Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
J Cardiothorac Surg ; 19(1): 164, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38561823

RESUMO

BACKGROUND: Mitral regurgitation is a frequent valvular disease, with an increasing prevalence. We analyzed the short-term outcomes of mitral valve repair procedures conducted in our clinic using a new semirigid annuloplasty ring featuring a gradual saddle shape design. METHODS: We retrospectively analyzed mitral valve repair surgeries performed at our Institution between December 2019 and November 2021 with the MEMO 4D semirigid annuloplasty ring. RESULTS: In total, 53 patients were included in the study. Mean patient age was 63.6 ± 11.7 years. Most patients presented with degenerative mitral valve regurgitation (N = 44; 83%). The grade of mitral regurgitation was equal or more than 3 + in 98.1% of the patients (N = 52). The most used ring size was size 34 mm (N = 30, 56.6%). There was no intraoperative or hospital mortality. No cases of stroke, bleeding, endocarditis or other major complications occurred. At discharge, most patients were in NYHA class I. Postoperative echocardiographic results showed no (90.6%) or 1+ (5.7%) mitral valve regurgitation. Only 1 patient (1.9%) presented with mitral valve regurgitation grade 2+. Mean postoperative transvalvular gradient was low (mean = 3.3 ± 1.2 mmHg). No cases of LVOT obstruction or systolic anterior motion occurred. CONCLUSIONS: Our series showed excellent mitral valve competency and very satisfactory early clinical outcomes. The transesophageal echocardiographic follow-up, despite obtained in a limited number of patients, further confirmed the effectiveness of findings of this preliminary experience.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Anuloplastia da Valva Mitral , Insuficiência da Valva Mitral , Humanos , Pessoa de Meia-Idade , Idoso , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/etiologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Estudos Retrospectivos , Desenho de Prótese , Anuloplastia da Valva Mitral/efeitos adversos , Ecocardiografia , Resultado do Tratamento
2.
Artigo em Inglês | MEDLINE | ID: mdl-37510561

RESUMO

Epidemiological studies show that new cases of young oncology patients are increasing by 400,000 every year. Psychological literature has shown that receiving an oncological diagnosis can cause significant psychological stress and discomfort. However, the experiences of young patients and their caregivers as they confront this challenge are not yet fully understood. This paper adopts a qualitative methodological approach to explore how young patients with an oncological diagnosis and their parents make sense of the experiential challenges they face. Thus, the research realized 18 semi-structured interviews, 11 of which were with pediatric and adolescent oncology patients, and 7 of which were with 6 mothers and 1 father. The qualitative thematic analysis revealed that the oncological diagnosis triggers different emotions taking the scene in the attempt to cope with the threats of meaning that the diagnosis poses. However, such intense experience promotes transformative feelings in parents and young patients, leading to important personal growth. Lastly, this article discusses the need to improve palliative psychological care competences in pediatric oncology. By providing comprehensive psychological care to young oncology patients and their families, healthcare providers can mitigate the psychological stress and pain associated with the diagnosis and treatment of cancer.


Assuntos
Cuidadores , Neoplasias , Humanos , Criança , Adolescente , Cuidadores/psicologia , Neoplasias/diagnóstico , Neoplasias/psicologia , Oncologia , Estresse Psicológico/etiologia , Cuidados Paliativos/psicologia , Pesquisa Qualitativa
3.
Eur J Cardiothorac Surg ; 62(2)2022 07 11.
Artigo em Inglês | MEDLINE | ID: mdl-35775935

RESUMO

OBJECTIVES: To compare procedural and in-hospital outcomes of patients undergoing sutureless (Perceval, Livanova PLC, London, UK) and rapid deployment (Intuity Elite, Edwards Lifesciences, Irvine, CA, USA) aortic valve replacement (group 1) versus sutured aortic valve replacement (group 2). METHODS: Patients receiving isolated aortic valve replacement between 2014 and 2020 were analysed using data from the Sutureless and Rapid Deployment International Registry. Patients in group 1 and group 2 were propensity-score matched in a 1:1 ratio. RESULTS: A total of 7708 patients were included in the study. After matching, 2 groups of 2643 each were created. Patients in group 1 were more likely to undergo minimally invasive approaches and were associated with shorter operative times when compared with group 2. Overall in-hospital mortality was similar between groups. While an increased risk of stroke was observed in group 1 in the first study period (2014-2016; relative risk 3.76, P < 0.001), no difference was found in more recent year period (relative risk 1.66, P = 0.08; P for heterogeneity 0.003). Group 1 was associated with reduced rates of postoperative low cardiac output syndrome, atrial fibrillation and mild aortic regurgitation. New pacemaker implant was three-fold higher in group 1. CONCLUSIONS: Our findings showed significant differences in procedural and clinical outcomes between the study groups. These results suggest that sutureless and rapid deployment aortic valve replacement should be considered as part of a comprehensive valve programme. The knowledge of the respective post-aortic valve replacement benefits for different valve technologies may result in patient-tailored valve selection with improved clinical outcomes.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Procedimentos Cirúrgicos sem Sutura , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Desenho de Prótese , Sistema de Registros , Resultado do Tratamento
4.
J Cardiothorac Vasc Anesth ; 36(8 Pt A): 2636-2642, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-34417098

RESUMO

Limited data are available on the use of the prone position in cardiac surgery. Concerns in performing this maneuver in open cardiac surgery due to the risk of post-sternotomy wound infections and hemodynamic instability do not seem to be supported by existing evidence. Indeed, available data show that prone positioning may improve gas exchange in cardiac surgery patients as well. However, previous studies of prone positioning in this setting were heterogeneous in patient characteristics and outcomes evaluated. As a result, whether prone positioning also may be effective in reducing mortality in patients with postoperative acute respiratory failure, particularly in those who underwent surgery under extracorporeal circulation, remains to be clearly elucidated. The aim of this article is to provide an overview of available literature, which seems to suggest the efficacy of prone positioning, and to make an in-depth analysis of the studies on this topic by evaluating the efficacy of this maneuver on hard endpoints.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Síndrome do Desconforto Respiratório , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Humanos , Posicionamento do Paciente , Período Pós-Operatório , Decúbito Ventral
5.
Ann Thorac Surg ; 108(1): 99-105, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30684479

RESUMO

BACKGROUND: Several studies reported high rates of postoperative permanent pacemaker (PPM) implantation, which has been described as the "Achilles' heel" of sutureless aortic valve replacement (AVR). METHODS: From July 2010 to December 2017, 3,158 patients with symptomatic, severe aortic valve stenosis were referred to the Department of Cardiac Surgery (Klinikum Nürnberg - Paraclesus Medical University, Nuremberg, Germany), and 512 received a Perceval sutureless bioprosthesis (LivaNova PLC, London, United Kingdom). Thirty-nine patients who had been discharged with concomitant PPM implantation were reevaluated. RESULTS: After a cumulative follow-up of 1,534 months (100% complete, median 50 months, interquartile range 30 months, maximum 76 months, minimum 3 months), a total of 22 patients were still pacemaker dependent. Kaplan-Meier analysis showed pacemaker-dependent rhythm in 92.0%, 80.0%, 49.4%, and 32.3% of patients at 1, 2, 4, and 5 years, respectively. At Cox regression analysis, pressure during valve deployment (hazard ratio, 79.41; p = 0.0003) and "late-onset" atrioventricular block were found to be independent predictors of sinus rhythm restoration (hazard ratio, 0.16; p = 0.0061). Log-rank test showed significantly lower pacemaker dependency rates in patients with "low-pressure" prosthesis implantation (p < 0.0001). CONCLUSIONS: This study shows that several technical measures, including appropriate annulus decalcification, precise positioning of guiding sutures, release of traction sutures applied to the valve commissures, and ballooning with reduced pressure, all reduce the rate of PPM implantation after sutureless AVR. Furthermore, a high proportion of patients were found to be no longer pacemaker dependent at follow-up.


Assuntos
Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Marca-Passo Artificial , Técnicas de Sutura , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Modelos de Riscos Proporcionais
8.
Clin Chem Lab Med ; 53(4): 567-73, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24897401

RESUMO

BACKGROUND: Systemic bacterial infection carries a high risk of mortality in critical care patients. Improvements in diagnostic procedures are required for effective management of sepsis. Recently, the soluble CD14 subtype, or presepsin, has been suggested as a reliable marker of sepsis, and we set out to compare its diagnostic performance with that of procalcitonin (PCT). We focused on a cohort of septic patients who, during their hospitalization, relapsed after a period of clinical relief from symptoms. METHODS: In total 21 adult patients were studied during their hospitalization in the Critical Care Unit of Policlinico Umberto I hospital; 74 plasma samples were collected at multiple time points, and presepsin levels were measured using a PATHFAST analyzer. RESULTS: Presepsin and PCT were significantly lower in healthy controls than in sepsis or severe sepsis (p<0.001), both enabled a significant difference to be detected between systemic inflammatory response syndrome (SIRS) and severe sepsis (p<0.05). The area under the curve (AUC) calculated from the receiver operating characteristic (ROC) curve analysis was 0.888 for presepsin and 0.910 for PCT. In those patients in whom a clinical recurrence of sepsis was observed, while PCT levels normalized during the transient remission phase, presepsin levels (>1000 pg/mL) remained high. CONCLUSIONS: This study confirms the importance of monitoring a combination of several biomarkers in order to obtain a reliable diagnosis. Maximal presepsin levels could alert clinicians not to suspend antibiotic treatments and to carefully monitor septic patients' state of health, even after clinical symptoms have disappeared and PCT levels returned to normal.


Assuntos
Infecções Bacterianas/sangue , Infecções Bacterianas/diagnóstico , Cuidados Críticos , Receptores de Lipopolissacarídeos/sangue , Fragmentos de Peptídeos/sangue , Adulto , Infecções Bacterianas/terapia , Biomarcadores/sangue , Estudos de Coortes , Feminino , Hospitalização , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva
9.
J Pharm Biomed Anal ; 54(1): 67-73, 2011 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-20813481

RESUMO

During late phase development of the selective NK1 receptor antagonist casopitant mesylate, a de-fluorinated impurity was discovered and quantified by an orthogonal analytical approach, using NMR and LC-MS. A dedicated (19)F NMR method was initially developed for first line identification and semi-quantification of the impurity. Subsequently, a more accurate quantification was achieved by means of a selective normal-phase LC-MS method, which was fully validated. The results obtained on the development batches of the drug substance were used by the project team to set up a suitable control strategy and ultimately to ensure patient safety and the progression of the project.


Assuntos
Química Farmacêutica/métodos , Contaminação de Medicamentos , Flúor/química , Piperazinas/análise , Piperidinas/análise , Técnicas de Química Analítica , Cromatografia Líquida/métodos , Halogenação , Espectroscopia de Ressonância Magnética/métodos , Espectrometria de Massas/métodos , Modelos Químicos , Preparações Farmacêuticas/química , Controle de Qualidade , Reprodutibilidade dos Testes
10.
Rapid Commun Mass Spectrom ; 24(17): 2650-4, 2010 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-20740542

RESUMO

The introduction of Quality by Design (QbD) in Drug Development has resulted in a greater emphasis on chemical process understanding, in particular on the origin and fate of impurities. Therefore, the identification and quantitation of low level impurities in new Active Pharmaceutical Ingredients (APIs) play a crucial role in project progression and this has created a greater need for sensitive and selective analytical methodology. Consequently, scientists are constantly challenged to look for new applications of traditional analytical techniques. In this context a normal-phase liquid chromatography/electrospray ionization mass spectrometry (LC/ESI-MS) method was developed to determine the amount of a de-fluorinated analogue impurity in Casopitant Mesylate, a new API under development in GlaxoSmithKline, Verona. Normal-phase LC provided the selectivity needed between our target analyte and Casopitant, while a single quadrupole mass spectrometer was used to ensure the sensitivity needed to detect the impurity at <0.05%w/w. Standard solutions and samples were prepared in heptane/ethanol (50:50, v/v) containing 1% of 2 M NH(3) in ethanol; the mobile phase consisted of heptane/ethanol (95:5, v/v) with isocratic elution (flow rate: 1.0 mL/min, total run time: 23 min). To allow the formation of ions in solutions under normal-phase (apolar) conditions, a post-column infusion of a solution of 0.1% v/v of formic acid in methanol was applied (flow rate: 200 microL/min). The analysis was carried out in positive ion mode, monitoring the impurity by single ion monitoring (SIM). The method was fully validated and its applicability was demonstrated by the analysis of real-life samples. This work is an example of the need for selective and accurate methodology during the development of a new chemical entity in order to develop an appropriate control strategy for impurities to ultimately ensure patient safety.


Assuntos
Cromatografia Líquida/métodos , Piperazinas/análise , Piperidinas/análise , Espectrometria de Massas por Ionização por Electrospray/métodos , Contaminação de Medicamentos , Descoberta de Drogas , Halogenação , Piperazinas/química , Piperidinas/química , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...