Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Cardiovasc Electrophysiol ; 32(6): 1687-1694, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33825257

RESUMO

INTRODUCTION: Cardiac resynchronization defibrillator (CRT-D) as primary prevention is known to reduce mortality. At the time of replacement, higher age and comorbidities may attenuate the benefit of implantable cardioverter-defibrillator (ICD) therapy. The purpose of this study was to evaluate the progression of comorbidities after implantation and their association with mortality following CRT-D generator replacement. In addition, a risk score was developed to identify patients at high risk for mortality after replacement. METHODS AND RESULTS: We identified patients implanted with a primary prevention CRT-D (n = 648) who subsequently underwent elective generator replacement (n = 218) from two prospective ICD registries. The cohort consisted of 218 patients (median age: 70 years, male gender: 73%, mean left ventricular ejection fraction [LVEF]: 36 ± 11% at replacement). Median follow-up after the replacement was 4.2 years during which 64 patients (29%) died and 11 patients (5%) received appropriate ICD shocks. An increase in comorbidities was observed in 77 patients (35%). The 5-year mortality rate was 41% in patients with ≥2 comorbidities at the time of replacement. A risk score incorporating age, gender, LVEF, atrial fibrillation, anemia, chronic kidney disease, and history of appropriate ICD shocks at time of replacement accurately predicted 5-year mortality (C-statistic 0.829). Patients with a risk score of greater than 2.5 had excess mortality at 5-year postreplacement compared with patients with a risk score less than 1.5 (57% vs. 6%; p < .001). CONCLUSION: A simple risk score accurately predicts 5-year mortality after replacement in CRT-D patients, as patients with a risk score of greater than 2.5 are at high risk of dying despite ICD protection.


Assuntos
Fibrilação Atrial , Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Insuficiência Cardíaca , Idoso , Fibrilação Atrial/terapia , Terapia de Ressincronização Cardíaca/efeitos adversos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Humanos , Masculino , Estudos Prospectivos , Fatores de Risco , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA