1.
Int J Hyperthermia ; 41(1): 2321980, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38616245

RESUMO

BACKGROUND: A method for periprocedural contrast agent-free visualization of uterine fibroid perfusion could potentially shorten magnetic resonance-guided high intensity focused ultrasound (MR-HIFU) treatment times and improve outcomes. Our goal was to test feasibility of perfusion fraction mapping by intravoxel incoherent motion (IVIM) modeling using diffusion-weighted MRI as method for visual evaluation of MR-HIFU treatment progression. METHODS: Conventional and T2-corrected IVIM-derived perfusion fraction maps were retrospectively calculated by applying two fitting methods to diffusion-weighted MRI data (b = 0, 50, 100, 200, 400, 600 and 800 s/mm2 at 1.5 T) from forty-four premenopausal women who underwent MR-HIFU ablation treatment of uterine fibroids. Contrast in perfusion fraction maps between areas with low perfusion fraction and surrounding tissue in the target uterine fibroid immediately following MR-HIFU treatment was evaluated. Additionally, the Dice similarity coefficient (DSC) was calculated between delineated areas with low IVIM-derived perfusion fraction and hypoperfusion based on CE-T1w. RESULTS: Average perfusion fraction ranged between 0.068 and 0.083 in areas with low perfusion fraction based on visual assessment, and between 0.256 and 0.335 in surrounding tissues (all p < 0.001). DSCs ranged from 0.714 to 0.734 between areas with low perfusion fraction and the CE-T1w derived non-perfused areas, with excellent intraobserver reliability of the delineated areas (ICC 0.97). CONCLUSION: The MR-HIFU treatment effect in uterine fibroids can be visualized using IVIM perfusion fraction mapping, in moderate concordance with contrast enhanced MRI. IVIM perfusion fraction mapping has therefore the potential to serve as a contrast agent-free imaging method to visualize the MR-HIFU treatment progression in uterine fibroids.


Assuntos
Leiomioma , Imageamento por Ressonância Magnética , Feminino , Humanos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Perfusão , Leiomioma/diagnóstico por imagem , Leiomioma/cirurgia
2.
Insights Imaging ; 15(1): 83, 2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38517607

RESUMO

OBJECTIVES: To assess the environmental impact of the non-invasive Magnetic Resonance image-guided High-Intensity Focused Ultrasound (MR-HIFU) treatment of uterine fibroids, we aimed to perform a full Life Cycle Assessment (LCA). However, as a full LCA was not feasible at this time, we evaluated the CO2 (carbon dioxide) emission from the MRI scanner, MR-HIFU device, and the medication used, and analyzed solid waste produced during treatment. METHODS: Our functional unit was one uterine fibroid MR-HIFU treatment. The moment the patient entered the day care-unit until she left, defined our boundaries of investigation. We retrospectively collected data from 25 treatments to assess the CO2 emission based on the energy used by the MRI scanner and MR-HIFU device and the amount and type of medication administered. Solid waste was prospectively collected from five treatments. RESULTS: During an MR-HIFU treatment, the MRI scanner and MR-HIFU device produced 33.2 ± 8.7 kg of CO2 emission and medication administered 0.13 ± 0.04 kg. A uterine fibroid MR-HIFU treatment produced 1.2 kg (range 1.1-1.4) of solid waste. CONCLUSIONS: Environmental impact should ideally be analyzed for all (new) medical treatments. By assessing part of the CO2 emission and solid waste produced, we have taken the first steps towards analyzing the total environmental impact of the MR-HIFU treatment of uterine fibroids. These data can contribute to future studies comparing the results of MR-HIFU LCAs with LCAs of other uterine fibroid therapies. CRITICAL RELEVANCE STATEMENT: In addition to (cost-) effectiveness, the environmental impact of new treatments should be assessed. We took the first steps towards analyzing the total environmental impact of uterine fibroid MR-HIFU. KEY POINTS: • Life Cycle Assessments (LCAs) should be performed for all (new) medical treatments. • We took the first steps towards analyzing the environmental impact of uterine fibroid MR-HIFU. • Energy used by the MRI scanner and MR-HIFU device corresponded to 33.2 ± 8.7 kg of CO2 emission.

3.
Eur J Obstet Gynecol Reprod Biol ; 297: 15-23, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38555851

RESUMO

In this review, a systematic literature search on the effectiveness and complication rates of ultrasound-guided and magnetic resonance-guided high-intensity focused ultrasound (USg-/MRgHIFU) for abdominal wall endometriosis (AWE) was conducted in six databases in May/June 2023. Original articles of (non)randomized trials, cohort studies, case-control studies and case series published in peer-reviewed journals were included. Of the included studies the level of evidence (LoE) and methodological quality using the ROBINS-I and IHE-QAT was assessed. Primary outcomes were non-perfused volume ratio (NPV%), lesion size, pain scores, side effects and complication rates according to Society of Interventional Radiology (SIR) guidelines. Secondary outcomes were recurrence and re-intervention rates. Seven cohort studies (one of good methodological quality) (LoE 3) on USgHIFU were included (n = 212, AWE lesions = 240-245). Six months after USgHIFU treatment, pain scores were reduced with 3.3-5.2 points (baseline: 5.1-6.8, n = 135). Self-limiting side effects were pain (85.7 % (114/133)) and swelling (34.6 % (46/133)) in the treatment area. Complications occurred in 17.7 % (32/181), all of which were minor. Recurrence occurred in 12.8 % (11/86). Three of these seven cohort studies compared USgHIFU (n = 61) with surgical excision (n = 74). Pooled results showed no significant differences in pain scores, complications (resp. 26.3 % (10/38) vs. 32.6 % (15/46) (p = 0.53)) and recurrences (resp. 4.9 % (3/61) vs. 5.4 % (4/74) (p = 0.90)). This systematic review suggests that HIFU is an effective and safe treatment option for AWE. USgHIFU treatment led to reduced pain scores and lesion size, was free of major complications and had a pooled recurrence rate of 12.8 %. Compared to surgical excision pooled results showed no significant differences in pain scores, complications and recurrences after USgHIFU. However, many of the included studies had limitations in their methodological quality and therefore the results should be interpreted with caution. Well-structured high-quality randomized controlled trials comparing HIFU to standard care should be conducted to provide more conclusive evidence.


Assuntos
Parede Abdominal , Endometriose , Ablação por Ultrassom Focalizado de Alta Intensidade , Humanos , Feminino , Endometriose/cirurgia , Endometriose/terapia , Parede Abdominal/cirurgia , Ablação por Ultrassom Focalizado de Alta Intensidade/efeitos adversos , Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Resultado do Tratamento , Ultrassonografia de Intervenção
4.
Eur Radiol Exp ; 8(1): 31, 2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-38480603

RESUMO

BACKGROUND: To compare image quality, metal artifacts, and diagnostic confidence of conventional computed tomography (CT) images of unilateral total hip arthroplasty patients (THA) with deep learning-based metal artifact reduction (DL-MAR) to conventional CT and 130-keV monoenergetic images with and without orthopedic metal artifact reduction (O-MAR). METHODS: Conventional CT and 130-keV monoenergetic images with and without O-MAR and DL-MAR images of 28 unilateral THA patients were reconstructed. Image quality, metal artifacts, and diagnostic confidence in bone, pelvic organs, and soft tissue adjacent to the prosthesis were jointly scored by two experienced musculoskeletal radiologists. Contrast-to-noise ratios (CNR) between bladder and fat and muscle and fat were measured. Wilcoxon signed-rank tests with Holm-Bonferroni correction were used. RESULTS: Significantly higher image quality, higher diagnostic confidence, and less severe metal artifacts were observed on DL-MAR and images with O-MAR compared to images without O-MAR (p < 0.001 for all comparisons). Higher image quality, higher diagnostic confidence for bone and soft tissue adjacent to the prosthesis, and less severe metal artifacts were observed on DL-MAR when compared to conventional images and 130-keV monoenergetic images with O-MAR (p ≤ 0.014). CNRs were higher for DL-MAR and images with O-MAR compared to images without O-MAR (p < 0.001). Higher CNRs were observed on DL-MAR images compared to conventional images and 130-keV monoenergetic images with O-MAR (p ≤ 0.010). CONCLUSIONS: DL-MAR showed higher image quality, diagnostic confidence, and superior metal artifact reduction compared to conventional CT images and 130-keV monoenergetic images with and without O-MAR in unilateral THA patients. RELEVANCE STATEMENT: DL-MAR resulted into improved image quality, stronger reduction of metal artifacts, and improved diagnostic confidence compared to conventional and virtual monoenergetic images with and without metal artifact reduction, bringing DL-based metal artifact reduction closer to clinical application. KEY POINTS: • Metal artifacts introduced by total hip arthroplasty hamper radiologic assessment on CT. • A deep-learning algorithm (DL-MAR) was compared to dual-layer CT images with O-MAR. • DL-MAR showed best image quality and diagnostic confidence. • Highest contrast-to-noise ratios were observed on the DL-MAR images.


Assuntos
Artroplastia de Quadril , Aprendizado Profundo , Humanos , Tomografia Computadorizada por Raios X/métodos , Artefatos , Algoritmos
5.
Eur J Radiol ; 173: 111361, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38401407

RESUMO

PURPOSE: To evaluate the diagnostic performance and generalizability of the winning DL algorithm of the RSNA 2020 PE detection challenge to a local population using CTPA data from two hospitals. MATERIALS AND METHODS: Consecutive CTPA images from patients referred for suspected PE were retrospectively analysed. The winning RSNA 2020 DL algorithm was retrained on the RSNA-STR Pulmonary Embolism CT (RSPECT) dataset. The algorithm was tested in hospital A on multidetector CT (MDCT) images of 238 patients and in hospital B on spectral detector CT (SDCT) and virtual monochromatic images (VMI) of 114 patients. The output of the DL algorithm was compared with a reference standard, which included a consensus reading by at least two experienced cardiothoracic radiologists for both hospitals. Areas under the receiver operating characteristic curve (AUCs) were calculated. Sensitivity and specificity were determined using the maximum Youden index. RESULTS: According to the reference standard, PE was present in 73 patients (30.7%) in hospital A and 33 patients (29.0%) in hospital B. For the DL algorithm the AUC was 0.96 (95% CI 0.92-0.98) in hospital A, 0.89 (95% CI 0.81-0.94) for conventional reconstruction in hospital B and 0.87 (95% CI 0.80-0.93) for VMI. CONCLUSION: The RSNA 2020 pulmonary embolism detection on CTPA challenge winning DL algorithm, retrained on the RSPECT dataset, showed high diagnostic accuracy on MDCT images. A somewhat lower performance was observed on SDCT images, which suggest additional training on novel CT technology may improve generalizability of this DL algorithm.


Assuntos
Aprendizado Profundo , Embolia Pulmonar , Humanos , Angiografia/métodos , Estudos Retrospectivos , Embolia Pulmonar/diagnóstico por imagem , Sensibilidade e Especificidade
6.
Pediatr Res ; 2024 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-38368497

RESUMO

OBJECTIVE: Concerns have been raised about the effect of skin color on the accuracy of transcutaneous bilirubin (TcB) measurements, a widely used method for hyperbilirubinemia diagnosis in newborns. Literature is inconclusive, with both reported under- and overestimations of the TcB with increasing skin pigmentation. Therefore, the influence of skin color on TcB measurements was systematically evaluated in a controlled, in vitro setting. METHODS: A bilirubin meter (JM-105) was evaluated on layered phantoms that mimic neonatal skin with varying dermal bilirubin concentrations (0-250 µmol/L) and varying epidermal melanosome volume fractions (0-40%; light-dark skin color). RESULTS: TcB measurements were influenced by skin pigmentation. Larger mimicked melanosome volume fractions and higher bilirubin levels led to larger underestimations of the measured TcB, compared to an unpigmented epidermis. In the in vitro setting of this study, these underestimations amounted to 26-132 µmol/L at a TcB level of 250 µmol/L. CONCLUSION: This in vitro study provides insight into the effect of skin color on TcB measurements: the TcB is underestimated as skin pigmentation increases and this effect becomes more pronounced at higher bilirubin levels. Our results highlight the need for improved TcB meter design and cautious interpretation of TcB readings on newborns with dark skin. IMPACT: Key message: Skin color influences transcutaneous bilirubin measurements: the darker the skin, the larger the underestimation. What this study adds to existing literature: Existing literature is inconclusive regarding the influence of skin color on transcutaneous bilirubin measurements. This study systematically evaluates and clarifies the influence of skin color on transcutaneous bilirubin measurements in a controlled, in vitro setting. IMPACT: This study aids to better interpret the measured TcB level in patients with varying skin colors, and is particularly important when using TcB meters on patients with dark skin colors.

7.
J Ultrasound ; 2024 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-38281292

RESUMO

PURPOSE: Despite progressive implementation of image-guided point-shear wave elastography (pSWE) in guidelines as an alternative to transient elastography for the staging of fibrotic liver disease, pSWE is not widely adopted in clinical workflow. More information on reliability and validity of pSWE systems is needed. Therefore, we performed a phantom study to evaluate the validity and reliability of pSWE with ultrasound systems. METHODS: Validity and reliability of pSWE measurements from three ultrasound systems were evaluated. Measurements were performed on an elasticity phantom with reference elasticities of 7 ± 1 (low) (median ± interquartile range (IQR)), 14 ± 2 (medium) and 26 ± 3 (high) kPa. Measurements were repeated in tenfold for each reference at 2, 3 and 4 cm depth. Results were considered valid when median elasticity ± IQR was between the uncertainty limits (IQR) for each reference elasticity value and reliable when IQR/median < 0.30. RESULTS: pSWE with the systems provided valid results for all reference elasticities and focal depths, except for overestimation of high reference elasticity at 2 and 4 cm depth for one system (41.5 ± 4.3 and 39.0 ± 1.2 kPa, respectively). Measurements were reliable with a maximum IQR/median of 0.13, well below the guideline of IQR/median < 0.30. DISCUSSION: The results support the use of pSWE as an alternative to invasive or non-image guided noninvasive techniques for liver fibrotic staging. CONCLUSIONS: pSWE with ultrasound systems from different vendors is valid and reliable and can therefore be implemented to optimize clinical workflow by performing imaging and elastography simultaneously.

8.
Eur Radiol ; 2024 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-38206401

RESUMO

OBJECTIVES: To compare diagnostic accuracy of a deep learning artificial intelligence (AI) for cervical spine (C-spine) fracture detection on CT to attending radiologists and assess which undetected fractures were injuries in need of stabilising therapy (IST). METHODS: This single-centre, retrospective diagnostic accuracy study included consecutive patients (age ≥18 years; 2007-2014) screened for C-spine fractures with CT. To validate ground truth, one radiologist and three neurosurgeons independently examined scans positive for fracture. Negative scans were followed up until 2022 through patient files and two radiologists reviewed negative scans that were flagged positive by AI. The neurosurgeons determined which fractures were ISTs. Diagnostic accuracy of AI and attending radiologists (index tests) were compared using McNemar. RESULTS: Of the 2368 scans (median age, 48, interquartile range 30-65; 1441 men) analysed, 221 (9.3%) scans contained C-spine fractures with 133 IST. AI detected 158/221 scans with fractures (sensitivity 71.5%, 95% CI 65.5-77.4%) and 2118/2147 scans without fractures (specificity 98.6%, 95% CI 98.2-99.1). In comparison, attending radiologists detected 195/221 scans with fractures (sensitivity 88.2%, 95% CI 84.0-92.5%, p < 0.001) and 2130/2147 scans without fracture (specificity 99.2%, 95% CI 98.8-99.6, p = 0.07). Of the fractures undetected by AI 30/63 were ISTs versus 4/26 for radiologists. AI detected 22/26 fractures undetected by the radiologists, including 3/4 undetected ISTs. CONCLUSION: Compared to attending radiologists, the artificial intelligence has a lower sensitivity and a higher miss rate of fractures in need of stabilising therapy; however, it detected most fractures undetected by the radiologists, including fractures in need of stabilising therapy. Clinical relevance statement The artificial intelligence algorithm missed more cervical spine fractures on CT than attending radiologists, but detected 84.6% of fractures undetected by radiologists, including fractures in need of stabilising therapy. KEY POINTS: The impact of artificial intelligence for cervical spine fracture detection on CT on fracture management is unknown. The algorithm detected less fractures than attending radiologists, but detected most fractures undetected by the radiologists including almost all in need of stabilising therapy. The artificial intelligence algorithm shows potential as a concurrent reader.

9.
Eur Radiol ; 34(1): 367-373, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37532902

RESUMO

OBJECTIVES: The purpose of this study was to evaluate the incremental value of artificial intelligence (AI) compared to the diagnostic accuracy of radiologists alone in detecting incidental acute pulmonary embolism (PE) on routine portal venous contrast-enhanced chest computed tomography (CT). METHODS: CTs of 3089 consecutive patients referred to the radiology department for a routine contrast-enhanced chest CT between 27-5-2020 and 31-12-2020, were retrospectively analysed by a CE-certified and FDA-approved AI algorithm. The diagnostic performance of the AI was compared to the initial report. To determine the reference standard, discordant findings were independently evaluated by two readers. In case of disagreement, another experienced cardiothoracic radiologist with knowledge of the initial report and the AI output adjudicated. RESULTS: The prevalence of acute incidental PE in the reference standard was 2.2% (67 of 3089 patients). In 25 cases, AI detected initially unreported PE. This included three cases concerning central/lobar PE. Sensitivity of the AI algorithm was significantly higher than the outcome of the initial report (respectively 95.5% vs. 62.7%, p < 0.001), whereas specificity was very high for both (respectively 99.6% vs 99.9%, p = 0.012). The AI algorithm only showed a slightly higher amount of false-positive findings (11 vs. 2), resulting in a significantly lower PPV (85.3% vs. 95.5%, p = 0.047). CONCLUSION: The AI algorithm showed high diagnostic accuracy in diagnosing incidental PE, detecting an additional 25 cases of initially unreported PE, accounting for 37.3% of all positive cases. CLINICAL RELEVANCE STATEMENT: Radiologist support from AI algorithms in daily practice can prevent missed incidental acute PE on routine chest CT, without a high burden of false-positive cases. KEY POINTS: • Incidental pulmonary embolism is often missed by radiologists in non-diagnostic scans with suboptimal contrast opacification within the pulmonary trunk. • An artificial intelligence algorithm showed higher sensitivity detecting incidental pulmonary embolism on routine portal venous chest CT compared to the initial report. • Implementation of artificial intelligence support in routine daily practice will reduce the number of missed incidental pulmonary embolism.


Assuntos
Inteligência Artificial , Embolia Pulmonar , Humanos , Estudos Retrospectivos , Embolia Pulmonar/diagnóstico por imagem , Embolia Pulmonar/epidemiologia , Tomografia Computadorizada por Raios X , Algoritmos
10.
Eur Radiol ; 34(1): 384-390, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37542651

RESUMO

OBJECTIVES: Virtual monochromatic images (VMI) are increasingly used in clinical practice as they improve contrast-to-noise ratio. However, due to their different appearances, the performance of artificial intelligence (AI) trained on conventional CT images may worsen. The goal of this study was to assess the performance of an established AI algorithm trained on conventional polychromatic computed tomography (CT) images (CPI) to detect pulmonary embolism (PE) on VMI. METHODS: Paired 60 kiloelectron volt (keV) VMI and CPI of 114 consecutive patients suspected of PE, obtained with a detector-based spectral CT scanner, were retrospectively analyzed by an established AI algorithm. The CT pulmonary angiography (CTPA) were classified as positive or negative for PE on a per-patient level. The reference standard was established using a comprehensive method that combined the evaluation of the attending radiologist and three experienced cardiothoracic radiologists aided by two different detection tools. Sensitivity, specificity, positive and negative predictive values and likelihood ratios of the algorithm on VMI and CPI were compared. RESULTS: The prevalence of PE according to the reference standard was 35.1% (40 patients). None of the diagnostic accuracy measures of the algorithm showed a significant difference between CPI and VMI. Sensitivity was 77.5% (95% confidence interval (CI) 64.6-90.4%) and 85.0% (73.9-96.1%) (p = 0.08) on CPI and VMI respectively and specificity 96.0% (91.4-100.0%) and 94.6% (89.4-99.7%) (p = 0.32). CONCLUSIONS: Diagnostic performance of the AI algorithm that was trained on CPI did not drop on VMI, which is reassuring for its use in clinical practice. CLINICAL RELEVANCE STATEMENT: A commercially available AI algorithm, trained on conventional polychromatic CTPA, could be safely used on virtual monochromatic images. This supports the sustainability of AI-aided detection of PE on CT despite ongoing technological advances in medical imaging, although monitoring in daily practice will remain important. KEY POINTS: • Diagnostic accuracy of an AI algorithm trained on conventional polychromatic images to detect PE did not drop on virtual monochromatic images. • Our results are reassuring as innovations in hardware and reconstruction in CT are continuing, whilst commercial AI algorithms that are trained on older generation data enter healthcare.


Assuntos
Inteligência Artificial , Embolia Pulmonar , Humanos , Razão Sinal-Ruído , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Angiografia por Tomografia Computadorizada/métodos , Algoritmos , Embolia Pulmonar/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
14.
Neurourol Urodyn ; 42(8): 1822-1838, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37498009

RESUMO

OBJECTIVE: To review the effect of bladder outlet procedures on urodynamic outcomes and symptom scores in males with detrusor underactivity (DU) or acontractile detrusors (AD). MATERIALS AND METHODS: We performed a systematic review and meta-analysis of research publications derived from PubMed, Embase, Web of Science, and Ovid Medline to identify clinical studies of adult men with non-neurogenic DU or AD who underwent any bladder outlet procedure. Outcomes comprised the detrusor pressure at maximum flow (Pdet Qmax ), maximum flow rate (Qmax ), international prostate symptom score (IPSS), and quality of life (QoL). This study is registered under PROSPERO CRD42020215832. RESULTS: We included 13 studies of bladder outlet procedures, of which 6 reported decreased and 7 reported improved Pdet Qmax after the procedure. Meta-analysis revealed an increase in the pooled mean Pdet Qmax of 5.99 cmH2 0 after surgery (95% CI: 0.59-11.40; p = 0.03; I2 95%). Notably, the Pdet Qmax improved in all subgroups with a preoperative bladder contractility index (BCI) <50 and decreased in all subgroups with a BCI ≥50. All studies reported an improved Qmax after surgery, with a pooled mean difference of 5.87 mL/s (95% CI: 4.25-7.49; I2 93%). Only three studies reported QoL, but pooling suggested significant improvements after surgery (mean, -2.41 points; 95% CI: -2.81 to -2.01; p = 0.007). All seven studies reporting IPSS demonstrated improvement (mean, -12.82; 95% CI: -14.76 to -10.88; p < 0.001). CONCLUSIONS: This review shows that Pdet Qmax and Qmax increases after surgical bladder outlet procedures in men with DU and AD. Bladder outlet procedures should be discussed as part of the shared decision-making process for this group. The evidence was of low to very low certainty.


Assuntos
Obstrução do Colo da Bexiga Urinária , Bexiga Inativa , Masculino , Adulto , Humanos , Bexiga Urinária/cirurgia , Bexiga Inativa/cirurgia , Qualidade de Vida , Urodinâmica , Obstrução do Colo da Bexiga Urinária/cirurgia
15.
Insights Imaging ; 14(1): 102, 2023 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-37278961

RESUMO

PURPOSE: To generate and extend the evidence on the clinical validity of an artificial intelligence (AI) algorithm to detect acute pulmonary embolism (PE) on CT pulmonary angiography (CTPA) of patients suspected of PE and to evaluate the possibility of reducing the risk of missed findings in clinical practice with AI-assisted reporting. METHODS: Consecutive CTPA scan data of 3316 patients referred because of suspected PE between 24-2-2018 and 31-12-2020 were retrospectively analysed by a CE-certified and FDA-approved AI algorithm. The output of the AI was compared with the attending radiologists' report. To define the reference standard, discordant findings were independently evaluated by two readers. In case of disagreement, an experienced cardiothoracic radiologist adjudicated. RESULTS: According to the reference standard, PE was present in 717 patients (21.6%). PE was missed by the AI in 23 patients, while the attending radiologist missed 60 PE. The AI detected 2 false positives and the attending radiologist 9. The sensitivity for the detection of PE by the AI algorithm was significantly higher compared to the radiology report (96.8% vs. 91.6%, p < 0.001). Specificity of the AI was also significantly higher (99.9% vs. 99.7%, p = 0.035). NPV and PPV of the AI were also significantly higher than the radiology report. CONCLUSION: The AI algorithm showed a significantly higher diagnostic accuracy for the detection of PE on CTPA compared to the report of the attending radiologist. This finding indicates that missed positive findings could be prevented with the implementation of AI-assisted reporting in daily clinical practice. CRITICAL RELEVANCE STATEMENT: Missed positive findings on CTPA of patients suspected of pulmonary embolism can be prevented with the implementation of AI-assisted care. KEY POINTS: The AI algorithm showed excellent diagnostic accuracy detecting PE on CTPA. Accuracy of the AI was significantly higher compared to the attending radiologist. Highest diagnostic accuracy can likely be achieved by radiologists supported by AI. Our results indicate that implementation of AI-assisted reporting could reduce the number of missed positive findings.

16.
Eur J Radiol ; 163: 110844, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37119708

RESUMO

PURPOSE: To develop a deep learning-based metal artifact reduction technique (dl-MAR) and quantitatively compare metal artifacts on dl-MAR-corrected CT-images, orthopedic metal artifact reduction (O-MAR)-corrected CT-images and uncorrected CT-images after sacroiliac (SI) joint fusion. METHODS: dl-MAR was trained on CT-images with simulated metal artifacts. Pre-surgery CT-images and uncorrected, O-MAR-corrected and dl-MAR-corrected post-surgery CT-images of twenty-five patients undergoing SI joint fusion were retrospectively obtained. Image registration was applied to align pre-surgery with post-surgery CT-images within each patient, allowing placement of regions of interest (ROIs) on the same anatomical locations. Six ROIs were placed on the metal implant and the contralateral side in bone lateral of the SI joint, the gluteus medius muscle and the iliacus muscle. Metal artifacts were quantified as the difference in Hounsfield units (HU) between pre- and post-surgery CT-values within the ROIs on the uncorrected, O-MAR-corrected and dl-MAR-corrected images. Noise was quantified as standard deviation in HU within the ROIs. Metal artifacts and noise in the post-surgery CT-images were compared using linear multilevel regression models. RESULTS: Metal artifacts were significantly reduced by O-MAR and dl-MAR in bone (p < 0.001), contralateral bone (O-MAR: p = 0.009; dl-MAR: p < 0.001), gluteus medius (p < 0.001), contralateral gluteus medius (p < 0.001), iliacus (p < 0.001) and contralateral iliacus (O-MAR: p = 0.024; dl-MAR: p < 0.001) compared to uncorrected images. Images corrected with dl-MAR resulted in stronger artifact reduction than images corrected with O-MAR in contralateral bone (p < 0.001), gluteus medius (p = 0.006), contralateral gluteus medius (p < 0.001), iliacus (p = 0.017), and contralateral iliacus (p < 0.001). Noise was reduced by O-MAR in bone (p = 0.009) and gluteus medius (p < 0.001) while noise was reduced by dl-MAR in all ROIs (p < 0.001) in comparison to uncorrected images. CONCLUSION: dl-MAR showed superior metal artifact reduction compared to O-MAR in CT-images with SI joint fusion implants.


Assuntos
Aprendizado Profundo , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Artefatos , Articulação Sacroilíaca/diagnóstico por imagem , Articulação Sacroilíaca/cirurgia , Estudos Retrospectivos , Algoritmos
17.
Artigo em Inglês | MEDLINE | ID: mdl-36673840

RESUMO

Magnetic resonance imaging-guided high-intensity focused ultrasound (MR-HIFU) is an innovative treatment for patients with painful bone metastases. The adoption of MR-HIFU will be influenced by several factors beyond its effectiveness. To identify contextual factors affecting the adoption of MR-HIFU, we conducted a group concept mapping (GCM) study in four European countries. The GCM was conducted in two phases. First, the participants brainstormed statements guided by the focus prompt "One factor that may influence the uptake of MR-HIFU in clinical practice is...". Second, the participants sorted statements into categories and rated the statements according to their importance and changeability. To generate a concept map, multidimensional scaling and cluster analysis were conducted, and average ratings for each (cluster of) factors were calculated. Forty-five participants contributed to phase I and/or II (56% overall participation rate). The resulting concept map comprises 49 factors, organized in 12 clusters: "competitive treatments", "physicians' attitudes", "alignment of resources", "logistics and workflow", "technical disadvantages", "radiotherapy as first-line therapy", "aggregating knowledge and improving awareness", "clinical effectiveness", "patients' preferences", "reimbursement", "cost-effectiveness" and "hospital costs". The factors identified echo those from the literature, but their relevance and interrelationship are case-specific. Besides evidence on clinical effectiveness, contextual factors from 10 other clusters should be addressed to support adoption of MR-HIFU.


Assuntos
Ablação por Ultrassom Focalizado de Alta Intensidade , Humanos , Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Imageamento por Ressonância Magnética/métodos , Dor , Resultado do Tratamento , Espectroscopia de Ressonância Magnética
18.
BMC Musculoskelet Disord ; 24(1): 16, 2023 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-36611153

RESUMO

BACKGROUND: This systematic review and meta-analysis examined the effectiveness of orthoses for flexible flatfeet in terms of patient-reported outcomes in children and adults. METHODS: EMBASE, Medline (OvidSP), Web-of-Science, Scopus, CINAHL, Cochrane Central Register of Controlled Clinical Trials, i.e., Cochrane Central and Pubmed were searched to identify relevant studies since their inception up to February 2021. We included randomized controlled trials (RCT) and prospective studies in which patient reported outcomes at baseline and follow-up in an orthoses group were compared with a no orthoses or sham sole group. Methodological quality of the studies was assessed using the Revised Cochrane risk-of-bias tool for randomized trials (RoB 2) and the Risk Of Bias In Non-Randomized Studies of Interventions (ROBINS-I). A meta-analysis was performed where there were multiple studies with the same outcome measures, which was the case for the Visual Analogue Scale (VAS) for pain in adults. RESULTS: In total nine studies were included: four RCT in children (N = 353) and four RCT and one prospective study in adults (N = 268) were included. There was considerable heterogeneity between studies. A meta-analysis demonstrated that pain reduction between baseline and follow-up was significantly larger in the orthoses (N = 167) than in the control groups in adults (N = 157; - 4.76, 95% CI [- 9.46, - 0.06], p0.05). CONCLUSION: Due to heterogeneity in study designs, we cannot conclude that foot orthoses are useful for flexible flatfoot in children and adults. However, based on the meta-analysis orthoses might be useful in decreasing pain in adults. The authors did not receive support from any organization for the submitted work.


Assuntos
Pé Chato , Órtoses do Pé , Criança , Adulto , Humanos , Pé Chato/terapia , Dor , Medidas de Resultados Relatados pelo Paciente , Viés
19.
Pediatr Res ; 94(1): 239-245, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36443401

RESUMO

BACKGROUND: The cephalocaudal progression (CCP) of neonatal jaundice is a well-known phenomenon, but quantitative information on CCP in preterm infants is absent. In this study, CCP was quantified in preterm infants as a function of postnatal age and body location. METHODS: 5.693 transcutaneous bilirubin (TcB) measurements were performed in 101 preterm infants from birth until postnatal day seven at five body locations (forehead, sternum, hipbone, tibia, ankle). Multi-level linear regression analysis was performed to evaluate the CCP as a function of body location and postnatal age. TcB measurements at all body locations and postnatal days were compared to total serum bilirubin (TSB) levels (N = 1.113). RESULTS: The overall average change in ratio of TcB compared to forehead was for sternum +0.04 [95% CI -0.02;0.09]; hipbone +0.05 [0.00;0.01]; tibia -0.33 [-0.38;-0.27] and ankle -0.62 [-0.68;-0.57]. No effect modification of CCP by sex, gestational age, birthweight, phototherapy, and TSB was found. The TcB maximally underestimated the TSB at the ankle -79.5 µmol [-0.1;159.2]. CONCLUSIONS: CCP is present in preterm infants and is relatively stable over time. Since TcB measurements on the tibia and ankle underestimate TSB significantly, we advise to use only measurement locations cephalic from the tibia; i.e., hipbone, sternum, and forehead. IMPACT: Cephalocaudal progression (CCP) of jaundice in preterm infants, assessed by transcutaneous bilirubin (TcB) measurements, is substantial and rather stable over postnatal day 0 to 7. To the best of our knowledge, this study is the first to investigate CCP of jaundice in preterm infants as a function of postnatal age in preterm infants. Our results demonstrate that TcB measurements at the tibia and ankle differ from the TSB beyond the clinically used TcB safety margins. We advise to perform TcB measurements only at locations cephalic from the tibia; i.e., hipbone, forehead, and sternum.


Assuntos
Icterícia Neonatal , Icterícia , Lactente , Feminino , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Icterícia Neonatal/diagnóstico , Icterícia Neonatal/terapia , Peso ao Nascer , Bilirrubina , Triagem Neonatal/métodos
20.
Eur Radiol ; 33(6): 4178-4188, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36472702

RESUMO

OBJECTIVES: No method is available to determine the non-perfused volume (NPV) repeatedly during magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) ablations of uterine fibroids, as repeated acquisition of contrast-enhanced T1-weighted (CE-T1w) scans is inhibited by safety concerns. The objective of this study was to develop and test a deep learning-based method for translation of diffusion-weighted imaging (DWI) into synthetic CE-T1w scans, for monitoring MR-HIFU treatment progression. METHODS: The algorithm was retrospectively trained and validated on data from 33 and 20 patients respectively who underwent an MR-HIFU treatment of uterine fibroids between June 2017 and January 2019. Postablation synthetic CE-T1w images were generated by a deep learning network trained on paired DWI and reference CE-T1w scans acquired during the treatment procedure. Quantitative analysis included calculation of the Dice coefficient of NPVs delineated on synthetic and reference CE-T1w scans. Four MR-HIFU radiologists assessed the outcome of MR-HIFU treatments and NPV ratio based on the synthetic and reference CE-T1w scans. RESULTS: Dice coefficient of NPVs was 71% (± 22%). The mean difference in NPV ratio was 1.4% (± 22%) and not statistically significant (p = 0.79). Absolute agreement of the radiologists on technical treatment success on synthetic and reference CE-T1w scans was 83%. NPV ratio estimations on synthetic and reference CE-T1w scans were not significantly different (p = 0.27). CONCLUSIONS: Deep learning-based synthetic CE-T1w scans derived from intraprocedural DWI allow gadolinium-free visualization of the predicted NPV, and can potentially be used for repeated gadolinium-free monitoring of treatment progression during MR-HIFU therapy for uterine fibroids. KEY POINTS: • Synthetic CE-T1w scans can be derived from diffusion-weighted imaging using deep learning. • Synthetic CE-T1w scans may be used for visualization of the NPV without using a contrast agent directly after MR-HIFU ablations of uterine fibroids.


Assuntos
Aprendizado Profundo , Ablação por Ultrassom Focalizado de Alta Intensidade , Leiomioma , Neoplasias Uterinas , Feminino , Humanos , Neoplasias Uterinas/diagnóstico por imagem , Neoplasias Uterinas/cirurgia , Estudos Retrospectivos , Leiomioma/diagnóstico por imagem , Leiomioma/cirurgia , Imageamento por Ressonância Magnética/métodos , Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Resultado do Tratamento