Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Chemphyschem ; 15(17): 3776-81, 2014 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-25212729

RESUMO

The crystal structure of pentamethylbenzene has been obtained for the first time with the use of synchrotron radiation, whilst the low-energy spectrum of lattice dynamics, dominated by the methyl group torsions, was obtained using inelastic neutron scattering. The effect of symmetry lowering by the removal of a single methyl group relative to hexamethylbenzene has been investigated, including the role that this plays in the charge-transfer characteristics of complexes formed with tetracyanoethylene.

2.
J Chromatogr A ; 1218(32): 5512-9, 2011 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-21741652

RESUMO

Several procedures are available for simulating and optimising separations in ion chromatography (IC), based on the application of retention models to an extensive database of analyte retention times on a wide range of columns. These procedures are subject to errors arising from batch-to-batch variability in the synthesis of stationary phases, or when using a column having a different diameter to that used when the database was acquired originally. Approaches are described in which the retention database can be recalibrated to accommodate changes in the stationary phase (ion-exchange selectivity coefficient and ion-exchange capacity) or in the column diameter which lead to changes in phase ratio. The entire database can be recalibrated for all analytes on a particular column by performing three isocratic separations with two analyte ions. The retention data so obtained are then used to derive a "porting" equation which is employed to generate the required simulated separation. Accurate prediction of retention times is demonstrated for both anions and cations on 2mm and 0.4mm diameter columns under elution conditions which consist of up to five sequential isocratic or linear gradient elution steps. The proposed approach gives average errors in retention time prediction of less than 3% and the correlation coefficient was 0.9849 between predicted and observed retention times for 344 data points comprising 33 anionic or cationic analytes, 5 column internal diameters and 8 complex elution profiles.


Assuntos
Cromatografia por Troca Iônica/métodos , Ânions/análise , Cátions/análise , Cromatografia por Troca Iônica/instrumentação
3.
Anal Chem ; 80(7): 2474-82, 2008 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-18327920

RESUMO

This study addresses the simulation of ion chromatographic (IC) separations performed under conditions where the elution profile consists of a sequence of isocratic and gradient elution steps (referred to as "complex elution profiles"). First, models for prediction of retention under gradient elution conditions in IC were evaluated using an extensive database of gradient elution retention data. It is shown that one such model is preferred on the basis that it can be used to predict gradient retention times on the basis of isocratic input data. A method is then proposed for using this model for complex elution profiles whereby each step of the elution profile is treated separately and analyte movement through the column is mapped. An empirically based algorithm for predicting peak width under complex elution conditions is also proposed. Evaluation of the suggested approaches was undertaken on a set of 24 analyte anions and 13 analyte cations on 5 different Dionex columns using a range of 5-step complex elution profiles that gave R2 values for correlations between predicted and observed retention times of 0.987 for anions and 0.997 for cations. The simulation of separations of anions and cations using a 3-step complex elution profile is demonstrated, with good correlation between observed and predicted chromatograms. The proposed approach is useful for the rapid development of separations when complex elution profiles are used in IC.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA