Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
ACS Meas Sci Au ; 3(1): 21-31, 2023 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-36817006

RESUMO

For the detection of electrochemically produced hydroxyl radicals (HO·) from the oxidation of water on a boron-doped diamond (BDD) electrode, electron paramagnetic resonance spectroscopy (EPR) in combination with spin trap labels is a popular technique. Here, we show that quantification of the concentration of HO· from water oxidation via spin trap electrochemical (EC)-EPR is problematic. This is primarily due to the spin trap oxidizing at potentials less positive than water, resulting in the same spin trap-OH· adduct as formed from the solution reaction of OH· with the spin trap. We illustrate this through consideration of 5,5-dimethyl-1-pyrroline N-oxide (DMPO) as a spin trap for OH·. DMPO oxidation on a BDD electrode in an acidic aqueous solution occurs at a peak current potential of +1.90 V vs SCE; the current for water oxidation starts to rise rapidly at ca. +2.3 V vs SCE. EC-EPR spectra show signatures due to the spin trap adduct (DMPO-OH·) at potentials lower than that predicted thermodynamically (for water/HO·) and in the region for DMPO oxidation. Increasing the potential into the water oxidation region, surprisingly, shows a lower DMPO-OH· concentration than when the potential is in the DMPO oxidation region. This behavior is attributed to further oxidation of DMPO-OH·, production of fouling products on the electrode surface, and bubble formation. Radical scavengers (ethanol) and other spin traps, here N-tert-butyl-α-phenylnitrone, α-(4-pyridyl N-oxide)-N-tert-butylnitrone, and 2-methyl-2-nitrosopropane dimer, also show electrochemical oxidation signals less positive than that of water on a BDD electrode. Such behavior also complicates their use for the intended application.

2.
J Phys Chem Lett ; 11(16): 6677-6683, 2020 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-32680426

RESUMO

Atomic-scale defects can control the exploitable optoelectronic performance of crystalline materials, and several point defects in diamond are emerging functional components for a range of quantum technologies. Nitrogen and hydrogen are common impurities incorporated into diamond, and there is a family of defects that includes both. The N3VH0 defect is a lattice vacancy where three nearest neighbor carbon atoms are replaced with nitrogen atoms and a hydrogen is bonded to the remaining carbon. It is regularly observed in natural and high-temperature annealed synthetic diamond and gives rise to prominent absorption features in the mid-infrared. Here, we combine time- and spectrally resolved infrared absorption spectroscopy to yield unprecedented insight into the N3VH0 defect's vibrational dynamics following infrared excitation of the C-H stretch. In doing so, we gain fundamental information about the energies of quantized vibrational states and corroborate our results with theory. We map out, for the first time, energy relaxation pathways, which include multiphonon relaxation processes and anharmonic coupling to the C-H bend mode. These advances provide new routes to quantify and probe atomic-scale defects.

3.
Chem Rev ; 120(12): 5745-5794, 2020 06 24.
Artigo em Inglês | MEDLINE | ID: mdl-32048841

RESUMO

Nitrogen is ubiquitous in both natural and laboratory-grown diamond, but the number and nature of the nitrogen-containing defects can have a profound effect on the diamond material and its properties. An ever-growing fraction of the supply of diamond appearing on the world market is now lab-grown. Here, we survey recent progress in two complementary diamond synthesis methods-high pressure high temperature (HPHT) growth and chemical vapor deposition (CVD), how each is allowing ever more precise control of nitrogen incorporation in the resulting diamond, and how the diamond produced by either method can be further processed (e.g., by implantation or annealing) to achieve a particular outcome or property. The burgeoning availability of diamond samples grown under well-defined conditions has also enabled huge advances in the characterization and understanding of nitrogen-containing defects in diamond-alone and in association with vacancies, hydrogen, and transition metal atoms. Among these, the negatively charged nitrogen-vacancy (NV-) defect in diamond is attracting particular current interest in account of the many new and exciting opportunities it offers for, for example, quantum technologies, nanoscale magnetometry, and biosensing.

4.
J Am Chem Soc ; 141(2): 1035-1044, 2019 01 16.
Artigo em Inglês | MEDLINE | ID: mdl-30525559

RESUMO

While quinone proton coupled electron transfer (PCET) under buffered conditions is well understood, the situation is more complicated in unbuffered aqueous solutions. With a view to producing a quinone-based voltammetric pH electrode that can function universally in both buffered and unbuffered solutions by following a two-electron (2e-)/two-proton (2H+) Nernstian pathway over a wide pH range, the voltammetric response of strongly electronically coupled surface-bound quinones, directly integrated into a boron-doped diamond (BDD) electrode, is investigated. A laser ablation process enables integration of quinones into the BDD electrode surface with a high p Ka1 (first protonation state) and with controllable, very low surface coverages (as low as 2 orders of magnitude below monolayer coverage). Under buffered conditions, one wave results for all pH values, and the 2e-/2H+ pathway is followed across the entire pH range. The measured ET rate constant values, from Laviron analysis, are also high, indicative of fast ET pathways. Under unbuffered conditions, one wave is again observed for all pH values; however, deviations from the buffered 2e-/2H+ behavior are seen in the neutral region (pH 6-8). While 2e-/2H+ transfer is maintained at all times, we attribute the observed deviation to local pH changes caused by the consumption and generation of protons at the electrode surface during the redox electrochemistry of the quinone. The associated proton fluxes generated at such sparse surface coverages are thought to be sufficiently high enough to prevent ET from occurring exclusively via a proton-independent route. By reducing surface coverage (down to ∼4 × 10-12 mol cm-2; the limit of our laser ablation process) local pH changes can be reduced but are not eradicated completely. By moving to a pulsed voltammetric technique, where for each potential step protons consumed at the electrode are immediately replaced, it is possible, provided the surface coverage is low enough, to obtain a Nernstian 2e-/2H+ response across a wide pH range in unbuffered solution.

5.
Chem Commun (Camb) ; 54(98): 13845-13848, 2018 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-30468213

RESUMO

l-Tryptophan (Trp), melatonin (MLT) and the Trp-peptide pentagastrin quenched the formation of azidyl radicals generated on irradiation of the anticancer complex trans,trans,trans-[Pt(pyridine)2(N3)2(OH)2] with visible light, giving rise to C3-centred indole radicals which were characterized for Trp and MLT using an EPR spin-trap; indole, together with azidyl and hydroxyl radicals, have potential roles in a multitargeting mechanism of action against resistant cancers.


Assuntos
Antineoplásicos/química , Radicais Livres/química , Compostos Organoplatínicos/química , Fármacos Fotossensibilizantes/química , Piridinas/química , Triptofano/química , Radical Hidroxila/química , Indóis/química , Luz , Melatonina/química , Processos Fotoquímicos
6.
ACS Nano ; 12(7): 7388-7396, 2018 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-29969230

RESUMO

In electrodeposition the key challenge is to obtain better control over nanostructure morphology. Currently, a lack of understanding exists concerning the initial stages of nucleation and growth, which ultimately impact the physicochemical properties of the resulting entities. Using identical location scanning transmission electron microscopy (STEM), with boron-doped diamond (BDD) serving as both an electron-transparent TEM substrate and electrode, we follow this process, from the formation of an individual metal atom through to a crystalline metal nanoparticle, under potential pulsed conditions. In doing so, we reveal the importance of electrochemically driven atom transport, atom cluster formation, cluster progression to a nanoparticle, and the mechanism by which neighboring particles interact during growth. Such information will help formulate improved nucleation and growth models and promote wider uptake of electrodeposited structures in a wide range of societally important applications. This type of measurement is possible in the TEM because the BDD possesses inherent stability, has an extremely high thermal conductivity, is electron beam transparent, is free from contamination, and is robust enough for multiple deposition and imaging cycles. Moreover, the platform can be operated under conditions such that we have confidence that the dynamic atom events we image are truly due to electrochemically driven deposition and no other factors, such as electron-beam-induced movement.

7.
Analyst ; 141(11): 3349-57, 2016 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-27118639

RESUMO

The application of electrochemical X-ray fluorescence (EC-XRF), for the detection of palladium (Pd) contamination in a range of solutions containing electrochemically active compounds, present in excess and relevant to the pharmaceutical and food industries, is reported. In EC-XRF, EC is used to electrochemically pre-concentrate metal on an electrode under forced convection conditions, whilst XRF is employed to spectroscopically quantify the amount of metal deposited, which quantitatively correlates with the original metal concentration in solution. Boron doped diamond is used as the electrode due to its very wide cathodic window and the fact that B and C are non-interfering elements for XRF analysis. The effect of several parameters on the Pd XRF signal intensity are explored including: deposition potential (Edep), deposition time (tdep) and Pd(2+) concentration, [Pd(2+)]. Under high deposition potentials (Edep = -1.5 V), the Pd XRF peak intensity varies linearly with both tdep and [Pd(2+)]. Quantification of [Pd(2+)] is demonstrated in the presence of excess acetaminophen (ACM), l-ascorbic acid, caffeine and riboflavin. We show the same Pd XRF signal intensity (for [Pd(2+)] = 1.1 µM and tdep = 325 s) is observed, i.e. same amount of Pd is deposited on the electrode surface, irrespective of whether these redox active molecules are present or absent. For tdep = 900 s we report a limit of detection for [Pd(2+)] of 3.6 ppb (34 nM). Even lower LODs are possible by increasing tdep or by optimising the X-ray source specifically for Pd. The work presented for Pd detection in the presence of ACM, achieves the required detection sensitivity stipulated by international pharmacopeia guidelines.

8.
J Magn Reson ; 265: 77-82, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26867091

RESUMO

A Dynamic Nuclear Polarisation (DNP) enhanced solid-state Magic Angle Spinning (MAS) NMR spectrometer which uses a 187 GHz (corresponding to (1)H NMR frequency of 284 MHz) Extended Interaction Klystron (EIK) amplifier as the microwave source is briefly described. Its performance is demonstrated for a biomolecule (bacteriorhodopsin), a pharmaceutical, and surface functionalised silica. The EIK is very compact and easily incorporated into an existing spectrometer. The bandwidth of the amplifier is sufficient that it obviates the need for a sweepable magnetic field, once set, for all commonly used radicals. The variable power (CW or pulsed) output from the EIK is transmitted to the DNP-NMR probe using a quasi-optic system with a high power isolator and a corrugated waveguide which feeds the microwaves into the DNP-NMR probe. Curved mirrors inside the probe project the microwaves down the axis of the MAS rotor, giving a very efficient system such that maximum DNP enhancement is achieved with less than 3 W output from the microwave source. The DNP-NMR probe operates with a sample temperature down to 90K whilst spinning at 8 kHz. Significant enhancements, in excess of 100 for bacteriorhodopsin in purple membrane (bR in PM), are shown along with spectra which are enhanced by ≈25 with respect to room temperature, for both the pharmaceutical furosemide and surface functionalised silica. These enhancements allow hitherto prohibitively time consuming experiments to be undertaken. The power at which the DNP enhancement in bR in PM saturates does not change significantly between 90K and 170 K even though the enhancement drops by a factor of ≈11. As the DNP build up time decreases by a factor 3 over this temperature range, the reduction in T1n is presumably a significant contribution to the drop in enhancement.

9.
Anal Chem ; 88(1): 974-80, 2016 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-26638677

RESUMO

The development of a voltammetric boron doped diamond (BDD) pH sensor is described. To obtain pH sensitivity, laser micromachining (ablation) is utilized to introduce controlled regions of sp(2) carbon into a high quality polycrystalline BDD electrode. The resulting sp(2) carbon is activated to produce electrochemically reducible quinone groups using a high temperature acid treatment, followed by anodic polarization. Once activated, no further treatment is required. The quinone groups show a linear (R(2) = 0.999) and Nernstian (59 mV/(pH unit)) pH-dependent reductive current-voltage response over a large analyzable pH range, from pH 2 to pH 12. Using the laser approach, it is possible to optimize sp(2) coverage on the BDD surface, such that a measurable pH response is recorded, while minimizing background currents arising from oxygen reduction reactions on sp(2) carbon in the potential region of interest. This enables the sensor to be used in aerated solutions, boding well for in situ analysis. The voltammetric response of the electrode is not compromised by the presence of excess metal ions such as Pb(2+), Cd(2+), Cu(2+), and Zn(2+). Furthermore, the pH sensor is stable over a 3 month period (the current time period of testing), can be stored in air between measurements, requires no reactivation of the surface between measurements, and can be reproducibly fabricated using the proposed approach. The efficacy of this pH sensor in a real-world sample is demonstrated with pH measurements in U.K. seawater.

10.
Phys Chem Chem Phys ; 17(36): 23438-47, 2015 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-26291423

RESUMO

A miniaturised electrochemical cell design for Electron Paramagnetic Resonance (EPR) studies is reported. The cell incorporates a Loop Gap Resonator (LGR) for EPR investigation of electrochemically generated radicals in aqueous (and other large dielectric loss) samples and achieves accurate potential control for electrochemistry by using micro-wires as working electrodes. The electrochemical behaviour of the cell is analysed with COMSOL finite element models and the EPR sensitivity compared to a commercial TE011 cavity resonator using 4-hydroxy-2,2,6,6-tetramethylpiperidin-1-oxyl (TEMPOL) as a reference. The electrochemical EPR performance is demonstrated using the reduction of methyl viologen as a redox probe in both water and acetonitrile. The data reported herein suggest that sub-micromolar concentrations of radical species can be detected in aqueous samples with accurate potential control, and that subtle solution processes coupled to electron transfer, such as comproportionation reactions, can be studied quantitatively using EPR.

11.
Anal Chem ; 87(9): 4933-40, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25860820

RESUMO

The development and application of a new methodology, in situ electrochemical X-ray fluorescence (EC-XRF), is described that enables direct identification and quantification of heavy metals in solution. A freestanding film of boron-doped diamond serves as both an X-ray window and the electrode material. The electrode is biased at a suitable driving potential to electroplate metals from solution onto the electrode surface. Simultaneously, X-rays that pass through the back side of the electrode interrogate the time-dependent electrodeposition process by virtue of the XRF signals, which are unique to each metal. In this way it is possible to unambiguously identify which metals are in solution and relate the XRF signal intensity to a concentration of metal species in solution. To increase detection sensitivity and reduce detection times, solution is flown over the electrode surface by use of a wall-jet configuration. Initial studies focused on the in situ detection of Pb(2+), where concentration detection limits of 99 nM were established in this proof-of-concept study (although significantly lower values are anticipated with system refinement). This is more than 3 orders of magnitude lower than that achievable by XRF alone in a flowing solution (0.68 mM). In situ EC-XRF measurements were also carried out on a multimetal solution containing Hg(2+), Pb(2+), Cu(2+), Ni(2+), Zn(2+), and Fe(3+) (all at 10 µM concentration). Identification of five of these metals was possible in one simple measurement. In contrast, while anodic stripping voltammetry (ASV) also revealed five peaks, peak identification was not straightforward, requiring further experiments and prior knowledge of the metals in solution. Time-dependent EC-XRF nucleation data for the five metals, recorded simultaneously, demonstrated similar deposition rates. Studies are now underway to lower detection limits and provide a quantitative understanding of EC-XRF responses in real, multimetal solutions. Finally, the production of custom-designed portable in situ EC-XRF instrumentation will make heavy metal analysis at the source a very realistic possibility.


Assuntos
Técnicas Eletroquímicas/métodos , Metais Pesados/análise , Espectrometria por Raios X/métodos , Técnicas Eletroquímicas/instrumentação , Soluções , Espectrometria por Raios X/instrumentação
12.
Chem Commun (Camb) ; 51(1): 164-7, 2015 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-25387408

RESUMO

Scanning electrochemical cell microscopy is utilised as a read-write pipette-based probe to both electrochemically modify the local surface chemistry of boron doped diamond and "read" the resulting modification, at the micron scale. In this specific application, localised electrochemical oxidation results in conversion of the H-terminated surface to -O, electrochemically visualised by monitoring the current change for reduction of Ru(NH3)6(3+). This methodology, in general, provides a platform for read-write analysis of electrodes, opening up new analytical avenues, particularly as the pipette can be viewed as a microfluidic device.

13.
Faraday Discuss ; 172: 421-38, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25427195

RESUMO

Thermoelectrochemical experiments can reveal significant information about electrochemical processes compared to ambient only measurements. Typical thermoelectrochemistry is performed using resistively heated wires or laser heated electrodes, both of which can suffer drawbacks associated with the electrode material employed. Boron doped diamond (BDD) is ideal for thermoelectrochemical investigations due to its extremely high thermal conductivity and diffusivity, extreme resistance to thermal ablation (can withstand laser power densities, Pd, of GW cm(-2) for nanosecond pulses) and excellent electrochemical properties (low background currents and wide potential window). In this paper we describe the use of a pulsed laser technique to heat the rear of a 1 mm diameter conducting BDD disc electrode, which drives electrochemical solution reactions at the front face. Maximum electrode temperatures of 90.0 °C were recorded experimentally and confirmed by finite element modelling (FEM). The effect of laser pulsed heating (maximum 3.8 kW cm(-2); 10 ms on and 90 ms off) on the cyclic voltammetric response of two fast (reversible) outer sphere electron transfer redox mediators (Ru(NH3)6(3+/2+) and IrCl6(2-/3-)) are investigated. In particular, we observe pulsed increases in the current, which increase with increasing Pd. The potential of the peak current is shifted positively for the Ru(NH3)6(3+/2+) couple (in accordance with a positive temperature coefficient, ß, +0.68 mV K(-1)) and negatively for the IrCl6(3-/2-) couple (ß = -0.48 mV K(-1)). Scanning backwards, in contrast to that observed for a macrodisc electrode in ambient solution, a cathodic peak is again observed for Ru(NH3)6(3+/2+) and an anodic peak for IrCl6(3-/2-) couple. We attribute this response to the entropy of the redox reaction and the time-dependant change in mass transport due to the induced thermal gradients at the electrode/electrolyte interface. The observed responses are in qualitative agreement with FEM simulations.

14.
Anal Chem ; 86(21): 10834-40, 2014 Nov 04.
Artigo em Inglês | MEDLINE | ID: mdl-25263331

RESUMO

A novel electrochemical approach to the direct detection of hydrogen sulfide (H2S), in aqueous solutions, covering a wide pH range (acid to alkali), is described. In brief, a dual band electrode device is employed, in a hydrodynamic flow cell, where the upstream electrode is used to controllably generate hydroxide ions (OH(-)), which flood the downstream detector electrode and provide the correct pH environment for complete conversion of H2S to the electrochemically detectable, sulfide (HS(-)) ion. All-diamond, coplanar conducting diamond band electrodes, insulated in diamond, were used due to their exceptional stability and robustness when applying extreme potentials, essential attributes for both local OH(-) generation via the reduction of water, and for in situ cleaning of the electrode, post oxidation of sulfide. Using a galvanostatic approach, it was demonstrated the pH locally could be modified by over five pH units, depending on the initial pH of the mobile phase and the applied current. Electrochemical detection limits of 13.6 ppb sulfide were achieved using flow injection amperometry. This approach which offers local control of the pH of the detector electrode in a solution, which is far from ideal for optimized detection of the analyte of interest, enhances the capabilities of online electrochemical detection systems.


Assuntos
Boro , Diamante , Técnicas Eletroquímicas/métodos , Eletrodos , Sulfeto de Hidrogênio/química , Concentração de Íons de Hidrogênio , Técnicas Eletroquímicas/instrumentação , Limite de Detecção , Microscopia Eletrônica de Varredura , Solubilidade
15.
Anal Chem ; 86(11): 5238-44, 2014 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-24814161

RESUMO

Highly doped, boron doped diamond (BDD) is an electrode material with great potential, but the fabrication of suitable electrodes in a variety of different geometries both at the macro- and microscale, with an insulating material that does not compromise the material properties of the BDD, presents technical challenges. In this Technical Note, a novel solution to this problem is presented, resulting in the fabrication of coplanar macro- and microscale BDD electrodes, insulated by insulating diamond, at the single and multiple, individually addressable level. Using a laser micromachining approach, the required electrode(s) geometry is machined into an insulating diamond substrate, followed by overgrowth of high quality polycrystalline BDD (pBDD) and polishing to reveal approximately nanometer roughness, coplanar all-diamond structures. Electrical contacting is possible using both top and bottom contacts, where the latter are defined using the laser to produce non-diamond-carbon (NDC) in the vicinity of the back side of the BDD. We present the fabrication of individually addressable ring, band, and disk electrodes with minimum, reproducible controlled dimensions of 50 µm (limited only by the laser system employed). The pBDD grown into the insulating diamond recesses is shown to be free from NDC and possesses excellent electrochemical properties, in terms of extended solvent windows, electrochemical reversibility, and capacitance.

16.
Anal Chem ; 86(9): 4566-72, 2014 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-24701959

RESUMO

The development of a novel analytical technique, electrochemical X-ray fluorescence (EC-XRF), is described and applied to the quantitative detection of heavy metals in solution, achieving sub-ppb limits of detection (LOD). In EC-XRF, electrochemical preconcentration of a species of interest onto the target electrode is achieved here by cathodic electrodeposition. Unambiguous elemental identification and quantification of metal concentration is then made using XRF. This simple electrochemical preconcentration step improves the LOD of energy dispersive XRF by over 4 orders of magnitude (for similar sample preparation time scales). Large area free-standing boron doped diamond grown using microwave plasma chemical vapor deposition techniques is found to be ideal as the electrode material for both electrodeposition and XRF due to its wide solvent window, transparency to the XRF beam, and ability to be produced in mechanically robust freestanding thin film form. During electrodeposition it is possible to vary both the deposition potential (Edep) and deposition time (tdep). For the metals Cu(2+) and Pb(2+) the highest detection sensitivities were found for Edep = -1.75 V and tdep (=) 4000 s with LODs of 0.05 and 0.04 ppb achieved, respectively. In mixed Cu(2+)/Pb(2+) solutions, EC-XRF shows that Cu(2+) deposition is unimpeded by Pb(2+), across a broad concentration range, but this is only true for Pb(2+) when both metals are present at low concentrations (10 nM), boding well for trace level measurements. In a dual mixed metal solution, EC-XRF can also be employed to either selectively deposit the metal which has the most positive formal reduction potential, E(0), or exhaustively deplete it from solution, enabling uninhibited detection of the metal with the more negative E(0).


Assuntos
Técnicas Eletroquímicas/métodos , Metais Pesados/análise , Espectrometria por Raios X/métodos , Limite de Detecção
17.
Anal Chem ; 85(15): 7230-40, 2013 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-23790001

RESUMO

In order to produce polycrystalline oxygen-terminated boron-doped diamond (BDD) electrodes suitable for electroanalysis (i.e., widest solvent window, lowest capacitive currents, stable and reproducible current responses, and capable of demonstrating fast electron transfer) for outer sphere redox couples, the following factors must be considered. The material must contain enough boron that the electrode shows metal-like conductivity; electrical measurements demonstrate that this is achieved at [B] > 10(20) B atoms cm(-3). Even though BDD contains a lower density of states than a metal, it is not necessary to use extreme doping levels to achieve fast heterogeneous electron transfer (HET). An average [B] ~ 3 × 10(20) B atoms cm(-3) was found to be optimal; increasing [B] results in higher capacitive values and increases the likelihood of nondiamond carbon (NDC) incorporation. Hydrogen-termination causes a semiconducting BDD electrode to behave metal-like due to the additional surface conductivity hydrogen termination brings. Thus, unless [B] of the material is known, the electrical properties of the electrode may be incorrectly interpreted. Note, this layer (formed on a lapped electrode) is electrochemically unstable, an effect which is exacerbated at increased potentials. It is essential during growth that NDC is minimized as it acts to increase capacitive currents and decrease the solvent window. We found complete removal of NDC after growth using aggressive acid cleans, acid cycling, and diamond polishing impossible. Although hydrogen termination can mask the NDC signature in the solvent window and lower capacitive currents, this is not a practical procedure for improving sensitivity in electroanalysis. Finally, alumina polishing of lapped, NDC free, freestanding, BDD electrodes was found to be an effective way to produce well-defined, stable, and reproducible surfaces, which support fast (reversible) HET for Fe(CN)6(4-) electrolysis, the first time this has been reported at an oxygen-terminated surface.

19.
J Am Chem Soc ; 134(40): 16508-11, 2012 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-22991971

RESUMO

The octahedral Pt(IV) complex trans,trans,trans-[Pt(N(3))(2)(OH)(2)(py)(2)] (1) is potently cytotoxic to cancer cells when irradiated with visible (blue) light. We show that the acute photocytotoxicity can be switched off by low doses (500 µM) of the amino acid l-tryptophan. EPR and NMR spectroscopic experiments using spin traps show that l-Trp quenches the formation of azidyl radicals, probably by acting as an electron donor. l-Trp is well-known as a mediator of electron transfer between distant electron acceptor/donor centers in proteins, and such properties may make the free amino acid clinically useful for controlling the activity of photochemotherapeutic azido Pt(IV) drugs. Since previous work has demonstrated the ability of photoactivated 1 to platinate DNA, this suggests that the high potency of such photoactive platinum complexes is related to their dual attack on cancer cells by radicals and Pt(II) photoproducts.


Assuntos
Antineoplásicos/farmacologia , Compostos Organoplatínicos/farmacologia , Neoplasias Ovarianas/tratamento farmacológico , Fármacos Fotossensibilizantes/farmacologia , Triptofano/metabolismo , Antineoplásicos/química , Linhagem Celular Tumoral , Sobrevivência Celular/efeitos dos fármacos , Feminino , Humanos , Luz , Modelos Moleculares , Compostos Organoplatínicos/química , Neoplasias Ovarianas/metabolismo , Fotoquimioterapia , Fármacos Fotossensibilizantes/química
20.
Angew Chem Int Ed Engl ; 51(28): 7002-6, 2012 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-22696181

RESUMO

Conducting carbon materials: a multi-microscopy approach shows that local heterogeneous electron-transfer rates at conducting diamond electrodes correlate with the local density of electronic states. This model of electroactivity is of considerable value for the rational design of conducting diamond electrochemical technologies, and also provides key general insights on electrode structure controls in electrochemical kinetics.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...