Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 14(1): 5444, 2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38443671

RESUMO

With the development of distributed power sources in the distribution network, the algorithm of distribution network reconfiguration is gaining attention from experts and scholars. Its goal is to reduce the power loss during power transmission, so as to reduce the power grid loss during power transmission. And weaken the electric heating effect in the process of electric energy transmission, thus maintaining the safety of the surrounding residents. Due to the wire impedance effect, a lot of electric energy of the circuit is lost to electric heating, which is easy to cause local overheating and lead to fire. This will not only cause power loss, but also endanger the safety of surrounding residents. To address the issue, experiments on distribution grid reconstruction are performed using the enhanced particle swarm-fish swarm algorithm with the Elecgrid self-constructed dataset. Initially, low-voltage distributed power sources in parallel are connected to the circuit, thereby decreasing internal resistance and electrical heat. Then, by controlling the circuit in the system, the double separation relay adjusts the inductance and capacitance of the conductor, thus reducing the reactance length. Additionally, particle swarm particles are mutated to enable them to jump out of the local optimum, and elite fish approach is used to expand the search area. Finally, the proposed fusion algorithm is applied to the self-built data set of Elecgrid and compared with the other three algorithms. The fusion algorithm serves as the standard test system for this comparison. The active power loss of the hybrid algorithm is 63 kW at an operating voltage of 0.74 V. The loss work of the other three algorithms is 74 kW, 97 kW and 109 kW respectively. The mixed algorithm has the lowest loss among the four algorithms. The experiments are repeated for six times, and the linear fitting degrees of the four algorithms are 0.9804, 0.9527, 0.9612 and 0.9503, respectively. The experimental results show that the application of this algorithm can effectively reduce the active loss in the process of distribution network reconfiguration, thus reducing energy consumption; At the same time, it can reduce the electric heating in the process of electric energy transmission, and then prevent the occurrence of fire. There are three main contributions of this study. Firstly, the resistance in the transmission path is reduced by using this algorithm, so that the power transmission efficiency can be analyzed more accurately. Secondly, the new algorithm enriches the power safety maintenance method; Finally, the fire caused by local overheating of the line is reduced by fusion algorithm.

2.
Polymers (Basel) ; 15(23)2023 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-38231898

RESUMO

Electrical breakdown is an important physical phenomenon in power equipment and electronic devices. Recently, the mechanism of AC and DC breakdown has been preliminarily revealed as electrode-dielectric interface breakdown and bulk breakdown, respectively, based on space charge dynamics through numerical calculations. However, the AC breakdown mechanism still lacks enough direct experimental support, which restricts further understanding and the design and development of electrical structures. Here, in this study, LDPE films with various thicknesses ranging from 33 µm to 230 µm were surface modified with ozone for different durations to experimentally investigate DC and AC breakdown mechanism. The results indicate that carbonyl groups (C=O) were introduced onto the film surface, forming shallow surface traps and leading to a decreased average trap depth and an increased trap density. Such a surface oxidation modulated trap distribution led to enhanced space charge injection and bulk electrical field distortion, which decreased DC breakdown strength as the oxidation duration went longer, in all film thicknesses. However, such decreases in breakdown strength occurred only in films below 55 µm under AC stresses, as the enhanced electrical field distortion at the electrode-dielectric interface was more obvious and dominating in thin films. These experimental results further confirm the proposed electrode-dielectric interface breakdown of dielectric films and provide new understandings of space charge modulated electrical breakdown, which fulfills dielectric breakdown theory and benefits the miniaturization of power equipment and electronic devices.

3.
Materials (Basel) ; 15(17)2022 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-36079476

RESUMO

Gradually increasing power transmission voltage requires an improved high-voltage capability of polymeric insulating materials. Surface modification emerges as an easily accessible approach in enhancing breakdown and flashover performances due to the widely acknowledged modification of space-charge behaviors. However, as oxidation and fluorination essentially react within a limited depth of 2 µm underneath polymer surfaces, the nature of such bulk space-charge modulation remains a controversial issue, and further investigation is needed to realize enhancement of insulating performance. In this work, the surface oxidation-dependent space-charge accumulation in LDPE film was found to be dominated by an electrode/polymer interfacial barrier, but not by the generation of bulk charge traps. Through quantitative investigation of space-charge distributions along with induced electric field distortion, the functions of surface oxidation on the interfacial barrier of a typical dielectric polymer, LDPE, is discussed and linked to space-charge behaviors. As the mechanism of surface modification on space-charge behaviors is herein proposed, space-charge accumulation can be effectively modified by selecting an appropriate surface modification method, which consequentially benefits breakdown and flashover performances of polymeric insulating films for high-voltage applications.

4.
Materials (Basel) ; 14(19)2021 Oct 08.
Artigo em Inglês | MEDLINE | ID: mdl-34640298

RESUMO

Power equipment operates under high voltages, inducing space charge accumulation on the surface of key insulating structures, which increases the risk of discharge/breakdown and the possibility of maintenance workers experiencing electric shock accidents. Hence, a visualized non-equipment space charge detection method is of great demand in the power industry. Typical electrochromic phenomenon is based on redox of the material, triggered by a voltage smaller than 5 V with a continuous current in µA~mA level, which is not applicable to high electric fields above 106 V/m with pA~nA operation current in power equipment. Until now, no naked-eye observation technique has been realized for space charge detection to ensure the operation of power systems as well as the safety of maintenance workers. In this work, a viologen/poly(vinylidene fluoride-co-hexafluoropropylene)(P(VDF-HFP)) composite is investigated from gel to insulating bulk configurations to achieve high-voltage electrical-insulating electrochromism. The results show that viologen/P(VDF-HFP) composite bulk can withstand high electric fields at the 107 V/m level, and its electrochromism is triggered by space charges. This electrochromism phenomenon can be visually extended by increasing viologen content towards 5 wt.% and shows a positive response to voltage amplitude and application duration. As viologen/P(VDF-HFP) composite bulk exhibits a typical electrical insulating performance, it could be attached to the surface of insulating structures or clamped between metal and insulating materials as a space charge accumulation indicator in high-voltage power equipment.