Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 228
Filtrar
1.
Lancet Digit Health ; 6(3): e157-e165, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38395537

RESUMO

BACKGROUND: Studies on the effect of computer-aided detection (CAD) in a daily clinical screening and surveillance colonoscopy population practice are scarce. The aim of this study was to evaluate a novel CAD system in a screening and surveillance colonoscopy population. METHODS: This multicentre, randomised, controlled trial was done in ten hospitals in Europe, the USA, and Israel by 31 endoscopists. Patients referred for non-immunochemical faecal occult blood test (iFOBT) screening or surveillance colonoscopy were included. Patients were randomomly assigned to CAD-assisted colonoscopy or conventional colonoscopy; a subset was further randomly assigned to undergo tandem colonoscopy: CAD followed by conventional colonoscopy or conventional colonoscopy followed by CAD. Primary objectives included adenoma per colonoscopy (APC) and adenoma per extraction (APE). Secondary objectives included adenoma miss rate (AMR) in the tandem colonoscopies. The study was registered at ClinicalTrials.gov, NCT04640792. FINDINGS: A total of 916 patients were included in the modified intention-to-treat analysis: 449 in the CAD group and 467 in the conventional colonoscopy group. APC was higher with CAD compared with conventional colonoscopy (0·70 vs 0·51, p=0·015; 314 adenomas per 449 colonoscopies vs 238 adenomas per 467 colonoscopies; poisson effect ratio 1·372 [95% CI 1·068-1·769]), while showing non-inferiority of APE compared with conventional colonoscopy (0·59 vs 0·66; p<0·001 for non-inferiority; 314 of 536 extractions vs 238 of 360 extractions). AMR in the 127 (61 with CAD first, 66 with conventional colonoscopy first) patients completing tandem colonoscopy was 19% (11 of 59 detected during the second pass) in the CAD first group and 36% (16 of 45 detected during the second pass) in the conventional colonoscopy first group (p=0·024). INTERPRETATION: CAD increased adenoma detection in non-iFOBT screening and surveillance colonoscopies and reduced adenoma miss rates compared with conventional colonoscopy, without an increase in the resection of non-adenomatous lesions. FUNDING: Magentiq Eye.


Assuntos
Adenoma , Hominidae , Humanos , Animais , Colonoscopia , Adenoma/diagnóstico por imagem , Computadores , Europa (Continente)
2.
Epilepsy Behav ; 152: 109596, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38350362

RESUMO

PURPOSE: Our aim was to assess intelligence, visual perception and working memory in children with new-onset Rolandic epilepsy (RE) and children with Rolandic discharges without seizures (RD). METHODS: The participants in the study were 12 children with RE and 26 children with RD aged 4 to 10 years (all without medication and shortly after diagnosis) and 31 healthy controls. Their cognitive performance was assessed using the German versions of the Wechsler Preschool and Primary Scale of Intelligence (WPPSI-III), the Wechsler Intelligence Scale for Children (WISC-IV), the Developmental Test of Visual Perception-2 (DTVP-2), the Developmental Test of Visual Perception-Adolescent and Adult (DTVP-A) (each according to age) and the Word Order, Hand Movements and Spatial Memory subtests of the German version of the Kaufman Assessment Battery for Children (K-ABC). RESULTS: The comparison of the entire group of children with RE/RD and the control group conducted in the first step of our analysis revealed a weaker performance of the children with RE/RD in all cognitive domains. Significant deficits, however, were found exclusively in the RD group. Compared to the controls, they performed significantly weaker regarding IQ (full scale IQ: p < 0.001; verbal IQ: p < 0.001; performance IQ: p = 0.002; processing speed: p = 0.005), visual perception (general visual perception: p = 0.005; visual-motor integration: p = 0.002) and working memory (WISC working memory: p = 0.002 and K-ABC Word Order (p = 0.010) and Hand Movements (p = 0.001) subtests. Also, the children without seizures scored significantly lower than those with seizures on the WISC Working Memory Index (p = 0.010) and on the K-ABC Word Order (p = 0.021) and Hand Movements (p = 0.027) subtests. Further analysis of our data demonstrated the particular importance of the family context for child development. Significant cognitive deficits were found only in children with RD from parents with lower educational levels. This group consistently scored lower compared to the control group regarding IQ (full scale IQ: p < 0.001; verbal IQ: p < 0.001; performance IQ: p = 0.012; processing speed: p = 0.034), visual perception (general visual perception: p = 0.018; visual-motor integration: p = 0.010) and auditory working memory (WISC working memory: p = 0.014). Furthermore, compared to the children with RE, they performed significantly weaker on verbal IQ (p = 0.020), auditory working memory consistently (WISC working memory: p = 0.027; K-ABC: Word Order: p = 0.046) as well as in one of the K-ABC spatial working memory subtests (Hand Movements: p = 0.029). Although we did not find significant deficits in children with new-onset RE compared to healthy controls, the performance of this group tended to be weaker more often. No statistically significant associations were observed between selected clinical markers (focus types: centrotemporal/other foci/laterality of foci and spread of Rolandic discharges) and cognitive test results. Except for spatial working memory, we also found no evidence that the age of our patients at the time of study participation was of significant importance to their cognitive performance. CONCLUSIONS: Our study provides some evidence that children with Rolandic discharges, with and without seizures, may be at higher risk of cognitive impairment. In addition to medical care, we emphasise early differentiated psychosocial diagnostics to provide these children and their families with targeted support if developmental problems are present.


Assuntos
Epilepsia Rolândica , Memória de Curto Prazo , Criança , Pré-Escolar , Humanos , Cognição , Eletroencefalografia , Epilepsia Rolândica/complicações , Epilepsia Rolândica/psicologia , Inteligência , Testes Neuropsicológicos , Convulsões , Percepção Visual
3.
United European Gastroenterol J ; 12(1): 56-65, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38213079

RESUMO

BACKGROUND: Adequate bowel preparation is a prerequisite for colonoscopy. However, up to 20% of colonoscopies remain inadequately prepared. Risk factors for inadequate bowel preparation often overlap with those of failed cecal intubation. This study aimed to assess the feasibility of an intraprocedural bowel cleansing system (BCS) in patients with a history of inadequate bowel preparation. METHODS: Patients (n = 44) with a history of inadequate bowel preparation in the past 2 years were included. After a limited preparation with 300 mL split-dose sodium picosulfate magnesium citrate, additional cleansing during colonoscopy was performed with the BCS. The primary outcome was adequate bowel preparation using the Boston Bowel Preparation Scale (BBPS). Secondary outcomes included cecal intubation rate, procedure times, usability, and safety. RESULTS: Median BBPS increased from 1-2-2 (IQR 1-2) to 3-3-3 (IQR) (p < 0.0001), with 31.8% and 88.6% of patients adequately prepared before and after using the BCS, respectively (p < 0.0001). Cecal intubation rate was 88.6%. Reasons for incomplete colonoscopy were looping (n = 2), technical failure (n = 1), relative stricture (n = 1), and residual feces (n = 1). In patients with complete colonoscopy, the adequate cleansing rate was 97.5%. Median total procedure time was 26 min, of which 5.3 min were spent on cleaning. General ease of use was scored with a median of 4 out of 5, representing "as good as conventional colonoscopy". No serious adverse events occurred. CONCLUSIONS: Adequate bowel cleaning can be achieved with an intraprocedural BCS in patients with a history of inadequate bowel preparation, which may reduce repeat colonoscopies and clinical admissions for bowel preparation. However, since these patients more frequently have complicated anatomy (surgical scarring, diverticulosis, etc.), adequate patient selection is advised to avoid incomplete procedures.


Assuntos
Catárticos , Colonoscopia , Humanos , Colonoscopia/métodos , Catárticos/efeitos adversos , Estudos de Viabilidade , Ceco , Estudos Prospectivos
4.
Gastrointest Endosc ; 2023 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-37993062

RESUMO

BACKGROUND AND AIMS: Endocuff VisionTM has been designed to enhance mucosal visualization thereby improving detection of (pre-)malignant colorectal lesions. This multicenter, international, back-to-back, randomized colonoscopy trial compared adenoma detection rate (ADR) and adenoma miss rate (AMR) between Endocuff Vision-assisted colonoscopy (EVC) and conventional colonoscopy (CC). METHODS: Patients aged 40-75 years referred for non-immunochemical fecal occult blood test-based screening, surveillance, or diagnostic colonoscopy were included at ten hospitals and randomized into four groups: Group 1; 2xCC, Group 2; CC followed by EVC, Group 3; EVC followed CC and Group 4; 2xEVC. Primary outcomes included ADR and AMR. RESULTS: A total of 717 patients were randomized of which 661 patients (92.2%) had one and 646 (90.1%) patients had two completed back-to-back colonoscopies. EVC did not significantly improve ADR compared to CC (41.1% [95%-CI;36.1-46.3] versus 35.5% [95%-CI;30.7-40.6], respectively, P=0.125), but EVC did reduced AMR by 11.7% (29.6% [95%-CI;23.6-36.5] versus 17.9% [95%-CI;12.5-23.5], respectively, P=0.049). AMR of 2xCC compared to 2xEVC was also not significantly different (25.9% [95%-CI;19.3-33.9] versus 18.8% [95%-CI;13.9-24.8], respectively, P=0.172). Only 3.7% of the polyps missed during the first procedures had advanced pathologic features. Factors affecting risk of missing adenomas were age (P=0.002), Boston Bowel Preparation Scale (P=0.008) and region where colonoscopy was performed (P<0.001). CONCLUSIONS: Our trial shows that EVC reduces the risk of missing adenomas but does not lead to a significant improved ADR. Remarkably, 25% of adenomas are still missed during conventional colonoscopies, which is not different from miss rates reported 25 years ago; reassuringly, advanced features were only found in 3.7% of these missed lesions. TRAIL REGISTRATION NUMBER: NCT03418948.

5.
Dig Dis Sci ; 68(10): 3943-3952, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37558800

RESUMO

INTRODUCTION: In light-emitting diode (LED) and LASER colonoscopy, linked color imaging (LCI) and blue light/laser imaging (BLI) are used for lesion detection and characterization worldwide. We analyzed the difference of LCI and BLI images of colorectal lesions between LED and LASER in a multinational study. METHODS: We prospectively observed lesions with white light imaging (WLI), LCI, and BLI using both LED and LASER colonoscopies from January 2020 to August 2021. Images were graded by 27 endoscopists from nine countries using the polyp visibility score: 4 (excellent), 3 (good), 2 (fair), and 1 (poor) and the comparison score (LED better/similar/LASER better) for WLI/LCI/BLI images of each lesion. RESULTS: Finally, 32 lesions (polyp size: 20.0 ± 15.2 mm) including 9 serrated lesions, 13 adenomas, and 10 T1 cancers were evaluated. The polyp visibility scores of LCI/WLI for international and Japan-expert endoscopists were 3.17 ± 0.73/3.17 ± 0.79 (p = 0.92) and 3.34 ± 0.78/2.84 ± 1.22 (p < 0.01) for LED and 3.30 ± 0.71/3.12 ± 0.77 (p < 0.01) and 3.31 ± 0.82/2.78 ± 1.23 (p < 0.01) for LASER. Regarding the comparison of lesion visibility about between LED and LASER colonoscopy in international endoscopists, a significant difference was achieved not for WLI, but for LCI. The rates of LED better/similar/LASER better for brightness under WLI were 54.5%/31.6%/13.9% (International) and 75.0%/21.9%/3.1% (Japan expert). Those under LCI were 39.2%/35.4%/25.3% (International) and 31.3%/53.1%/15.6% (Japan expert). There were no significant differences in the diagnostic accuracy and the comparison score of BLI images between LED and LASER. CONCLUSIONS: The differences of lesion visibility for WLI/LCI/BLI between LED and LASER in international endoscopists could be compared to those in Japanese endoscopists.


Assuntos
Adenoma , Pólipos do Colo , Neoplasias Colorretais , Humanos , Colonoscopia/métodos , Neoplasias Colorretais/diagnóstico por imagem , Neoplasias Colorretais/patologia , Pólipos do Colo/diagnóstico por imagem , Pólipos do Colo/patologia , Adenoma/diagnóstico por imagem , Adenoma/patologia , Lasers , Cor
6.
Endoscopy ; 55(1): 58-95, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36423618

RESUMO

MR1: ESGE recommends small-bowel capsule endoscopy as the first-line examination, before consideration of other endoscopic and radiological diagnostic tests for suspected small-bowel bleeding, given the excellent safety profile of capsule endoscopy, its patient tolerability, and its potential to visualize the entire small-bowel mucosa.Strong recommendation, moderate quality evidence. MR2: ESGE recommends small-bowel capsule endoscopy in patients with overt suspected small-bowel bleeding as soon as possible after the bleeding episode, ideally within 48 hours, to maximize the diagnostic and subsequent therapeutic yield.Strong recommendation, high quality evidence. MR3: ESGE does not recommend routine second-look endoscopy prior to small-bowel capsule endoscopy in patients with suspected small-bowel bleeding or iron-deficiency anemia.Strong recommendation, low quality evidence. MR4: ESGE recommends conservative management in those patients with suspected small-bowel bleeding and high quality negative small-bowel capsule endoscopy.Strong recommendation, moderate quality evidence. MR5: ESGE recommends device-assisted enteroscopy to confirm and possibly treat lesions identified by small-bowel capsule endoscopy.Strong recommendation, high quality evidence. MR6: ESGE recommends the performance of small-bowel capsule endoscopy as a first-line examination in patients with iron-deficiency anemia when small bowel evaluation is indicated.Strong recommendation, high quality evidence. MR7: ESGE recommends small-bowel capsule endoscopy in patients with suspected Crohn's disease and negative ileocolonoscopy findings as the initial diagnostic modality for investigating the small bowel, in the absence of obstructive symptoms or known bowel stenosis.Strong recommendation, high quality evidence. MR8: ESGE recommends, in patients with unremarkable or nondiagnostic findings from dedicated small-bowel cross-sectional imaging, small-bowel capsule endoscopy as a subsequent investigation if deemed likely to influence patient management.Strong recommendation, low quality evidence. MR9: ESGE recommends, in patients with established Crohn's disease, the use of a patency capsule before small-bowel capsule endoscopy to decrease the capsule retention rate.Strong recommendation, moderate quality evidence. MR10: ESGE recommends device-assisted enteroscopy (DAE) as an alternative to surgery for foreign bodies retained in the small bowel requiring retrieval in patients without acute intestinal obstruction.Strong recommendation, moderate quality evidence. MR11: ESGE recommends DAE-endoscopic retrograde cholangiopancreatography (DAE-ERCP) as a first-line endoscopic approach to treat pancreaticobiliary diseases in patients with surgically altered anatomy (except for Billroth II patients).Strong recommendation, moderate quality evidence.


Assuntos
Anemia Ferropriva , Endoscopia por Cápsula , Doença de Crohn , Enteropatias , Humanos , Anemia Ferropriva/diagnóstico , Anemia Ferropriva/etiologia , Anemia Ferropriva/terapia , Endoscopia Gastrointestinal/métodos , Hemorragia Gastrointestinal/diagnóstico , Hemorragia Gastrointestinal/etiologia , Hemorragia Gastrointestinal/terapia , Enteropatias/diagnóstico , Enteropatias/terapia
7.
Leuk Lymphoma ; 64(2): 433-439, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36335433

RESUMO

Graft-versus-host disease (GvHD) involving the intestine is a threat to patients after allogeneic hematopoietic stem cell transplantation (alloHSCT). We evaluated biopsies from different sites of the upper gastrointestinal tract (GIT) of 97 patients after alloHSCT. Forty-six patients with clinical symptoms consistent with upper GI GvHD revealed histological features of GvHD in the esophagus, stomach, and/or duodenum. Biopsies of the duodenum and esophagus were significantly more sensitive for signs of GvHD than those of the gastric antrum or corpus. The histological features of GvHD were significantly correlated with the endoscopic findings of ulcers, erosion, atrophy, and white plaques; however, the sensitivity and specificity of the latter were low. In univariate analysis, overall mortality was significantly associated with histological GvHD signs in all four sites. Nonrelapse mortality was associated with histologic GvHD features in the antrum only. Regarding GvHD diagnosis, biopsies of the upper gastrointestinal tract should include the duodenum and/or esophagus.


Assuntos
Doença Enxerto-Hospedeiro , Transplante de Células-Tronco Hematopoéticas , Trato Gastrointestinal Superior , Humanos , Trato Gastrointestinal Superior/patologia , Biópsia , Esôfago/patologia , Duodeno/patologia , Transplante de Células-Tronco Hematopoéticas/efeitos adversos , Doença Enxerto-Hospedeiro/diagnóstico , Doença Enxerto-Hospedeiro/etiologia , Trato Gastrointestinal/patologia
8.
Endoscopy ; 54(9): 904-915, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35913069

RESUMO

The European Society of Gastrointestinal Endoscopy (ESGE) presents a short list of performance measures for colonoscopy in inflammatory bowel disease (IBD) patients. Current performance measures for colonoscopy mainly focus on detecting (pre)malignant lesions. However, these performance measures are not relevant for all colonoscopy indications in IBD patients. Therefore, our aim was to provide endoscopy services across Europe and other interested countries with a tool for quality monitoring and improvement in IBD colonoscopy. Eight key performance measures and one minor performance measure were recommended for measurement and evaluation in daily endoscopy practice.


Assuntos
Doenças Inflamatórias Intestinais , Melhoria de Qualidade , Colonoscopia , Endoscopia Gastrointestinal , Europa (Continente) , Humanos , Doenças Inflamatórias Intestinais/diagnóstico por imagem
9.
Surg Endosc ; 36(5): 2954-2961, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34129089

RESUMO

BACKGROUND: A recently developed haemostatic peptide gel for endoscopic application has been introduced to improve the management of gastrointestinal bleeding. The aim of this pilot study was to evaluate the feasibility, safety, efficacy and indication profiles of PuraStat in a clinical setting. METHODS: In this prospective observational multicentre pilot study, patients with acute non-variceal gastrointestinal bleeding (upper and lower) were included. Primary and secondary application of PuraStat was evaluated. Haemoglobin, prothrombin time, platelets and transfusion behaviour were documented before and after haemostasis. The efficacy of PuraStat was assessed during the procedure, at 3 days and 1 week after application. RESULTS: 111 patients with acute gastrointestinal bleeding were recruited into the study. 70 percent (78/111) of the patients had upper gastrointestinal bleeding and 30% (33/111) had lower gastrointestinal bleeding. After primary application of PuraStat, initial haemostatic success was achieved in 94% of patients (74/79, 95% CI 88-99%), and in 75% of the patients when used as a secondary haemostatic product, following failure of established techniques (24/32, 95% CI 59-91%). The therapeutic success rates (absence of rebleeding) after 3 and 7 days were 91% and 87% after primary use, and 87% and 81% in all study patients. Overall rebleeding rate at 30 day follow-up was 16% (18/111). In the 5 patients who finally required surgery (4.5%), PuraStat allowed temporary haemostasis and stabilisation. CONCLUSIONS: PuraStat expanded the therapeutic toolbox available for an effective treatment of gastrointestinal bleeding sources. It could be safely applied and administered without complications as a primary or secondary therapy. PuraStat may additionally serve as a bridge to surgery in order to achieve temporary haemostasis in case of refractory severe bleeding, possibly playing a role in preventing immediate emergency surgery.


Assuntos
Hemostase Endoscópica , Hemostáticos , Hemorragia Gastrointestinal/etiologia , Hemorragia Gastrointestinal/cirurgia , Hemostase Endoscópica/métodos , Hemostáticos/uso terapêutico , Humanos , Projetos Piloto , Estudos Prospectivos , Resultado do Tratamento
11.
Endoscopy ; 54(2): 180-184, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-33494106

RESUMO

BACKGROUND: Use of artificial intelligence may increase detection of colorectal neoplasia at colonoscopy by improving lesion recognition (CADe) and reduce pathology costs by improving optical diagnosis (CADx). METHODS: A multicenter library of ≥ 200 000 images from 1572 polyps was used to train a combined CADe/CADx system. System testing was performed on two independent image sets (CADe: 446 with polyps, 234 without; CADx: 267) from 234 polyps, which were also evaluated by six endoscopists (three experts, three non-experts). RESULTS: CADe showed sensitivity, specificity, and accuracy of 92.9 %, 90.6 %, and 91.7 %, respectively. Experts showed significantly higher accuracy and specificity, and similar sensitivity, while non-experts + CADe showed comparable sensitivity but lower specificity and accuracy than CADe and experts. CADx showed sensitivity, specificity, and accuracy of 85.0 %, 79.4 %, and 83.6 %, respectively. Experts showed comparable performance, whereas non-experts + CADx showed comparable accuracy but lower specificity than CADx and experts. CONCLUSIONS: The high accuracy shown by CADe and CADx was similar to that of experts, supporting further evaluation in a clinical setting. When using CAD, non-experts achieved a similar performance to experts, with suboptimal specificity.


Assuntos
Adenoma , Pólipos do Colo , Neoplasias Colorretais , Juniperus , Adenoma/patologia , Inteligência Artificial , Pólipos do Colo/diagnóstico por imagem , Pólipos do Colo/patologia , Colonoscopia/métodos , Neoplasias Colorretais/diagnóstico por imagem , Neoplasias Colorretais/patologia , Computadores , Diagnóstico por Computador , Humanos
12.
Endoscopy ; 54(1): 88-99, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34872120

RESUMO

BACKGROUND : The European Society of Gastrointestinal Endoscopy (ESGE) has developed a core curriculum for high quality optical diagnosis training for practice across Europe. The development of easy-to-measure competence standards for optical diagnosis can optimize clinical decision-making in endoscopy. This manuscript represents an official Position Statement of the ESGE aiming to define simple, safe, and easy-to-measure competence standards for endoscopists and artificial intelligence systems performing optical diagnosis of diminutive colorectal polyps (1 - 5 mm). METHODS : A panel of European experts in optical diagnosis participated in a modified Delphi process to reach consensus on Simple Optical Diagnosis Accuracy (SODA) competence standards for implementation of the optical diagnosis strategy for diminutive colorectal polyps. In order to assess the clinical benefits and harms of implementing optical diagnosis with different competence standards, a systematic literature search was performed. This was complemented with the results from a recently performed simulation study that provides guidance for setting alternative competence standards for optical diagnosis. Proposed competence standards were based on literature search and simulation study results. Competence standards were accepted if at least 80 % agreement was reached after a maximum of three voting rounds. RECOMMENDATION 1: In order to implement the leave-in-situ strategy for diminutive colorectal lesions (1-5 mm), it is clinically acceptable if, during real-time colonoscopy, at least 90 % sensitivity and 80 % specificity is achieved for high confidence endoscopic characterization of colorectal neoplasia of 1-5 mm in the rectosigmoid. Histopathology is used as the gold standard.Level of agreement 95 %. RECOMMENDATION 2: In order to implement the resect-and-discard strategy for diminutive colorectal lesions (1-5 mm), it is clinically acceptable if, during real-time colonoscopy, at least 80 % sensitivity and 80 % specificity is achieved for high confidence endoscopic characterization of colorectal neoplasia of 1-5 mm. Histopathology is used as the gold standard.Level of agreement 100 %. CONCLUSION : The developed SODA competence standards define diagnostic performance thresholds in relation to clinical consequences, for training and for use when auditing the optical diagnosis of diminutive colorectal polyps.


Assuntos
Pólipos do Colo , Neoplasias Colorretais , Inteligência Artificial , Pólipos do Colo/diagnóstico por imagem , Colonoscopia , Neoplasias Colorretais/diagnóstico por imagem , Endoscopia Gastrointestinal , Humanos
14.
Aliment Pharmacol Ther ; 54(9): 1179-1192, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34472640

RESUMO

BACKGROUND: Irritable bowel syndrome (IBS) patients often experience meal-associated symptoms. However, the underlying mechanisms are unclear. AIM: To determine small intestinal mechanisms of lipid-induced symptoms and rectal hypersensitivity in IBS METHODS: We recruited 26 IBS patients (12 IBS-C, 14 IBS-D) and 15 healthy volunteers (HV). In vivo permeability was assessed using saccharide excretion assay. Rectal sensitivity was assessed using a barostat before and after small bowel lipid infusion; symptoms were assessed throughout. Next, an extended upper endoscopy with probe-based confocal laser endomicroscopy (pCLE) was performed with changes induced by lipids. Duodenal and jejunal mucosal biopsies were obtained for transcriptomics. RESULTS: Following lipid infusion, a higher proportion of HV than IBS patients reported no pain, no nausea, no fullness and no urgency (P < 0.05 for all). In a model adjusted for sex and anxiety, IBS-C and IBS-D patients had lower thresholds for first rectal sensation (P = 0.0007) and pain (P = 0.004) than HV. In vivo small intestinal permeability and mean pCLE scores were similar between IBS patients and HV. Post-lipid, pCLE scores were higher than pre-lipid but were not different between groups. Baseline duodenal transient receptor potential vanilloid (TRPV) 1 and 3 expression was increased in IBS-D, and TRPV3 in IBS-C. Duodenal TRPV1 expression correlated with abdominal pain (r = 0.51, FDR = 0.01), and inversely with first rectal sensation (r = -0.48, FDR = 0.01) and pain (r = -0.41, FDR = 0.02) thresholds. CONCLUSION: Lipid infusion elicits a greater symptom response in IBS patients than HV, which is associated with small intestinal expression of TRPV channels. TRPV-mediated small intestinal chemosensitivity may mediate post-meal symptoms in IBS.


Assuntos
Síndrome do Intestino Irritável , Canais de Potencial de Receptor Transitório , Dor Abdominal , Humanos , Intestino Delgado , Síndrome do Intestino Irritável/tratamento farmacológico , Reto
15.
PLoS One ; 16(8): e0255955, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34437563

RESUMO

BACKGROUND: Linked color imaging (LCI) has been shown to be effective in multiple randomized controlled trials for enhanced colorectal polyp detection. Recently, artificial intelligence (AI) with deep learning through convolutional neural networks has dramatically improved and is increasingly recognized as a promising new technique for enhancing colorectal polyp detection. AIM: This study aims to evaluate a newly developed computer-aided detection (CAD) system in combination with LCI for colorectal polyp detection. METHODS: First, a convolutional neural network was trained for colorectal polyp detection in combination with the LCI technique using a dataset of anonymized endoscopy videos. For validation, 240 polyps within fully recorded endoscopy videos in LCI mode, covering the entire spectrum of adenomatous histology, were used. Sensitivity (true-positive rate per lesion) and false-positive frames in a full procedure were assessed. RESULTS: The new CAD system used in LCI mode could process at least 60 frames per second, allowing for real-time video analysis. Sensitivity (true-positive rate per lesion) was 100%, with no lesion being missed. The calculated false-positive frame rate was 0.001%. Among the 240 polyps, 34 were sessile serrated lesions. The detection rate for sessile serrated lesions with the CAD system used in LCI mode was 100%. CONCLUSIONS: The new CAD system used in LCI mode achieved a 100% sensitivity per lesion and a negligible false-positive frame rate. Note that the new CAD system used in LCI mode also specifically allowed for detection of serrated lesions in all cases. Accordingly, the AI algorithm introduced here for the first time has the potential to dramatically improve the quality of colonoscopy.


Assuntos
Algoritmos , Pólipos do Colo/diagnóstico , Colonoscopia/métodos , Cor , Diagnóstico por Computador/métodos , Redes Neurais de Computação , Humanos
16.
PLoS One ; 16(8): e0256543, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34437603

RESUMO

Acute graft versus host disease (aGvHD) is an important, life-threatening complication after allogeneic hematopoietic stem cell transplantation (alloHSCT). To investigate the value of multiple simultaneous colon biopsies in improving diagnostic accuracy in patients with aGvHD, we retrospectively analyzed 157 patients after alloHSCT. The biopsies were evaluated individually using three established histological grading systems (Lerner, Sale, and Melson). The maximum, minimum, median, and mean histological aGvHD grades were calculated for each patient, and the results were correlated with the Glucksberg grade of clinical manifestation of GvHD, steroid therapy status, and outcome. We found that multiple colon biopsies enhanced diagnostic sensitivity. Moreover, higher histological grades correlated with steroid therapy initiation and refractoriness; the latter particularly occurred when advanced damage was present in all samples and healthy colon mucosa was reduced or absent. On multivariate analysis, the minimal Lerner and Glucksberg grades for intestinal aGvHD were significantly associated with steroid treatment failure. Ninety-nine patients died. The median survival was 285 days after the biopsies were taken. Fifteen patients died from relapse of their underling disorder and 84 from other causes, mostly infection (53 patients) and GvHD (14 patients). Multivariate analysis revealed a significant association between none-relapse mortality and the mean Lerner grade, minimum Melson grade, Glucksberg organ stage, and platelet counts. Thus, we found the Lerner system to be superior to the other grading methods in most instances and histologic evaluation of multiple simultaneously obtained biopsies from the colon to result in a higher diagnostic yield, which helps plan systemic steroid treatment while predicting treatment response and outcome.


Assuntos
Colo/patologia , Doença Enxerto-Hospedeiro/diagnóstico , Doença Enxerto-Hospedeiro/patologia , Doença Aguda , Adolescente , Adulto , Idoso , Biópsia , Endoscopia , Feminino , Doença Enxerto-Hospedeiro/diagnóstico por imagem , Doença Enxerto-Hospedeiro/tratamento farmacológico , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Prognóstico , Modelos de Riscos Proporcionais , Esteroides/farmacologia , Esteroides/uso terapêutico , Resultado do Tratamento , Adulto Jovem
17.
Gastrointest Endosc ; 94(6): 1071-1081, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34228981

RESUMO

BACKGROUND AND AIMS: There are no agreed-on endoscopic signs for the diagnosis of villous atrophy (VA) in celiac disease (CD), necessitating biopsy sampling for diagnosis. Here we evaluated the role of near-focus narrow-band imaging (NF-NBI) for the assessment of villous architecture in suspected CD with the development and further validation of a novel NF-NBI classification. METHODS: Patients with a clinical indication for duodenal biopsy sampling were prospectively recruited. Six paired NF white-light endoscopy (NF-WLE) and NF-NBI images with matched duodenal biopsy sampling including the bulb were obtained from each patient. Histopathology grading used the Marsh-Oberhuber classification. A modified Delphi process was performed on 498 images and video recordings by 3 endoscopists to define NF-NBI classifiers, resulting in a 3-descriptor classification: villous shape, vascularity, and crypt phenotype. Thirteen blinded endoscopists (5 expert, 8 nonexpert) then undertook a short training module on the proposed classification and evaluated paired NF-WLE-NF-NBI images. RESULTS: One hundred consecutive patients were enrolled (97 completed the study; 66 women; mean age, 51.2 ± 17.3 years). Thirteen endoscopists evaluated 50 paired NF-WLE and NF-NBI images each (24 biopsy-proven VAs). Interobserver agreement among all validators for the diagnosis of villous morphology using the NF-NBI classification was substantial (κ = .71) and moderate (κ = .46) with NF-WLE. Substantial agreement was observed between all 3 NF-NBI classification descriptors and histology (weighted κ = 0.72-.75) compared with NF-WLE to histology (κ = .34). A higher degree of confidence using NF-NBI was observed when assessing the duodenal bulb. CONCLUSIONS: We developed and validated a novel NF-NBI classification to reliably diagnose VA in suspected CD. There was utility for expert and nonexpert endoscopists alike, using readily available equipment and requiring minimal training. (Clinical trial registration number: NCT04349904.).


Assuntos
Doença Celíaca , Adulto , Idoso , Atrofia/patologia , Doença Celíaca/diagnóstico por imagem , Duodeno/diagnóstico por imagem , Duodeno/patologia , Endoscopia , Feminino , Humanos , Pessoa de Meia-Idade , Imagem de Banda Estreita
18.
Therap Adv Gastroenterol ; 14: 17562848211017730, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34178115

RESUMO

INTRODUCTION: Since the advent of artificial intelligence (AI) in clinical studies, luminal gastrointestinal endoscopy has made great progress, especially in the detection and characterization of neoplastic and preneoplastic lesions. Several studies have recently shown the potential of AI-driven endoscopy for the investigation of inflammatory bowel disease (IBD). This systematic review provides an overview of the current position and future potential of AI in IBD endoscopy. METHODS: A systematic search was carried out in PubMed and Scopus up to 2 December 2020 using the following search terms: artificial intelligence, machine learning, computer-aided, inflammatory bowel disease, ulcerative colitis (UC), Crohn's disease (CD). All studies on human digestive endoscopy were included. A qualitative analysis and a narrative description were performed for each selected record according to the Joanna Briggs Institute methodologies and the PRISMA statement. RESULTS: Of 398 identified records, 18 were ultimately included. Two-thirds of these (12/18) were published in 2020 and most were cross-sectional studies (15/18). No relevant bias at the study level was reported, although the risk of publication bias across studies cannot be ruled out at this early stage. Eleven records dealt with UC, five with CD and two with both. Most of the AI systems involved convolutional neural network, random forest and deep neural network architecture. Most studies focused on capsule endoscopy readings in CD (n = 5) and on the AI-assisted assessment of mucosal activity in UC (n = 10) for automated endoscopic scoring or real-time prediction of histological disease. DISCUSSION: AI-assisted endoscopy in IBD is a rapidly evolving research field with promising technical results and additional benefits when tested in an experimental clinical scenario. External validation studies being conducted in large and prospective cohorts in real-life clinical scenarios will help confirm the added value of AI in assessing UC mucosal activity and in CD capsule reading. PLAIN LANGUAGE SUMMARY: Artificial intelligence for inflammatory bowel disease endoscopy Artificial intelligence (AI) is a promising technology in many areas of medicine. In recent years, AI-assisted endoscopy has been introduced into several research fields, including inflammatory bowel disease (IBD) endoscopy, with promising applications that have the potential to revolutionize clinical practice and gastrointestinal endoscopy.We have performed the first systematic review of AI and its application in the field of IBD and endoscopy.A formal process of paper selection and analysis resulted in the assessment of 18 records. Most of these (12/18) were published in 2020 and were cross-sectional studies (15/18). No relevant biases were reported. All studies showed positive results concerning the novel technology evaluated, so the risk of publication bias cannot be ruled out at this early stage.Eleven records dealt with UC, five with CD and two with both. Most studies focused on capsule endoscopy reading in CD patients (n = 5) and on AI-assisted assessment of mucosal activity in UC patients (n = 10) for automated endoscopic scoring and real-time prediction of histological disease.We found that AI-assisted endoscopy in IBD is a rapidly growing research field. All studies indicated promising technical results. When tested in an experimental clinical scenario, AI-assisted endoscopy showed it could potentially improve the management of patients with IBD.Confirmatory evidence from real-life clinical scenarios should be obtained to verify the added value of AI-assisted IBD endoscopy in assessing UC mucosal activity and in CD capsule reading.

20.
Therap Adv Gastroenterol ; 14: 17562848211013494, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34104209

RESUMO

BACKGROUND: Although colonoscopy is the gold standard for colorectal cancer screening, colonic looping may make complete colonoscopy challenging. Commonly available stiffening device colonoscopy has been described as helpful but not effective enough to prevent looping. In this context the effect on cecal intubation time and rate was described differently in various studies and in some studies had no impact on cecal intubation time at all. The aim of this study was to evaluate whether a novel colonoscope with gradual stiffness (Fujifilm EC760R-V/I- flexibility adjuster, Tokyo, Japan) using four significantly different grades of stiffness can be an alternative to established devices in terms of loop prevention, cecal intubation rate and time, adverse events, and patient/examiner satisfaction. METHODS: Consecutive patients without previous colorectal surgery were analyzed retrospectively. Colonoscopy was performed with the new colonoscope and performance characteristics, including time to cecum, withdrawal time, total examination time, and patient and endoscopist satisfaction were recorded. RESULTS: Among 180 consecutive procedures, 98.3% of examinations were complete to the cecum. The endoscopic flexibility adjuster was used in 150 of 180 cases (83.3%). Overall, the device was scored by the examiner as helpful to prevent looping in 146 of the 150 cases (97.7%). Mean cecal intubation time was 6.5 min, with 35% of examination performed in under 5 min with a mean withdrawal time of 7 min. Mean total examination time was 18 min. Patient satisfaction was rated as high in all examinations performed. CONCLUSION: The new flexibility adjuster colonoscope was shown to be helpful in loop prevention, allowed for fast and successful cecal intubation, and led to a high rate of patients satisfaction.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...