1.
Sci Rep ; 13(1): 9560, 2023 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-37308526

RESUMO

Dielectrophoresis is an electric field-based technique for moving neutral particles through a fluid. When used for particle separation, dielectrophoresis has many advantages compared to other methods, like providing label-free operation with greater control of the separation forces. In this paper, we design, build, and test a low-voltage dielectrophoretic device using a 3D printing approach. This lab-on-a-chip device fits on a microscope glass slide and incorporates microfluidic channels for particle separation. First, we use multiphysics simulations to evaluate the separation efficiency of the prospective device and guide the design process. Second, we fabricate the device in PDMS (polydimethylsiloxane) by using 3D-printed moulds that contain patterns of the channels and electrodes. The imprint of the electrodes is then filled with silver conductive paint, making a 9-pole comb electrode. Lastly, we evaluate the separation efficiency of our device by introducing a mixture of 3 µm and 10 µm polystyrene particles and tracking their progression. Our device is able to efficiently separate these particles when the electrodes are energized with ±12 V at 75 kHz. Overall, our method allows the fabrication of cheap and effective dielectrophoretic microfluidic devices using commercial off-the-shelf equipment.

2.
Res Microbiol ; 174(6): 104060, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37068697

RESUMO

Spore-forming pathogenic bacteria are adapted for adhering to surfaces, and their endospores can tolerate strong chemicals making decontamination difficult. Understanding the physico-chemical properties of bacteria and spores is therefore essential in developing antiadhesive surfaces and disinfection techniques. However, measuring physico-chemical properties in bulk does not show the heterogeneity between cells. Characterizing bacteria on a single-cell level can thereby provide mechanistic clues usually hidden in bulk measurements. This paper shows how optical tweezers can be applied to characterize single bacteria and spores, and how physico-chemical properties related to adhesion, fluid dynamics, biochemistry, and metabolic activity can be assessed.


Assuntos
Pinças Ópticas , Análise Espectral Raman , Análise Espectral Raman/métodos , Esporos , Esporos Bacterianos , Bactérias
3.
Biosens Bioelectron ; 231: 115284, 2023 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-37031508

RESUMO

Bacterial spores are problematic in agriculture, the food industry, and healthcare, with the fallout costs from spore-related contamination being very high. Spores are difficult to detect since they are resistant to many of the bacterial disruption techniques used to bring out the biomarkers necessary for detection. Because of this, effective and practical spore disruption methods are desirable. In this study, we demonstrate the efficiency of a compact microfluidic lab-on-chip built around a coplanar waveguide (CPW) operating at 2.45 GHz. We show that the CPW generates an electric field hotspot of ∼10 kV/m, comparable to that of a commercial microwave oven, while using only 1.2 W of input power and thus resulting in negligible sample heating. Spores passing through the microfluidic channel are disrupted by the electric field and release calcium dipicolinic acid (CaDPA), a biomarker molecule present alongside DNA in the spore core. We show that it is possible to detect this disruption in a bulk spore suspension using fluorescence spectroscopy. We then use laser tweezers Raman spectroscopy (LTRS) to show the loss of CaDPA on an individual spore level and that the loss increases with irradiation power. Only 22% of the spores contain CaDPA after exposure to 1.2 W input power, compared to 71% of the untreated control spores. Additionally, spores exposed to microwaves appear visibly disrupted when imaged using scanning electron microscopy (SEM). Overall, this study shows the advantages of using a CPW for disrupting spores for biomarker release and detection.


Assuntos
Dispositivos Lab-On-A-Chip , Técnicas Microbiológicas , Micro-Ondas , Esporos Bacterianos , Biomarcadores/análise , Estimulação Elétrica , Técnicas Microbiológicas/instrumentação , Técnicas Microbiológicas/métodos , Microscopia Eletrônica de Varredura , Pinças Ópticas , Espectrometria de Fluorescência , Análise Espectral Raman , Esporos Bacterianos/química , Esporos Bacterianos/metabolismo , Esporos Bacterianos/efeitos da radiação , Esporos Bacterianos/ultraestrutura
4.
Sci Rep ; 12(1): 10172, 2022 06 17.
Artigo em Inglês | MEDLINE | ID: mdl-35715506

RESUMO

Visualizing medical images from patients as physical 3D models (phantom models) have many roles in the medical field, from education to preclinical preparation and clinical research. However, current phantom models are generally generic, expensive, and time-consuming to fabricate. Thus, there is a need for a cost- and time-efficient pipeline from medical imaging to patient-specific phantom models. In this work, we present a method for creating complex 3D sacrificial molds using an off-the-shelf water-soluble resin and a low-cost desktop 3D printer. This enables us to recreate parts of the cerebral arterial tree as a full-scale phantom model ([Formula: see text] cm) in transparent silicone rubber (polydimethylsiloxane, PDMS) from computed tomography angiography images (CTA). We analyzed the model with magnetic resonance imaging (MRI) and compared it with the patient data. The results show good agreement and smooth surfaces for the arteries. We also evaluate our method by looking at its capability to reproduce 1 mm channels and sharp corners. We found that round shapes are well reproduced, whereas sharp features show some divergence. Our method can fabricate a patient-specific phantom model with less than 2 h of total labor time and at a low fabrication cost.


Assuntos
Impressão Tridimensional , Água , Artérias , Encéfalo , Humanos , Imagens de Fantasmas
5.
Appl Opt ; 60(13): 3764-3771, 2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-33983309

RESUMO

Motorized rotation mounts and stages are versatile instruments that introduce computer control to optical systems, enabling automation and scanning actions. They can be used for intensity control, position adjustments, etc. However, these rotation mounts come with a hefty price tag, and this limits their use. This work shows how to build two different types of motorized rotation mounts for $1^{\prime \prime}$ optics, using a 3D printer and off-the-shelf components. The first is intended for reflective elements, such as mirrors and gratings, and the second for transmissive elements, such as polarizers and retarders. We evaluate and compare their performance to commercial systems based on velocity, resolution, precision, backlash, and axis wobble. Also, we investigate the angular stability using Allan variance analysis. The results show that our mounts perform similarly to systems costing as much as $\$ 2500\,\rm USD $, while also being quick to build and costing less than $\$ 220\,\rm USD$. As a proof of concept, we show how to control lasers used in an optical tweezers and Raman spectroscopy setup. When used for this, the 3D printed motorized rotational mounts provide intensity control with a resolution of 0.03 percentage points or better.