy of the Alere Triage Cardio3 Tropinin I (TnI) assay (Alere, Inc., USA) and the PathFast cTnI-II (Mitsubishi Chemical Medience Corporation, Japan) against the central laboratory assay Singulex Erenna TnI assay (Singulex, USA). METHODS: Using the Markers in the Diagnosis of Acute Coronary Syndromes (MIDAS) study population, we evaluated the ability of three different assays to identify patients with acute myocardial infarction (AMI). The MIDAS dataset, described elsewhere, is a prospective multicenter dataset of emergency department (ED) patients with suspected acute coronary syndrome (ACS) and a planned objective myocardial perfusion evaluation. Myocardial infarction (MI) was diagnosed by central adjudication. RESULTS: The C-statistic with 95% confidence intervals (CI) for diagnosing MI by using a common population (n=241) was 0.95 (0.91-0.99), 0.95 (0.91-0.99), and 0.93 (0.89-0.97) for the Triage, Singulex, and PathFast assays, respectively. Of samples with detectable troponin, the absolute values had high Pearson (R(P)) and Spearman (R(S)) correlations and were R(P)=0.94 and R(S)=0.94 for Triage vs Singulex, R(P)=0.93 and R(S)=0.85 for Triage vs PathFast, and R(P)=0.89 and R(S)=0.73 for PathFast vs Singulex. CONCLUSIONS: In a single comparative population of ED patients with suspected ACS, the Triage Cardio3 TnI, PathFast, and Singulex TnI assays provided similar diagnostic performance for MI.


Assuntos
Síndrome Coronariana Aguda/diagnóstico , Sistemas Automatizados de Assistência Junto ao Leito , Troponina I/análise , Biomarcadores/análise , Serviço Hospitalar de Emergência , Humanos , Laboratórios/normas , Infarto do Miocárdio/diagnóstico , Estudos Prospectivos , Kit de Reagentes para Diagnóstico , Sensibilidade e Especificidade
10.
Clin Exp Emerg Med ; 3(4): 239-244, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28168230

RESUMO

OBJECTIVE: Patients with implanted cardiac devices may wait extended periods for interrogation in emergency departments (EDs). Our purpose was to determine if device interrogation could be done safely and faster by ED staff. METHODS: Prospective randomized, standard therapy controlled, trial of ED staff device interrogation vs. standard process (SP), with 30-day follow-up. Eligibility criteria: ED presentation with a self-report of a potential device related complaint, with signed informed consent. SP interrogation was by company representative or hospital employee. RESULTS: Of 60 patients, 42 (70%) were male, all were white, with a median (interquartile range) age of 71 (64 to 82) years. No patient was lost to follow up. Of all patients, 32 (53%) were enrolled during business hours. The overall median (interquartile range) ED vs. SP time to interrogation was 98.5 (40 to 260) vs. 166.5 (64 to 412) minutes (P=0.013). While ED and SP interrogation times were similar during business hours, 102 (59 to 138) vs. 105 (64 to 172) minutes (P=0.62), ED interrogation times were shorter vs. SP during non-business hours; 97 (60 to 126) vs. 225 (144 to 412) minutes, P=0.002, respectively. There was no difference in ED length of stay between the ED and SP interrogation, 249 (153 to 390) vs. 246 (143 to 333) minutes (P=0.71), regardless of time of presentation. No patient in any cohort suffered an unplanned medical contact or post-discharge adverse device related event. CONCLUSION: ED staff cardiac device interrogations are faster, and with similar 30-day outcomes, as compared to SP.

12.
Crit Pathw Cardiol ; 13(1): 6-8, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24526144

RESUMO

BACKGROUND: Implanted devices (eg, pacemakers and defibrillators) provide valuable information and may be interrogated to obtain diagnostic information and to direct management. During admission to an emergency department (ED), significant time and cost are spent waiting for device manufacturer representatives or cardiologists to access the data. If ED personnel could safely interrogate implanted devices, more rapid disposition could occur, thus leading to potentially better outcomes at a reduced cost. This was a pilot study examining the feasibility of ED device interrogation. METHODS: This was a prospective convenience sample study of patients presenting to the ED with any chief complaint and who had an implantable device capable of being interrogated by a Medtronic reader. After obtaining informed consent, study patients underwent device interrogation by ED research personnel. After reviewing the device data, the physician documented their opinions of the value of data in aiding care. Patients were followed up at intervals ranging from 30 days out to 1 year to determine adverse events relating to interrogation. RESULTS: Forty-four patients underwent device interrogation. Their mean age was 56 ± 14.7 years (range, 28-83), 75% (33/44) were male and 75% (33/44) were hospitalized from the ED. The interrogations took less than 10 minutes 89% of the time. In 60% of the cases, ED physicians reported the data-assisted patient care. No adverse events were reported relating to the ED interrogations. CONCLUSIONS: In this pilot study, we found that ED personnel can safely and quickly interrogate implantable devices to obtain potentially useful clinical data.


Assuntos
Desfibriladores Implantáveis/estatística & dados numéricos , Atenção à Saúde/métodos , Serviço Hospitalar de Emergência/estatística & dados numéricos , Admissão do Paciente/estatística & dados numéricos , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Viabilidade , Feminino , Pessoal de Saúde , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Estudos Prospectivos
13.
Int J Cardiol ; 168(2): 795-802, 2013 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-23117012

RESUMO

BACKGROUND: The HEART score and North American Chest Pain Rule (NACPR) are decision rules designed to identify acute chest pain patients for early discharge without stress testing or cardiac imaging. This study compares the clinical utility of these decision rules combined with serial troponin determinations. METHODS AND RESULTS: A secondary analysis was conducted of 1005 participants in the Myeloperoxidase In the Diagnosis of Acute coronary syndromes Study (MIDAS). MIDAS is a prospective observational cohort of Emergency Department (ED) patients enrolled from 18 US sites with symptoms suggestive of acute coronary syndrome (ACS). The ability to identify participants for early discharge and the sensitivity for ACS at 30 days were compared among an unstructured assessment, NACPR, and HEART score, each combined with troponin measures at 0 and 3h. ACS, defined as cardiac death, acute myocardial infarction, or unstable angina, occurred in 22% of the cohort. The unstructured assessment identified 13.5% (95% CI 11.5-16%) of participants for early discharge with 98% (95% CI 95-99%) sensitivity for ACS. The NACPR identified 4.4% (95% CI 3-6%) for early discharge with 100% (95% CI 98-100%) sensitivity for ACS. The HEART score identified 20% (95% CI 18-23%) for early discharge with 99% (95% CI 97-100%) sensitivity for ACS. The HEART score had a net reclassification improvement of 10% (95% CI 8-12%) versus unstructured assessment and 19% (95% CI 17-21%) versus NACPR. CONCLUSIONS: The HEART score with 0 and 3 hour serial troponin measures identifies a substantial number of patients for early discharge while maintaining high sensitivity for ACS.


Assuntos
Dor no Peito/diagnóstico , Dor no Peito/terapia , Tomada de Decisões , Serviço Hospitalar de Emergência/normas , Alta do Paciente/normas , Índice de Gravidade de Doença , Doença Aguda , Adulto , Idoso , Idoso de 80 Anos ou mais , Dor no Peito/epidemiologia , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Tempo
14.
Am Heart J ; 162(5): 893-9, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22093206

RESUMO

BACKGROUND: Myeloperoxidase (MPO) is proposed for risk stratification in patients with suspected acute coronary syndromes (ACSs). We determined if MPO has diagnostic value in patients being evaluated for ACS. METHOD: MIDAS was an 18-center prospective study enrolling suspected ACS emergency department patients who presented <8 hours after symptom onset and in whom serial cardiac markers and objective cardiac perfusion testing were planned. Blinded MPO (Biosite, Inc, San Diego, CA) and troponin I (Triage Cardio 3; Biosite, Inc) were drawn at arrival, and Troponin I (TnI) was measured at 90, 180, and 360 minutes. Final diagnoses were adjudicated by the local investigator blinded to study assay. RESULTS: Of 1,018 patients, 54% were male, 26% black, with a mean age of 58 ± 13 years. Diagnoses were ACS in 288 (23%) and noncardiac chest pain (NCCP) in 788 (77%). Of patients with ACS, 94 (9.2%) had a myocardial infarction (MI) at presentation (69 non-ST-elevation MI, 25 ST-elevation MI), and 136 had unstable angina. Using a cutpoint of 210 ng/mL to provide 90% specificity, MPO had a sensitivity of 0.18; negative predictive value, 0.69; positive predictive value, 0.47; negative likelihood ratio, 0.91; and a positive likelihood ratio of 1.83 to differentiate ACS and NCCP. Because of the large overlap of quartiles, MPO was not clinically useful to predict serial TnI changes. The C statistics ± 95% CI for MPO differentiating ACS from NCCP and for AMI versus NCCP were 0.629 ± 0.04 and 0.666 ± 0.06, respectively. CONCLUSIONS: Myeloperoxidase has insufficient accuracy for decision making in patients with suspected ACS.


Assuntos
Síndrome Coronariana Aguda/diagnóstico , Técnicas de Diagnóstico Cardiovascular/normas , Peroxidase/sangue , Síndrome Coronariana Aguda/complicações , Síndrome Coronariana Aguda/enzimologia , Idoso , Angina Pectoris/etiologia , Serviço Hospitalar de Emergência/estatística & dados numéricos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Curva ROC , Risco , Sensibilidade e Especificidade , Troponina I/sangue , Estados Unidos
16.
Heart Fail Clin ; 5(1): 63-73, vi-vii, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19026387

RESUMO

As more patients have pacemakers and internal cardioverter defibrillators implanted, and live longer with these and other life-extending therapies, the utility of these devices and the potential for malfunction become meaningful to physicians. This article presents a basic understanding of the reasons for implantation, how the devices function, and what to do to help improve patient care if a problem occurs.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca/terapia , Marca-Passo Artificial , Estimulação Cardíaca Artificial , Desfibriladores Implantáveis/efeitos adversos , Serviço Hospitalar de Emergência , Desenho de Equipamento , Falha de Equipamento , Humanos , Marca-Passo Artificial/efeitos adversos , Taquicardia/etiologia , Terminologia como Assunto , Ultrafiltração
17.
Crit Care Clin ; 23(4): 737-58, vi, 2007 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17964361

RESUMO

This article defines acute decompensated heart failure. Additionally, it lists common precipitating factors and the clinical presentation. Proper diagnostic technique is highlighted, as are possible treatments.


Assuntos
Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Doença Aguda , Algoritmos , Cardiotônicos/efeitos adversos , Cardiotônicos/uso terapêutico , Humanos , Alta do Paciente , Medição de Risco , Vasodilatadores/efeitos adversos , Vasodilatadores/uso terapêutico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...