Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
EuroIntervention ; 20(8): e504-e510, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38629420

RESUMO

The treatment of coronary artery disease (CAD) in patients with severe aortic valve stenosis (AVS) eligible for transcatheter aortic valve implantation (TAVI) is not supported by clinical evidence, and the role of physiology over anatomy as well as the timing of coronary intervention are not defined. FAITAVI (ClinicalTrials.gov: NCT03360591) is a nationwide prospective, open-label, multicentre, randomised controlled study comparing the angiography-guided versus the physiology-guided coronary revascularisation strategy in patients with combined significant CAD and severe AVS undergoing TAVI. Significant CAD will be defined as coronary stenosis ≥50%, as assessed by visual estimation in vessels ≥2.5 mm. Physiology will be tested by fractional flow reserve (FFR) and instantaneous wave-free ratio (iFR). The study will be conducted at 15 sites in Italy. In the angiography arm, percutaneous coronary intervention (PCI) will be performed either before TAVI, during the TAVI procedure - before or after the valve implantation - or within 1 month±5 days of the valve implantation, left to the operator's decision. In the physiology arm, FFR and iFR will be performed before TAVI, and PCI will be indicated for FFR ≤0.80, otherwise the intervention will be deferred. In case of borderline values (0.81-0.85), FFR and iFR will be repeated after TAVI, with PCI performed when needed. With a sample size of 320 patients, the study is powered to evaluate the primary endpoint (a composite of death, myocardial infarction, stroke, major bleeding, or ischaemia-driven target vessel revascularisation). TAVI indication, strategy and medical treatment will be the same in both groups. After discharge, patients will be contacted at 1, 6, 12 and 24 months after the procedure to assess their general clinical status, and at 12 months for the occurrence of events included in the primary and secondary endpoints. FAITAVI is the first randomised clinical trial to investigate "optimal" percutaneous coronary intervention associated with TAVI in patients with severe AVS and CAD.


Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Humanos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Estudos Prospectivos , Resultado do Tratamento , Estudos Multicêntricos como Assunto , Ensaios Clínicos Controlados Aleatórios como Assunto
2.
J Clin Med ; 13(7)2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38610866

RESUMO

Background: The management of cardiogenic shock (CS) after ACS has evolved over time, and the development of a multidisciplinary team-based approach has been shown to improve outcomes, although mortality remains high. Methods: All consecutive patients with ACS-CS admitted at our CICU from March 2012 to July 2021 were included in this single-center retrospective study. In 2019, we established a "shock team" consisting of a cardiac intensivist, an interventional cardiologist, an anesthetist, and a cardiac surgeon. The primary outcome was in-hospital mortality. Results: We included 167 patients [males 67%; age 71 (61-80) years] with ischemic CS. The proportion of SCAI shock stages from A to E were 3.6%, 6.6%, 69.4%, 9.6%, and 10.8%, respectively, with a mean baseline serum lactate of 5.2 (3.1-8.8) mmol/L. Sixty-six percent of patients had severe LV dysfunction, and 76.1% needed ≥ 1 inotropic drug. Mechanical cardiac support (MCS) was pursued in 91.1% [65% IABP, 23% Impella CP, 4% VA-ECMO]. From March 2012 to July 2021, we observed a significative temporal trend in mortality reduction from 57% to 29% (OR = 0.90, p = 0.0015). Over time, CS management has changed, with a significant increase in Impella catheter use (p = 0.0005) and a greater use of dobutamine and levosimendan (p = 0.015 and p = 0.0001) as inotropic support. In-hospital mortality varied across SCAI shock stages, and the SCAI E profile was associated with a poor prognosis regardless of patient age (OR 28.50, p = 0.039). Conclusions: The temporal trend mortality reduction in CS patients is multifactorial, and it could be explained by the multidisciplinary care developed over the years.

3.
EuroIntervention ; 18(17): 1418-1427, 2023 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-36880333

RESUMO

BACKGROUND: Initial data about the performance of the new-generation SAPIEN 3 Ultra (S3U) valve are highly promising. However, evidence about the longer-term performance and safety of the S3U is scarce. AIMS: We aimed to investigate the 1-year clinical and echocardiographic outcomes of transcatheter aortic valve implantation (TAVI) using the S3U compared with its predecessor, the SAPIEN 3 valve (S3). METHODS: The SAPIEN 3 Ultra registry included consecutive patients who underwent transfemoral TAVI at 12 European centres with the S3U or S3 between October 2016 and December 2020. One-to-one propensity score (PS) matching was performed to account for differences in baseline characteristics. The primary outcomes of interest were all-cause death and the composite of all-cause death, disabling stroke and hospitalisation for heart failure at 1 year. RESULTS: The overall study cohort encompassed 1,692 patients treated with either the S3U (n=519) or S3 (n=1,173). The PS-matched population had a total of 992 patients (496 per group). At 1 year, the rate of death from any cause was 4.9% in the S3U group and 6.3% in the S3 group (p=0.743). Similarly, there were no significant differences in the rates of the primary composite outcome (9.5% in the S3 group and 6.6% in the S3U group; p=0.162). The S3U was associated with lower rates of mild paravalvular leak (PVL) compared with the S3 (odds ratio 0.63, 95% confidence interval: 0.44 to 0.88; p<0.01). No significant differences in transprosthetic gradients were observed between the two groups. CONCLUSIONS: Compared with the S3, the S3U transcatheter heart valve was associated with similar 1-year clinical outcomes but reduced rates of mild PVL.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Resultado do Tratamento , Sistema de Registros , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Desenho de Prótese
5.
Clin Cardiol ; 45(9): 913-920, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35733352

RESUMO

BACKGROUND: The itAlian pRospective Study on CANGrELOr (ARCANGELO) was aimed to assess the safety of using cangrelor during percutaneous coronary intervention (PCI) in patients with acute coronary syndromes (ACS) in the daily practice. HYPOTHESIS: The safety of cangrelor after the transition to oral P2Y12 inhibitors was evaluated as the incidence of bleeding outcomes in the 30 days following PCI according to postauthorization safety study guidelines. METHODS: Adults with ACS who were treated with cangrelor in one of the 28 centers involved in the study. Patients who consented to participate were followed in the 30 days following their PCI. Bleedings (Bleeding Academic Research Consortium [BARC] classification), major adverse cardiac events (MACEs), and adverse events were recorded. The interim results at two-thirds of the enrollment period are presented. RESULTS: A total of 17 bleedings were observed in the 320 patients who completed the study at this stage. All bleedings were classified as BARC Type 1-2, except for one case of Type 3a (vessel puncture site hematoma). Four patients experienced MACEs (2 acute myocardial infarctions, 1 sudden cardiac death, 1 noncardiovascular death due to respiratory distress, and multiorgan failure). None of the bleedings was rated as related to cangrelor. CONCLUSIONS: The interim results of the ARCANGELO study provide a preliminary confirmation that the use of cangrelor on patients with ACS undergoing PCI is not associated with severe bleedings.


Assuntos
Síndrome Coronariana Aguda , Intervenção Coronária Percutânea , Síndrome Coronariana Aguda/cirurgia , Monofosfato de Adenosina/análogos & derivados , Adulto , Hemorragia/induzido quimicamente , Hemorragia/epidemiologia , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Inibidores da Agregação Plaquetária/efeitos adversos , Estudos Prospectivos , Antagonistas do Receptor Purinérgico P2Y/efeitos adversos , Resultado do Tratamento
6.
Int J Cardiol ; 361: 55-60, 2022 08 15.
Artigo em Inglês | MEDLINE | ID: mdl-35500820

RESUMO

OBJECTIVES: The aim of this study was to evaluate outcomes of real-world patients with aortic stenosis (AS) undergoing transcatheter aortic valve replacement (TAVR) with the 34 mm Evolut R (Medtronic, Minneapolis, Minnesota). BACKGROUND: Larger aortic annulus has been associated with increased incidence of paravalvular leaks (PVLs) after TAVR. However, little is known, so far, about the performance of the 34 mm Evolut R in this setting. METHODS: From the multicenter, international, retrospective Horizontal Aorta in Transcatheter Self-expanding Valves (HORSE) registry, including patients who underwent TAVR for native severe AS, we selected patients treated with the 34 mm Evolut R evaluating procedural characteristics and VARC-2 defined device success. We also compared 34 mm Evolut R with other Evolut R sizes. RESULTS: Among the 4434 patients included in the registry, 572 (13%) received the 34 mm Evolut R valve. Mean age was 80.8 ± 6.5 years and the median STS PROM score was 4 [interquartile range 2-6]. Device success was achieved in 87.4% with 7.7% of PVLs; moreover, the rate of permanent pacemaker implantation (PPMI) was 22.4%. Patients who underwent 34 mm Evolut R implantation experienced more in-hospital permanent pacemaker implantation (22.4% vs. 15%; p < 0.001). At multivariate analysis, 34 mm Evolut R did not affect device success (OR: 0.81 [0.60-1.09]; p = 0.151). Device success was consistent with other THVs sizes (87.4% vs. 89.6%; p = 0.157). CONCLUSIONS: THV replacement in patients requiring 34 mm Evolut R has an acceptable performance. Compared to other Medtronic sizes it demonstrated to be comparable in terms of device success, despite an increased rate of pacemaker implantation.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Sistema de Registros , Estudos Retrospectivos , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
8.
Eur Heart J Acute Cardiovasc Care ; 10(9): 999-1006, 2021 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-34389852

RESUMO

AIMS: To report the incidence, the predictors and clinical impact of device-related complications (DRCs) in the IMP-IT (IMPella Mechanical Circulatory Support Device in Italy) registry. Impella is percutaneous left ventricular assist devices, which provides mechanical circulatory support both in cardiogenic shock (CS) and high-risk percutaneous coronary intervention (HR-PCI). The IMP-IT registry is a multicentre registry evaluating the trends in use and clinical outcomes of Impella in Italy. METHODS AND RESULTS: A total of 406 patients have been included in this registry: 56.4% in the setting of CS, while 43.6% patients in the setting of HR-PCI. DRCs were defined as a composite endpoint of access-site bleeding, limb ischaemia, vascular complication requiring treatment, haemolysis, aortic injury, and left ventricular perforation. DRC incidence in the overall population was 25.6%, with significantly higher rate in the CS (37.1%) than in the HR-PCI (10.7%) group. The most frequent complication was haemolysis (11.8%), which occurred almost exclusively in CS population. Access-site bleeding was observed in 9.6% of the overall population, with no significant difference between the two groups. Limb ischaemia was observed in 8.3% of the overall population, with significantly higher rate in the CS group. CS and right ventricular dysfunction appear as the strongest independent predictors of DRC. One-year mortality in patients with DRC appears higher than in patients with no DRC. However, DRC was not confirmed as an independent predictor of 1-year mortality at multivariate analysis. CONCLUSION: In the IMP-IT registry, the rate of DRC was 25.6%, with CS being the strongest independent predictor. DRC was not found as an independent predictor of 1-year mortality.


Assuntos
Coração Auxiliar , Intervenção Coronária Percutânea , Humanos , Coração Auxiliar/efeitos adversos , Sistema de Registros , Estudos Retrospectivos , Choque Cardiogênico/epidemiologia , Choque Cardiogênico/etiologia , Resultado do Tratamento
10.
Int J Cardiol ; 338: 58-62, 2021 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-34090956

RESUMO

BACKGROUND: Horizontal aorta (HA) is an anatomical feature that can pose significant technical challenges for the successful positioning of the bioprosthetic valve during transcatheter aortic valve replacement (TAVR). Physiological range of aortic angle (AA) is unknown; hence there is no cutoff AA for classifying HA. Moreover, patient characteristics predicting HA are under-investigated. METHODS: This was a retrospective analysis of prospective collected data from 16 heart valve centers in Europe. The study utilized a common dataset with a priori agreed-upon definitions and variables. Eligible patients underwent TAVR between 2014 and 2020 and had multidetector computed tomographic imaging data available for determining the AA. The analysis described the distribution of AA and potential predictors of HA. Inter-center variability was also explored. RESULTS: For 4022 patients analyzed, the mean AA ± standard deviation was 49.4° ± 9.4° (median 49°, inter-quartile range [IQR] 12°, range 18-90°). There was no significant difference in mean AA between men and women (49.4° ± 9.1° vs. 49.6° ± 9.3°, respectively; p = 0.53); therefore, 49.4° was accepted as the cutoff value for HA in subsequent analyses. Covariates significantly associated with HA included age (odds ratio [OR]: 1.02, 95% confidence interval [CI]: 1.01-1.04, p < 0.001), body mass index (OR: 1.06, 95% CI: 1.05-1.08, p < 0.01), previous cardiac surgery (OR: 0.58, 95% CI: 0.45-0.75, p < 0.001), and porcelain aorta (OR: 0.66, 95% CI: 0.52-0.85, p = 0.001). Some inter-center variability was observed. CONCLUSIONS: We defined 49.4° as the mean AA, and also associated predictors of HA in a large case series of patients with severe aortic stenosis candidates for TAVR.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Aorta , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Europa (Continente) , Feminino , Humanos , Masculino , Estudos Prospectivos , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
11.
Int J Cardiol ; 333: 69-76, 2021 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-33662485

RESUMO

BACKGROUND: Women present specific risks for transcatheter aortic valve replacement (TAVI) but there are scarce sex-based analysis. The aim of this study was to explore the risk of vascular/bleeding complications in females vs. males that underwent TAVI and the impact of red blood cell (RBC) transfusion. METHODS: TRITAVI-Women is a retrospective analysis in 13 European institutions. Propensity score based on pairs of different sex was performed and global outcomes, vascular/bleeding risk factors were determined. Afterwards, the female population of the study was divided into two groups according to the need of RBC transfusion and the risk for mortality, AKI, MI, stroke at 30-days and at 1-year were compared as a combined endpoint (primary endpoint) and separately (secondary endpoints). RESULTS: The global study population included 5837 patients. Females presented more advanced NYHA class, chronic kidney disease, and baseline anemia. Vascular/bleeding complications and RBC transfusion were more common in women. However, 1-year mortality was lower for women in the matched cohort (8.1% vs.10.3%, p = 0.028). The need for RBC transfusion was an independent predictor of higher incidence of the primary endpoint at 30-day and 1-year. The main predictor of RBC transfusion in women was the presence of baseline anemia. CONCLUSIONS: Women present lower risk of mortality than men at 1-year follow up, but not at 30-day due to higher rates of vascular/bleeding complications. RBC transfusion was also more often required in women and was an independent predictor or poorer outcomes. The treatment of pre-existing anemia before TAVI might improve the short-term results in women.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Transfusão de Eritrócitos/efeitos adversos , Feminino , Humanos , Masculino , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
12.
Cardiovasc Revasc Med ; 30: 1-8, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33077393

RESUMO

AIM: To compare the long-term outcomes of patients implanted with Absorb bioresorbable scaffold (BRS) with optimal versus suboptimal technique. METHODS AND RESULTS: All patients who received an Absorb between March 2012 and January 2016 were selected from 19 Italian centers databases to assess the impact of an optimal implantation technique (CIAO criteria) on long-term device-oriented composite end-point (DOCE) - including cardiac death (CD), target-vessel myocardial infarction (TV-MI) and ischemia-driven target lesion revascularization (ID-TLR) - on its single components and on scaffold thrombosis (ScT). CIAO criteria consist of predilation (balloon/vessel ratio 1:1), correct sizing (BRS/proximal reference vessel diameter -RVD- ratio 0.8-1.2) and high-pressure postdilation with non-compliant (NC) balloon (≥20 atm for balloon/BRS ratio 1:1 or ≥16 atm for a 0.25-0.5 mm oversized balloon). Among the 1.434 patients analyzed, 464 (32.4%) fulfilled all CIAO criteria for every BRS implanted (CIAO 3 group), while 970 (67.6%) did not in at least one of the received BRS (CIAO 0-1-2 group). At 31.0 (interquartile range -IQR- 24.8-38.5) months follow-up, CIAO criteria did not impact on DOCE (8.2% vs. 8.0%, p = 0.92), ID-TLR (6.9% vs. 7.1%, p = 0.72) or ScT (1.9% vs. 1.8%, p = 0.80) in the overall population. At multivariate analysis overall BRS length (p = 0.001), severely calcified lesions (p = 0.03) and absence of CIAO criteria (CIAO 0, p = 0.005) were independent predictors of DOCE in long-term follow-up. CONCLUSION: Our data suggest that strict application of an optimal Absorb implantation technique doesn't improve long-term DOCE or ScT but may mitigate the worse outcome of patients with calcific lesions.


Assuntos
Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Implantes Absorvíveis , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Desenho de Prótese , Sistema de Registros , Fatores de Tempo , Resultado do Tratamento
13.
G Ital Cardiol (Rome) ; 21(11 Suppl 1): 4S-12S, 2020 11.
Artigo em Italiano | MEDLINE | ID: mdl-33295329

RESUMO

Since its advent, transcatheter aortic valve implantation (TAVI) has experienced a continuous expansion, thanks to extraordinary clinical results and to the dramatic increase of safety, enabled by improvements of prosthesis and delivery systems, refinement of implantation techniques, increasing operator experience, and use of computed tomography scan for procedural planning. However, complications rates are still not negligible. As vascular complications, and, particularly, access-related complications are among the most frequent adverse events, all TAVI operators should know how to prevent and how to manage those potentially catastrophic situations. Here we provide an overview of the most frequent access site vascular complications and the respective treatment options.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Humanos , Tomografia Computadorizada por Raios X , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
14.
Circ Cardiovasc Interv ; 13(12): e009026, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33272037

RESUMO

BACKGROUND: There is no consensus on the benefit of red blood cell (RBC) transfusion after transcatheter aortic valve replacement. METHODS: The multicenter Transfusion Requirements in Transcatheter Aortic Valve Implantation (TRITAVI) registry retrospectively included patients after transfemoral transcatheter aortic valve replacement; propensity score-matching identified pairs of patients with and without RBC transfusion. The primary end point was 30-day mortality; nonfatal myocardial infarction, cerebrovascular accident, and stage 2 to 3 acute kidney injury at 30 days were secondary end points. We repeated propensity score-matching according to the hemoglobin nadir, hemoglobin drop, and in the subgroup of uncomplicated patients, without major vascular complications or major bleeding. RESULTS: Among 2587 patients, RBC transfusion was administered in 421 cases (16%). The primary end point occurred in 104 (4.0%) patients, myocardial infarction in 9 (0.4%), cerebrovascular accident in 38 (1.5%), and acute kidney injury in 125 (4.8%) cases. In the 842 propensity-matched patients, RBC transfusion was associated with increased mortality (hazard ratio, 2.07 [95% CI, 1.06-4.05]; P=0.034) and acute kidney injury (hazard ratio, 4.35 [95% CI, 2.21-8.55]; P<0.001). Interaction testing between RBC transfusion and mortality was not statistically significant in the above-mentioned subgroups, and such association was not documented in the corresponding propensity score-matched cohorts. In the multivariable Cox proportional hazards regression model, major vascular complications (P=0.044), major bleeding (P=0.041), and RBC transfusion (P=0.048) were independent correlates of 30-day mortality. CONCLUSIONS: RBC transfusion correlates with increased mortality and acute kidney injury early after transcatheter aortic valve replacement and is an independent predictor of 30-day mortality, irrespective of periprocedural major bleeding and vascular complications. Registration: URL: https://www.clinicaltrials.gov. Unique identifier: NCT03740425.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Humanos , Complicações Pós-Operatórias , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
15.
Int J Cardiol ; 293: 84-90, 2019 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-31174920

RESUMO

Percutaneous coronary intervention (PCI) is establishing as the last remaining revascularization option in an increasing number of patients affected by complex coronary artery disease not suitable for surgery. Over the past decade, percutaneous left ventricular assist device (pLVAD) has increasingly replaced intra-aortic balloon pump to provide hemodynamic support during such non-emergent complex high-risk indicated procedures (CHIP) averting the risk of circulatory collapse and of adverse events in long lasting and/or complicated procedures. This review article aims to report the key factors to define CHIP, to summarize the available pLVAD which have CE mark for temporary mechanical LV support and to discuss the rationale of their use in this subset of patients. Based on the expertise of the Italian Society of Interventional Cardiology working group, with the endorsement from Spanish and Portuguese Society of Interventional Cardiology working groups, it will provide several practical suggestions in regards to the use of pLVAD in different clinical CHIP scenarios.


Assuntos
Cardiologia/normas , Consenso , Prova Pericial/normas , Coração Auxiliar/normas , Intervenção Coronária Percutânea/normas , Sociedades Médicas/normas , Cardiologia/métodos , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/epidemiologia , Doença da Artéria Coronariana/cirurgia , Prova Pericial/métodos , Humanos , Itália/epidemiologia , Intervenção Coronária Percutânea/métodos , Portugal/epidemiologia , Fatores de Risco , Espanha/epidemiologia
16.
Int J Cardiol ; 290: 21-26, 2019 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-31104821

RESUMO

BACKGROUND: Large prospective studies on the use of bioresorbable vascular scaffolds (BVS) for diffuse coronary artery disease are lacking. IT DISAPPEARS is a large multicentre prospective registry investigating the short and long-term outcomes of everolimus-eluting BVS in patients with long coronary lesions and/or multivessel coronary artery disease (ClinicalTrials.gov: NCT02004730). We hereby report the 2-year outcomes of the registry. METHODS: We enrolled 1002 patients with complex lesions undergoing implantation of 2040 BVS with a prespecified technique including predilation, correct sizing, and postdilation with non-compliant balloons. The primary endpoint was the rate of device-oriented composite endpoint (DOCE), consisting of cardiac death, target vessel-related myocardial infarction (MI), and ischaemia-driven target lesion revascularization (TLR). Secondary endpoints included: 1) patient-oriented composite endpoint (POCE), consisting of all-cause mortality, all infarctions and all revascularisations; 2) definite/probable scaffold thrombosis. RESULTS: Clinical presentation was an acute coronary syndrome in 59.8% of patients. Total BVS length implanted was 47 ±â€¯22 mm. Postdilation of all scaffolds per patient was performed in 96.8%, while optimal implantation as per study guidelines was applied in 71.4%. Through 2-year follow-up, DOCE occurred in 9.5% of patients (cardiac death 0.6%, target vessel-related MI 5.3%, TLR 6.6%). The rate of POCE was 16.6% and of scaffold thrombosis 1.1%. Female gender, total length of coronary lesions, treatment of bifurcation lesions and use of 2.5 mm scaffolds were independent predictors of DOCE. CONCLUSIONS: The 2-year results of IT-DISAPPEARS show that BVS may yield acceptable clinical outcomes in patients with complex coronary lesions when the implantation technique is appropriate.


Assuntos
Implantes Absorvíveis/tendências , Síndrome Coronariana Aguda/epidemiologia , Síndrome Coronariana Aguda/terapia , Stents Farmacológicos/tendências , Everolimo/administração & dosagem , Sistema de Registros , Idoso , Feminino , Seguimentos , Humanos , Itália/epidemiologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Tempo , Alicerces Teciduais/tendências , Resultado do Tratamento
17.
JACC Cardiovasc Interv ; 10(18): 1855-1864, 2017 09 25.
Artigo em Inglês | MEDLINE | ID: mdl-28935077

RESUMO

OBJECTIVES: The aim of this study was to assess the feasibility and clinical results following a pre-specified bioresorbable scaffold (Absorb BVS) implantation strategy in patients with ST-segment elevation myocardial infarction (STEMI). BACKGROUND: Concerns were raised about the safety of Absorb because a non-negligible rate of thrombosis was reported within 30 days and at midterm follow-up after primary percutaneous coronary intervention. METHODS: This was a prospective, multicenter study of patients with STEMI (<75 years of age with symptom onset <12 h) undergoing primary percutaneous coronary intervention with Absorb following a dedicated implantation protocol. The primary endpoint was a device-oriented composite endpoint of cardiac death, target vessel myocardial infarction, and ischemia-driven target lesion revascularization within 30 days. RESULTS: During the study period, 505 patients with STEMI (16.9% of the overall STEMI population) were treated with the Absorb BVS. The mean age was 56.6 ± 9.4 years, and 487 patients (96.4%) were in Killip class I or II at admission. According to the study protocol, direct Absorb implantation was feasible in 47 patients (9.3%), whereas post-dilatation was performed in 468 cases (92.7%). Procedural success was attained in 94.8% of the cases. Dual antiplatelet therapy with ticagrelor or prasugrel was administered at discharge in 481 patients (95.1%). At 30-day follow-up, the hierarchical device-oriented composite endpoint rate was 0.6% (0.4% cardiac death, 0.2% target vessel myocardial infarction and ischemia-driven target lesion revascularization). One episode (0.2%) of probable scaffold thrombosis was reported. CONCLUSIONS: A pre-specified Absorb implantation strategy in real-world patients with STEMI undergoing primary percutaneous coronary intervention was feasible and associated with a low 30-day device-oriented composite endpoint rate. Mid- and long-term follow-up is strongly needed to eventually confirm these early results. (Use of BVS in ST-Segment Elevation Myocardial Infarction [STEMI]: The BVS STEMI STRATEGY-IT Prospective Registry [STRATEGY-IT]; NCT02601781).


Assuntos
Implantes Absorvíveis , Angioplastia Coronária com Balão/instrumentação , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Adenosina/administração & dosagem , Adenosina/análogos & derivados , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/mortalidade , Aspirina/administração & dosagem , Trombose Coronária/etiologia , Quimioterapia Combinada , Feminino , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Inibidores da Agregação Plaquetária/administração & dosagem , Cloridrato de Prasugrel/administração & dosagem , Estudos Prospectivos , Desenho de Prótese , Recidiva , Fatores de Risco , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Infarto do Miocárdio com Supradesnível do Segmento ST/mortalidade , Ticagrelor , Fatores de Tempo , Resultado do Tratamento
18.
J Thorac Dis ; 9(Suppl 9): S898-S902, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28894595

RESUMO

BACKGROUND: To evaluate how the 3-year results from the "A clinical evaluation to compare the safety, efficacy and performance of ABSORB everolimus eluting bioresorbable vascular scaffold (BVS) system against XIENCE everolimus eluting coronary stent system in the treatment of subjects with ischemic heart disease caused by de novo native coronary artery lesions" (ABSORB II) trial have influenced clinical practice among Italian interventional cardiologists. METHODS: We performed a survey among 95 interventional cardiologists sending a brief questionnaire by electronic mail. We collected 65 replies and analysed the data. RESULTS: The opinion of the operators regarding the two main endpoints of the study ABSORB II was conflicting. However, 66% of the operators considered at least one of the two co-primary endpoints (late lumen loss or vasomotion) unreliable and not reflecting clinical practice. Asking about an explanation for the negative results of the study, we found that the 91% of the operators considered the implantation technique the main limit of the ABSORB II. Furthermore, 74% of the operators affirmed that the results from the study did not decrease the number of scaffold implanted in their cath-lab. CONCLUSIONS: Absorb II trial did not influence clinical practice among Italian interventional cardiologists mainly due to the overall idea that the co-primary endpoints were not adequate to provide a robust evidence on device clinical safety and also because the lack of experience on device implantation may have influenced the outcomes.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...