1.
Artigo em Inglês | MEDLINE | ID: mdl-38606037

RESUMO

Biomaterial scaffolds in tissue engineering facilitate tissue regeneration and integration with the host. Poor healing outcomes arise from lack of cell and tissue infiltration, and ill-fitting interfaces between matrices or grafts, resulting in fibrous tissue formation, inflammation, and resorption. Existing tissue engineering scaffolds struggle to recover from deformation to fit irregularly shaped defects encountered in clinical settings without compromising their mechanical properties and favorable internal architecture. This study introduces a synthetic biomaterial scaffold composed of high molecular weight poly (L-lactic acid) (PLLA) and an interpenetrating network of poly (ε-caprolactone) (PCL), in a composition aiming to address the need for conformal fitting synthetic matrices which retain and recover their advantageous morphologies. The scaffold, known as thermosensitive memorized microstructure (TS-MMS), forms nanofibrous materials with memorized microstructures capable of recovery after deformation, including macropores and nanofibers. TS-MMS nanofibers, with 50-500 nm diameters, are formed via thermally induced phase separation (TIPS) of PLLA after in situ polymerization of PCL-diacrylate. A critical partial-melting temperature of TS-MMS at 52°C enables bulk deformation above this temperature, while retaining the nanofibrous and macroporous structures upon cooling to 37°C. Incorporation of drug-loaded poly (lactide-co-glycolide) (PLGA) nanoparticles directly into TS-MMS nanofibers during fabrication allows sustained release of a model drug for up to 40 days. Subcutaneous implantation in vivo using LysM-Cre;td-Tomato; Col1eGFP mice demonstrates successful cellularization and integration of deformed/recovered TS-MMS materials, surpassing the limitations of deformed PLLA scaffolds, to facilitate cell and vasculature infiltration requisite for successful bone regeneration. Additionally we demonstrated a method for embedding controlled release vehicles directly into the scaffold nanofibers; controlled release of simvastatin enhances vascularization and tissue maturation. TS-MMS scaffolds offer promising improvements in clinical handling and performance compared to existing biomaterial scaffolds.

2.
RSC Chem Biol ; 3(6): 748-764, 2022 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-35755193

RESUMO

Acidic pH is critical to the function of the gastrointestinal system, bone-resorbing osteoclasts, and the endolysosomal compartment of nearly every cell in the body. Non-invasive, real-time fluorescence imaging of acidic microenvironments represents a powerful tool for understanding normal cellular biology, defining mechanisms of disease, and monitoring for therapeutic response. While commercially available pH-sensitive fluorescent probes exist, several limitations hinder their widespread use and potential for biologic application. To address this need, we developed a novel library of pH-sensitive probes based on the highly photostable and water-soluble fluorescent molecule, Rhodamine 6G. We demonstrate versatility in terms of both pH sensitivity (i.e., pK a) and chemical functionality, allowing conjugation to small molecules, proteins, nanoparticles, and regenerative biomaterial scaffold matrices. Furthermore, we show preserved pH-sensitive fluorescence following a variety of forms of covalent functionalization and demonstrate three potential applications, both in vitro and in vivo, for intracellular and extracellular pH sensing. Finally, we develop a computation approach for predicting the pH sensitivity of R6G derivatives, which could be used to expand our library and generate probes with novel properties.

4.
J Control Release ; 324: 679-694, 2020 08 10.
Artigo em Inglês | MEDLINE | ID: mdl-32534011

RESUMO

Mineralized enamel and dentin provide protection to the dental pulp, which is vital tissue rich with cells, vasculature, and nerves in the inner tooth. Dental caries left untreated threaten exposure of the dental pulp, providing facile access for bacteria to cause severe infection both in the pulp and systemically. Dental materials which stimulate the formation of a protective dentin bridge after insult are necessary to seal the pulp chamber in an effort to maintain natural dentition and prevent pulpal infection. Dental materials to date including calcium hydroxide paste, mineral trioxide aggregate, and glass ionomer resin, are used with mixed results. Herein we exploited the cell-cell communicative properties of exosomes, extracellular vesicles derived from both mineralizing primary human dental pulp stem cells (hDPSCs) and an immortalized murine odontoblast cell line (MDPC-23), to catalyze the formation of a reactionary dentin bridge by recruiting endogenous stem cells of the dental pulp, through an easy-to-handle delivery vehicle which allows for their therapeutic controlled delivery at the pulp interface. Exosomes derived from both hDPSCs and MDPCs upregulated odontogenic gene expression and increased mineralization in vitro. We designed an amphiphilic synthetic polymeric vehicle from a triblock copolymer which encapsulates exosomes by polymeric self-assembly and maintains their biologic integrity throughout release up to 8-12 weeks. The controlled release of odontogenic exosomes resulted in a reparative dentin bridge formation, superior to glass-ionomer cement alone in vivo, in a rat molar pulpotomy model after six weeks. We have developed a platform for the encapsulation and controlled, tunable release of cell-derived exosomes, which maintains their advantageous physiologic properties reflective of the donor cells. This platform is used to modulate downstream recipient cells towards a designed dentinogenic trajectory in vitro and in vivo. Additionally, we have demonstrated the utility of an immortalized cell line to produce a high yield of exosomes with cross-species efficacy.


Assuntos
Cárie Dentária , Exossomos , Animais , Biomimética , Preparações de Ação Retardada , Cárie Dentária/terapia , Capeamento da Polpa Dentária , Dentinogênese , Combinação de Medicamentos , Camundongos , Óxidos , Ratos
5.
J Neurosurg ; 134(6): 1861-1870, 2020 06 19.
Artigo em Inglês | MEDLINE | ID: mdl-32559747

RESUMO

OBJECTIVE: The literature suggests that blood-brain barrier disruption (BBBD) plays a significant role in the development of neurological events in patients with diffusion-weighted imaging (DWI) that is negative for lesions. In this prospective, single-center cohort study, the authors compared the imaging characteristics of patients suffering transient neurological events (TNEs) with those in patients suffering permanent neurological events (PNEs) after having undergone elective embolization of unruptured intracranial aneurysms. METHODS: This prospective cohort study was conducted between July 2016 and June 2019. Inclusion criteria were adults undergoing elective neuroendovascular procedures and the absence of contraindications to MRI. All subjects underwent brain MRI including postcontrast FLAIR (pcFLAIR) sequences for evaluation of BBBD within 24 hours postprocedure. RESULTS: In total, 128 patients harboring 133 unruptured aneurysms were enrolled, 109 of whom (85.2%) showed some degree of BBBD on pcFLAIR MRI and 50 of whom (39.1%) suffered an ischemic insult per DWI. In total, 23 patients (18%) suffered neurological complications, 16 of which (12.5%) were TNEs and 7 of which (5.5%) were PNEs. The median extent of BBBD was focal in asymptomatic patients as compared to hemispheric and lobar in the TNE and PNE groups, respectively (p < 0.001). The American Society of Anesthesiologists physical status classification predicted the extent of BBBD (p = 0.046). Lesions on DWI were noted in 34 asymptomatic patients (32.4%) compared to 9 patients (56.3%) with TNEs and all 7 patients (100%) with PNEs (p < 0.001). The median number of DWI lesions was 0 (range 0-18 lesions) in the asymptomatic group compared to 1.5 (range 0-8 lesions) and 8 (range 1-13 lesions) in the TNE and PNE groups, respectively (p < 0.001). Smoking (p = 0.008), older age (p = 0.002), and longer surgery (p = 0.006) were positively associated with the number of lesions on DWI. On multivariate analysis, intraarterial verapamil (p = 0.02, OR 8.01, 95% CI 1.35-47.43) and extent of BBBD (p < 0.001, OR 58.58, 95% CI 9.48-361.84) were positively associated with the development of TNEs, while intravenous infusion of midazolam during surgery (p = 0.02, OR 6.03, 95% CI 1.29-28.20) was negatively associated. An increased number of lesions on DWI was the only significant predictor for the development of PNEs (p < 0.001, OR 49.85, 95% CI 5.56-447.10). CONCLUSIONS: An increasing extent of BBBD was associated with the development of TNEs, whereas an increasing number of lesions on DWI was significantly associated with the development of PNEs. BBBD imaging using pcFLAIR may serve as a valuable biomarker for detecting subtle cerebral ischemia and stratifying the risk for ischemic events.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Procedimentos Endovasculares/efeitos adversos , Aneurisma Intracraniano/diagnóstico por imagem , Angiografia por Ressonância Magnética/métodos , Doenças do Sistema Nervoso/diagnóstico por imagem , Complicações Pós-Operatórias/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Barreira Hematoencefálica/diagnóstico por imagem , Estudos de Coortes , Embolização Terapêutica/efeitos adversos , Feminino , Humanos , Aneurisma Intracraniano/cirurgia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Stents Metálicos Autoexpansíveis/efeitos adversos , Resultado do Tratamento , Adulto Jovem
6.
Interv Neuroradiol ; 26(2): 156-163, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31852417

RESUMO

BACKGROUND: The LVIS Jr device holds a number of advantages but poses unique technical challenges compared to such, especially, complex multistent constructs. We report our experience with the technical feasibility and early to mid-term outcomes of Y-stent-assisted coiling with the LVIS Jr using a simple, single microcatheter technique. METHODS: Using a departmental database, we retrospectively reviewed a single surgeon's experience with Y-stent-assisted coiling with LVIS Jr over a three-year period. Eighteen aneurysms in 17 patients were treated over this period. We assessed the technical success of the procedures, the initial and follow-up radiographic success with the modified Raymond-Roy occlusion score and follow-up clinical outcome with the modified Rankin scale. RESULTS: All stents were successfully deployed, and 17 of 18 aneurysms were successfully coiled at the initial treatment for a technical success rate of 94.4%. Of the 17 aneurysms with follow-up imaging, all were modified Raymond-Roy grade 1 or 2. One aneurysm required retreatment for coil compaction and a growing neck. There were two immediate postprocedure symptomatic strokes and one delayed stroke related to antiplatelet non-compliance. The two immediate symptomatic strokes recovered to neurological baseline with no residual deficits by the time of discharge. The long-term morbidity rate was 5.5%. The mortality rate was 0%. All patients had a modified Rankin Scale ≤ 2 at most recent follow-up. CONCLUSION: Treatment with LVIS Jr Y-stent constructs via a single microcatheter technique is technically feasible with good radiographic and clinical outcomes.


Assuntos
Aneurisma Intracraniano/cirurgia , Stents , Adulto , Idoso , Anticoagulantes/uso terapêutico , Catéteres , Angiografia Cerebral , Artérias Cerebrais/diagnóstico por imagem , Artérias Cerebrais/cirurgia , Feminino , Seguimentos , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/mortalidade , Masculino , Pessoa de Meia-Idade , Inibidores da Agregação Plaquetária/uso terapêutico , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/terapia , Reoperação , Retratamento , Acidente Vascular Cerebral/etiologia , Resultado do Tratamento
7.
Neurosurgery ; 84(6): 1261-1268, 2019 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-29741656

RESUMO

BACKGROUND: Hemodynamics plays a critical role in the development, growth, and rupture of intracranial aneurysms. This data could be vital in determining individual aneurysm rupture risk and could facilitate our understanding of aneurysms. OBJECTIVE: To present the largest prospective cross-sectional cohort study of intrasaccular pressure recordings of ruptured and nonruptured intracranial aneurysms and describe the hemodynamic differences that exist between ruptured and nonruptured aneurysms. METHODS: During endovascular treatment, a standard 1.8-Fr 200 m length microcatheter was navigated into the dome of the aneurysm prior to coil embolization. With the microcatheter centralized within the dome of the aneurysm, an arterial pressure transducer was attached to the proximal end of the microcatheter to measure the stump pressure inside the aneurysm dome. RESULTS: In 68 aneurysms (28 ruptured, 40 nonruptured), we observed that ruptured cerebral aneurysms had a lower systolic and mean arterial pressure compared to nonruptured cohort (P = .0008). Additionally, the pulse pressures within the dome of ruptured aneurysms were significantly more narrow than that of unruptured aneurysms (P = .0001). These findings suggest that there may be an inherent difference between ruptured and nonruptured aneurysms and such recordings obtained during routine digital subtraction angiography could potentially become a widely applied technique to augment risk stratification of aneurysms. CONCLUSION: Our preliminary data present new evidence distinguishing ruptured from unruptured aneurysms that may have a critical role as a predictive parameter to stratify the natural history of nonruptured intracranial aneurysms and as a new avenue for future investigation.


Assuntos
Aneurisma Roto/fisiopatologia , Pressão Arterial/fisiologia , Hemodinâmica/fisiologia , Aneurisma Intracraniano/fisiopatologia , Idoso , Aneurisma Roto/diagnóstico por imagem , Aneurisma Roto/terapia , Angiografia Digital/métodos , Angiografia Cerebral/métodos , Estudos de Coortes , Estudos Transversais , Procedimentos Endovasculares , Feminino , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
9.
Surg Neurol Int ; 9: 123, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30009087

RESUMO

BACKGROUND: Neuroendovascular techniques have significantly altered the treatment paradigm of cerebrovascular diseases. Since the introduction of distal cerebral protection devices (DCPD), the incidence of embolic strokes during carotid artery stenting (CAS) has been significantly reduced. Treatment guidelines for retained foreign bodies in the cerebral vasculature do not exist. CASE DESCRIPTION: Here, we present the case of an 88-year-old male who, during carotid artery angioplasty and stenting for symptomatic carotid artery stenosis, suffered from a retained distal protection device ultimately requiring open surgical carotid endarterectomy including removal of the retained device and stent. CONCLUSIONS: Carotid artery angioplasty and stenting utilizing distal protection devices is a commonly employed technique that may rarely result in retained devices. Knowledge of how to retrieve foreign bodies and the salvage techniques are essential to prevent complications from CAS.

10.
Int J Sports Med ; 39(8): 596-603, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29883988

RESUMO

This pilot study aimed to evaluate the differential effects of a remote ischemic preconditioning (rIPC) manoeuvre on performance and red blood cell (RBC) deformability compared to a sham control and a placebo setting. Ten male subjects performed three test settings in a single-blind, crossover, and randomized control design. All settings started with 20 min of rest and were followed by 4 cycles of occlusion/reperfusion consisting of 5 min each. During rIPC and placebo, the cuff pressure was inflated to 200 mmHg and 120 mmHg, respectively. During the sham control setting, 10 mmHg pressure was applied. All tests were followed by a cycle exercise with lactate diagnostics. Power at 2 and 4 mmol/l lactate thresholds were calculated. RBC deformability was measured before and after the respective manoeuvre. Results showed that no effect resulted from any manoeuvre on performance values or RBC deformability. But 6 subjects showed a higher power at the 2 mmol/l threshold, and 5 subjects exerted higher power at the 4 mmol/l threshold when the rIPC manoeuvre preceded the exercise. In these responsive subjects, RBC deformability also improved. Hence, rIPC effects are much influenced by the subjects' responsiveness, and improved RBC deformability might contribute to enhanced performance in responsive subjects.


Assuntos
Desempenho Atlético/fisiologia , Deformação Eritrocítica , Exercício Físico/fisiologia , Precondicionamento Isquêmico , Limiar Anaeróbio/fisiologia , Estudos Cross-Over , Teste de Esforço , Frequência Cardíaca/fisiologia , Humanos , Ácido Láctico/sangue , Masculino , Projetos Piloto , Método Simples-Cego , Adulto Jovem
11.
J Neurosurg ; : 1-9, 2018 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-29749910

RESUMO

OBJECTIVECerebrovascular bypass surgery is a challenging yet important neurosurgical procedure that is performed to restore circulation in the treatment of carotid occlusive diseases, giant/complex aneurysms, and skull base tumors. It requires advanced microsurgical skills and dedicated training in microsurgical techniques. Most available training tools, however, either lack the realism of the actual bypass surgery (e.g., artificial vessel, chicken wing models) or require special facilities and regulations (e.g., cadaver, live animal, placenta models). The aim of the present study was to design a readily accessible, realistic, easy-to-build, reusable, and high-fidelity simulator to train neurosurgeons or trainees on vascular anastomosis techniques even in the operating room.METHODSThe authors used an anatomical skull and brain model, artificial vessels, and a water pump to simulate both extracranial and intracranial circulations. They demonstrated the step-by-step preparation of the bypass simulator using readily available and affordable equipment and consumables.RESULTSAll necessary steps of a superficial temporal artery-middle cerebral artery bypass surgery (from skin opening to skin closure) were performed on the simulator under a surgical microscope. The simulator was used by both experienced neurosurgeons and trainees. Feedback survey results from the participants of the microsurgery course suggested that the model is superior to existing microanastomosis training kits in simulating real surgery conditions (e.g., depth, blood flow, anatomical constraints) and holds promise for widespread use in neurosurgical training.CONCLUSIONSWith no requirement for specialized laboratory facilities and regulations, this novel, low-cost, reusable, high-fidelity simulator can be readily constructed and used for neurosurgical training with various scenarios and modifications.

12.
J Neurointerv Surg ; 10(5): 462-466, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-28918386

RESUMO

BACKGROUND: The angiographic evaluation of previously coiled aneurysms can be difficult yet remains critical for determining re-treatment. OBJECTIVE: The main objective of this study was to determine the inter-rater reliability for both the Raymond Scale and per cent embolization among a group of neurointerventionalists evaluating previously embolized aneurysms. METHODS: A panel of 15 neurointerventionalists examined 92 distinct cases of immediate post-coil embolization and 1 year post-embolization angiographs. Each case was presented four times throughout the study, along with alterations in demographics in order to evaluate intra-rater reliability. All respondents were asked to provide the per cent embolization (0-100%) and Raymond Scale grade (1-3) for each aneurysm. Inter-rater reliability was evaluated by computing weighted kappa values (for the Raymond Scale) and intraclass correlation coefficients (ICC) for per cent embolization. RESULTS: 10 neurosurgeons and 5 interventional neuroradiologists evaluated 368 simulated cases. The agreement among all readers employing the Raymond Scale was fair (κ=0.35) while concordance in per cent embolization was good (ICC=0.64). Clinicians with fewer than 10 years of experience demonstrated a significantly greater level of agreement than the group with greater than 10 years (κ=0.39 and ICC=0.70 vs κ=0.28 and ICC=0.58). When the same aneurysm was presented multiple times, clinicians demonstrated excellent consistency when assessing per cent embolization (ICC=0.82), but moderate agreement when employing the Raymond classification (κ=0.58). CONCLUSIONS: Identifying the per cent embolization in previously coiled aneurysms resulted in good inter- and intra-rater agreement, regardless of years of experience. The strong agreement among providers employing per cent embolization may make it a valuable tool for embolization assessment in this patient population.


Assuntos
Embolização Terapêutica/normas , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Neurocirurgiões/normas , Radiologistas/normas , Embolização Terapêutica/métodos , Feminino , Humanos , Masculino , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Estudos Retrospectivos
13.
J Neurointerv Surg ; 8(3): 300-4, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25583531

RESUMO

BACKGROUND: The angioarchitectural features of an arteriovenous malformation (AVM) provide key information regarding natural history and treatment planning. Because of rapid filling and vascular overlap, two-dimensional (2D) and three-dimensional (3D) digital subtraction angiography (DSA) are often suboptimal for evaluation of these features. We have developed an algorithm that derives a series of fully time-resolved 3D DSA volumes (four-dimensional (4D) DSA) at up to 30 frames/s from a conventional 3D DSA. The temporal/spatial resolution of 4D reconstructions is significantly higher than that provided by current MR angiography and CT angiography techniques. 4D reconstruction allows viewing of an AVM from any angle at any time during its opacification. This feasibility study investigated the potential of 4D DSA to improve the ability to analyze angioarchitectural features compared with conventional 2D and 3D DSA. METHODS: 2D, 3D, and 4D DSA reconstructions of angiographic studies of six AVMs were evaluated by three cerebrovascular neurosurgeons and one interventional neuroradiologist. These observers evaluated the ability of each modality to visualize the angioarchitectural features of the AVMs. They also compared the information provided using the combination of 2D and 3D DSA with that provided by a 4D DSA reconstruction. RESULTS: By consensus, 4D DSA provided the best ability to visualize the internal features of the AVM including intranidal aneurysms, fistulae, venous obstructions, and sequence of filling and draining. 2D and 3D images in comparison were limited because of overlap of the vasculature. CONCLUSIONS: In this small series, 4D DSA provided better ability to visualize the angioarchitecture of an AVM than conventional methods. Further experience is required to determine the ultimate utility of this technique.


Assuntos
Algoritmos , Angiografia Digital/métodos , Imageamento Tridimensional/métodos , Malformações Arteriovenosas Intracranianas/diagnóstico por imagem , Adulto , Idoso , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
14.
Artigo em Inglês | MEDLINE | ID: mdl-29200594

RESUMO

Currently, clinical acquisition of IV 3D-DSA requires two separate scans: one mask scan without contrast medium and a filled scan with contrast injection. Having two separate scans adds radiation dose to the patient and increases the likelihood of suffering inadvertent patient motion induced mis-registration and the associated mis-registraion artifacts in IV 3D-DSA images. In this paper, a new technique, SMART-RECON is introduced to generate IV 3D-DSA images from a single Cone Beam CT (CBCT) acquisition to eliminate the mask scan. Potential benefits of eliminating mask scan would be: (1) both radiation dose and scan time can be reduced by a factor of 2; (2) intra-sweep motion can be eliminated; (3) inter-sweep motion can be mitigated. Numerical simulations were used to validate the algorithm in terms of contrast recoverability and the ability to mitigate limited view artifacts.

15.
J Neurointerv Surg ; 8(9): 965-8, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26453606

RESUMO

BACKGROUND: Accurate vessel size measurement is important for neurointervention. Modern angiographic equipment offers various two-dimensional (2D) and 3D measurement methods that have not been systematically evaluated for accuracy and reliability. OBJECTIVE: To evaluate these methods using anthropomorphic vessel phantoms. MATERIALS AND METHODS: Tubing of known sizes (2-5 mm, 1 mm increments) was embedded in 3D-printed skulls to simulate the middle cerebral artery, internal carotid artery, and basilar artery. Each phantom was imaged to gain 3D DSA, 2D DSA, and DynaCT images. Three identical measurement locations were identified on each simulated vessel. Eight measurement methods (four 2D, three 3D, and one DynaCT) were evaluated. Measurements were performed by three independent experienced users on three separate occasions. Intraclass correlation and independent non-parametric analysis were carried out to evaluate the reliability and accuracy of these measurement methods. RESULTS: Better reliability was noted for the automatic measurement methods than for the corresponding manual measurement methods. The mean differences with the ground truth for all methods ranged from -0.12 to 0.03 with small SEs (0.02-0.03) and SDs (0.10-0.18). The smallest absolute mean differences were achieved in two automatic measurement methods based on 2D manual calibration and 3D images. In comparison with these two methods, results of measurements based on 2D autocalibration were statistically different. CONCLUSIONS: In our study, automatic analysis using 3D or 2D was the preferred measurement method. Manual calibration on 2D angiograms is necessary to improve the measurement accuracy. It is not known how our results may pertain to other angiographic systems.


Assuntos
Angiografia Digital/métodos , Angiografia Cerebral/métodos , Angiografia por Tomografia Computadorizada/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imagens de Fantasmas , Artéria Basilar/diagnóstico por imagem , Artéria Carótida Interna/diagnóstico por imagem , Humanos , Artéria Cerebral Média/diagnóstico por imagem , Reprodutibilidade dos Testes , Estatística como Assunto
16.
J Neurol Surg B Skull Base ; 75(6): 435-44, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25452903

RESUMO

Background and Study Aim To enhance the visualization of the intracranial vasculature of cadavers under gross examination with a combination of imaging modalities. Material and Methods A total of 20 cadaver heads were used to test two different perfusion techniques. First, fixed cadaver heads were perfused with water; second, fresh cadavers were perfused with saline and 10% formalin. Subsequently, brains were removed and fixed. The compounds used were silicone rubber, silicone rubber mixed with powdered barium sulfate, and silicone rubber mixed with tantalum dioxide prepared by the first perfusion technique and gelatin mixed with liquid barium prepared with the second technique. Conventional X-ray imaging, computed tomography (CT), dynamic computed tomography (dCT), and postprocessing three-dimensional (3D) images were used to evaluate all the heads. Results Gelatinized barium was better visualized when compared with tantalum dioxide in conventional X-ray images. The blood vessels injected with either tantalum dioxide or gelatinized barium demonstrated a higher enhancement than the surrounding soft tissues with CT or dCT. The quality of the 3D reconstruction of the intracranial vasculature was significantly better in the CT images obtained from the gelatinized barium group. Conclusions Radiologic examinations of the heads injected with gelatinized barium facilitates the 3D understanding of cerebrovascular anatomy as an important tool for neuroanatomy training.

17.
J Med Case Rep ; 8: 380, 2014 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-25416614

RESUMO

INTRODUCTION: Non-aneurysmal spontaneous subarachnoid hemorrhage is characterized by an accumulation of a limited amount of subarachnoid hemorrhage, predominantly around the midbrain, and a lack of blood in the brain parenchyma or ventricular system. It represents 5% of all spontaneous subarachnoid hemorrhage cases. In spite of extensive investigation, understanding of the mechanisms leading to perimesencephalic non-aneurysmal subarachnoid hemorrhage remains incompletely defined. A growing body of evidence has supported a familial predisposition for non-aneurysmal spontaneous subarachnoid hemorrhage. CASE PRESENTATION: A 39-year-old Caucasian man presented with sudden onset headache associated with diplopia. His computed tomography scan revealed perimesencephalic subarachnoid hemorrhage. A cerebral angiogram showed no apparent source of bleeding. He was treated conservatively and discharged after 1 week without any neurological deficits. The older brother of the first case, a 44-year-old Caucasian man, presented 1.5 years later with acute onset of headache and his computed tomography scan also showed perimesencephalic non-aneurysmal subarachnoid hemorrhage. He was discharged home with normal neurological examination 1 week later. Follow-up angiograms did not reveal any source of bleeding in either patient. CONCLUSIONS: We report the cases of two siblings with perimesencephalic non-aneurysmal subarachnoid hemorrhage, which may further suggest a familial predisposition of non-aneurysmal spontaneous subarachnoid hemorrhage and may also point out the possible higher risk of perimesencephalic non-aneurysmal subarachnoid hemorrhage in the first-degree relatives of patients with perimesencephalic non-aneurysmal subarachnoid hemorrhage.


Assuntos
Veias Cerebrais/anormalidades , Mesencéfalo/irrigação sanguínea , Irmãos , Hemorragia Subaracnóidea/diagnóstico , Adulto , Angiografia Cerebral , Humanos , Angiografia por Ressonância Magnética , Masculino , Mesencéfalo/patologia , Hemorragia Subaracnóidea/genética , Tomografia Computadorizada por Raios X
18.
Neurosurg Clin N Am ; 25(3): 425-35, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24994082

RESUMO

Endovascular management of intracranial aneurysms has advanced significantly over the last couple decades and continues to evolve, including aneurysms within the subgroup of supraclinoid internal carotid artery (ophthalmic, superior hypophyseal, posterior communicating, anterior choroidal, dorsal wall/blister, and carotid terminus).


Assuntos
Doenças das Artérias Carótidas/cirurgia , Artéria Carótida Interna/cirurgia , Procedimentos Endovasculares , Aneurisma Intracraniano/cirurgia , Adulto , Artéria Carótida Interna/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
19.
J Neurointerv Surg ; 6(7): 561-4, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24062256

RESUMO

PURPOSE: Simulation techniques in neurosurgical training are becoming more important. The purpose of this study was to determine whether silicone vascular models used in the angiography suite can render improvement in trainee performance and safety in neuroendovascular procedures. METHODS: 10 residents from neurosurgery and radiology training programs were asked to perform a diagnostic angiogram on a silicone based vascular model (United Biologics, Tustin, USA). This was done in the angiography suite with the full biplane fluoroscopy machine (Siemens, Munich, Germany). On their first attempt, they were coached by a faculty member trained in endovascular neurosurgery; on their second attempt, they received coaching only if the procedure had stalled. Technique was scored on multiple criteria by the faculty, and total time and fluoroscopy time were recorded on both attempts. RESULTS: In this group of 10 residents, overall procedure time significantly decreased from 51 to 42 min (p=0.01), and total fluoro time significantly decreased from 12 to 9 min (p=0.002) between the first attempt and the second attempt. Technical skill increased significantly in navigation, vessel selection, projection setup, and road map usage. CONCLUSIONS: Silicone vascular models used in the angiography suite, with the clinical working tools and biplane fluoroscopy, provide a valuable experience for training residents in diagnostic angiography, and improved performance and safety.


Assuntos
Simulação por Computador , Angiofluoresceinografia/métodos , Manequins , Neurocirurgia/educação , Radiologia/educação , Competência Clínica , Avaliação Educacional , Procedimentos Endovasculares/métodos , Humanos , Internato e Residência , Neuroimagem , Silicones
20.
Clin Neurol Neurosurg ; 115(3): 298-303, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22770541

RESUMO

BACKGROUND: Although, the relationship of spontaneous subarachnoid hemorrhage (SAH) to climatic or circadian factors has been widely studied, epidemiologic, circardian and climatic factors in non-aneurysmal SAH (naSAH), particularly perimesencephalic SAH (PMH), has not been reported before. OBJECTIVE: For the first time, demographic, climatic, and circadian variables are examined together as possible contributing factors comparing aSAH and naSAH. METHODS: We reviewed records for 384 patients admitted to University of Wisconsin Neurosurgery Service from January 2005 to December 2010 with spontaneous non-traumatic SAH. Patients were grouped as aSAH (n=338) or naSAH (n=46) on clinical and radiological criteria. PMH (n=32) was identified as a subgroup of naSAH based on radiological criteria. We logged demographic data, time of SAH, temperature at onset and atmospheric pressure at onset. The three subgroups were compared. RESULTS: Aneurysmal SAH occurred most often from 6am to 12pm (p<0.001); this correlation was not found in naSAH or PMH subgroups. Demographic analysis demonstrated predominance of female gender (p=0.008) and smoking (p=0.002) in aSAH, with predominance of hypercholesterolemia in naSAH (p=0.033). Atmospheric pressure, correlated with aSAH in the main county referral area, where we had detailed weather data (p<0.05); however, there was no weather correlation in the entire referral region taken together. Multivariate analysis supported a statistical difference only in smoking status between aSAH and naSAH groups (p=0.0159). CONCLUSION: Statistical differences in gender, smoking status, and history of hypercholesterolemia support a clinical distinction between aSAH and naSAH. Furthermore, circadian patterning of aSAH is not reproduced in naSAH, supporting pathophysiologic differences. Only smoking status provides a robust difference in aSAH and naSAH groups. Our data prompt further investigation into the relationship between aSAH and atmospheric pressure.


Assuntos
Ritmo Circadiano/fisiologia , Clima , Hemorragia Subaracnóidea/epidemiologia , Pressão do Ar , Demografia , Feminino , Geografia , Humanos , Hipercolesterolemia/complicações , Hipercolesterolemia/epidemiologia , Classificação Internacional de Doenças , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Fatores de Risco , Fatores Sexuais , Fumar/epidemiologia , Temperatura , Fatores de Tempo , Tempo (Meteorologia) , Wisconsin/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...