Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Heliyon ; 10(10): e31177, 2024 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-38813238

RESUMO

Background: Pulmonary hypertension (PH) is a severe vascular disorder that may affect 50 % of patients with heart failure. Currently, right-sided heart catheterization is required to definitively diagnose PH. However, this method is invasive and thus may not be appropriate for repeated, long-term monitoring of PH patients. This retrospective study's aim was to evaluate whether 4D flow magnetic resonance imaging (MRI) can be used to quantitively measure flow parameters to identify patients with PH. Methods: The study cohort included 97 patients recruited from a single institution and divided into three groups based on echocardiographic estimate of pulmonary artery systolic pressure (PASP): normal group with PASP<36 mmHg, borderline PH group with PASP of 37-50 mmHg, and PH group with PASP>50 mmHg. 4D flow MRI was used to quantitively assess blood flow and velocity, regurgitation, wall shear stress (WSS) and kinetic energy in the pulmonary artery trunk, right main pulmonary artery, and left pulmonary artery. Two experienced radiologists independently analyzed the MR images, blinded to clinical details. Results: We found a significant difference in WSS in the pulmonary artery trunk, right main pulmonary artery and left main pulmonary artery among the three patient groups. We also found significant differences in the kinetic energy and average through velocity in the pulmonary artery trunk and right main pulmonary artery, and significant differences in the flow rate in the right main pulmonary artery. Conclusion: These data suggest that 4D flow MRI can quantitate pulmonary artery flow parameters and distinguish between patients with and without PH.

2.
Medicine (Baltimore) ; 101(2): e28563, 2022 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-35029224

RESUMO

ABSTRACT: The purpose of this study was to investigate whether there were significant differences in the intensity distributions of thoracic aorta hemodynamic parameters between groups with different ejection fractions (EF) using four-dimensional flow magnetic resonance imaging and to investigate the relationships between each parameter.A total of 26 patients, 13 each with EF of >60% and <30%, underwent cardiac four-dimensional flow magnetic resonance imaging (EF >60%: mean age: 54 ±â€Š11.6 years, EF <30%: mean age: 49.2 ±â€Š17.2 years). The thoracic aorta was divided into the proximal and distal ascending aorta (AAo), aortic arch, and the proximal and distal descending aorta, and each section was further divided into the anterior wall, posterior wall, lesser curvature, and greater curvature. The intensity distributions of wall shear stress (WSS), energy loss (EL), and vorticity (Vort) (hemodynamic parameters) and the concordance rates between these distributions were analyzed.The concordance rate between the intensity distributions of EL and Vort was high. Only the intensity distributions of EL and Vort in the distal AAo differed significantly between the groups (P < .001). In the EF >60% group, these intensity distributions showed higher values in the greater curvature of the AAo, whereas in the EF <30% group higher values were seen in the lesser curvature of the AAo.Although there was no significant intergroup difference in the WSS intensity distribution, in the EF <30% group the WSS intensity distribution tended to exhibit higher values in the lesser curvature of the distal AAo, and the WSS intensity distribution values for the greater curvature tended to gradually increase from the arch to the proximal descending aorta.The only significant differences between the EF groups were found in the intensity distributions of EL and Vort in the distal AAo. This suggests that the distributions of atherosclerosis may be EF-dependent.


Assuntos
Aorta Torácica , Hemodinâmica , Adulto , Idoso , Aorta Torácica/diagnóstico por imagem , Velocidade do Fluxo Sanguíneo , Humanos , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade , Estresse Mecânico , Volume Sistólico
3.
Lung ; 199(5): 475-483, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34459967

RESUMO

OBJECTIVE: Balloon pulmonary angioplasty (BPA) is used to treat patients with inoperable chronic thromboembolic pulmonary hypertension (CTEPH); the goal is to improve pulmonary perfusion. We aimed to evaluate lung perfusion blood volume (PBV) with haemodynamic and exercise-capacity parameters to assess the efficacy of BPA in the treatment of CTEPH. METHODS: We retrospectively studied 33 patients over a 6-year period. DECT pulmonary angiography was performed before and after BPA. DECT provided iodine distribution maps; whole-lung and regional PBV images and quantification were generated using post-processing software. A mosaic pattern suggesting perfusion inhomogeneity is typical in CTEPH. Hypothetically, BPA treatment would promote homogenization that would be reflected in the calculated standard deviation. RESULTS: Lung perfusion images showed decreased heterogeneity after BPA. There was a significant difference before and after BPA in the whole-lung PBV and in the regional standard deviation for pulmonary arterial pressure (R = 0.37, p = 0.032 and R = 0.57, p = 0.006), pulmonary vascular resistance (R = 0.51, p = 0.023 and R = 0.60, p = 0.002), transtricuspid pressure gradient (R = 0.50, p = 0.0028 and R = 0.61, p = 0.0001), brain natriuretic peptide (R = 0.54, p = 0.0012 and R = 0.46, p = 0.0078), and 6-min walking distance (R = 0.59, p = 0.003 and R = 0.26, p = 0.14). The effects were especially pronounced after the first BPA procedure. CONCLUSION: Decreased lung heterogeneity may suggest BPA efficacy in treating CTEPH. After BPA treatment, improved lung PBV and improved regional standard deviation showed a strong positive correlation with haemodynamic parameters and exercise capacity, which also suggests that BPA is effective in treating CTEPH.


Assuntos
Angioplastia com Balão , Hipertensão Pulmonar , Embolia Pulmonar , Volume Sanguíneo , Doença Crônica , Humanos , Hipertensão Pulmonar/diagnóstico por imagem , Hipertensão Pulmonar/terapia , Pulmão/diagnóstico por imagem , Perfusão , Artéria Pulmonar/diagnóstico por imagem , Embolia Pulmonar/complicações , Embolia Pulmonar/diagnóstico por imagem , Embolia Pulmonar/terapia , Estudos Retrospectivos , Tomografia
4.
Vasc Endovascular Surg ; 55(1): 91-94, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32875955

RESUMO

Spontaneous ilio-iliac arteriovenous fistula (AVF) associated with aneurysms affecting the abdominal aortic and iliac arteries is a rare condition. The classical clinical symptoms of ilio-iliac AVF include high-output heart failure, abdominal pain, abdominal bruits and thrills, a pulsatile abdominal mass, and venous congestion symptoms (leg edema and hematuria). The prompt repair of AVF is necessary to restore the patient's hemodynamics. We report a case in which a patient with aneurysms affecting the abdominal aortic and iliac arteries and an ilio-iliac AVF presented with high-output heart failure and leg ischemia and was successfully treated via endovascular stent graft repair.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Fístula Arteriovenosa/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Aneurisma Ilíaco/cirurgia , Artéria Ilíaca/cirurgia , Veia Ilíaca/cirurgia , Idoso , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/fisiopatologia , Fístula Arteriovenosa/diagnóstico por imagem , Fístula Arteriovenosa/fisiopatologia , Prótese Vascular , Implante de Prótese Vascular/instrumentação , Procedimentos Endovasculares/instrumentação , Humanos , Aneurisma Ilíaco/diagnóstico por imagem , Aneurisma Ilíaco/fisiopatologia , Artéria Ilíaca/diagnóstico por imagem , Artéria Ilíaca/fisiopatologia , Veia Ilíaca/diagnóstico por imagem , Veia Ilíaca/fisiopatologia , Masculino , Stents , Resultado do Tratamento
5.
SAGE Open Med Case Rep ; 8: 2050313X20971894, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33224502

RESUMO

Aortic mural thrombi of the ascending aorta are rare. If an aortic mural thrombus is dislodged, it can cause various embolic complications, which can sometimes be fatal. Although contrast-enhanced computed tomography (CT) and transesophageal echography are useful for diagnosing aortic mural thrombi, four-dimensional CT (4D-CT) is one of the most useful modalities for both diagnosis and treatment selection in such cases. 4D-CT can be used to evaluate the morphology and mobility of thrombi. Furthermore, it is minimally invasive. To the best of our knowledge, there have not been any reports about 4D-CT being used to depict an asymptomatic ascending aortic thrombus. We report a very unusual case, involving an aortic mural thrombus of the ascending aorta.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...