Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 190
Filtrar
2.
Heart Rhythm ; 2024 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-38493989

RESUMO

BACKGROUND: Atrial high-rate episodes (AHREs) are frequent in patients with cardiac implantable electronic devices. A decrease in device-detected P-wave amplitude may be an indicator of periods of increased risk of AHRE. OBJECTIVE: The objective of this study was to assess the association between P-wave amplitude and AHRE incidence. METHODS: Remote monitoring data from 2579 patients with no history of atrial fibrillation (23% pacemakers and 77% implantable cardioverter-defibrillators, of which 40% provided cardiac resynchronization therapy) were used to calculate the mean P-wave amplitude during 1 month after implantation. The association with AHRE incidence according to 4 strata of daily burden duration (≥15 minutes, ≥6 hours, ≥24 hours, ≥7 days) was investigated by adjusting the hazard ratio with the CHA2DS2-VASc score. RESULTS: The adjusted hazard ratio for 1-mV lower mean P-wave amplitude during the first month increased from 1.10 (95% confidence interval [CI], 1.05-1.15; P < .001) to 1.18 (CI, 1.09-1.28; P < .001) with AHRE duration strata from ≥15 minutes to ≥7 days independent of the CHA2DS2-VASc score. Of 871 patients with AHREs, those with 1-month P-wave amplitude <2.45 mV had an adjusted hazard ratio of 1.51 (CI, 1.19-1.91; P = .001) for progression of AHREs from ≥15 minutes to ≥7 days compared with those with 1-month P-wave amplitude ≥2.45 mV. Device-detected P-wave amplitudes decreased linearly during the 1 year before the first AHRE by 7.3% (CI, 5.1%-9.5%; P < .001 vs patients without AHRE). CONCLUSION: Device-detected P-wave amplitudes <2.45 mV were associated with an increased risk of AHRE onset and progression to persistent forms of AHRE independent of the patient's risk profile.

3.
Artigo em Inglês | MEDLINE | ID: mdl-38507041

RESUMO

BACKGROUND: The withdrawal timing of direct oral anticoagulants (DOACs) among patients in need of elective invasive surgery is based on DOAC pharmacokinetics in order to perform the procedure out of the DOAC peak plasma concentration. We aimed to investigate the prevalence and predictors of plasma levels of DOACs out of trough range in patients with atrial fibrillation (AF) in need of elective cardiac procedure. MATERIALS AND METHODS: We evaluated all consecutive AF patients on DOAC therapy in need of elective cardiac procedure, admitted to our division from January 2022 to March 2022. All patients underwent DOAC plasma dosing the morning of procedure day. They were categorized as in range, above range, and below range, according to the DOAC reference range at the downstream point. The timing of discontinuation of DOAC therapy was considered as appropriate or not, according to the current recommendations. The clinical predictors of out-of-range DOAC plasma levels have been evaluated. RESULTS: We included 90 consecutive AF patients (56.6% male, mean age 72.95 ± 10.12 years); 74 patients (82.22%) showed DOAC concentration out of the expected reference range. In half of them (n, 37), the DOAC plasma concentration was below the trough reference range. Of the study population, 17.7% received inappropriate DOAC dosages (10% overdosing, 7% underdosing), and 35.5% had incorrect timing of DOAC withdrawal (26% prolonged, 9.5% shortened). At multivariable analysis, inappropriate longer DOAC withdrawal period (OR 10.13; P ≤ 0.0001) and increased creatinine clearance (OR 1.01; P = 0.0095) were the independent predictors of plasma DOAC levels below the therapeutic trough range. In contrast, diabetes mellitus (OR 4.57; P = 0.001) was the only independent predictor of DOAC plasma level above the therapeutic trough range. CONCLUSION: Increased creatinine clearance and inappropriate longer drug withdrawal period are the only independent predictors of DOAC plasma levels below the reference range; in contrast, diabetes is significantly correlated with DOAC plasma levels above the reference.

5.
Heart Rhythm ; 2024 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-38428448

RESUMO

BACKGROUND: Cardiac resynchronization therapy (CRT) with biventricular pacing (BVP) is a well-established therapy in patients with reduced left ventricular ejection fraction, heart failure, and left bundle branch block. Left bundle branch area pacing (LBBAP) has recently been shown to be a feasible and effective alternative to BVP. Comparative data on the risk of complications between LBBAP and BVP among patients undergoing CRT are lacking. OBJECTIVE: The aim of this study was to compare the long-term risk of procedure-related complications between LBBAP and BVP in a cohort of patients undergoing CRT. METHODS: This prospective, multicenter, observational study enrolled 668 consecutive patients (mean age 71.2 ± 10.0 years; 52.2% male; 59.4% with New York Heart Association class III-IV heart failure symptoms) with left ventricular ejection fraction 33.4% ± 4.3% who underwent BVP (n = 561) or LBBAP (n = 107) for a class I or II indication for CRT. Propensity score matching for baseline characteristics yielded 93 matched pairs. The rate and nature of intraprocedural and long-term post-procedural complications occurring during follow-up were prospectively collected and compared between the 2 groups. RESULTS: During a mean follow-up of 18 months, procedure-related complications were observed in 16 patients: 12 in BVP (12.9%) and 4 in LBBAP (4.3%) (P = .036). Compared with patients who underwent LBBAP, those who underwent BVP showed a lower complication-free survival (P = .032). In multivariate analysis, BVP resulted an independent predictive factor associated with a higher risk of complications (hazard ratio 3.234; P = .042). Complications related to the coronary sinus lead were most frequently observed in patients who underwent BVP (50.0% of all complications). CONCLUSION: LBBAP was associated with a lower long-term risk of device-related complications compared with BVP in patients with an indication for CRT.

6.
Clin Auton Res ; 34(1): 137-142, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38402334

RESUMO

BACKGROUND: Approximately 50% of patients with unexplained syncope and negative head-up tilt test (HUTT) who have an electrocardiogram (ECG) documentation of spontaneous syncope during implantable loop recorder (ILR) show an asystolic pause at the time of the event. OBJECTIVE: The aim of the study was to evaluate the age distribution and clinical predictors of asystolic syncope detected by ILR in patients with unexplained syncope and negative HUTT. METHODS: This research employed a retrospective, single-center study of consecutive patients. The ILR-documented spontaneous syncope was classified according to the International Study on Syncope of Uncertain Etiology (ISSUE) classification. RESULTS: Among 113 patients (54.0 ± 19.6 years; 46% male), 49 had an ECG-documented recurrence of syncope during the observation period and 28 of these later (24.8%, corresponding to 57.1% of the patients with a diagnostic event) had a diagnosis of asystolic syncope at ILR: type 1A was present in 24 (85.7%), type 1B in 1 (3.6%), and type 1C in 3 (10.7%) patients. The age distribution of asystolic syncope was bimodal, with a peak at age < 19 years and a second peak at the age of 60-79 years. At Cox multivariable analysis, syncope without prodromes (OR 3.7; p = 0.0008) and use of beta blockers (OR 3.2; p = 0.002) were independently associated to ILR-detected asystole. CONCLUSIONS: In patients with unexplained syncope and negative HUTT, the age distribution of asystolic syncope detected by ILR is bimodal, suggesting a different mechanism responsible for asystole in both younger and older patients. The absence of prodromes and the use of beta blockers are independent predictors of ILR-detected asystole.


Assuntos
Parada Cardíaca , Síncope , Humanos , Masculino , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Feminino , Estudos Retrospectivos , Distribuição por Idade , Síncope/diagnóstico , Síncope/etiologia , Parada Cardíaca/complicações , Eletrocardiografia , Eletrocardiografia Ambulatorial/efeitos adversos
7.
Heart Rhythm ; 21(5): 555-561, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38242222

RESUMO

BACKGROUND: There are limited real-world data on the extended prognosis of patients with drug-induced type 1 Brugada electrocardiogram (ECG). OBJECTIVE: We assessed the clinical outcomes and predictors of life-threatening arrhythmias in patients with drug-induced type 1 Brugada ECG. METHODS: This multicenter retrospective study, conducted at 21 Italian and Swiss hospitals from July 1997 to May 2021, included consecutive patients with drug-induced type 1 ECG. The primary outcome, a composite of appropriate ICD therapies and sudden cardiac death, was assessed along with the clinical predictors of these events. RESULTS: A total of 606 patients (mean age 49.7 ± 14.7 years; 423 [69.8%] men) were followed for a median of 60.3 months (interquartile range 23.0-122.4 months). Nineteen patients (3.1%) experienced life-threatening arrhythmias, with a median annual event rate of 0.5% over 5 years and 0.25% over 10 years. The SCN5A mutation was the only predictor of the primary outcome (hazard ratio 4.54; P = .002), whereas a trend was observed for unexplained syncope (hazard ratio 3.85; P = .05). In patients who were asymptomatic at presentation, the median annual rate of life-threatening arrhythmias is 0.24% over 5 years and increases to 1.2% if they have inducible ventricular fibrillation during programmed ventricular stimulation. CONCLUSION: In patients with drug-induced type 1 Brugada ECG, the annual risk of life-threatening arrhythmias is low, with the SCN5A mutation as the only independent predictor. Unexplained syncope correlated with worse clinical outcomes. Ventricular fibrillation inducibility at programmed ventricular stimulation significantly increases the median annual rate of life-threatening arrhythmias from 0.24% to 1.2% over 5 years.


Assuntos
Síndrome de Brugada , Eletrocardiografia , Sistema de Registros , Humanos , Masculino , Síndrome de Brugada/fisiopatologia , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/epidemiologia , Feminino , Pessoa de Meia-Idade , Estudos Retrospectivos , Prognóstico , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Itália/epidemiologia , Seguimentos , Desfibriladores Implantáveis , Suíça/epidemiologia , Fatores de Tempo , Taxa de Sobrevida/tendências , Adulto
8.
Pacing Clin Electrophysiol ; 46(12): 1500-1508, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37885375

RESUMO

BACKGROUND: Remote monitoring is recommended for patients with implantable cardiac monitors (ICMs), but compared to other cardiac implantable devices, ICMs are less accurate and transmit a higher number of alerts. OBJECTIVE: The aim of this study was to investigate the predictors of false-positive (FP) arrhythmic alerts in patients with unexplained syncope who were implanted with ICM and followed by an automatic remote monitoring system. METHODS: We retrospectively evaluated all consecutive patients who received a long-sensing vector ICM for unexplained syncope between January 2019 to September 2021 at our Syncope Unit. The primary endpoint was the incidence of the first FP episode. The secondary endpoints included assessing the incidence of FP episodes for all types of algorhythms and indentifying the reasons for the misdetection of these episodes. RESULTS: Among 105 patients (44.8% males, median age 51 years), 51 (48.6%) transmitted at least one FP alert during a median follow-up of 301 days. The presence of pre-ventricular complexes (PVCs) on the resting electrocardiogram was the only clinical characteristic associated with an increased risk of FP alerts (adjusted Hazard ratio [HR] 5.76 [2.66-12.4], p = 0.010). The other significant device-related variables were a low-frequency filter at 0.05 Hz versus the default 0.5 Hz (adjusted HR 3.82 [1.38-10.5], p = 0.010) and the R-wave amplitude (adjusted HR 0.35 [0.13-0.99], p = 0.049). CONCLUSION: Patients who have PVCs are at higher risk of inappropriate ICM activations. To reduce the occurrence of FP alerts, it may be beneficial to target a large R-wave amplitude during device insertion and avoid programming a low-frequency filter at 0.05 Hz.


Assuntos
Arritmias Cardíacas , Eletrocardiografia , Masculino , Humanos , Pessoa de Meia-Idade , Feminino , Estudos Retrospectivos , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/complicações , Síncope/diagnóstico , Síncope/etiologia , Eletrocardiografia Ambulatorial
9.
Pacing Clin Electrophysiol ; 46(10): 1258-1268, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37665040

RESUMO

BACKGROUND: Conduction system pacing (CSP), including His-bundle pacing (HBP) and left bundle branch area pacing (LBBAP), have been proposed as alternatives to biventricular pacing (BVP) in patients scheduled for ablate and pace (A&P) strategy. The aim of this study was to compare the clinical outcomes, including the rate and nature of device-related complications, between BVP and CSP in a cohort of patients undergoing A&P. METHODS: Prospective, multicenter, observational study, enrolling consecutive patients undergoing A&P. The risk of device-related complications and of heart failure (HF) hospitalization was prospectively assessed. RESULTS: A total of 373 patients (75.3 ± 8.7 years, 53.9% male, 68.9% with NYHA class ≥III) were enrolled: 263 with BVP, 68 with HBP, and 42 with LBBAP. Baseline characteristics of the three groups were similar. Compared to BVP and HBP, LBBAP was associated with the shortest mean procedural and fluoroscopy times and with the lowest acute capture thresholds (all p < .05). At 12-month follow-up LBBAP maintained the lowest capture thresholds and showed the longest estimated residual battery longevity (all p < .05). At 12-months follow-up the three study groups showed a similar risk of device-related complications (5.7%, 4.4%, and 2.4% for BVP, HBP, and LBBAP, respectively; p = .650), and of HF hospitalization (2.7%, 1.5%, and 2.4% for BVP, HBP, and LBBAP, respectively; p = .850). CONCLUSIONS: In the setting of A&P, CSP is a feasible pacing modality, with a midterm safety profile comparable to BVP. LBBAP offers the advantage of reducing procedural times and obtaining lower and stable capture thresholds, with a positive impact on the device longevity.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Masculino , Feminino , Estudos Prospectivos , Sistema de Condução Cardíaco , Doença do Sistema de Condução Cardíaco , Fontes de Energia Elétrica , Insuficiência Cardíaca/terapia , Fascículo Atrioventricular , Resultado do Tratamento , Eletrocardiografia , Estimulação Cardíaca Artificial
10.
Heart ; 110(1): 35-39, 2023 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-37527918

RESUMO

OBJECTIVE: The study compared clinical characteristics and response at head-up tilt test (HUTT) between situational (SS) and vasovagal syncope (VVS). METHODS: Consecutive patients who underwent nitroglycerin-potentiated HUTT were retrospectively dichotomised into two groups: those with a history of SS and those with a history of VVS. The patients with SS were further subdivided into patients with SS alone and with SS and at least one episode of VVS. RESULTS: 1285 patients were enrolled: 246 (19.1%) had SS (SS alone in 121 and SS+VVS in 125). Patients with SS were older (48.8±20.0 vs 44.4±19.1, p=0.007) and more frequently male (57.3% vs 47.7%, p=0.001). At multivariable analysis, smoking habit (OR 2.28; p<0.0001), history of traumatic syncope (OR 2.29; p=0.0001) and ACE inhibitors/angiotensin II receptor blockers (OR 4.74; p<0.0001) were independently associated with SS. HUTT was positive in 175 (71.1%) patients with SS and in 737 (70.9%) patients with VVS (p=0.9). Patients with SS showed more mixed (42.3% vs 32.0%, p=0.002) and vasodepressor forms (10.6% vs 6.1%, p=0.01) and less cardioinhibitory responses compared with others (18.3% vs 32.8%, p<0.0001). CONCLUSIONS: Compared with VVS, patients with SS have different clinical characteristics and a higher prevalence of hypotensive drugs leading to hypotensive susceptibility. The positivity rate of HUTT is high and similar to that of VVS, although patients with SS show a higher prevalence of hypotensive responses.


Assuntos
Síncope Vasovagal , Síncope , Humanos , Masculino , Estudos Retrospectivos , Síncope/diagnóstico , Síncope/etiologia , Síncope Vasovagal/diagnóstico , Teste da Mesa Inclinada , Nitroglicerina
11.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37536671

RESUMO

AIMS: Patients with cardiomyopathies and channelopathies are usually younger and have a predominantly arrhythmia-related prognosis; they have nearly normal life expectancy thanks to the protection against sudden cardiac death provided by the implantable cardioverter defibrillator (ICD). The subcutaneous ICD (S-ICD) is an effective alternative to the transvenous ICD and has evolved over the years. This study aimed to evaluate the rate of inappropriate shocks (IS), appropriate therapies, and device-related complications in patients with cardiomyopathies and channelopathies who underwent modern S-ICD implantation. METHODS AND RESULTS: We enrolled consecutive patients with cardiomyopathies and channelopathies who had undergone implantation of a modern S-ICD from January 2016 to December 2020 and who were followed up until December 2022. A total of 1338 S-ICD implantations were performed within the observation period. Of these patients, 628 had cardiomyopathies or channelopathies. The rate of IS at 12 months was 4.6% [95% confidence interval (CI): 2.8-6.9] in patients with cardiomyopathies and 1.1% (95% CI: 0.1-3.8) in patients with channelopathies (P = 0.032). No significant differences were noted over a median follow-up of 43 months [hazard ratio (HR): 0.76; 95% CI: 0.45-1.31; P = 0.351]. The rate of appropriate shocks at 12 months was 2.3% (95% CI: 1.1-4.1) in patients with cardiomyopathies and 2.1% (95% CI: 0.6-5.3) in patients with channelopathies (P = 1.0). The rate of device-related complications was 0.9% (95% CI: 0.3-2.3) and 3.2% (95% CI: 1.2-6.8), respectively (P = 0.074). No significant differences were noted over the entire follow-up. The need for pacing was low, occurring in 0.8% of patients. CONCLUSION: Modern S-ICDs may be a valuable alternative to transvenous ICDs in patients with cardiomyopathies and channelopathies. Our findings suggest that modern S-ICD therapy carries a low rate of IS. CLINICAL TRIAL REGISTRATION: URL: http://clinicaltrials.gov/Identifier: NCT02275637.


Assuntos
Cardiomiopatias , Canalopatias , Desfibriladores Implantáveis , Humanos , Desfibriladores Implantáveis/efeitos adversos , Canalopatias/complicações , Canalopatias/terapia , Resultado do Tratamento , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Cardiomiopatias/complicações , Cardiomiopatias/terapia , Sistema de Registros
12.
J Cardiovasc Pharmacol ; 82(3): 196-200, 2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-37405837

RESUMO

ABSTRACT: Sodium-glucose cotransporter 2 inhibitors (SGLT2-i) are a novel class of oral hypoglycemic agents currently used among patients with type 2 diabetes mellitus (T2DM). The effects of SGLT2-i inhibitors on cardiac structure and function are not fully understood. The aim of this study is to evaluate the echocardiographic changing among patients with well-controlled T2DM treated with SGLT2-i in real-world setting. Thirty-five well-controlled T2DM patients (65 ± 9 years, 43.7% male) with preserved left ventricular ejection fraction (LVEF) and 35 age and sex-matched controls were included. T2DM patients underwent clinical and laboratory evaluation; 12-lead surface electrocardiogram; 2-dimensional color Doppler echocardiography at enrolment, before SGLT2-i administration, and at 6 months follow-up after an uninterrupted 10 mg once daily of empagliflozin (n: 21) or dapagliflozin (n: 14). Standard echocardiographic measurements, LV global longitudinal strain (LV-GLS), global wasted work, and global work efficiency were calculated. T2DM patients showed higher E\E' ratio (8.3 ± 2.5 vs. 6.3 ± 0.9; P < 0.0001 ) and lower LV-GLS (15.8 ± 8.1 vs. 22.1 ± 1.4%; P < 0.0001 ) and global myocardial work efficiency (91 ± 4 vs. 94 ± 3%; P: 0.0007 ) compared with age and sex-matched controls. At 6-month follow-up, T2DM patients showed a significant increase in LVEF (58.9 ± 3.2 vs. 62 ± 3.2; P < 0.0001 ), LV-GLS (16.2 ± 2.8 vs. 18.7 ± 2.4%; P = 0.003 ), and global work efficiency (90.3 ± 3.5 vs. 93.3 ± 3.2%; P = 0.0004 ) values; conversely, global wasted work values (161.2 ± 33.6 vs. 112.72 ± 37.3 mm Hg%; P < 0.0001 ) significantly decreased. Well-controlled T2DM patients with preserved LVEF who are treated with a SGLT2-i on top of the guidelines direct medical therapy showed a favorable cardiac remodeling, characterized by the improvement of LV-GLS and myocardial work efficiency.


Assuntos
Diabetes Mellitus Tipo 2 , Disfunção Ventricular Esquerda , Humanos , Masculino , Feminino , Volume Sistólico , Função Ventricular Esquerda , Diabetes Mellitus Tipo 2/diagnóstico , Diabetes Mellitus Tipo 2/tratamento farmacológico , Transportador 2 de Glucose-Sódio/farmacologia , Transportador 2 de Glucose-Sódio/uso terapêutico , Deformação Longitudinal Global , Glucose , Sódio
13.
Eur Heart J ; 44(27): 2473-2479, 2023 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-37264671

RESUMO

BACKGROUND: The traditional nitroglycerin (NTG) head-up tilt test (HUTT) is time-consuming and the test duration is a barrier to widespread utilization in clinical practice. It was hypothesized that a short-duration protocol is not inferior to the traditional protocol regarding the positivity rate and has a similar distribution of hemodynamic response. METHODS AND RESULTS: Patients undergoing HUTT were randomized 1:1 to a 10 min passive phase plus a 10 min 0.3 mg NTG if the passive phase was negative (Fast) or to a 20 min passive phase plus a 15 min 0.3 mg NTG if the passive phase was negative (Traditional). A sample size of 277 patients for each group achieved 80% power to detect an expected difference of 0% with a non-inferiority margin of -10% using a one-sided t-test and assuming a significant level alpha of 0.025. A total of 554 consecutive patients (mean age 46.6 ± 19.3 years, 47.6% males) undergoing HUTT for suspected vasovagal syncope were randomly assigned to the Fast (n = 277) or Traditional (n = 277) protocol. A positive response was defined as the induction of syncope in presence of hypotension/bradycardia, and was observed in 167 (60.3%) patients with Fast and in 162 (58.5%) patients with the Traditional protocol. There was a trend of lesser vasodepressor response (14.8% Fast vs. 20.6% Traditional) which was significant during the passive phase (P = 0.01). CONCLUSION: The diagnostic value of the Fast HUTT protocol is similar to that of the Traditional protocol and therefore the Fast protocol can be used instead of the Traditional protocol.


Assuntos
Nitroglicerina , Síncope Vasovagal , Masculino , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Feminino , Síncope Vasovagal/diagnóstico , Vasodilatadores , Síncope/diagnóstico , Teste da Mesa Inclinada/métodos , Ensaios Clínicos Controlados Aleatórios como Assunto
14.
Europace ; 25(6)2023 06 02.
Artigo em Inglês | MEDLINE | ID: mdl-37350404

RESUMO

AIMS: Subcutaneous implantable cardioverter-defibrillator (S-ICD) therapy is expanding rapidly. However, there are few data on the S-ICD extraction procedure and subsequent patient management. The aim of this analysis was to describe the procedure, management, and outcome of S-ICD extractions in clinical practice. METHODS AND RESULTS: We enrolled consecutive patients who required complete S-ICD extraction at 66 Italian centres. From 2013 to 2022, 2718 patients undergoing de novo implantation of an S-ICD were enrolled. Of these, 71 required complete S-ICD system extraction (17 owing to infection). The S-ICD system was successfully extracted in all patients, and no complications were reported; the median procedure duration was 40 (25th-75th percentile: 20-55) min. Simple manual traction was sufficient to remove the lead in 59 (84%) patients, in whom lead-dwelling time was shorter [20 (9-32) months vs. 30 (22-41) months; P = 0.032]. Hospitalization time was short in the case of both non-infectious [2 (1-2) days] and infectious indications [3 (1-6) days]. In the case of infection, no patients required post-extraction intravenous antibiotics, the median duration of any antibiotic therapy was 10 (10-14) days, and the re-implantation was performed during the same procedure in 29% of cases. No complications arose over a median of 21 months. CONCLUSION: The S-ICD extraction was safe and easy to perform, with no complications. Simple traction of the lead was successful in most patients, but specific tools could be needed for systems implanted for a longer time. The peri- and post-procedural management of S-ICD extraction was free from complications and not burdensome for patients and healthcare system. CLINICAL TRIAL REGISTRATION: URL: http://clinicaltrials.gov/Identifier: NCT02275637.


Assuntos
Desfibriladores Implantáveis , Humanos , Administração Intravenosa , Antibacterianos , Hospitalização , Resultado do Tratamento
15.
Front Cardiovasc Med ; 10: 1193805, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37388638

RESUMO

Background: There are little data on remote monitoring (RM) of implantable loop recorders (ILRs) in patients with unexplained syncope and whether it confers enhanced diagnostic power. Objective: To evaluate the effect of RM in ILR recipients for unexplained syncope for early detection of clinically relevant arrhythmias by comparison with a historical cohort with no RM. Methods: SyncRM is a propensity score (PS)-matched study prospectively including 133 consecutive patients with unexplained syncope and ILR followed up by RM (RM-ON group). A historical cohort of 108 consecutive ILR patients with biannual in-hospital follow-up visits was used as control group (RM-OFF group). The primary endpoint was the time to the clinician's evaluation of clinically relevant arrhythmias (types 1, 2, and 4 of the ISSUE classification). Results: The primary endpoint of arrhythmia evaluation was reached in 38 patients (28.6%) of the RM-ON group after a median time of 46 days (interquartile range, 13-106) and in 22 patients (20.4%) of the RM-OFF group after 92 days (25-368). The PS-matched adjusted ratio of rates of arrhythmia evaluation was 2.53 (95% confidence interval, 1.32-4.86) in the RM-ON vs. RM-OFF group (p = 0.005). Conclusion: In our PS-matched comparison with a historical cohort, RM of ILR patients with unexplained syncope was associated with a 2.5-fold higher chance of evaluations of clinically relevant arrhythmias as compared with biannual in-office follow-up visits.

16.
J Cardiovasc Med (Hagerstown) ; 24(Suppl 2): e97-e105, 2023 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-37186560

RESUMO

Thromboembolic events (TEE) associated with atrial fibrillation (AF) are highly recurrent and usually severe, causing permanent disability or, even, death. Previous data consistently showed significantly lower TEE in anticoagulated patients. While warfarin, a vitamin K antagonist, is still used worldwide, direct-acting oral anticoagulants (DOACs) have shown noninferiority to warfarin in the prevention of TEE, and represent, to date, the preferred treatment. DOACs present favorable pharmacokinetic, safety and efficacy profiles, especially among vulnerable patients including the elderly, those with renal dysfunction or previous TEE. Yet, regarding specific settings of AF patients it is unclear whether oral anticoagulation therapy is beneficial, or otherwise it is the maintenance of sinus rhythm, mostly achieved through a catheter ablation-based rhythm control strategy, that prevents the causal complications linked to AF. While it is known that low-risk patients [CHA2DS2-VASc 0 (males), or score of 1 (females)] present low ischemic stroke or mortality rates (<1%/year), it remains unclear whether they need any prophylaxis. Furthermore, the appropriate anticoagulation regimen for those individuals requiring cardioversion, either pharmacologic or electric, as well as peri-procedural anticoagulation in patients undergoing trans-catheter ablation that nowadays encompasses different energies, are still a matter of debate. In addition, AF concomitant with other clinical conditions is discussed and, lastly, the choice of prescribing anticoagulation to asymptomatic patients diagnosed with subclinical AF at either wearable or implanted devices. The aim of this review will be to provide an update on current strategies in the above-mentioned settings, and to suggest possible therapeutic options, finally focusing on AF-related cognitive decline.


Assuntos
Fibrilação Atrial , Acidente Vascular Cerebral , Tromboembolia , Masculino , Feminino , Humanos , Idoso , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Varfarina , Anticoagulantes , Tromboembolia/etiologia , Tromboembolia/prevenção & controle , Cardioversão Elétrica/efeitos adversos , Administração Oral , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle
17.
J Clin Med ; 12(5)2023 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-36902735

RESUMO

Myotonic dystrophy type 1 (DM1) is the most common muscular dystrophy in adults. Cardiac involvement is reported in 80% of cases and includes conduction disturbances, arrhythmias, subclinical diastolic and systolic dysfunction in the early stage of the disease; in contrast, severe ventricular systolic dysfunction occurs in the late stage of the disease. Echocardiography is recommended at the time of diagnosis with periodic revaluation in DM1 patients, regardless of the presence or absence of symptoms. Data regarding the echocardiographic findings in DM1 patients are few and conflicting. This narrative review aimed to describe the echocardiographic features of DM1 patients and their prognostic role as predictors of cardiac arrhythmias and sudden death.

18.
Europace ; 25(5)2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-36932709

RESUMO

AIMS: In subcutaneous implantable cardioverter defibrillator (S-ICD) recipients, the UNTOUCHED study demonstrated a very low inappropriate shock rate on programming a conditional zone between 200 and 250 bpm and a shock zone for arrhythmias >250 bpm. The extent to which this programming approach is adopted in clinical practice is still unknown, as is its impact on the rates of inappropriate and appropriate therapies. METHODS AND RESULTS: We assessed ICD programming on implantation and during follow-up in a cohort of 1468 consecutive S-ICD recipients in 56 Italian centres. We also measured the occurrence of inappropriate and appropriate shocks during follow-up. On implantation, the median programmed conditional zone cut-off was set to 200 bpm (IQR: 200-220) and the shock zone cut-off was 230 bpm (IQR: 210-250). During follow-up, the conditional zone cut-off rate was not significantly changed, while the shock zone cut-off was changed in 622 (42%) patients and the median value increased to 250 bpm (IQR: 230-250) (P < 0.001). UNTOUCHED-like programming of detection cut-offs was adopted in 426 (29%) patients immediately after device implantation, and in 714 (49%, P < 0.001) at the last follow-up. UNTOUCHED-like programming was independently associated with fewer inappropriate shocks (hazard ratio 0.50, 95%CI 0.25-0.98, P = 0.044), and had no impact on appropriate and ineffective shocks. CONCLUSIONS: In recent years, S-ICD implanting centres have increasingly programmed high arrhythmia detection cut-off rates, at the time of implantation in the case of new S-ICD recipients, and during follow-up in the case of pre-existing implants. This has contributed significantly to reducing the incidence of inappropriate shocks in clinical practice. Rordorf: Programming of the S-ICD. CLINICAL TRIAL REGISTRATION: URL: http://clinicaltrials.gov/Identifier: NCT02275637.


Assuntos
Desfibriladores Implantáveis , Taquicardia Ventricular , Humanos , Desfibriladores Implantáveis/efeitos adversos , Taquicardia Ventricular/diagnóstico , Seguimentos , Estudos Prospectivos , Cardioversão Elétrica , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia
19.
Heart Rhythm ; 20(7): 984-991, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36906165

RESUMO

BACKGROUND: Conduction system pacing (CSP) using His bundle pacing (HBP) or left bundle branch area pacing (LBBAP) has emerged as an alternative to right ventricular pacing (RVP). Comparative data on the risk of complications between CSP and RVP are lacking. OBJECTIVE: This prospective, multicenter, observational study aimed to compare the long-term risk of device-related complications between CSP and RVP. METHODS: A total of 1029 consecutive patients undergoing pacemaker implantation with CSP (including HBP and LBBAP) or RVP were enrolled. Propensity score matching for baseline characteristics yielded 201 matched pairs. The rate and nature of device-related complications occurring during follow-up were prospectively collected and compared between the 2 groups. RESULTS: During a mean follow-up duration of 18 months, device-related complications were observed in 19 patients: 7 in RVP (3.5%) and 12 in CSP (6.0%) (P = .240). On dividing the matched cohort into 3 groups with similar baseline characteristics according to pacing modality (RVP, n = 201; HBP, n = 128; LBBAP, n = 73), patients with HBP showed a significantly higher rate of device-related complications than did patients with RVP (8.6% vs 3.5%; P = .047) and patients with LBBAP (8.6% vs 1.3%; P = .034). Patients with LBBAP showed a rate of device-related complications similar to that of patients with RVP (1.3% vs 3.5%; P = .358). Most of the complications observed in patients with HBP (63.6%) were lead related. CONCLUSION: Globally, CSP was associated with a risk of complications similar to that of RVP. Considering HBP and LBBAP separately, HBP showed a significantly higher risk of complications than did both RVP and LBBAP whereas LBBAP showed a risk of complications similar to that of RVP.


Assuntos
Fascículo Atrioventricular , Estimulação Cardíaca Artificial , Humanos , Estudos Prospectivos , Pontuação de Propensão , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/métodos , Eletrocardiografia/métodos , Doença do Sistema de Condução Cardíaco , Resultado do Tratamento
20.
Medicina (Kaunas) ; 59(2)2023 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-36837457

RESUMO

Atrial fibrillation (AF) is the most common cardiac arrhythmia associated with an increased thromboembolic risk. The impact of the female sex as an independent risk factor for thromboembolic events in AF is still debated. Background and Objectives: The aim of this review is to evaluate the gender-related differences in cardioembolic risk and response to anticoagulants among AF patients. Materials and Methods: The PubMed database is used to review the reports about gender differences and thromboembolic risk in atrial fibrillation. Results: Non-vitamin K oral anticoagulants (NOACs) represent the gold standard for thromboembolic risk prevention in patients with non-valvular atrial fibrillation (NVAF). Despite a similar rate of stroke and systemic embolism (SE) among men and women in NOACs or vitamin K antagonists (VKAs) treatment, the use of NOACs in AF women is associated with a lower risk of intracranial bleeding, major bleeding, and all-cause mortality than in men. Conclusions: The female sex can be defined as a stroke risk modifier rather than a stroke risk factor since it mainly increases the thromboembolic risk in the presence of other risk factors. Further studies about the efficacy and safety profile of NOACs according to sex are needed to support clinicians in performing the most appropriate and tailored anticoagulant therapy, either in male or female AF patients.


Assuntos
Fibrilação Atrial , Acidente Vascular Cerebral , Tromboembolia , Feminino , Humanos , Masculino , Anticoagulantes/uso terapêutico , Fibrilação Atrial/complicações , Administração Oral , Fatores Sexuais , Acidente Vascular Cerebral/complicações , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...