Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 226
Filtrar
1.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38591838

RESUMO

AIMS: Recent trial data demonstrate beneficial effects of active rhythm management in patients with atrial fibrillation (AF) and support the concept that a low arrhythmia burden is associated with a low risk of AF-related complications. The aim of this document is to summarize the key outcomes of the 9th AFNET/EHRA Consensus Conference of the Atrial Fibrillation NETwork (AFNET) and the European Heart Rhythm Association (EHRA). METHODS AND RESULTS: Eighty-three international experts met in Münster for 2 days in September 2023. Key findings are as follows: (i) Active rhythm management should be part of the default initial treatment for all suitable patients with AF. (ii) Patients with device-detected AF have a low burden of AF and a low risk of stroke. Anticoagulation prevents some strokes and also increases major but non-lethal bleeding. (iii) More research is needed to improve stroke risk prediction in patients with AF, especially in those with a low AF burden. Biomolecules, genetics, and imaging can support this. (iv) The presence of AF should trigger systematic workup and comprehensive treatment of concomitant cardiovascular conditions. (v) Machine learning algorithms have been used to improve detection or likely development of AF. Cooperation between clinicians and data scientists is needed to leverage the potential of data science applications for patients with AF. CONCLUSIONS: Patients with AF and a low arrhythmia burden have a lower risk of stroke and other cardiovascular events than those with a high arrhythmia burden. Combining active rhythm control, anticoagulation, rate control, and therapy of concomitant cardiovascular conditions can improve the lives of patients with AF.


Assuntos
Fibrilação Atrial , Acidente Vascular Cerebral , Humanos , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Risco , Hemorragia , Anticoagulantes/uso terapêutico
2.
Europace ; 26(2)2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38266130

RESUMO

AIMS: Different disease processes can combine to cause atrial fibrillation (AF). Their contribution to recurrent AF after ablation in patients is not known. Cardiovascular processes associated with recurrent AF after AF ablation were determined by quantifying biomolecules related to inflammation, metabolism, proliferation, fibrosis, shear stress, atrial pressure, and others in the AXAFA biomolecule study. METHODS AND RESULTS: Twelve circulating cardiovascular biomolecules (ANGPT2, BMP10, CA125, hsCRP, ESM1, FABP3, FGF23, GDF15, IGFBP7, IL6, NT-proBNP, and hsTnT) were quantified in plasma samples obtained prior to a first AF ablation using high-throughput, high-precision assays. Cox regression was used to identify biomolecules associated with recurrent AF during the first 3 months after AF ablation. In 433 patients (64 years [58, 70]; 33% women), baseline concentrations of ANGPT2, BMP10, hsCRP, FGF23, FABP3, GDF15, and NT-proBNP were elevated in patients with recurrent AF (120/433; 28%). After adjustment for 11 clinical features and randomized treatment, elevated NT-proBNP [hazard ratio (HR) 1.58, 95% confidence interval (1.29, 1.94)], ANGPT2 [HR 1.37, (1.12, 1.67)], and BMP10 [HR 1.24 (1.02, 1.51)] remained associated with recurrent AF. Concentrations of ANGPT2, BMP10, and NT-proBNP decreased in patients who remained arrhythmia free, but not in patients with recurrent AF, highlighting their connection to AF. The other eight biomarkers showed unchanged concentrations. CONCLUSION: Elevated concentrations of ANGPT2, BMP10, and NT-proBNP are associated with recurrent AF after a first AF ablation, suggesting that processes linked to disturbed cardiomyocyte metabolism, altered atrial shear stress, and increased load contribute to AF after AF ablation in patients.


Assuntos
Fibrilação Atrial , Humanos , Feminino , Masculino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/complicações , Proteína C-Reativa , Átrios do Coração , Peptídeo Natriurético Encefálico , Biomarcadores , Modelos de Riscos Proporcionais , Fragmentos de Peptídeos , Proteínas Morfogenéticas Ósseas
3.
Europace ; 26(2)2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38289720

RESUMO

Cardiac electrophysiology is an evolving field that relies heavily on costly device- and catheter-based technologies. An increasing number of patients with heart rhythm disorders are becoming eligible for cardiac interventions, not least due to the rising prevalence of atrial fibrillation and increased longevity in the population. Meanwhile, the expansive costs of healthcare face finite societal resources, and a cost-conscious approach to new technologies is critical. Cost-effectiveness analyses support rational decision-making in healthcare by evaluating the ratio of healthcare costs to health benefits for competing therapies. They may, however, be subject to significant uncertainty and bias. This paper aims to introduce the basic concepts, framework, and limitations of cost-effectiveness analyses to clinicians including recent examples from clinical electrophysiology and device therapy.


Assuntos
Fibrilação Atrial , Técnicas Eletrofisiológicas Cardíacas , Humanos , Análise Custo-Benefício , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/terapia , Custos de Cuidados de Saúde , Resultado do Tratamento , Anos de Vida Ajustados por Qualidade de Vida
4.
Europace ; 25(12)2023 12 06.
Artigo em Inglês | MEDLINE | ID: mdl-38055845

RESUMO

AIMS: Modern clinical management of patients with an implantable cardioverter defibrillator (ICD) largely consists of remote device monitoring, although a subset is at risk of mental health issues post-implantation. We compared a 12-month web-based intervention consisting of goal setting, monitoring of patients' mental health-with a psychological intervention if needed-psychoeducational support from a nurse, and an online patient forum, with usual care on participants' device acceptance 12 months after implantation. METHODS AND RESULTS: This national, multi-site, two-arm, non-blinded, randomized, controlled, superiority trial enrolled 478 first-time ICD recipients from all 6 implantation centres in Denmark. The primary endpoint was patient device acceptance measured by the Florida Patient Acceptance Survey (FPAS; general score range = 0-100, with higher scores indicating higher device acceptance) 12 months after implantation. Secondary endpoints included symptoms of depression and anxiety. The primary endpoint of device acceptance was not different between groups at 12 months [B = -2.67, 95% confidence interval (CI) (-5.62, 0.29), P = 0.08]. Furthermore, the secondary endpoint analyses showed no significant treatment effect on either depressive [B = -0.49, 95% CI (-1.19; 0.21), P = 0.17] or anxiety symptoms [B = -0.39, 95% CI (-0.96; 0.18), P = 0.18]. CONCLUSION: The web-based intervention as supplement to usual care did not improve patient device acceptance nor symptoms of anxiety and depression compared with usual care. This specific web-based intervention thus cannot be recommended as a standardized intervention in ICD patients.


Assuntos
Desfibriladores Implantáveis , Qualidade de Vida , Humanos , Ansiedade/prevenção & controle , Ansiedade/psicologia , Atenção à Saúde , Internet , Qualidade de Vida/psicologia , Inquéritos e Questionários
6.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37695316

RESUMO

AIMS: Several studies have evaluated the use of electrically- or imaging-guided left ventricular (LV) lead placement in cardiac resynchronization therapy (CRT) recipients. We aimed to assess evidence for a guided strategy that targets LV lead position to the site of latest LV activation. METHODS AND RESULTS: A systematic review and meta-analysis was performed for randomized controlled trials (RCTs) until March 2023 that evaluated electrically- or imaging-guided LV lead positioning on clinical and echocardiographic outcomes. The primary endpoint was a composite of all-cause mortality and heart failure hospitalization, and secondary endpoints were quality of life, 6-min walk test (6MWT), QRS duration, LV end-systolic volume, and LV ejection fraction. We included eight RCTs that comprised 1323 patients. Six RCTs compared guided strategy (n = 638) to routine (n = 468), and two RCTs compared different guiding strategies head-to-head: electrically- (n = 111) vs. imaging-guided (n = 106). Compared to routine, a guided strategy did not significantly reduce the risk of the primary endpoint after 12-24 (RR 0.83, 95% CI 0.52-1.33) months. A guided strategy was associated with slight improvement in 6MWT distance after 6 months of follow-up of absolute 18 (95% CI 6-30) m between groups, but not in remaining secondary endpoints. None of the secondary endpoints differed between the guided strategies. CONCLUSION: In this study, a CRT implantation strategy that targets the latest LV activation did not improve survival or reduce heart failure hospitalizations.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Terapia de Ressincronização Cardíaca/efeitos adversos , Ecocardiografia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Ventrículos do Coração/diagnóstico por imagem , Hospitalização
7.
Artigo em Inglês | MEDLINE | ID: mdl-37682525

RESUMO

BACKGROUND AND AIM: There are a paucity of studies investigating workforce affiliation in connection with first-time ICD-implantation. This study explored workforce affiliation and risk markers associated with not returning to work in patients with ICDs. METHODS: Using the nationwide Danish registers, patients with a first-time ICD-implantation between 2007-2017 and of working age (30-65 years) were identified. Descriptive statistic and logistic regression models were used to describe workforce affiliation and to estimate risk markers associated with not returning to work, respectively. All analyses were stratified by indication for implantation (primary and secondary prevention). RESULTS: Of the 4,659 ICD-patients of working age, 3,300 patients (71%) were members of the workforce (employed, on sick leave or unemployed) (primary: 1428 (43%); secondary:1872 (57%)). At baseline, 842 primary and 1477 secondary prevention ICD-patients were employed. Of those employed at baseline, 81% primary and 75% secondary prevention ICD-patients returned to work within one-year, whereof more than 80% remained employed the following year. Among patients receiving sick leave benefits at baseline, 25% were employed after one-year. Risk markers of not returning to work were 'younger age' in primary prevention ICD-patients, while 'female sex', 'LVEF ≤40', 'lower income' and '≥3 comorbidities' were risk markers in secondary prevention ICD-patients. Lower educational level was a risk marker in both patient groups. CONCLUSIONS: High return-to-work proportions following ICD-implantation, with a subsequent high level of employment maintenance were found. Several significant risk markers of not returning to work were identified including 'lower educational level', that posed a risk in both patient groups.Trial registration number: Capital Region of Denmark, P-2019-051.

8.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37622591

RESUMO

This reviews the transition of remote monitoring of patients with cardiac electronic implantable devices from curiosity to standard of care. This has been delivered by technology evolution from patient-activated remote interrogations at appointed intervals to continuous monitoring that automatically flags clinically actionable information to the clinic for review. This model has facilitated follow-up and received professional society recommendations. Additionally, continuous monitoring has provided a new level of granularity of diagnostic data enabling extension of patient management from device to disease management. This ushers in an era of digital medicine with wider applications in cardiovascular medicine.


Assuntos
Fármacos Cardiovasculares , Humanos , Eletrônica , Coração , Tecnologia , Gerenciamento Clínico
9.
Eur Heart J ; 44(40): 4246-4255, 2023 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-37638973

RESUMO

BACKGROUND AND AIMS: High percentages of atrial pacing have been associated with an increased risk of atrial fibrillation. This study is aimed at evaluating whether atrial pacing minimization in patients with sinus node dysfunction reduces the incidence of atrial fibrillation. METHODS: In a nationwide, randomized controlled trial, 540 patients with sinus node dysfunction and an indication for first pacemaker implantation were assigned to pacing programmed to a base rate of 60 bpm and rate-adaptive pacing (DDDR-60) or pacing programmed to a base rate of 40 bpm without rate-adaptive pacing (DDD-40). Patients were followed on remote monitoring for 2 years. The primary endpoint was time to first episode of atrial fibrillation longer than 6 min. Secondary endpoints included longer episodes of atrial fibrillation, and the safety endpoint comprised a composite of syncope or presyncope. RESULTS: The median percentage of atrial pacing was 1% in patients assigned to DDD-40 and 49% in patients assigned to DDDR-60. The primary endpoint occurred in 124 patients (46%) in each treatment group (hazard ratio [HR] 0.97, 95% confidence interval [CI] 0.76-1.25, P = .83). There were no between-group differences in atrial fibrillation exceeding 6 or 24 h, persistent atrial fibrillation, or cardioversions for atrial fibrillation. The incidence of syncope or presyncope was higher in patients assigned to DDD-40 (HR 1.71, 95% CI 1.13-2.59, P = .01). CONCLUSIONS: Atrial pacing minimization in patients with sinus node dysfunction does not reduce the incidence of atrial fibrillation. Programming a base rate of 40 bpm without rate-adaptive pacing is associated with an increased risk of syncope or presyncope.

10.
Europace ; 25(6)2023 06 02.
Artigo em Inglês | MEDLINE | ID: mdl-37335977

RESUMO

AIMS: To date, potential differences in outcomes for immigrants and non-immigrants with a cardiac resynchronization therapy (CRT), in a European setting, remain underutilized and unknown. Hence, we examined the efficacy of CRT measured by heart failure (HF)-related hospitalizations and all-cause mortality among immigrants and non-immigrants. METHODS AND RESULTS: All immigrants and non-immigrants who underwent first-time CRT implantation in Denmark (2000-2017) were identified from nationwide registries and followed for up to 5 years. Differences in HF related hospitalizations and all-cause mortality were evaluated by Cox regression analyses. From 2000 to 2017, 369 of 10 741 (3.4%) immigrants compared with 7855 of 223 509 (3.5%) non-immigrants with a HF diagnosis underwent CRT implantation. The origins of the immigrants were Europe (61.2%), Middle East (20.1%), Asia-Pacific (11.9%), Africa (3.5%), and America (3.3%). We found similar high uptake of HF guideline-directed pharmacotherapy before and after CRT and a consistent reduction in HF-related hospitalizations the year before vs. the year after CRT (61% vs. 39% for immigrants and 57% vs. 35% for non-immigrants). No overall difference in 5-year mortality among immigrants and non-immigrants was seen after CRT [24.1% and 25.8%, respectively, P-value = 0.50, hazard ratio (HR) = 1.2, 95% confidence interval (CI): 0.8-1.7]. However, immigrants of Middle Eastern origin had a higher mortality rate (HR = 2.2, 95% CI: 1.2-4.1) compared with non-immigrants. Cardiovascular causes were responsible for the majority of deaths irrespective of immigration status (56.7% and 63.9%, respectively). CONCLUSION: No overall differences in efficacy of CRT in improving outcomes between immigrants and non-immigrants were identified. Although numbers were low, a higher mortality rate among immigrants of Middle Eastern origin was identified compared with non-immigrants.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Insuficiência Cardíaca , Humanos , Terapia de Ressincronização Cardíaca/métodos , Resultado do Tratamento , Dispositivos de Terapia de Ressincronização Cardíaca/efeitos adversos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/etiologia , Modelos de Riscos Proporcionais , Desfibriladores Implantáveis/efeitos adversos
11.
Europace ; 25(6)2023 06 02.
Artigo em Inglês | MEDLINE | ID: mdl-37345858

RESUMO

AIMS: Use of an absorbable antibacterial envelope during implantation prevents cardiac implantable electronic device infections in patients with a moderate-to-high infection risk. Previous studies demonstrated that an envelope is cost-effective in high-risk patients within German, Italian, and English healthcare systems, but these analyses were based on limited data and may not be generalizable to other healthcare settings. METHODS AND RESULTS: A previously published decision-tree-based cost-effectiveness model was used to compare the costs per quality-adjusted life year (QALY) associated with adjunctive use of an antibacterial envelope for infection prevention compared to standard-of-care intravenous antibiotics. The model was adapted using data from a Danish observational two-centre cohort study that investigated infection-risk patients undergoing cardiac resynchronization therapy (CRT) reoperations with and without an antibacterial envelope (n = 1943). We assumed a cost-effectiveness threshold of €34 125/QALY gained, based on the upper threshold used by the National Institute for Health and Care Excellence (£30 000). An antibacterial envelope was associated with an incremental cost-effectiveness ratio (ICER) of €12 022 per QALY in patients undergoing CRT reoperations, thus indicating that the envelope is cost-effective when compared with standard of care. A separate analysis stratified by device type showed ICERS of €6227 (CRT defibrillator) and €29 177 (CRT pacemaker) per QALY gained. CONCLUSIONS: Cost-effectiveness ratios were favourable for patients undergoing CRT reoperations in the Danish healthcare system, and thus are in line with previous studies. Results from this study can contribute to making the technology available to Danish patients and align preventive efforts in the pacemaker and ICD area.


Assuntos
Terapia de Ressincronização Cardíaca , Humanos , Reoperação , Terapia de Ressincronização Cardíaca/efeitos adversos , Análise Custo-Benefício , Estudos de Coortes , Antibacterianos/uso terapêutico , Dinamarca
12.
Am Heart J ; 263: 112-122, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37220821

RESUMO

BACKGROUND: Cardiac resynchronization therapy (CRT) improves symptoms, health-related quality of life and long-term survival in patients with systolic heart failure (HF) and shortens QRS duration. However, up to one third of patients attain no measurable clinical benefit from CRT. An important determinant of clinical response is optimal choice in left ventricular (LV) pacing site. Observational data have shown that achieving an LV lead position at a site of late electrical activation is associated with better clinical and echocardiographic outcomes compared to standard placement, but mapping-guided LV lead placement towards the site of latest electrical activation has never been investigated in a randomized controlled trial (RCT). The purpose of this study was to evaluate the effect of targeted positioning of the LV lead towards the latest electrically activated area. We hypothesize that this strategy is superior to standard LV lead placement. METHODS: The DANISH-CRT trial is a national, double-blinded RCT (ClinicalTrials.gov NCT03280862). A total of 1,000 patients referred for a de novo CRT implantation or an upgrade to CRT from right ventricular pacing will be randomized 1:1 to receive conventional LV lead positioning preferably in a nonapical posterolateral branch of the coronary sinus (CS) (control group) or targeted positioning of the LV lead to the CS branch with the latest local electrical LV activation (intervention group). In the intervention group, late activation will be determined using electrical mapping of the CS. The primary endpoint is a composite of death and nonplanned HF hospitalization. Patients are followed for a minimum of 2 years and until 264 primary endpoints occurred. Analyses will be conducted according to the intention-to-treat principle. Enrollment for this trial began in March 2018, and per April 2023, a total of 823 patients have been included. Enrollment is expected to be complete by mid-2024. CONCLUSIONS: The DANISH-CRT trial will clarify whether mapping-guided positioning of the LV lead according to the latest local electrical activation in the CS is beneficial for patients in terms of reducing the composite endpoint of death or nonplanned hospitalization for heart failure. Results from this trial are expected to impact future guidelines on CRT. GOV IDENTIFIER: NCT03280862.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Terapia de Ressincronização Cardíaca/métodos , Dispositivos de Terapia de Ressincronização Cardíaca , Incidência , Resultado do Tratamento , Ventrículos do Coração/diagnóstico por imagem , Hospitalização
13.
Heart Rhythm ; 20(9): 1227-1235, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-36965653

RESUMO

BACKGROUND: External cardioversion (ECV) is an essential part of rhythm control of atrial fibrillation and flutter in patients with and without cardiovascular implantable electronic devices (CIEDs). Long-term follow-up data on ECV-related CIED dysfunctions are limited. OBJECTIVE: The purpose of this study was to investigate the risk of CIED reintervention following ECV in a nationwide cohort. METHODS: We identified CIED implants and surgical reinterventions from 2005 to 2021 in the Danish Pacemaker and ICD Register. We included CIED patients undergoing ECV from 2010 to 2019 from the Danish National Patient Registry. For each ECV-exposed generator, 5 matched generators without ECV were identified, and for each ECV-exposed lead, 3 matched leads were identified. The primary endpoints were generator replacement and lead reintervention. RESULTS: We compared 2582 ECV-exposed patients with 12,910 matched patients with a pacemaker (47%), implantable cardioverter-defibrillator (ICD) (29%), cardiac resynchronization therapy-pacemaker (6%), or cardiac resynchronization therapy-defibrillator (18%). During 2 years of follow-up, 210 ECV-exposed generators (8.1%) vs 670 matched generators (5.2%) underwent replacements, and 247 ECV-exposed leads (5.6%) vs 306 matched leads (2.3%) underwent reintervention. Unadjusted hazard ratios were 1.61 (95% confidence interval [CI] 1.37-1.91; P <.001) for generator replacement and 2.39 (95% CI 2.01-2.85; P <.001) for lead reintervention. One-year relative risks were 1.73 (95% CI 1.41-2.12; P <.001) for generator replacement and 2.85 (95% CI 2.32-3.51; P <.001) for lead reintervention, and 2-year relative risks were 1.39 (95% CI 1.19-1.63; P <.001) and 2.18 (95% CI 1.84-2.57; P <.001), respectively. CONCLUSION: ECV in patients with a CIED is associated with a higher risk of generator replacement and lead reintervention. The risks of reinterventions were more pronounced within the first year after cardioversion.


Assuntos
Fibrilação Atrial , Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Cardioversão Elétrica/efeitos adversos , Fibrilação Atrial/terapia , Estudos de Coortes , Desfibriladores Implantáveis/efeitos adversos , Marca-Passo Artificial/efeitos adversos , Estudos Retrospectivos
14.
J Am Heart Assoc ; 12(7): e028424, 2023 04 04.
Artigo em Inglês | MEDLINE | ID: mdl-36942759

RESUMO

Background Patients with Brugada syndrome (BrS) are recommended to avoid drugs that may increase their risk of arrhythmic events. We examined treatment with such drugs in patients with BrS after their diagnosis. Methods and Results All Danish patients diagnosed with BrS (2006-2018) with >12 months of follow-up were identified from nationwide registries. Nonrecommended BrS drugs were grouped into drugs to "avoid" or "preferably avoid" according to http://www.brugadadrugs.org. Cox proportional hazards analyses were performed to identify factors associated with any nonrecommended BrS drug use, and logistic regression analyses were performed to examine associated risk of appropriate implantable cardioverter defibrillator therapy, mortality, and a combined end point indicating an arrhythmic event of delayed implantable cardioverter defibrillator implantation, appropriate implantable cardioverter defibrillator therapy, and mortality. During a median follow-up of 6.8 years, 93/270 (34.4%) patients with BrS (70.4% male, median age at diagnosis 46.1 years [interquartile range, 32.6-57.4]) were treated with ≥1 nonrecommended BrS drugs. No difference in any nonrecommended BrS drug use was identified comparing time before BrS diagnosis (12.6%) with each of the 5 years following BrS diagnosis (P>0.05). Factors associated with any nonrecommended BrS drug use after diagnosis were female sex (hazard ratio [HR]) 1.83 [95% CI, 1.15-2.90]), psychiatric disease (HR, 3.63 [1.89-6.99]), and prior use of any nonrecommended BrS drug (HR, 4.76 [2.45-9.25]). No significant association between any nonrecommended BrS drug use and implantable cardioverter defibrillator therapy (n=20/97, odds ratio [OR], 0.7 [0.2-2.4]), mortality (n=10/270, OR, 3.4 [0.7-19.6]), or the combined end point (n=38/270, OR, 1.7 [0.8-3.7]) was identified. Conclusions One in 3 patients with BrS were treated with a nonrecommended BrS drug after BrS diagnosis, and a BrS diagnosis did not change prescription patterns. More awareness of nonrecommended drug use among patients with BrS is needed.


Assuntos
Síndrome de Brugada , Desfibriladores Implantáveis , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/terapia , Síndrome de Brugada/complicações , Estudos de Coortes , Eletrocardiografia/métodos , Dinamarca/epidemiologia , Morte Súbita Cardíaca
15.
Heart ; 109(17): 1286-1293, 2023 08 11.
Artigo em Inglês | MEDLINE | ID: mdl-36948572

RESUMO

OBJECTIVE: Atrial fibrillation (AF) is associated with adverse events including conduction disturbances, ventricular arrhythmias and sudden death. The aim of this study was to examine brady- and tachyarrhythmias using continuous rhythm monitoring in patients with paroxysmal self-terminating AF (PAF). METHODS: In this multicentre observational substudy to the Reappraisal of Atrial Fibrillation: interaction between hyperCoagulability, Electrical remodelling and Vascular destabilisation in the progression of AF (RACE V), we included 392 patients with PAF and at least 2 years of continuous rhythm monitoring. All patients received an implantable loop recorder, and all detected episodes of tachycardia ≥182 beats per minute (BPM), bradycardia ≤30 BPM or pauses ≥5 s were adjudicated by three physicians. RESULTS: Over 1272 patient-years of continuous rhythm monitoring, we adjudicated 1940 episodes in 175 patients (45%): 106 (27%) patients experienced rapid AF or atrial flutter (AFL), pauses ≥5 s or bradycardias ≤30 BPM occurred in 47 (12%) patients and in 22 (6%) patients, we observed both episode types. No sustained ventricular tachycardias occurred. In the multivariable analysis, age >70 years (HR 2.3, 95% CI 1.4 to 3.9), longer PR interval (HR 1.9, 1.1-3.1), CHA2DS2-VASc score ≥2 (HR 2.2, 1.1-4.5) and treatment with verapamil or diltiazem (HR 0.4, 0.2-1.0) were significantly associated with bradyarrhythmia episodes. Age >70 years was associated with lower rates of tachyarrhythmias. CONCLUSIONS: In a cohort exclusive to patients with PAF, almost half experienced severe bradyarrhythmias or AF/AFL with rapid ventricular rates. Our data highlight a higher than anticipated bradyarrhythmia risk in PAF. TRIAL REGISTRATION NUMBER: NCT02726698.


Assuntos
Fibrilação Atrial , Flutter Atrial , Taquicardia Ventricular , Idoso , Humanos , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Flutter Atrial/complicações , Bradicardia/complicações , Ventrículos do Coração , Taquicardia Ventricular/complicações
16.
J Interv Card Electrophysiol ; 66(8): 1849-1857, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36753028

RESUMO

BACKGROUND: His bundle pacing (HBP) is a novel treatment with limited knowledge on long-term outcome. We aimed to assess long-term safety and effectiveness of HBP in patients with atrioventricular block treated with HBP and a back-up right ventricular pacing (RVP) lead. METHODS: We included 38 patients from a completed single-center, randomized controlled cross-over trial designed to compare left ventricular (LV) function after 12 months of HBP vs. RVP conducted between September 2007 and August 2011. Lead performance beyond the 2-year study period was assessed based on a retrospective review of capture thresholds, sensing, impedance, energy consumption, and rate of HBP interruption. RESULTS: Patients were followed for a mean of 7 ± 4 years. Both at baseline and during follow-up, HBP leads displayed significantly higher capture thresholds than RVP leads (P < 0.001), multifold higher energy consumption (P < 0.001), and lower sensing amplitudes (P < 0.001). During follow-up, 17 (53%) HBP leads were deactivated or abandoned. The principal cause for HBP interruption was high pacing thresholds in patients with preserved LVEF during RVP. Device longevity was shorter than that of contemporary cohorts treated with dual-chamber pacing or CRT, and time to first device exchange was 6.8 ± 1.5 years. No lead dislodgements occurred, but four patients (10%) developed device-related infections requiring device extraction. CONCLUSION: HBP was interrupted in > 50% of patients during long-term follow-up. The principal cause was unacceptably high capture thresholds and no significant difference in LV function with HBP compared with RVP. Device longevity was shorter, and infection rates were higher than anticipated.

17.
Am J Med ; 136(5): 458-465.e3, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36822258

RESUMO

OBJECTIVE: Our purpose was to examine the association between beta-blocker dose and mortality following acute myocardial infarction. METHODS: This nationwide cohort study enrolled all patients admitted for first-time acute myocardial infarction in Denmark between July 1, 2004 and December 31, 2014, using the Danish National Patient Registry. Patients alive 15 days after admission were followed until death, emigration, or December 31, 2014. Patients were categorized according to daily beta-blocker consumption (0%, >0%-12.5%, >12.5%-25%, >25%-50%, >50%-100%, or >100% of the currently recommended target dose) based on prescriptions registered in the Danish National Database of Reimbursed Prescriptions. Doses were continuously updated during follow-up. Mortality rate ratios (MRRs) were computed and adjusted for confounders using Cox proportional hazard regression. RESULTS: Among 65,125 patients followed, any beta-blocker dose was associated with significant mortality reduction compared with no treatment (adjusted MRR ≤ 0.92 [95% confidence interval {CI}: 0.86-0.98]). The largest reduction was observed within the first year for beta-blocker doses >25%-50% (adjusted MRR = 0.55 [95% CI: 0.50-0.60]). After 1 year, doses >50%-100% were associated with the largest mortality reduction (adjusted MRR = 0.58 [95% CI: 0.50-0.67]), but it did not differ significantly from that associated with doses >25%-50% (adjusted MRR = 0.68 [95% CI: 0.61-0.77]). CONCLUSIONS: Any beta-blocker dose was associated with significant mortality reduction following acute myocardial infarction compared with no treatment. Doses >25%-50% of the currently recommended target dose were associated with maximal mortality reduction within the first year after acute myocardial infarction, suggesting that higher doses are unnecessary.


Assuntos
Infarto do Miocárdio , Humanos , Seguimentos , Estudos de Coortes , Antagonistas Adrenérgicos beta/uso terapêutico , Sistema de Registros
18.
Gen Hosp Psychiatry ; 80: 54-61, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36638700

RESUMO

OBJECTIVE: Identify implantable cardioverter defibrillator (ICD) patients at risk of distress (i.e., depression, anxiety, and ICD concerns) and associated risk factors. METHOD: First-time ICD patients (n = 1503) from the Danish national DEFIB-WOMEN study completed questionnaires at baseline, 3, 6, 12 and 24 months. RESULTS: Of patients with low scores on distress, only 4%-7.2% experienced an increase in distress during 24 months of follow-up (FU), while 30.5%-52.5% with increased levels were likely to maintain increased levels at FU. Higher education, higher age, female sex, and good physical functioning at baseline were associated with less depression, anxiety and ICD concerns at FU. Previous psychological problems, smoking, Type D personality, NYHA class III-IV - all assessed at baseline - and shocks during FU were associated with depression, anxiety and ICD concerns. CONCLUSIONS: Generally, patients' psychological health improved, but patients with increased baseline scores were more likely to have increased scores at FU. We need to be vigilant if patients report elevated distress, particularly if they have depression at baseline, as depression seems more persistent. Given the impact of depression on health-related quality of life and prognosis, they should be screened and monitored closely.


Assuntos
Desfibriladores Implantáveis , Humanos , Feminino , Desfibriladores Implantáveis/psicologia , Qualidade de Vida/psicologia , Depressão/epidemiologia , Depressão/terapia , Depressão/etiologia , Seguimentos , Ansiedade/epidemiologia , Ansiedade/psicologia , Dinamarca/epidemiologia
19.
J Psychosom Res ; 164: 111072, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36459826

RESUMO

OBJECTIVE: The implantable cardioverter defibrillator (ICD) is used to treat malignant ventricular arrhythmias. Since 33% of patients experience ICD-related concerns, we examined sex differences in ICD concerns and correlates of ICD concerns during 24 months of follow-up after implantation of an ICD. METHODS: Patients from the DEFIB-WOMEN study (n = 1515; 81.6% male patients) completed questionnaires on ICD concerns, anxiety, depression, and Type D personality at five measure points (baseline, 3-, 6-, 12- and 24-months post-implantation). RESULTS: Male patients scored on average 7.0 (6.8) points on ICD concerns at the time of implantation and female patients scored on average 10.5 (8.2) points. We found statistically significant sex differences in ICD concerns at all measurement points, with female patients scoring 2.77 points (8.7% of the maximum score of 32) higher than male patients. ICD concerns decreased in both sexes the first 6 months and then levelled out. For both sexes, ICD concerns at baseline were significantly correlated with ICD concerns at 24-months follow-up. Anxiety at baseline was correlated with ICD concerns in female patients, while depression at baseline and at least one experienced shock correlated with ICD concerns in male patients. CONCLUSION: Female patients reported more ICD concerns at all measurement points compared to male patients, but for both sexes ICD concerns decreased in the first 6 months. ICD shock, anxiety, depression, and ICD concerns at baseline were correlates of ICD concerns at 24-months follow-up.


Assuntos
Desfibriladores Implantáveis , Feminino , Humanos , Masculino , Ansiedade/epidemiologia , Desfibriladores Implantáveis/psicologia , Dinamarca/epidemiologia , Distribuição por Sexo , Depressão/epidemiologia , Personalidade Tipo D , Seguimentos , Fatores de Risco , Inquéritos e Questionários
20.
J Interv Card Electrophysiol ; 66(4): 897-904, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35499775

RESUMO

PURPOSE: Cardiac surgery in patients with cardiac implantable electronic devices (CIEDs) has been associated with a higher risk of infective endocarditis, but how it influences risk of CIED-specific infections is not known. Our aim was to examine risk of systemic CIED infections after cardiac surgery in patients with CIEDs. METHODS: Based on data obtained from Danish administrative registries and the Danish Pacemaker and ICD Register, we conducted a case-control study nested within a nationwide cohort of patients who underwent a de novo CIED implantation in Denmark between 1998 and 2017. We defined cases as incident systemic CIED infections resulting in device system extraction. Controls were sampled 1:100 on time, age, sex and device type using risk set sampling. Exposure was defined as coronary artery bypass graft, or cardiac heart valve replacement or repair surgery. RESULTS: From a study cohort comprising 67,621 patients, we identified 170 cases and 16,788 controls. In the minimally adjusted model, the incidence rate ratio (IRR) for systemic CIED infection was 6.4 (95% confidence interval (CI) 3.8-10.7) with cardiac surgery, and after additional confounder adjustment, 5.4 (95% CI 3.2-9.2). IRRs were higher with restriction to heart valve replacement surgery (adjusted IRR 7.5, 95% CI 4.0-16.6), and when limiting our exposure time window to one year (adjusted IRR 10.1, 95% CI 4.5-22.3). CONCLUSION: Cardiac surgery in patients with de novo CIEDs was associated with a high risk of systemic CIED infections. Highest risk was observed after heart valve replacement surgery and within the first year of surgery.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Desfibriladores Implantáveis , Marca-Passo Artificial , Infecções Relacionadas à Prótese , Humanos , Estudos de Casos e Controles , Desfibriladores Implantáveis/efeitos adversos , Fatores de Risco , Marca-Passo Artificial/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Estudos Retrospectivos , Infecções Relacionadas à Prótese/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...