Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Biosens Bioelectron ; 198: 113832, 2022 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-34856516

RESUMO

This study aimed to develop an electrochemical system for measuring blood ATP and lactate levels in a single format. The ratio of lactate to ATP levels was previously reported to provide an alternative illness severity score. Although severity evaluation is crucial to treat patients with acute disease admitted to intensive care units, no sensors are currently available to simply and rapidly measure ATP and lactate levels using the same detection method. Therefore, we constructed an integrated sensing system for ATP and lactate using enzymatic reactions and two sets of electrodes integrated into a chip connected to a single potentiostat operated by a microcontroller. The enzymatic system involves adenylate kinase, pyruvate kinase, and pyruvate oxidase for ATP, and lactate oxidase for lactate, both of which produce hydrogen peroxide. Multiplex enzyme-based reactions were designed to minimize the corresponding operations significantly without enzyme immobilization onto the electrodes. The system was robust in the presence of potentially interfering blood components, such as ascorbate, pyruvate, ADP, urate, and potassium ions. The ATP and lactate levels in the blood were successfully measured using the new sensor with good recoveries. The analytical results of blood samples obtained using our sensor were in good agreement with those using conventional methods. Integrating electrode-based analysis and a microcontroller-based system saved further operations, enabling the straightforward measurement of ATP and lactate levels within 5 min. The proposed sensor may serve as a useful tool in the management of serious infectious diseases.


Assuntos
Técnicas Biossensoriais , Ácido Láctico , Trifosfato de Adenosina , Eletrodos , Humanos , Gravidade do Paciente
2.
Biosens Bioelectron ; 190: 113414, 2021 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-34130087

RESUMO

Antibody detection methods for viral infections have received broad attention due to the COVID-19 pandemic. In addition, there remains an ever-increasing need to quantitatively evaluate the immune response to develop vaccines and treatments for COVID-19. Here, we report an analytical method for the rapid and quantitative detection of SARS-CoV-2 antibody in human serum by fluorescence polarization immunoassay (FPIA). A recombinant SARS-CoV-2 receptor binding domain (RBD) protein labeled with HiLyte Fluor 647 (F-RBD) was prepared and used for FPIA. When the anti-RBD antibody in human serum binds to F-RBD, the degree of polarization (P) increases by suppressing the rotational diffusion of F-RBD. The measurement procedure required only mixing a reagent containing F-RBD with serum sample and measuring the P value with a portable fluorescence polarization analyzer after 15 min incubation. We evaluated analytical performance of the developed FPIA system using 30 samples: 20 COVID-19 positive sera and 10 negative sera. The receiver operating characteristic curve drawn with the obtained results showed that this FPIA system had high accuracy for discriminating COVID-19 positive or negative serum (AUC = 0.965). The total measurement time was about 20 min, and the serum volume required for measurement was 0.25 µL. Therefore, we successfully developed the FPIA system that enables rapid and easy quantification of SARS-CoV-2 antibody. It is believed that our FPIA system will facilitate rapid on-site identification of infected persons and deepen understanding of the immune response to COVID-19.


Assuntos
Técnicas Biossensoriais , COVID-19 , Anticorpos Antivirais , Imunoensaio de Fluorescência por Polarização , Humanos , Pandemias , SARS-CoV-2
3.
ACS Omega ; 6(12): 8340-8345, 2021 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-33817494

RESUMO

Analytical methods with fluorescence detection are in widespread use for detecting low abundance analytes. Here, we report a simple method for fluorescence signal amplification utilizing a structure of an azide-unit pendant water-soluble photopolymer (AWP) in a microchannel. The AWP is a poly(vinyl alcohol)-based photocross-linkable polymer, which is often used in biosensors. We determined that the wall-like structure of the AWP (AWP-wall) constructed in a microchannel functioned as an amplifier of a fluorescence signal. When a solution of fluorescent molecules was introduced into the microchannel having the AWP-wall, the fluorescent molecules accumulated inside the AWP-wall by diffusion. Consequently, the fluorescence intensity inside the AWP-wall increased locally. Among the fluorescent molecules considered in this paper, 9H-(1,3-dichloro-9,9-dimethylacridin-2-one-7-yl) (DDAO) showed the highest efficiency of fluorescence signal amplification. We prepared a calibration curve for DDAO using the fluorescence intensity inside the AWP-wall, and the sensitivity was 5-fold that for the microchannel without the AWP-wall. This method realizes the improved sensitivity of fluorescence detection easily because the fluorescence signal was amplified only by injecting the solution into the microchannel having the AWP-wall. Furthermore, since this method is not limited to only the use of microchannel, we expect it to be applicable in various fields.

4.
Anal Bioanal Chem ; 413(18): 4619-4623, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33547481

RESUMO

Nowadays, the diagnosis of viral infections is receiving broad attention. We have developed a non-competitive fluorescence polarization immunoassay (NC-FPIA), which is a separation-free immunoassay, for a virus detection. H5 subtype avian influenza virus (H5-AIV) was used as a model virus for the proof of concept. The fluorescein-labeled Fab fragment that binds to H5 hemagglutinin was used for NC-FPIA. The purified H5-AIV which has H5 hemagglutinin was mixed with the fluorescein-labeled Fab fragment. After that, the degree of fluorescence polarization was measured with a portable FPIA analyzer. H5-AIV was successfully detected with an incubation time of 15 min. In addition, the portable FPIA analyzer enables performance of on-site NC-FPIA with a sample volume of 20 µL or less. This is the first research of detecting a virus particle by FPIA. This NC-FPIA can be applied to rapid on-site diagnosis of various viruses.


Assuntos
Imunoensaio de Fluorescência por Polarização/métodos , Virus da Influenza A Subtipo H5N1/isolamento & purificação , Influenza Aviária/virologia , Animais , Galinhas , Imunoensaio de Fluorescência por Polarização/instrumentação , Virus da Influenza A Subtipo H5N1/genética , Reação em Cadeia da Polimerase , Sensibilidade e Especificidade
5.
PLoS One ; 15(11): e0241422, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33196648

RESUMO

Detecting molecular targets in specimens from patients with lung cancer is essential for targeted therapy. Recently, we developed a highly sensitive, rapid-detection device (an immuno-wall device) that utilizes photoreactive polyvinyl alcohol immobilized with antibodies against a target protein via a streptavidin-biotin interaction. To evaluate its performance, we assayed epidermal growth factor receptor (EGFR) mutations, such as E746_A750 deletion in exon 19 or L858R substitution in exon 21, both of which are common in non-small cell lung cancer and important predictors of the treatment efficacy of EGFR tyrosine kinase inhibitors. The results showed that in 20-min assays, the devices detected as few as 1% (E746_A750 deletion) and 0.1% (L858R substitution) of mutant cells. Subsequent evaluation of detection of the mutations in surgically resected lung cancer specimens from patients with or without EGFR mutations and previously diagnosed using commercially available, clinically approved genotyping assays revealed diagnostic sensitivities of the immuno-wall device for E746_A750 deletion and L858R substitution of 85.7% and 87.5%, respectively, with specificities of 100% for both mutations. These results suggest that the immuno-wall device represents a good candidate next-generation diagnostic tool, especially for screening of EGFR mutations.


Assuntos
Análise Mutacional de DNA/instrumentação , Neoplasias Pulmonares/genética , Mutação/genética , Calibragem , Linhagem Celular Tumoral , Receptores ErbB/genética , Receptores ErbB/imunologia , Fluorescência , Genótipo , Humanos , Imunoensaio
6.
Anal Chem ; 92(21): 14393-14397, 2020 11 03.
Artigo em Inglês | MEDLINE | ID: mdl-33094615

RESUMO

Fluorescent polarization immunoassay (FPIA) is a single-step immunoassay method that is applicable to point-of-care testing; however, its applicability to large biomolecules has been restricted because ordinary FPIA is a competitive assay. Here, we report a noncompetitive FPIA using the variable domain from the heavy chain of a camelid antibody (VHH antibody). FPIA with VHH was successfully used to quantitate rabbit immunoglobulin G (IgG) and demonstrated a wider response range than that observed with antibody-binding (Fab) fragment. Then, using a portable FPIA instrument, a VHH-based immunoassay of human IgG in a human serum certified reference material was demonstrated.


Assuntos
Imunoensaio de Fluorescência por Polarização/métodos , Imunoglobulina G/análise , Animais , Humanos , Imunoglobulina G/sangue , Imunoglobulina G/imunologia , Limite de Detecção , Coelhos , Anticorpos de Domínio Único/imunologia
7.
Sens Actuators B Chem ; 316: 128160, 2020 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-32322135

RESUMO

A rapid, facile and selective detection of anti-H5 subtype avian influenza virus (AIV) antibody in serum by fluorescence polarization immunoassay (FPIA) was achieved. A fragment of recombinant H5 subtype AIV hemagglutinin was produced and labeled with fluorescein to use it as a labeled antigen in FPIA. This labeled antigen was mixed with anti-AIV sera (H1-H16 subtypes) and FP of the mixture was measured using a portable FP analyzer on a microdevice. It was found that FP increased in proportion to the concentration of anti-H5 AIV antibody (serum) and was significantly higher than FP obtained with the other sera. The selective detection of anti-H5 subtype AIV antibody was confirmed. The required volume of original sample was 2 µL and analysis time was within 20 min. This detection system realizes an efficient on-site diagnosis and surveillance of AIV.

8.
ACS Omega ; 4(15): 16683-16688, 2019 Oct 08.
Artigo em Inglês | MEDLINE | ID: mdl-31616851

RESUMO

Avian influenza virus (AIV) infection, caused by influenza virus type A, is an infectious, acute respiratory disease of birds related to influenza outbreaks worldwide. The highly pathogenic AIV subtype H5N1 has crossed species barriers to infect mammals, including humans, with fatal outcomes and has received attention as a potential pandemic threat. A rapid and timely detection in poultry is vitally important to prevent the virus spread. Despite their great sensitivity, conventional detection methods such as real-time reverse transcription-polymerase chain reaction and the agar gel precipitation test are time-consuming and labor-intensive and require special training. In this work, an immunowall device was evaluated as an easier and faster way for detecting AIV H5-hemagglutinin (AIV H5-HA). For detection, fluorescence-labeled or enzyme-labeled antibody was employed as a labeling antibody in a sandwich immunoassay. Both were shown in this paper to be easier and faster assays for detection compared with the conventional enzyme-linked immunosorbent assay (ELISA) kit. In addition, high selectivity was achieved for AIV H5-HA detection after the evaluation of other different HA virus subtypes. The limit of detection was 0.23 ng/mL for the enzyme-labeled antibody. This value was equivalent to that of the conventional ELISA kit but 8 times faster (31 min compared to 260 min). The detection range was 0.23-100 ng/mL. The immunowall device with the enzyme-labeled antibody offers a rapid, sensitive, selective, and simple immunoassay system for future H5 AIV real sample detection.

9.
Analyst ; 144(15): 4589-4595, 2019 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-31237262

RESUMO

We present an ultrasensitive immunoassay system for disease biomarkers utilizing the immuno-wall device and an enzymatic amplification reaction. The immuno-wall device consisted of 40 microchannels, each of which contained an antibody-modified wall-like structure along the longitudinal axis of the microchannel. The wall was fabricated with a water-soluble photopolymer containing streptavidin by photolithography, and biotinylated capture antibodies were immobilized on the sides through streptavidin-biotin interaction. For an assay, introducing the target biomarker and secondary and labeled antibodies produced a sandwich complex anchored on the sides of the wall. A conventional immuno-wall device uses a fluorescence-labeled antibody as a labeling antibody. To achieve an ultrasensitive detection of a trace biomarker, we used an enzyme label and amplified the signal with the enzymatic reaction with a fluorogenic substrate in the microchannel. The highest signal/background ratio was obtained by using alkaline phosphatase-labeled antibody and 9H-(1,3-dichloro-9,9-dimethylacridin-2-one-7-yl) phosphate. To evaluate the device performance, we detected human C-reactive protein (CRP) as a model biomarker. The detection limit (LOD) of CRP in phosphate-buffered saline was 2.5 pg mL-1 with a sample volume of 0.25 µL. This LOD was approximately 3 orders of magnitude lower than that obtained with fluorescent-dye (DyLight 650)-labeled antibody. In addition, the present device provided a wide detection range of 0.0025-10 ng mL-1 for CRP. We successfully developed an ultrasensitive immunoassay system with simple operation and only a small sample volume.


Assuntos
Proteína C-Reativa/análise , Imunoensaio/métodos , Dispositivos Lab-On-A-Chip , Acridinas/química , Fosfatase Alcalina/química , Animais , Anticorpos Imobilizados/imunologia , Biomarcadores/sangue , Proteína C-Reativa/imunologia , Corantes Fluorescentes/química , Cabras , Humanos , Imunoensaio/instrumentação , Limite de Detecção , Camundongos , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodos , Coelhos
10.
Lab Chip ; 19(15): 2581-2588, 2019 08 07.
Artigo em Inglês | MEDLINE | ID: mdl-31250849

RESUMO

High-throughput fluorescence polarization immunoassays (FPIAs) for mycotoxin were conducted using a portable FP analyzer with a microdevice. Simultaneous FPIA measurements for 8 different deoxynivalenol (DON) concentrations in 12 chambers (total of 96 samples) and high-throughput FPIA measurements for single DON concentrations in more than 500 chambers were conducted. The results indicated that simultaneous FPIAs for 96 independent samples and for 500 samples were possible by FP imaging. The FP analyzer has a size of 65 cm (W 35 cm × D 15 cm × H 15 cm) and costs less than $5000. The sample volume was 1 nL. Furthermore, it is expected that sample reaction and FP detection can be automatically conducted with the analyzer by changing the microdevice and the software. Its features such as low cost and portability will contribute to on-site measurement and point-of-care testing. Additionally, the high-throughput feature will contribute to the study of molecular interactions based on FP measurements.

11.
Lab Chip ; 19(2): 233-240, 2019 01 15.
Artigo em Inglês | MEDLINE | ID: mdl-30547178

RESUMO

We have developed a microdevice for therapeutic drug monitoring. In this device, dispensing of sample and reagent was accomplished by simple manual operation of a syringe. Moreover, for a simple and rapid measurement, we used cloned enzyme donor immunoassay as a detection principle. These features and the reagent that is enclosed in microdevice beforehand make it possible to complete the facile analysis. In this paper, our model analyte was 1,3-dimethylxanthine (theophylline), a kind of bronchodilator. The fluorescence measurement of theophylline in whole blood was achieved with the limit of detection of 0.73 µg mL-1. This microdevice provides rapid analysis (4 min), requires only a small volume of sample (2 µL) and features simple operation; hence, it is readily applicable to point of care testing.


Assuntos
Análise Química do Sangue/instrumentação , Monitoramento de Medicamentos/instrumentação , Técnicas Imunoenzimáticas/instrumentação , Técnicas Analíticas Microfluídicas/instrumentação , Teofilina/sangue , Adulto , Monitoramento de Medicamentos/métodos , Desenho de Equipamento , Humanos , Limite de Detecção , Modelos Lineares , Masculino , Testes Imediatos , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...