Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rapid Commun Mass Spectrom ; 22(23): 3873-82, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19003851

RESUMO

Aerosol Time-of-Flight Mass Spectrometry (AToFMS) was used to examine co-association between two inhaled drugs, fluticasone propionate (FP) and salmeterol xinofoate (SX), in fine aerosolised particles emitted from Seretide(R)/Advair(R) inhaled combination products. Principal Component Analysis (PCA) was used to identify fragmentation patterns indicative of either pure or co-associated particles (particles containing both drugs). A third component of the particles emitted from dry powder inhalers (DPIs), lactose, gave only a very weak mass spectral signal and no interpretable data was acquired for this compound; however, it was not found to interfere with the detection of the two drug substances. High levels of co-association were found in the emitted doses from both pressurised metered dose inhaler (pMDI) and dry powder inhaler (DPI) products.


Assuntos
Albuterol/análogos & derivados , Androstadienos/química , Espectrometria de Massas/métodos , Análise de Componente Principal , Administração por Inalação , Aerossóis/química , Albuterol/administração & dosagem , Albuterol/química , Androstadienos/administração & dosagem , Broncodilatadores/administração & dosagem , Broncodilatadores/química , Combinação de Medicamentos , Fluticasona , Combinação Fluticasona-Salmeterol , Humanos , Lactose/análise , Inaladores Dosimetrados , Análise Multivariada , Nebulizadores e Vaporizadores , Tamanho da Partícula , Xinafoato de Salmeterol
2.
Analyst ; 128(9): 1150-6, 2003 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-14529022

RESUMO

A universal temperature controlled membrane interface (TCMI) has been constructed for hollow-fibre membranes. The membrane temperature is controllable in the range -70 to 250 degrees C using an electric heater and a flow of cooled nitrogen or helium gas. Volatile and semi-volatile organic compounds may be detected either by continuous diffusion across the membrane or by in-membrane pre-concentration followed by thermal desorption into the detector. The TCMI interface is demonstrated in combination with mass spectrometry and GC-MS, for the determination of VOCs and SVOCs in aqueous and air samples and for the on-line monitoring of a bioreactor.


Assuntos
Análise de Injeção de Fluxo/instrumentação , Cromatografia Gasosa-Espectrometria de Massas/métodos , Membranas Artificiais , Compostos Orgânicos/análise , Temperatura , Análise de Injeção de Fluxo/métodos
3.
Anal Chem ; 74(1): 300-4, 2002 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-11795811

RESUMO

Reversed-phase membrane inlet mass spectrometry incorporating a hollow-fiber Nafion membrane has been evaluated for the determination of low molecular weight alcohols in chloroform. The hydrophilic Nafion membrane preferentially transports methanol and ethanol, allowing percentage concentrations of the alcohols to be determined in a chloroform matrix. A linear response was observed for ethanol over the working range 0.5-2.5%, with a limit of detection of 0.1%. The application of reversed-phase membrane inlet mass spectrometry using a Nafion membrane to the monitoring of a chloroform recovery process has been investigated using a residual gas analyzer. Evolving methanol and ethanol concentrations were determined in real time and compared favorably with off-line determinations by gas chromatography.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...