1.
Dent Mater J ; 42(4): 478-484, 2023 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-37121735

RESUMO

This study investigated the effect of 10-methacryloyloxydecyl dihydrogen phosphate (MDP) in methyl methacrylate (MMA) monomer on the adhesion of tri-n-butylborane (TBB)-initiated resins (MDP/MMA-TBB resins) to human enamel. Enamel surface conditions were either polished only or phosphatized surfaces. The 1.0, 1.7, and 2.0 mol% MDP/MMA-TBB resins, 4-methacryloxyethyl trimellitate anhydride (4-META)/MMA-TBB resin and MMA-TBB resin were prepared as luting materials. The shear bond strength was determined before and after thermocycles, and the results were compared using non-parametric statistical analyses (each, n=15). The MDP/MMA-TBB resins showed significantly better bond durability to enamel than other resins with or without etching. The 1.7 and 2.0 mol% MDP/MMA-TBB resins were suggested to be the optimum MDP concentrations from pre- and post-thermocycling results for the non-etched specimens. The TBB initiator resin including MDP was shown to be effective in bonding to human enamel, and this effect was enhanced in combination with phosphate treatment.


Assuntos
Colagem Dentária , Metilmetacrilatos , Humanos , Metilmetacrilatos/química , Metilmetacrilato/química , Compostos de Boro/química , Metacrilatos/química , Esmalte Dentário , Colagem Dentária/métodos , Teste de Materiais , Cimentos de Resina/química
2.
Materials (Basel) ; 13(9)2020 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-32370001

RESUMO

The aim of this study was to clarify the influence of the copper surfaces changed from Cu or Cu2O to CuO on the bonding strength of resin with organic sulfur compounds. The disk-shaped specimens (n = 44) of copper were wet-ground. Half of the specimens were heated at 400 °C for 4 min in an electric furnace (HT: heated). Half of the specimens were not heated (UH: unheated). The specimens were further divided into two groups. Each group was primed by 6-methacryloyloxyhexyl 2-thiouracil-5-carboxylate (MTU-6) or unprimed (n = 11). A statistical analysis of the results of shear bond strength testing was performed, and the failure mode of the bonded areas was classified with an optical microscope. Two types of specimen surface (UH or HT) were analyzed chemically using X-ray photoelectron spectroscopy (XPS). When primed with MTU-6, unheated Cu (28.3 MPa) showed greater bond strength than heated (19.1 MPa). When unprimed, heated Cu (4.1 MPa) showed greater bond strength than unheated (2.3 MPa). The results of the debonded surfaces observation showed that only the UH-MTU-6 group demonstrated a combination of adhesive and cohesive failures in all specimens. The XPS results showed that the surface of copper changed from Cu or Cu2O to CuO when HT. These results confirmed that it is necessary to take care of the copper oxide contained in noble metal alloys when using organic sulfur compounds for adhesion.

3.
J Oral Sci ; 61(2): 358-363, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31217387

RESUMO

The purpose of this study was to evaluate the surface properties and gloss of CAD/CAM composites after toothbrush abrasion testing. Four CAD/CAM composites for molars (Cerasmart 300, Estelite P block, Katana Avencia P block, and KZR-CAD HR3 Gammatheta), one CAD/CAM composite for premolars (Shofu Block HC Hard), and one feldspathic ceramics (Vitablocs Mark II) were assessed. Knoop hardness number, gloss, and surface roughness (Ra, Rz, and Sa) were measured before and after toothbrush abrasion testing. Knoop hardness number values were in the order Vitablocs Mark II > Katana Avencia P block > Estelite P Block > Shofu Block HC Hard > Cerasmart 300 > KZR-CAD HR3 Gammatheta. After testing, the gloss of Estelite P block and KZR-CAD HR3 Gammatheta was greatly decreased and surface roughness was greatly increased. Periodic recall and re-polishing may thus be necessary when these products are used clinically.


Assuntos
Resinas Compostas , Desenho Assistido por Computador , Cerâmica , Teste de Materiais , Propriedades de Superfície
4.
Dent Mater J ; 38(4): 540-546, 2019 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-31068549

RESUMO

The purpose of the current study was to evaluate the effect of etching with potassium hydrogen difluoride (KHF2) and ammonium hydrogen difluoride (NH4HF2) on the bond strength of a self-polymerizing methyl methacrylate resin (MMA-TBB) bonded to zirconia. Zirconia disks were prepared using the following surface treatment: no treatment, alumina blasting, and etching with KHF2 or NH4HF2. The specimens were bonded with the MMA-TBB. The shear bond (Ø=5 mm) strength was measured. The surface free energies of the specimens were determined by measuring contact angles. The KHF2 and NH4HF2 groups exhibited higher shear bond strength and surface free energy than did the alumina blasting and no treatment groups. Compared with alumina blasting, etching with KHF2 and NH4HF2 exhibited superior bonding ability of mechanical retention to zirconia.


Assuntos
Compostos de Amônio , Colagem Dentária , Compostos de Boro , Hidrogênio , Teste de Materiais , Metacrilatos , Potássio , Cimentos de Resina , Resistência ao Cisalhamento , Propriedades de Superfície , Zircônio
5.
J Prosthodont Res ; 63(2): 145-149, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30528398

RESUMO

PURPOSE: The aim of this study was to evaluate the shear bond strength and durability of MMA-TBB resin to human enamel applied a self-etching primer with phosphoric acid etching. METHODS: A self-etching primer (Teeth primer, TP) containing 4-methacryloyloxyethyl trimellitate anhydride (4-META) and sodium sulfite and two etchants having different phosphoric acid concentrations (K-etchant gel, KE, 35-45%: Red gel, RG, 20-25%) were used as treatment agent, and MMA-TBB resin was used as luting agent. Enamel surfaces were treated with six methods which were as follow: KE, RG, TP, KE+TP, and RG+TP. After enamel specimens were bonded with MMA-TBB resin and stored in distilled water for 24h, the shear bond strength test was done at 0 thermocycling or 20,000 thermocycling. These results were statistically verified with Steel-Dwass multiple comparisons and Man-Whitney U test. RESULTS: The shear bond strength of TP group, KE+TP group, and RG+TP group were significantly higher than KE group and RG group in pre-thermocycling. KE+TP group and RG+TP group were significantly higher than other groups in post-thermocycling. CONCLUSIONS: Applying TP with phosphoric acid etching can increased shear bond durability despite difference of phosphoric acid concentrations (35-45% or 20-25%).


Assuntos
Condicionamento Ácido do Dente/métodos , Compostos de Boro , Colagem Dentária , Cimentos Dentários , Esmalte Dentário , Teste de Materiais , Metacrilatos , Metilmetacrilatos , Resinas Sintéticas , Resistência ao Cisalhamento , Sulfitos , Relação Dose-Resposta a Droga , Humanos , Ácidos Fosfóricos
6.
J Prosthodont Res ; 63(1): 95-99, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30385330

RESUMO

PURPOSE: This study investigated the influence of an interaction between sulfur-containing monomers and other monomers in multipurpose primers on the bond durability of a tri-n-butylborane (TBB)-initiated acrylic resin to a gold alloy. METHODS: The disk-shaped adherend materials were prepared from a gold alloy (Casting Gold M.C. Type IV). Two multipurpose-primers (Universal Primer, Monobond Plus), four metal primers containing an organic sulfur compound (M.L. Primer, Alloy Primer, Metaltite, and V-Primer), and three acidic primers (Estenia Opaque Primer, Acryl Bond, and Super-Bond Liquid) were used. The shear bond strengths were determined pre- and post-thermocycling to evaluate the bond durability. A statistical analysis of the results was performed using a non-parametric procedure, and the cohesive failure ratios of the debonded surfaces were compared. RESULTS: Among the pre-thermocycling groups, M.L. Primer, Metaltite, Monobond Plus, Universal Primer, and Alloy Primer showed the greatest bond strengths. Among the post-thermocycling groups, M.L. Primer, Metaltite, Monobond Plus, and Universal Primer showed the greatest bond strengths, whereas Acryl Bond, Super-Bond Liquid, Estenia Opaque Primer, and the unprimed control showed the lowest. Similarly, the primers that did not contain either a sulfur compound showed an obvious reduction in the cohesive failure ratio. CONCLUSIONS: Multi-purpose primers containing a sulfur-containing monomer increased the bond strength of a TBB-initiated acrylic resin to a gold alloy. The proportion of the area of cohesive failure to the bonded area showed an interrelationship with the shear bond strength testing results.


Assuntos
Resinas Acrílicas , Compostos de Boro , Colagem Dentária , Ligas de Ouro , Metacrilatos , Resinas Sintéticas , Tionas , Tiouracila/análogos & derivados , Análise do Estresse Dentário , Teste de Materiais , Resistência ao Cisalhamento
7.
Dent Mater J ; 37(3): 429-436, 2018 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-29375093

RESUMO

This study aimed to investigate how different compositions of experimental silane-based primers in a methyl methacrylate solution containing 3-(trimethoxysilyl)propyl methacrylate (3-TMSPMA) or 3-(4-methacryloyloxyphenyl)propyl trimethoxysilane (3-MPPTS) might act as silicon dioxide bonding agents. With or without post-silanization heat treatment, primer-treated quartz discs were bonded using the MMA-TBB resin and their bond strengths were evaluated. The disks were primed with one of the following materials: 1 mol% 3-TMSPMA, 2 mol% 3-TMSPMA, 1 mol% 3-MPPTS, and 2 mol% 3-MPPTS. Shear bond strength was determined both before and after thermocycling. Statistical analyses were performed with non-parametric procedure (Kruskal-Wallis, Mann-Whitney U, and Steel-Dwass tests). Both primers were effective with heat treatment to enhance bonding between quartz and the MMA-TBB, and the bonding durability of the 1 and 2 mol% 3-MPPTS (16.8 and 24.9 MPa) with heat groups was significantly higher than in the 1 and 2 mol% 3-TMSPMA (5.4 and 9.8 MPa) with heat groups.


Assuntos
Compostos de Boro/química , Materiais Dentários/química , Adesivos Dentinários/química , Metilmetacrilatos/química , Quartzo/química , Cimentos de Resina/química , Silanos/química , Teste de Materiais , Resistência ao Cisalhamento , Estresse Mecânico , Propriedades de Superfície , Temperatura
8.
J Oral Sci ; 59(4): 511-517, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29279566

RESUMO

The purpose of the current study was to evaluate the bonding performance of two single-liquid primers, which contained 6-(4-vinylbenzyl-n-propyl) amino-1,3,5-triazine-2,4-dithione (VTD) or 6-methacryloyloxyhexyl 2-thiouracil 5-carboxylate (MTU-6), used for bonding between metals and an acrylic resin. A gold alloy and high-purity titanium were used as adherend materials, and a transparent acrylic resin initiated with tri-n-butylborane derivative was selected as the luting material. Both adherends were treated with one of the primers and bonded with the luting material, after which shear bond strength was determined. Fourier transform infrared spectroscopy was used to analyze debonded resin specimens. Shear bond strength to gold alloy was significantly greater than that to titanium for both the VTD and MTU-6 primers. A trace of thiol structure, probably derived from VTD and MTU-6, was detected on resin surfaces debonded from gold alloy. These results indicate that the two organic sulfur compounds, which are stable in an atmospheric environment, are tautomerized into a thiol structure, thus allowing adsorption onto noble metals. In addition, the adsorbed thiol compounds contribute to chemical bonding between the acrylic resin and noble metal alloy, as polymerizable adhesive functional monomers.


Assuntos
Resinas Acrílicas/química , Ligas de Ouro/química , Compostos Orgânicos/análise , Enxofre/análise , Teste de Materiais , Espectrofotometria Infravermelho
9.
Dent Mater J ; 36(1): 19-26, 2017 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-27928101

RESUMO

This study aimed to evaluate the effect of surface preparation on bond strength of a tri-n-butylborane initiated resin (MMA-TBB) bonded to zirconia. Zirconia disks were either airborne-particle abraded with alumina or silica-coated. The disks were thereafter primed with one of the following materials: phosphate-silane (Clearfil Ceramic Primer), phosphate (Alloy Primer), or silane (ESPE Sil). The specimens were bonded with the MMA-TBB. Shear bond strength was determined both before and after thermocycling. Bond strength of unprimed zirconia (control) was not affected by the surface roughness of each adherend. Priming with phosphate was effective for bonding alumina-blasted zirconia. Priming with silane was effective for bonding silica-coated zirconia. Priming effect of the phosphate-silane was superior to that of silane alone for bonding silica-coated zirconia. Bond strength to zirconia of the MMATBB is significantly influenced by a combination of the specific functional monomer and the surface modification performed rather than the material surface roughness.


Assuntos
Colagem Dentária , Zircônio , Óxido de Alumínio , Cerâmica , Teste de Materiais , Cimentos de Resina , Resistência ao Cisalhamento , Silanos , Propriedades de Superfície
10.
J Oral Sci ; 57(4): 385-8, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26666864

RESUMO

This clinical report describes the bonding procedure and clinical course of a natural tooth pontic in a 65-year-old male patient. A mandibular lateral incisor was extracted due to severe marginal periodontitis. The root of the tooth was amputated and a pontic structure was formed by filling acrylic resin into the coronal pulp chamber space. The enamel surface of the pontic and the adjacent abutment teeth were etched with phosphoric acid gel. The pontic was bonded with a modified tri-n-butylborane initiated adhesive resin (Super-Bond Quick). The connecters fractured 11 years after bonding when the patient accidentally bit a metallic chopstick. Recurrence of the fracture, however, did not occur, and the re-seated pontic has been functioning for more than 1 year. Although proper maintenance of both the periodontal tissue and splinted dentition is required, this minimally invasive technique can be applied in selected patients suffering from periodontal diseases.


Assuntos
Compostos de Boro/química , Resinas Compostas , Colagem Dentária , Implantes Dentários para Um Único Dente , Mandíbula , Idoso , Humanos , Masculino
11.
Dent Mater J ; 34(6): 881-7, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26632238

RESUMO

The purpose of this study was to evaluate the gloss and surface roughness behaviors of newly developed CAD/CAM composite blocks with different filler contents and characteristics. The gloss and surface roughness were quantified before and after a toothbrush dentifrice abrasion test; the results were compared to the gloss and surface roughness of a ceramic CAD/CAM block. Knoop hardness was determined before abrasion test. The results were analyzed by ANOVA, Tukey HSD, and Dunnett t test (p<0.05). The rank order of Knoop hardness was as follows: Vita Mark II>Vita Enamic>Gradia block>Shofu Block HC, Lava Ultimate≥Katana Avencia block≥Cerasmart. After toothbrush abrasion, a significant difference in the gloss unit was detected between the Shofu Block HC material and the ceramic block. The Ra and Rz of the Cerasmart and Shofu Block HC materials were significantly larger than those of the ceramic block after toothbrush abrasion.


Assuntos
Cerâmica/química , Resinas Compostas/química , Desenho Assistido por Computador , Desgaste de Restauração Dentária , Escovação Dentária , Coroas , Materiais Dentários/química , Dentifrícios , Dureza , Teste de Materiais , Microscopia Eletrônica de Varredura , Propriedades de Superfície
12.
Dent Mater J ; 34(2): 219-26, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25740168

RESUMO

The purpose of this study was to evaluate the shear bond strength and durability of 4-META/MMA-TBB resin to human enamel. A self-etching primer that contained 4-META (Teeth Primer, TP) and 35-45% or 60-65% concentrations of phosphoric acid (K-Etchant Gel, KE, and Super Bond C&B Red Activator, RA) were used as the surface treatment agents. A methyl methacrylate (MMA)-based self-polymerizing resin (Super-Bond C&B) was used as a luting agent. The shear bond strength was determined both pre and post thermocycling. The results were statistically analyzed with a non-parametric procedure. The post-thermocycling shear bond strength of the TP group was significantly higher than that of other groups, and that of the KE group was significantly higher compared with the RA group. These results demonstrated that 4-META was effective. Furthermore, when the degree of tooth demineralization was compared, surface treatment with less demineralization using TP was the most effective treatment.


Assuntos
Compostos de Boro/farmacologia , Esmalte Dentário/efeitos dos fármacos , Metilmetacrilatos/farmacologia , Ácidos Fosfóricos/farmacologia , Condicionamento Ácido do Dente/métodos , Cimentos Dentários , Análise do Estresse Dentário , Humanos , Teste de Materiais , Cimentos de Resina , Resistência ao Cisalhamento/efeitos dos fármacos , Resistência à Tração
13.
J Oral Sci ; 57(1): 17-24, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25807904

RESUMO

The purpose of the present study is evaluation of bonding durability of tri-n-butylborane (TBB) initiated resin without 4-methacryloyloxyethyl trimellitate anhydride (4-META) joined to human enamel. Ground human enamel was bonded with TBB resin under six surface conditions: 1) as ground, 2) primed with Teeth Primer, 3) sodium sulfite solution, 4) 4-META solution, 5) acetone-water, and 6) phosphoric acid etching. Pre- and post-thermocycling bond strengths and change in strength after thermocycling were compared. Etching enamel with 35-45% phosphoric acid enhanced bonding durability between enamel and TBB-initiated resin. Priming with Teeth Primer or 4-META solution improved bond strength between enamel and TBB-initiated resin. Sodium sulfite had little effect on enamel bonding in the present bonding systems.


Assuntos
Compostos de Boro/química , Colagem Dentária/métodos , Esmalte Dentário/química , Cimentos de Resina/química , Sulfitos/química , Acetona/química , Condicionamento Ácido do Dente , Análise do Estresse Dentário , Humanos , Técnicas In Vitro , Metacrilatos/química , Microscopia Eletrônica de Varredura , Dente Molar , Ácidos Fosfóricos , Propriedades de Superfície
14.
Dent Mater J ; 33(6): 865-73, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25483387

RESUMO

The purpose of this study was to evaluate the influence of ceramic surface texture on the wear of rounded rod specimens. Plate specimens were fabricated from zirconia (ZrO2), feldspathic porcelain, and lithium disilicate glass ceramics (LDG ceramics). Plate surfaces were either ground or polished. Rounded rod specimens with a 2.0-mm-diameter were fabricated from type 4 gold alloy and heat-pressed ceramics (HP ceramics). Wear testing was performed by means of a wear testing apparatus under 5,000 reciprocal strokes of the rod specimen with 5.9 N vertical loading. The results were statistically analyzed with a non-parametric procedure. The gold alloy showed the maximal height loss (90.0 µm) when the rod specimen was abraded with ground porcelain, whereas the HP ceramics exhibited maximal height loss (49.8 µm) when the rod specimen was abraded with ground zirconia. There was a strong correlation between height loss of the rod and surface roughness of the underlying plates, for both the gold alloy and HP ceramics.


Assuntos
Cerâmica/química , Desgaste de Restauração Dentária , Ligas de Ouro/química , Silicatos de Alumínio/química , Polimento Dentário , Porcelana Dentária/química , Análise do Estresse Dentário , Temperatura Alta , Teste de Materiais , Compostos de Potássio/química , Propriedades de Superfície , Zircônio/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA