Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
1.
Biomolecules ; 13(4)2023 04 06.
Artigo em Inglês | MEDLINE | ID: mdl-37189401

RESUMO

Alternative splicing is an important mechanism in the process of eukaryotic nuclear mRNA precursors producing multiple protein products from a single gene. Although group I self-splicing introns usually perform regular splicing, limited examples of alternative splicing have also been reported. The exon-skipping type of splicing has been observed in genes containing two group I introns. To characterize splicing patterns (exon-skipping/exon-inclusion) of tandemly aligned group I introns, we constructed a reporter gene containing two Tetrahymena introns flanking a short exon. To control splicing patterns, we engineered the two introns in a pairwise manner to design pairs of introns that selectively perform either exon-skipping or exon-inclusion splicing. Through pairwise engineering and biochemical characterization, the structural elements important for the induction of exon-skipping splicing were elucidated.


Assuntos
Processamento Alternativo , Splicing de RNA , Íntrons/genética , Éxons/genética , Precursores de RNA/genética
2.
Sci Rep ; 12(1): 1418, 2022 01 26.
Artigo em Inglês | MEDLINE | ID: mdl-35082374

RESUMO

This study aimed to evaluate the robustness against geometric uncertainties in the hybrid intensity-modulated radiation therapy (IMRT) plans generated by commercially available software for automated breast planning (ABP). The ABP plans were compared with commonly used forward-planned field-in-field (FIF) technique plans. The planning computed tomography datasets of 20 patients who received left-sided breast-conserving surgery were used for both the ABP and FIF plans. Geometric uncertainties were simulated by shifting beam isocenters by 2, 3, 5, and 10 mm in the six directions: anterior/posterior, left/right, and superior/inferior. A total of 500 plans (20 patients and 25 scenarios, including the original plan) were created for each of the ABP and FIF plans. The homogeneity index of the target volume in the ABP plans was significantly better (p < 0.001) than the value in the FIF plans in the scenarios of shifting beam isocenters by 2, 3, and 5 mm. Mean heart dose and percentage volume of lungs receiving a dose more than 20 Gy were clinically acceptable in all scenarios. The hybrid IMRT plans generated by commercially available ABP software provided better robustness against geometric uncertainties than forward-planned FIF plans.


Assuntos
Neoplasias da Mama/radioterapia , Glândulas Mamárias Humanas/efeitos da radiação , Mastectomia Segmentar/métodos , Planejamento da Radioterapia Assistida por Computador/estatística & dados numéricos , Radioterapia de Intensidade Modulada/métodos , Software , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Neoplasias da Mama/cirurgia , Relação Dose-Resposta à Radiação , Feminino , Coração/efeitos da radiação , Humanos , Pulmão/efeitos da radiação , Glândulas Mamárias Humanas/diagnóstico por imagem , Glândulas Mamárias Humanas/patologia , Glândulas Mamárias Humanas/cirurgia , Órgãos em Risco , Dosagem Radioterapêutica , Tomografia Computadorizada por Raios X
3.
Cureus ; 13(9): e17743, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34659956

RESUMO

Aim To investigate the variation of tumor volume during moderate hypo-fractionated stereotactic body radiation therapy (SBRT). Patients and Methods Twenty patients, who received SBRT at our institution, were included in the analysis. A prescribed dose was 56 Gy at iso-center in seven fractions. Tumor volumes before and during SBRT were calculated. In order to investigate factors affecting the variation of tumor volume in RT 2 (after first irradiation) and RT 7 (after last irradiation), various parameters were verified by the Mann-Whitney U test. Results With regard to the low maximum standardized uptake values (SUVmax) group, transient increase of tumor volume was found in RT 2, and tumor volume reduction was hardly found in RT 7. With regard to the high SUVmax group, a transient increase was not found, and a definite reduction was found in the treatment course. Conclusion Accurate prediction of tumor volume variation is required for more accurate treatment, such as adaptive radiation therapy.

4.
Gan To Kagaku Ryoho ; 48(2): 239-241, 2021 Feb.
Artigo em Japonês | MEDLINE | ID: mdl-33597368

RESUMO

BACKGROUND: Preoperative chemoradiotherapy(CRT)followed by total mesorectal excision(TME)is used for locally advanced rectal cancer, but it can induce postoperative anorectal function. The primary objective of this study is to confirm the efficacy and safety of preoperative CRT and TME without irradiation to the internal and external sphincter muscles. SUBJECTS AND METHODS: Patients were eligible for this study if they met the following inclusion criteria: histologically proven rectal cancer, clinical T3T4N0-2 disease, and a distance between anal margin of tumor and the rental line is more than 2 cm. Twelve patients who underwent preoperative CRT and TME between 2013 and 2017 were enrolled. The primary endpoint was completion rate of sphincter-preserving surgery. RESULTS: All patients completed preoperative CRT without Grade 3 or higher adverse effect. Sphincter-preserving surgery was performed in all cases. The 5-year disease-free survival rate was 46.7%, and the local recurrence-free survival rate was 75%, and the overall survival rate was 90.9%. CONCLUSION: It is suggested that preoperative CRT and TME without irradiation to the internal and external sphincter muscles is effective and safe therapy for locally advanced rectal cancer.


Assuntos
Terapia Neoadjuvante , Neoplasias Retais , Quimiorradioterapia , Humanos , Neoplasias Retais/cirurgia , Reto , Resultado do Tratamento
5.
Cancer Diagn Progn ; 1(3): 193-200, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35399314

RESUMO

Background/Aim: The most severe adverse event of radiotherapy in lung cancer is radiation pneumonitis (RP). Some indices commonly used to prevent RP are evaluated based on the anatomical lung volume. The irradiation dose may be more accurately assessed by using functional lung volume. We evaluated the usefulness of computed tomography (CT) incorporating functional ventilation images acquired by the inhalation of xenon (Xe) gas (Xe-CT functional images). Patients and Methods: Two plans were created for twelve patients: volumetric modulated arc therapy (VMAT) planning using conventional chest CT images (anatomical plans) and VMAT planning using Xe-CT functional images (functional plans), and the dosimetric parameters were compared. Results: Compared to the anatomical plans, the functional plans had significantly reduced V 20Gy in the high-functional lungs (p=0.005), but significant differences were not seen in the moderate-functional and low-functional lungs. Conclusion: The incorporation of Xe-CT functional images into VMAT plans enables radiotherapy planning with consideration of lung function.

6.
J Xray Sci Technol ; 28(2): 243-254, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31985486

RESUMO

OBJECTIVE: Since most radiation treatment plans are based on computed tomography (CT) images, which makes it difficult to define the targeted tumor volume located near a metal implant, this study aims to evaluate and compare three treatment plans in order to optimally reduce geometrical uncertainty in external radiation treatment of localized prostate cancer. METHODS: Experimental subjects were three prostate patients with bilateral hip prosthesis who had undergone radical radiotherapy. The treatment plans were five-field three-dimensional conformal radiation therapy (3D-CRT), fixed 5-field intensity-modulated radiation therapy (IMRT) using similar gantry angles, and single-arc volumetric modulated arc therapy (VMAT). The monitor units (MUs), dose volume histograms (DVHs), the dose indices of planning target volume (PTV), clinical target volume (CTV) and rectum were compared among the three techniques. The geometrical uncertainties were evaluated by shifting the iso-center (2- 10 mm in the anterior, posterior, left, right, superior, and inferior directions). The CTV and rectum dose indexes with and without the iso-center shifts were compared in each plan. RESULTS: The Conformity Index of PTV were 1.35 in 3D-CRT, 1.12 in IMRT, and 1.04 in VMAT, respectively. The rectum doses in 3D-CRT are also higher than those in IMRT and VMAT. The iso-center shift little affected the CTV dose when smaller than the margin size. The rectum dose increased especially after a posterior shift. Additionally, this dose increase was larger in the VMAT plan than in the 3D- CRT plan. However, the VMAT achieved a superior rectum DVH to that of 3D- CRT, and this effect clearly exceeded the rectum-dose increase elicited by the iso-center shift. CONCLUSION: For radiotherapy treatment of localized prostate cancer in patients with hip prosthesis, the dose distribution was better in the VMAT and Metal Artifact Reduction (MAR)-CT image methods than the conventional methods. Because the anatomical structure of the male pelvic region is relatively constant among individuals, we consider that VMAT is a valid treatment plan despite analyzing just three cases.


Assuntos
Prótese de Quadril , Neoplasias da Próstata/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/métodos , Tomografia Computadorizada por Raios X/métodos , Incerteza , Idoso , Idoso de 80 Anos ou mais , Humanos , Masculino , Pessoa de Meia-Idade , Próstata/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos
7.
Igaku Butsuri ; 40(4): 119-125, 2020.
Artigo em Japonês | MEDLINE | ID: mdl-33390377

RESUMO

Using virtual reality (VR) technology such as head-mounted displays, users can be immersed in a virtual world and perceive it as reality. In radiation therapy departments, pretreatment patients and students rarely observe treatment rooms and treatment devices, making it difficult to understand the overall flow of radiation therapy. In this study, to facilitate the understanding and teaching of radiation therapy, we suggest the implementation of VR technology and develop software compatible with VR to enable a pertinent comprehension of radiation therapy. With versatility and accessibility in mind, the software is developed as an application for Android and iOS devices.Omnidirectional movies in treatment rooms were acquired from both the patient view and a third-person view using an omnidirectional camera. The Android/iOS devices used were AQUOS R (SHARP), iPhone 7 Plus (Apple), and iPad air (Apple). The software was developed using Unity 2018.4.7f (Unity Technologies). The main components of the software were as follows: (i) a home window featuring a user interface with which people can access arbitrarily rooms by tapping on floor maps or a list of treatment rooms, (ii) a snapshot mode providing 2D images of a treatment room as a slide show, and (iii) a movie mode displaying omnidirectional movies from the patient view or a third-person view. The virtual radiation therapy experience was executed by attaching the Android/iOS devices to 3D VR goggles (SAMONIC).The main components of the application operated in good conjunction on the Android/iOS devices, and live viewing in the virtual world ran smoothly with the VR technology. However, there were resolution limitations due to the specs of the camera and the devices. It will therefore be necessary to adjust the resolution and the frame rate according to the performance of the relevant devices. The application is instructive for both patients and students because the virtual radiation therapy experience is immersive when using the VR technology. In addition, the developed software can transfer data in a single package and has the ability to substitute images and omnidirectional movies with those appropriate for diagnostic radiology and nuclear medicine departments. Therefore, the developed application is highly versatile.


Assuntos
Radioterapia , Smartphone , Software , Realidade Virtual , Simulação por Computador , Estudos de Viabilidade , Humanos , Aplicativos Móveis
8.
Radiol Phys Technol ; 12(3): 249-259, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31115835

RESUMO

Automated treatment planning may decrease the effort required in planning and promote increased routine clinical use of intensity-modulated radiation therapy (IMRT) for many breast cancer patients. The aim of this study was to evaluate a new commercial automated planning software for tangential breast IMRT by comparing it with clinical plans from whole-breast irradiation. We prospectively enrolled 150 patients with Stage 0-1 breast cancer who underwent breast-conserving surgery at our institution between September 2016 and August 2017. Total doses of 42.56 Gy in 16 fractions (n = 98) or 50 Gy in 25 fractions (n = 44) were used. All treatment plans were retrospectively re-planned using the automated breast planning (ABP) software. All automated plans generated clinically deliverable beam parameters with no patient body collision and no contralateral breast pass through. The mean homogeneity index of the automatically generated clinical target volume, percentage volume of lungs receiving dose more than 20 Gy, mean heart dose, and dose to the highest irradiated 2-cc volumes of the irradiated volume were 0.077 ± 0.019, 4.2% ± 1.2%, 142 ± 69 cGy, and 105.8% ± 1.7% (prescribed dose: 100%), respectively. The mean planning time was 4.8 ± 1.4 min. The ABP software demonstrated high clinical acceptability and treatment planning cost efficiency for tangential breast IMRT. The ABP software may be useful for delivering high-quality treatment to a majority of patients with early-stage breast cancer.


Assuntos
Neoplasias da Mama/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada , Software , Adulto , Idoso , Automação , Humanos , Pessoa de Meia-Idade , Dosagem Radioterapêutica , Estudos Retrospectivos , Fatores de Tempo
9.
Australas Phys Eng Sci Med ; 41(4): 1069-1074, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30361917

RESUMO

The objective of this study was to clarify the usefuleness of the K parameters of the independent verification method using V100% (the volume of water receiving 100% of the prescription dose) for institutions implementing the high-dose-rate (HDR) intracavitary brachytherapy for gynecological cancer. The data of 249 plans of 11 institutions in Japan were used, and the constant K value obtained by a parameter fit for single-192Ir, two-192Ir, and three-192Ir systems was calculated. The predicted total dwell time calculated using the constant K value was defined as Tpr, and the total dwell time calculated using a radiation treatment planning system was defined as TRTP. The ratio of Tpr and TRTP for each plan was calculated. The constant K values (95% CI) obtained for each system outlined above were 1233 (1227-1240), 1205 (1199-1211), and 1171 (1167-1175), respectively. Regarding the Tpr/TRTP, the entire data were within 0.9-1.1. For accurate verification, it was clarified that constant K values should be calculated for each system. The Nuclear Regulatory Commission considers a difference of 20% between the prescribed total dose and the administered total dose as a reportable medical event. There is a need for a quick method to verify the accuracy with a minimum of 10% threshold of a plan. The constant K values in this study were obtained from multiple institutions, and the variation in the values among these institutions was small. The data obtained by this study may be used as a parameter of this verification method employed by numerous institutions, particularly those who have recently initiated HDR brachytherapy. In addition, for institutions already using this method, this data might be useful for the validation of the parameters which were used in such institutions.


Assuntos
Braquiterapia/métodos , Neoplasias dos Genitais Femininos/radioterapia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Feminino , Humanos , Medicina de Precisão/métodos , Garantia da Qualidade dos Cuidados de Saúde , Estudos Retrospectivos
10.
Genes Cells ; 23(6): 435-447, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29693296

RESUMO

The riboswitch is a class of RNA-based gene regulatory machinery that is dependent on recognition of its target ligand by RNA tertiary structures. Ligand recognition is achieved by the aptamer domain, and ligand-dependent structural changes of the expression platform then usually mediate termination of transcription or translational initiation. Ligand-dependent structural changes of the aptamer domain and expression platform have been reported for several riboswitches with short (<40 nucleotides) expression platforms. In this study, we characterized structural changes of the Vc2 c-di-GMP riboswitch that represses translation of downstream open reading frames in a ligand-dependent manner. The Vc2 riboswitch has a long (97 nucleotides) expression platform, but its structure and function are largely unknown. Through mutational analysis and chemical probing, we identified its secondary structures that are possibly responsible for switch-OFF and switch-ON states of translational initiation.


Assuntos
Aptâmeros de Nucleotídeos/metabolismo , GMP Cíclico/análogos & derivados , Escherichia coli/metabolismo , Biossíntese de Proteínas , RNA Bacteriano/metabolismo , Ribossomos/metabolismo , Aptâmeros de Nucleotídeos/química , Sequência de Bases , Sítios de Ligação , GMP Cíclico/química , GMP Cíclico/metabolismo , Escherichia coli/genética , Modelos Moleculares , Conformação de Ácido Nucleico , RNA Bacteriano/química , Riboswitch
11.
J Xray Sci Technol ; 26(3): 473-480, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29562582

RESUMO

PURPOSE: Based on a retrospective analysis, this study aims to develop a simple index for validity of the evaluation point for the dosimetric verification of intensity-modulated radiation therapy (IMRT). METHODS: The results for the dosimetric verifications of a total of 69 IMRT plans were analyzed in this study. A Farmer-type ion chamber was used as a dose detector, and a solid water-equivalent phantom was used. Index values were obtained by dividing the difference between the maximum and minimum dosages by the mean dosage of the 69 plans, and the values were classified into five groups with index value <4, 4-8, 8-12, 12-16, and >16. A t-test was used to assess the statistical significance of the mean differences of the absolute values of the relative errors among these groups. RESULTS: We found that there was no significant difference between the groups with index value <4 and 4-8 (p = 0.152); however, there were significant differences between the other groups (p < 0.01). In addition, when the index values were smaller than 8, the pass ratio of 3% tolerance was 96.2% and the pass ratio of 5% tolerance was 99.9%. We observed that the smaller the index value, the smaller the uncertainty of the dose measurement. CONCLUSIONS: The results obtained in this study may prove to be useful for accurate dosimetric verifications of IMRTs when ion chambers are used.


Assuntos
Dosagem Radioterapêutica/normas , Planejamento da Radioterapia Assistida por Computador/normas , Radioterapia de Intensidade Modulada/normas , Humanos , Imagens de Fantasmas , Radiometria/instrumentação , Radiometria/normas , Planejamento da Radioterapia Assistida por Computador/instrumentação , Radioterapia de Intensidade Modulada/instrumentação , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
12.
Angew Chem Int Ed Engl ; 56(20): 5494-5497, 2017 05 08.
Artigo em Inglês | MEDLINE | ID: mdl-28418229

RESUMO

In the presence of a cationic Ru catalyst, 1,6-diynes bearing a terminal styryl moiety underwent [2+2+2] cyclization to produce dehydrobiphenylenes fused with a five-membered ring. Although the cycloadducts were unstable toward purification, their one-pot iodine-mediated ring expansion successfully afforded unprecedented bridged ketone products containing a benzo-fused bicyclo[3.2.1] framework.

13.
J Biochem ; 160(3): 153-62, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27033943

RESUMO

The Vc2 riboswitch possesses an aptamer domain belonging to the class-I c-di-GMP riboswitch family. This domain has been analysed and the molecular mechanism by which it recognizes the c-di-GMP ligand has been elucidated. On the other hand, the regulatory mechanism of the full-length Vc2 riboswitch to control its downstream open reading frame (ORF) remains largely unknown. In this study, we performed in vivo reporter assays and in vitro biochemical analyses of the full-length riboswitch and its aptamer domain. We evaluated the results of in vivo and in vitro analyses to elucidate the regulatory mechanism of the Vc2 riboswitch. The present results suggest that recognition of c-di-GMP ligand by the Vc2 riboswitch aptamer domain downregulates expression of its downstream ORF primarily at the translational level.


Assuntos
GMP Cíclico/análogos & derivados , Conformação de Ácido Nucleico , Fases de Leitura Aberta/fisiologia , Riboswitch/fisiologia , GMP Cíclico/química , GMP Cíclico/metabolismo
14.
J Radiat Res ; 54(1): 135-9, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22843378

RESUMO

The purpose of this study was to compare the size and clearness of gross tumor volumes (GTVs) of metastatic brain tumors on T1-weighted magnetic resonance images between a single dose contrast administration protocol and a double dose contrast administration protocol to determine the optimum dose of contrast-enhancement for clear delineation of GTV in stereotactic radiotherapy (SRT). A total of 28 small metastatic brain tumors were evaluated in 13 patients by intra-individual comparison of GTV measurements using single dose and double dose contrast-enhanced thin-slice (1-mm) magnetic resonance imaging (MRI). All patients had confirmed histological types of primary tumors and had undergone hypo-fractionated SRT for metastatic brain tumors. The mean tumor diameter with single dose and double dose contrast-enhancement was 12.0 ± 1.1 mm and 13.2 ± 1.1 mm respectively (P < 0.001). The mean incremental ratio (MIR) obtained by comparing mean tumor diameters was 11.2 ± 0.02 %. The mean volume of GTV-1 (single dose contrast-enhancement) and GTV-2 (double dose contrast-enhancement) was 1.38 ± 0.41 ml and 1.59 ± 0.45 ml respectively (P < 0.01). The MIR by comparing mean tumor volumes was 32.3 ± 0.4 %. The MIR of GTV-1 with < 1 ml volume and GTV-1 with > 1 ml volume was 41.8 ± 0.05 % and 12.4 ± 0.03 % respectively (P < 0.001). We conclude that double dose contrast-enhanced thin-slice MRI is a more useful technique than single dose contrast-enhanced thin-slice MRI, especially for clear delineation of GTVs of small metastatic brain tumors in treatment planning of highly precise SRT.


Assuntos
Neoplasias Encefálicas/secundário , Neoplasias Encefálicas/cirurgia , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/métodos , Idoso , Neoplasias Encefálicas/patologia , Meios de Contraste , Relação Dose-Resposta à Radiação , Feminino , Humanos , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade , Radiometria/métodos , Dosagem Radioterapêutica , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Carga Tumoral/efeitos da radiação
15.
Radiology ; 262(1): 262-8, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22025733

RESUMO

PURPOSE: To assess single-breath-hold technique for ventilation mapping by using dual-energy computed tomography (CT) in phantom experiments and volunteers. MATERIALS AND METHODS: Institutional review board approved this study, and written informed consent was obtained from all volunteers. A rubber bag filled with a mixture of xenon (0%-35.4%) and oxygen was scanned with dual-source dual-energy CT (80 kV and 140 kV with tin [Sn] filter [Sn/140 kV] and 100 kV and Sn/140 kV). A cylinder containing six tubes of identical sizes with different apertures was ventilated once with a mixture of 35% xenon and 65% oxygen and was scanned in dual-energy mode (80 kV and Sn/140 kV). Xenon-enhanced images were derived by using three-material decomposition technique. Four volunteers were scanned twice in dual-energy mode (80 kV and Sn/140 kV) during breath hold after a single vital-capacity inspiration of air (nonenhanced) and of 35% xenon. Xenon-enhanced images were obtained by using two methods: three-material decomposition and subtraction of nonenhanced from xenon-enhanced images. Regression analysis with t and F tests was applied to the data of the rubber bag scans, with the significance level set at .05. RESULTS: Mean pixel values of gas in the bag were linearly related to xenon concentration for all x-ray tube voltages (r(2) = 1.00, P < .00001). Pixel values of the xenon-enhanced images of the tubes were related to their aperture size. Nearly homogeneous (coefficient of variation: 0.22, 0.23, and 0.34) pixel values were found in the lungs of healthy volunteers, with higher pixel values in the trachea and lower pixel values in the bullae. Xenon-enhanced images calculated by using three-material decomposition had better image quality on visual comparison than those calculated by using subtraction. CONCLUSION: Xenon-enhanced dual-energy CT with the single-breath-hold technique could depict ventilation in phantoms and in four volunteers.


Assuntos
Pulmão/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Xenônio , Algoritmos , Humanos , Imageamento Tridimensional , Imagens de Fantasmas , Análise de Regressão , Respiração
16.
Gan To Kagaku Ryoho ; 36(12): 2245-7, 2009 Nov.
Artigo em Japonês | MEDLINE | ID: mdl-20037384

RESUMO

This retrospective study was performed to evaluate the outcomes of 12 patients with brain metastasis from colorectal cancer treated between 1999 and 2008. The range of patients was 33-72 years old (median: 64 years old). The male to female ratio was 2:1. The primary site was the colon in 4 patients and rectum in 8 patients. The site of brain metastasis was the cerebrum in 8 and cerebellum in 4. All brain lesions were metachronously detected. Three patients had a single lesion each, while the remaining 9 had multiple lesions. The range of the period from the resection of the primary lesion to the detection of brain metastasis was 144-2,062 days (median: 868 days). The types of treatment included whole brain radiotherapy after cerebral metastatectomy in three patients with a single lesion, whole brain radiotherapy only in 7 patients with multiple lesions, and modified FOLFOX6 (mFOLFOX6) regimen combined with whole brain radiation in recently treated two patients with multiple brain and lung metastases. The median overall survival period was 107 days. The longest survivor was a patient who survived for 505 days after the start of mFOLFOX6 plus radiation therapy. It appears that how we control metastases has become more important in recent years. For example, using new drugs, extracranial metastases of controllable cancer have become better controllable over longer periods.


Assuntos
Neoplasias Encefálicas/secundário , Neoplasias Colorretais/patologia , Adulto , Idoso , Neoplasias Encefálicas/terapia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
17.
Radiat Med ; 26(7): 396-401, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18769996

RESUMO

PURPOSE: The importance of the quality of life (QOL) and mental condition of patients being treated for cancer is now recognized. In this study, we evaluated QOL and mental condition in patients with cancer before and after radiotherapy. MATERIALS AND METHODS: The subjects were 170 patients who had undergone radiotherapy. The examination of QOL was performed using the quality of life questionnaire for cancer patients treated with anticancer drugs (QOL-ACD), and mental condition (anxiety and depression) was examined using the hospital anxiety and depression scale (HADS). These examinations were performed at the start of radiotherapy and immediately after radiotherapy. RESULTS: The QOL score was slightly higher in all patients after the completion of radiotherapy than before the start of radiotherapy. In the palliative radiotherapy group, QOL score was significantly improved by treatment. Anxiety and depression were improved after radiotherapy. There was a correlation between the degrees of improvement of the HADS and QOL score. CONCLUSION: We could treat cancer patients by radiotherapy without reducing their QOL, and improvement in QOL was significant in the palliative radiotherapy group. Mental condition was also improved after radiotherapy.


Assuntos
Neoplasias da Mama/psicologia , Neoplasias Esofágicas/psicologia , Neoplasias Pulmonares/psicologia , Transtornos Mentais/etiologia , Qualidade de Vida , Neoplasias Urogenitais/psicologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Transtornos de Ansiedade/diagnóstico , Transtornos de Ansiedade/etiologia , Transtornos de Ansiedade/psicologia , Atitude Frente a Saúde , Neoplasias da Mama/radioterapia , Transtorno Depressivo/diagnóstico , Transtorno Depressivo/etiologia , Transtorno Depressivo/psicologia , Neoplasias Esofágicas/complicações , Neoplasias Esofágicas/radioterapia , Feminino , Humanos , Neoplasias Pulmonares/complicações , Neoplasias Pulmonares/radioterapia , Masculino , Transtornos Mentais/diagnóstico , Transtornos Mentais/psicologia , Pessoa de Meia-Idade , Cuidados Paliativos/psicologia , Cuidados Paliativos/estatística & dados numéricos , Escalas de Graduação Psiquiátrica/estatística & dados numéricos , Inquéritos e Questionários , Neoplasias Urogenitais/complicações , Neoplasias Urogenitais/radioterapia , Adulto Jovem
18.
Radiat Med ; 26(10): 582-6, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19132488

RESUMO

PURPOSE: The aim of this study was to evaluate the epiploic appendages in patients with acute abdomen using multidetector computed tomography (MDCT) and to determine the incidence of primary and secondary epiploic appendagitis (EA). MATERIALS AND METHODS: A radiologist reviewed MDCT images from 1338 patients with acute abdomen for visible epiploic appendages. Two radiologists then reviewed the MDCT images showing inflamed epiploic appendages and diagnosed primary EA, secondary EA, or other conditions by consensus. The CT criteria for primary EA are a round or oval pericolonic fatty lesion with a hyperattenuated rim and adjacent fat stranding, without other causes of inflammation. Secondary EA is diagnosed if an epiploic appendage is found to be due to inflammation from other inflammatory entities. RESULTS: Epiploic appendages were identified in 19 patients. Four patients (0.3%) had a retrospective CT diagnosis of primary EA. Twelve patients (0.9%) had a retrospective CT diagnosis of secondary EA (primary condition was diverticulitis in 10 patients and inflammatory bowel disease in 2 patients). The remaining three patients had calcification of an epiploic appendage suggestive of old EA. CONCLUSION: Primary EA should be included in the differential diagnosis of acute abdomen. Occasionally, inflammation of the epiploic appendages is secondary to other inflammatory conditions.


Assuntos
Colite/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Abdome Agudo/etiologia , Adulto , Colite/complicações , Colo/diagnóstico por imagem , Meios de Contraste , Diagnóstico Diferencial , Diverticulite/complicações , Feminino , Humanos , Doenças Inflamatórias Intestinais/complicações , Iohexol , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Intensificação de Imagem Radiográfica/métodos , Estudos Retrospectivos
19.
Ann Nucl Med ; 21(5): 245-9, 2007 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-17634841

RESUMO

OBJECTIVES: In order to predict the prognosis or complications of portal hypertension in patients with chronic liver disease, it is important to evaluate both hepatic functional reserve and portal circulation. On (99m)Tc-galactosyl human serum albumin ((99m)Tc-GSA) scintigraphy, the index of blood clearance (HH15) and receptor index (LHL15) have been widely used to evaluate the hepatic functional reserve. However, the relationship between these indices and portal circulation is unknown. The purpose of this study was to examine the relationship between HH15 and LHL15 and portosystemic shunts evaluated with arteriographic portography or esophagogastroduodenoscopy. METHODS: A total of 82 patients with chronic liver disease (mean age, 66.7 years) who underwent (99m)Tc-GSA scintigraphy, arteriographic portography, and esophagogastroduodenoscopy were enrolled. HH15 and LHL15 were obtained from dynamic (99m)Tc-GSA scintigraphy. The patients were divided into three groups according to the arteriographic portography findings: group 1, no portal collateral circulation; group 2, mild collateral development; and group 3, moderate to severe collateral development. They were also divided into three groups based on the esophagogastroduodenoscopic findings: group A, no varices; group B, small-caliber varices; and group C, enlarged varices. The Kruskal-Wallis test was used to compare each index among these groups. Receiver operating characteristic (ROC) analysis was used to determine whether each index was an indicator for the presence of portosystemic shunts. RESULTS: Both HH15 and LHL15 differed significantly between groups 1 and 2 and between groups 1 and 3. However, only HH15 differed significantly between groups A and B and between groups A and C. On the basis of the ROC analysis, the HH15 threshold value of 0.62 yielded both excellent sensitivity (83.9%) and specificity (84.6%) for the presence of portosystemic shunts, as evaluated with arteriographic portography. The HH15 threshold value of 0.64 yielded both good sensitivity (66.1%) and specificity (69.2%) for the presence of portosystemic shunts, as evaluated with esophagogastroduodenoscopy, whereas no adequate threshold value of LHL15 was found for the presence of portosystemic shunts. CONCLUSIONS: HH15 is a potent indicator of the presence of portosystemic shunts in chronic liver disease.


Assuntos
Hepatopatias/diagnóstico por imagem , Hepatopatias/diagnóstico , Testes de Função Hepática/métodos , Compostos Radiofarmacêuticos/farmacologia , Agregado de Albumina Marcado com Tecnécio Tc 99m/química , Pentetato de Tecnécio Tc 99m/química , Idoso , Angiografia/métodos , Endoscopia , Reações Falso-Positivas , Humanos , Pessoa de Meia-Idade , Derivação Portossistêmica Cirúrgica , Curva ROC , Cintilografia/instrumentação , Cintilografia/métodos
20.
Radiat Med ; 25(2): 73-5, 2007 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17541516

RESUMO

We encountered a case of arteriovenous malformation (AVM) of the gallbladder in a patient with hepatocellular carcinoma (HCC). Contrast-enhanced computed tomography (CT) showed serpentine vessels around and within the gallbladder wall. Angiography showed dilated and tortuous cystic arteries, a racemose vascular network, and early-filling cystic veins. Transcatheter arterial embolization of two cystic arteries feeding the AVM was performed with platinum microcoils prior to transcatheter arterial chemoembolization for HCC to prevent embolic particles from flowing into these arteries. Follow-up contrast-enhanced CT showed blood flow in the gallbladder AVM, which appeared to be fed by the arterial collaterals.


Assuntos
Malformações Arteriovenosas/diagnóstico por imagem , Vesícula Biliar/irrigação sanguínea , Idoso , Angiografia , Malformações Arteriovenosas/terapia , Carcinoma Hepatocelular/complicações , Quimioembolização Terapêutica , Circulação Colateral , Meios de Contraste , Feminino , Humanos , Neoplasias Hepáticas/complicações , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...